Search Submissions 🔎

Results for "effective doses": 120 found

A 3D Printed Ion Chamber Insert Solution for Absolute Dosimetry with Varying Ionisation Chambers in Radiosurgery.

Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma

Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...

A Hybrid 4π-Proton Arc Robust Optimization

Authors: Wenhua Cao, Xianjin Dai, PhD, Hadis Moazami Goudarzi, Gino Lim, Miaolan Xie, Lei Xing, Lewei Zhao

Affiliation: University of Chicago Booth School of Business, Department of Radiation Oncology, Stanford University, Department of Industrial Engineering, University of Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) delivers a continuous dose of radiation during gantry rotation. 4π is a non-coplanar technique used for advanced proton therapy delivery. This work proposes a hybrid ...

A Multi-Criteria Optimization Method Based on Reinforcement Learning and Adaptive Boosting in Radiation Therapy

Authors: Liqin HU, Tao He, Jing JIA, Pengcheng LONG, Wei Meng, Yang Yuan

Affiliation: SuperAccuracy Science & Technology Co. Ltd.

Abstract Preview: Purpose: A multi-criteria optimization method based on reinforcement learning and adaptive boosting(RLAB MCO) has been developed to enhance radiotherapy plan quality by offering reasonable and effecti...

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

A Novel Design of Photon-Counting Static Cone-Beam CT System for Dedicated Breast Imaging

Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...

A Novel Metric for Predicting Heart Dose Assessment in Left-Sided Breast Cancer Radiotherapy

Authors: Yufeng Cao, Arun Gopal, Kai Huang, Kai Wang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland Medical Center, University of Maryland, Baltimore

Abstract Preview: Purpose: The treatment of left-sided breast tumors poses significant concerns regarding the risk of radiation-induced damage to nearby organs, particularly the heart. In clinical practice, breath-hold...

A Quantitative Analysis of Interplay Effects in IMPT for Lung Cancer SBRT: Comparing Two Machine Delivery Sequence Models

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...

A Quantitative, Predictable Guided Optimization Approach for Eclipse to Mitigate the SRS “Ring of Fire”

Authors: Ivan L. Cordrey, Dharmin D. Desai

Affiliation: Cumberland Medical Center - Cancer Center, Varian Advanced Oncology Solutions

Abstract Preview: Purpose: For larger PTVs, VMAT optimizations performed within Eclipse often generate SRS plans with widely scattered hotspots distributed around the inner edge of the PTV – the “ring of fire.” This pr...

Absolute Measurement of HDR Ir-192 Air-Kerma Strength Using an Exradin A3 Known-Volume Ionization Chamber

Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

An Agglomerative Clustering-Based Program for Optimizing Multiple-Target SRS Treatment Planning

Authors: Josephine Chen, CheukKai Becket Hui, Yildirim D. Mutaf

Affiliation: Kaiser Permanente

Abstract Preview: Purpose:
To demonstrate the effectiveness of a target clustering program in generating cluster configurations and isocenter placements for multiple brain lesions in SRS treatment planning, with the...

An Efficient Workflow for X-Ray Imaging-Based IGRT/ART

Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...

Assessing Long-Term Stability of Parylene-Coated, 3D-Printed Plastic Vessels for Water Calorimetry-Based Radiation Dosimetry

Authors: Philip Cutter, Mark D'Souza, Arman Sarfehnia

Affiliation: Toronto Metropolitan University, Sunnybrook Health Sciences Centre, Sunnybrook Health Science Center

Abstract Preview: Purpose: Water calorimetry (WC) serves as an important standard for measuring absorbed dose to water, an essential metric in radiation therapy. WC directly and absolutely quantifies energy deposition ...

Assessment of Viscoelastic Changes in Ex Vivo Liver Tissue Using Pulsed Magnetomotive Ultrasound during Magnetic Hyperthermia

Authors: David Alejandro Collazos Burbano, Antonio Adilton Oliveira Carneiro, Paul L. Carson, Jose Eduardo Freire, Theo Zeferino Pavan, Joao Henrique Uliana, Nicholas Zufelato

Affiliation: University of SĂŁo Paulo, University of Michigan, University of Sao Paulo

Abstract Preview: Purpose: Develop a theranostic platform that integrates magnetic hyperthermia (MH), ultrasound, and magnetic nanoparticles (MNPs) to improve diagnosis, treatment, and monitoring of hyperthermia proced...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

Auto-Beam Hold Validation for Varian Sgrt Identify 3.0 on Truebeam Linear Accelerators

Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...

Automated Treatment Planning for Stereotactic Recurrent Head and Neck Cancers Using Knowledge-Based Planning, Multicriteria Optimization, and Dosimetric Scorecards

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstration of automated stereotactic treatment planning for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecard...

Automatic Contour Quality Assurance Using Deep-Learning Based Contours

Authors: Laurence Edward Court, Raphael Douglas, David Fuentes, Anuja Jhingran, Barbara Marquez, Raymond Mumme, Christine Peterson, Julianne M. Pollard-Larkin, Surendra Prajapati, Dong Joo Rhee, Thomas J. Whitaker

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Safe deployment of auto-contouring models requires the inclusion of automated quality assurance (QA). One approach is to use an independent auto-contouring model and compare the contours geom...

Biologically Guided Deep Learning for MRI-Based Brain Metastasis Outcome Prediction after Stereotactic Radiosurgery

Authors: Evan Calabrese, Hangjie Ji, Kyle J. Lafata, Casey Y. Lee, Eugene Vaios, Chunhao Wang, Lana Wang, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke Kunshan University, North Carolina State University

Abstract Preview: Purpose: To develop a biologically guided deep learning (DL) model for predicting brain metastasis(BM) local control outcomes following stereotactic radiosurgery (SRS). By integrating pre-SRS MR image...

Brachify: An Open-Source 3D Modeling Solution for 3D Printable Cervical and Vaginal Cylindrical Templates

Authors: Michael Kudla, Stephanie Merkl

Affiliation: BC Cancer - Kelowna

Abstract Preview: Purpose: 3D modeling for 3D printed GYN high dose rate (HDR) brachytherapy templates can be a time-consuming, error-prone process. To simplify the creation these templates, a software application has ...

CBCT-Based Synthetic CT Imaging for Proton and Photon Dose Monitoring and Adaption in Supine Breast Radiotherapy

Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang

Affiliation: UF Health Proton Therapy Institute, University of Florida

Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...

CNN-Based Visualization for Detecting Failure Patterns of Lung SBRT through CT-Biological Effective Dose Interaction

Authors: Ashok Bhandari, Kurtis Johnson, Yu Lei, Tianzhe Li, Kyuhak Oh, Shuo Wang, Chi Zhang, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: The purpose of this study was to leverage neural network visualization tools to detect high-attention areas indicative of treatment failure in lung SBRT by examining correlation matrices betw...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Characterization of a Novel Large-Sized Epid System from the Newly Released Ring Shape Radiation Therapy Halos Tx

Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang

Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment

Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...

Clinical Feasibility of a Deep-Learning-Based Auto Contouring through Qualitative and Dosimetric Assessments

Authors: Sara Endo, Takeshi Fujisawa, Hidehiro Hojo, Masaki Nakamura, Hidenobu Tachibana

Affiliation: Department of Radiation Oncology, National Cancer Center Hospital East, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: To assess the clinical feasibility of deep learning (DL)-based automated contouring through qualitative and quantitative assessments.

Methods: Sixty cases were chosen, including 3 OARs...

Clinical Outcomes of Gamma Knife Stereotactic Radiosurgery Treatments for Intracranial Arteriovenous Malformations & Fistulas: A Single Institutional Retrospective Study

Authors: Madeleine Arbogast, David Dorndos, Denise E Foltz, Justin Fraser, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Neurosurgery, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: For stereotactic radiosurgery (SRS) treatments of intracranial arteriovenous malformations (AVM) and fistulas (AVF), same-day Leksell Gamma Knife (GK) is the preferred modality. Long-term cli...

Clinically Ready Simulation Package for Monitoring Gamma Hotspot Emission, and Detection in Patient Anatomy

Authors: Ananta Raj Chalise, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: Prompt gamma (PG) imaging is a promising modality for proton dose verification. Currently, there is a lack of effective tool to investigate the PG emission during proton therapy and optimize ...

Commissioning of Elekta Leipzig and Valencia Skin Applicators

Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao

Affiliation: The George Washington University, The George Washington University Cancer Center

Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Conversion Coefficients from Hp(10) to Organ and Effective Doses for Medical Staff Involved in Fluoroscopically Guided Interventional Procedures

Authors: Stephen Balter, Haegin Han, Cari M Kitahara, Taeeun Kwon, Choonsik Lee, Martha S Linet, Donald L. Miller

Affiliation: Columbia University Medical Center, National Cancer Institute, Food and Drug Administration

Abstract Preview: Purpose: Staff in fluoroscopically guided interventional (FGI) procedures are exposed to radiation. Inhomogeneous radiation fields and variability in procedural conditions make it challenging to deriv...

Deep Learning-Based Eye Monitoring and Tracking System for Ocular Proton Therapy in a Regular Gantry Room

Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai

Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...

Design, Optimization, and Preclinical Validation of a Novel Applicator Integrating Real-Time Dose Monitoring for Ultra-High Dose Rate (FLASH) Electron Radiotherapy

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose: To develop, optimize and validate a novel applicator for ultra-high dose rate (UHDR) electron radiotherapy incorporating an electrostatically shielded beam current transformer (BCT) for real-...

Detector Physics-Incorporated Diffusion Denoising Models for Digital Breast Tomosynthesis with Dual-Layer Flat Panel Detectors

Authors: Alexander Bookbinder, Matthew Tivnan, Xiangyi Wu, Wei Zhao

Affiliation: Stony Brook Medicine, Massachusetts General Hospital

Abstract Preview: Purpose: To investigate and benchmark a system-adaptive diffusion-based digital breast tomosynthesis (DBT) denoising model for a direct-indirect dual-layer flat panel detector (DI-DLFPD) with a k-edge...

Development and Validation of Patient-Specific 3D-Printed Electron Applicators for Precision Radiotherapy

Authors: Md. Jobairul Islam

Affiliation: Department of Radiation Oncology, Labaid Cancer Hospital and Super Speciality Centre

Abstract Preview: Purpose: Electron radiotherapy is an effective treatment for superficial tumors but requires field-shaping devices like electron applicators, which are labor-intensive to produce. This study aimed to ...

Development of Cross-Platform Application for Radiation Contamination Assessment

Authors: Wesley E. Bolch, Lotem Buchbinder Shadur, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Shaheen Dewji, John Francis, Emmanual Mate-Kole, Wyatt Smither, Yitian Wang

Affiliation: Georgia Tech, University of Florida, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology

Abstract Preview: Purpose: Develop a software application capable of assessing the radiation contamination of military service members and members of the general public for fast, on-site radiological triage. The softwa...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Development of an Eclipse Scripting API-Based Toolbox for Automated Planning in Non-Small Cell Lung Cancer: Feasibility and Validation Study

Authors: Ming Chao, Hao Guo, Tenzin Kunkyab, Yang Lei, Tian Liu, Kenneth Rosenzweig, Robert Samstein, Junyi Xia, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose:
This study aims to develop and validate an Eclipse Scripting Application Programming Interface (ESAPI)-based planning toolbox that incorporates preset human expertise to improve planning e...

Dosimetric Assessment of Spatially Fractionated Radiation Therapy on Prostate Cancer Cases: Our Experience in Nsia-Luth Cancer Center, Lagos

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Sylvester Entonu, Muhammad Habeebu, Adedayo O. Joseph, Oluwaseyi Oderinde, Oluwadara Ojediran, Margaret Dideolu Taiwo

Affiliation: University of Ibadan, University of Lagos, Missouri University of Science and Technology, Purdue University, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre

Abstract Preview: Purpose:
Spatially Fractionated Radiation Therapy (SFRT) is an advanced radiotherapy technique designed to deliver highly heterogeneous radiation doses, aiming to optimize tumor control while minim...

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...

Dosimetric Comparison & Error Analysis of Aapm TG51 & WGTG51-e Protocol with Icru-90 Key-Data for High-Energy Clinical Electron Beam

Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...

Dosimetric Validation and Algorithmic Limitations of Pencil Beam Scanning Proton Therapy for Thin Chest-Wall Treatments

Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng

Affiliation: New York Proton Center, Scarsdale High School

Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...

Early GU Toxicity Prediction in Prostate SBRT Using Delivered Dosimetry Via Long Short-Term Memory Model

Authors: Amar Kishan, Jun Lian, Yunkui Pang, Jonathan Pham, X. Sharon Qi, Michael Steinberg, Luca F Valle, Pew-Thian Yap

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of North Carolina at Chapel Hill

Abstract Preview: Purpose: Stereotactic body radiotherapy (SBRT) is a highly effective treatment for prostate cancer, yet predicting genitourinary (GU) toxicity has primarily relied on planned dosimetry. This study inv...

Effects of Plan Optimization Techniques on Relative Biological Effective Dose in a Thin Intracranial Target Volume

Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center

Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...

Emulating Human Perception of Low-Dose CT Image Quality Via Deep Generative Models

Authors: Jongduk Baek, Jooho Lee, Adam S. Wang

Affiliation: Stanford University, Yonsei University

Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...

Enhancement of Adaptive Collimation Precision on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate aperture collimation on a C-shape gantry-mounted proton accelerator. Mevion S250i Hyper scanning machine implemented aperture collimation utilizing adaptive aperture (AA). The AA ...

Evaluating Three Practical Approaches to Managing Dose Accumulation in Normal Tissues during Radiation Re-Treatments

Authors: Derek A. Fiedler, Nixon Gutierrez, Quyen L. Jones, Zejian Liu, Tatsiana Reynolds

Affiliation: Texas Oncology, Minnesota Oncology, US Oncology

Abstract Preview: Purpose: Optimize patient safety and treatment efficacy during radiation re-treatment planning. Provide a comprehensive comparison of the methods by focusing on their applicability, accuracy, and limi...

Evaluating the Readiness for Ultra-Hypofractionated Prostate and Breast Radiotherapy in Sub-Saharan Africa: A Strategic Needs-Assessment of Six Leading African Institutions

Authors: Samuel O. Adeneye, Victoria Susan Ainsworth, Azeezat Ajose, Stephen M. Avery, Munir Awol, Kavuma Awusi, Onyinye Balogun, Rohini Bhatia, Frank Chinegwundoh, Jumaa Dachi Kisukari, Curtiland Deville, Katy Graef, Yao Hao, M. Saiful Huq, Luca Incrocci, Adedayo O. Joseph, Solomon Kibudde, Joerg Lehmann, Heng Li, Abba Mallum, Thokozani Mkhize, Twalib Ngoma, Wilfred Ngwa, Christopher F. Njeh, Janine Simons, William Swanson, Maureen Bilinga Tendwa, Joseph Weygand, Krishni Wijesooriya

Affiliation: Uganda Cancer Institute, Johns Hopkins University, BIO Ventures for Global Health, Weill Cornell Medicine, Washington University School of Medicine, South Africa Health Product Regulatory Authority, University of Pennsylvania, University of Massachusetts Lowell, NSIA-LUTH Cancer Center, University of Lagos, Indiana University School of Medicine, Department of Radiation Oncology, Erasmus Medical Center, Department of Radiation Oncology and Applied Science, Dartmouth Health, Addis Ababa University, Ocean Road Cancer Institute, Emory University, Barts Health NHS Trust, Inkosi Albert Luthuli Central Hospital, Lagos University Teaching Hospital, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, University of Virginia School of Medicine, University of Newcastle

Abstract Preview: Purpose: Sub-Saharan Africa continues to face a critical shortage in radiotherapy resources, exacerbating the region’s growing cancer burden. One potential strategy that can partially offset this prob...

Evaluating the Theranostic Potential of a Novel Shark Derived Anti-MET Vnar Antibody in NSCLC

Authors: Andrew M Baschnagel, Jonathan W. Engle, Jessica E. Griffin, Gihan Gunaratne, Reinier Hernandez, Randall J Kimple, Aaron M. LeBeau, Natalie Y. Luo, Rachel Minne, Caroline M. Mork, Kwangok P Nickel, Jayden West, Madalynn R. Wopat

Affiliation: University of Wisconsin, University of Wisconsin, Department of Pathology and Laboratory Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin–Madison, University of Wisconsin - Department of Human Oncology, UW Madison, University of Wisconsin, Department of Medical Physics

Abstract Preview: Purpose: The Mesenchymal-Epithelial Transition gene (MET), a targetable cell surface receptor responsible for stimulating cell growth and proliferation, is altered in approximately 10% of non-small ce...

Evaluation of Hypersight CBCT Scanning Techniques for Motion Management in Online Adaptive Radiotherapy: A Comparative Study of Slow, Fast, and Averaged Scans

Authors: Fan Liu, Adam C. Riegel, Yi-Fang Wang

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: HyperSight, Varian Medical Systems' latest CBCT technology, integrates rapid 6-second data acquisition with advanced iterative reconstruction, enabling precise real-time contouring and dose c...

Evaluation of Noise and Dose Efficiency in Clinical Photon-Counting CT Colonography with Tin Prefiltration

Authors: Xinhui Duan, Vivek Nair, Liqiang Ren, KyuHo Song, Vasantha Vasan, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center

Abstract Preview: Purpose: Minimizing radiation dose is crucial in CT colonography (CTC) screening and diagnosis. Tin (Sn) prefiltration is readily incorporated into clinical photon-counting CT (PCCT) scanners, yet its...

Evaluation of Phosphorus-32 Source Uniformity Using Python Algorithm and Monte Carlo Simulation

Authors: Ana Laura Burin, Ilca Marli Moitinho Amaral Medeiros, Priscila Santos Rodrigues, Maria Elisa Chuery Martins Rostelato, Sabrina Spigaroli Sgrignoli, Ana Catarina Koka de Souza Silva, Carla Daruich Souza, Cristhian Ferreira Talacimon, Lara El Hajj Teodoro, Carlos Alberto Zeituni

Affiliation: IPEN - USP, IPEN - Instituto de Pesquisas Energéticas e Nucleares

Abstract Preview: Purpose: The uniform distribution of phosphorus-32 (32P) in beta sources is essential to ensure the accuracy of radiotherapy treatments, such as those for paravertebral cancer. This study evaluated th...

Experience in Commissioning and Quality Assurance of Halcyon Linear Accelerator Ver3.0 at a Community Hospital and an Academic Institution

Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma

Affiliation: University of California San Francisco, University of California, San Francisco, University of California

Abstract Preview: Purpose:
The Varian Halcyon Linear Accelerator has become increasingly popular in both community hospitals and academic institutions due to its user-friendly design and operational efficiency. This...

Extremity Imaging with Cone-Beam CT (CBCT) Scanner Dedicated for Hip Imaging – What Are the Effective Doses?

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

Feasibility Study of Group Sparse-Based Beam Angle Optimization for Multi-Field Carbon Ion Radiotherapy

Authors: Min Cheol Han, Hojin Kim, Jin Sung Kim, Hyejin Lee, Sac Lee, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) is characterized by high relative biological effectiveness (RBE), which must be integrated into the treatment planning process. This study aims to develop a nov...

Feasibility of Commercial Independent-Dose-Calculation for Pencil-Beam-Scanning Proton Therapy

Authors: Wen C. Hsi, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...

Feasibility of Using a Dynamic-Platform with High-Resolution Patient-Specific QA Device for Periodic and Patient-Specific-QA in Respiratory-Gated Radiotherapy Lung SBRT Treatment

Authors: Tae Kyu Lee

Affiliation: Allina Health

Abstract Preview: Purpose: To assess the feasibility of a dynamic-platform integrated with high-resolution patient-specific-quality-assurance (PSQ device for periodic quality assurance (PQA) and PSQA in respiratory-gat...

Finding the Best Match of 4D-CT Phases to Delineate Volumes for Bgrt

Authors: Resat Aydin, Joseph Barbiere, Brett Lewis, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose:
Accurately compensating for respiratory-induced tumor motion is critical in BgRT, where precise delineation of volumes ensures effective dose delivery. We propose an integrated approach th...

Foresight Planning: Radiotherapy Plan Optimization Via Self-Supervised Model Predictive Control

Authors: Yang Sheng, Qingrong Jackie Wu, Qiuwen Wu, Xin Wu, Dongrong Yang

Affiliation: Duke University Medical Center

Abstract Preview: Purpose:
Treatment planning for intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) relies on inverse planning, an iterative and non-intuitive process of adjust...

Formulation of Equivalent Dose in 2-Gy Fractions (EQD2) Based on the Linear-Quadratic-Linear (LQL) Model from First Principles

Authors: Makunda Aryal, Qiongge Li, Sook Kien Ng, Christopher F. Njeh, Edwin Quashie, Senthamizhchelvan Srinivasan, Yun Wang

Affiliation: Indiana University Medical School, Memorial Health Care System, Indiana University, Inova Hospital, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Linear-Quadratic-Linear (LQL) model is a modification of the traditional Linear-Quadratic model used in radiobiology to describe cell survival in response to radiation. The LQL model extends ...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

Functional Liver Image Guided Radiation Planning Using MRI with a Contrast Agent

Authors: Kenneth L. Homann, Natalie A Lockney, Hong Zhang

Affiliation: Department of Radiation Oncology, Vanderbilt University Medical Center, Vanderbilt University Medical Center

Abstract Preview: Purpose: The aim of this study is to develop a treatment planning methodology utilizing liver functional imaging via contrast-enhanced Magnetic Resonance Imaging (MRI) in patients undergoing stereotac...

Functional MRI Guided Partial Tumor Irradiation to Improve Tumor Control and Spare Tumor Microenvironment

Authors: Bingqi Guo, Ping Xia

Affiliation: Cleveland Clinic

Abstract Preview: Purpose:
Spatially fractionated radiation therapy (SFRT) delivers a “GRID” or “lattice” of high and low doses to tumors to increase tumor control, minimize normal tissue damage, and preserve the im...

Glandular Dose Map in Voxelized Phantoms across Advanced Breast Imaging Modalities Obtained from Monte Carlo Simulations

Authors: Rodrigo T Massera, Sofia Giaccone Thomaz, Alessandra Tomal, Giovanna Tramontin

Affiliation: Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin, Department of Imaging & Pathology, unit of Medical Physics & Quality Assessment, KU Leuven

Abstract Preview: Purpose: Monte Carlo simulations are increasingly used in breast dosimetry for their precision in estimating difficult-to-measure quantities, such as glandular dose. With ionizing radiation in breast ...

HypersightÂź Offline Adaptive Workflow

Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC

Abstract Preview: Purpose: The goal of the HyperSightÂź offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...

Image-Guided Adaptive Proton Therapy for Head and Neck Cancer Using a Novel Gantry-Less System

Authors: Philip Blumenfeld, Jon Feldman, Yair Hillman, Michael Marash, Aron Popovtzer, Alexander Pryanichnikov, Shimshon Winograd, Marc Wygoda, Vered Zivan

Affiliation: Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), P-Cure Ltd./Inc., Sharett Institute of Oncology, Hadassah Medical Center, Hebrew University of Jerusalem

Abstract Preview: Purpose:
Image-guided adaptive proton therapy (IGAPT) allows tailored dose adjustments to account for anatomical and physiological changes during treatment. Recent efforts have developed a cost-eff...

Impact analysis of effective dose conversion factors from CT scanner models

Authors: Max Chen, Sean Marquardt, Ben Yang, Kai Yang

Affiliation: Cary Academy, Massachusetts General Hospital, Winchester High School

Abstract Preview: Purpose: To analyze the impact of scanner model variation on the effective dose conversion factor (“k-factor”), which is most commonly used for CT effective dose calculation.

Methods: The stand...

Impact of Positron Emission Tomography (PET) Image Characteristics on Biology-Guided Radiotherapy (BgRT) Treatment Accuracy

Authors: Angela J Da Silva, Andrew Groll, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: PET-based biology-guided radiotherapy (BgRT) is a radiation therapy technique that uses PET imaging to deliver tracked dose to the tumor in real-time. We characterized the delivery accuracy o...

Impact on image quality from reduced dose conebeam CT for pediatric fluoroscopy-guided interventional (FGI) imaging

Authors: Samuel L. Brady, Kevin Chen, Joseph G. Meier

Affiliation: University of Cincinnati, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose: Conebeam-CT (CBCT) acquisition protocols typically do not distinguish between adults and pediatrics. In collaboration with a fluoroscopically-guided interventional (FGI) manufacturer, new, do...

Influence of the α/ß Ratio on Dose Constraints in Radiotherapy of Prostate Cancer

Authors: Marwa Y. Abdel Tawwab, Amin E Amin, Abdullah M. ElSharif, Somaia Metwally Elsayed, Magdy M. Khalil

Affiliation: School of Applied Health Science, Badr University in Cairo (BUC), Cairo, Egypt, Medical Physics, Radiation Oncology Department, Faculty of Medicine, Ain Shams University, Medical Biophysics, Department of Physics, Faculty of Science, Helwan University

Abstract Preview: Purpose: Prostate cancer radiotherapy typically employs conventional fractionation schedules over approximately eight weeks. This study investigates the effect of variations in the α/ÎČ ratio on dose c...

Innovative Biological Adaptive Radiotherapy (BART) Approach for Head-and-Neck Cancer Treatment Interruptions

Authors: Nobuki Imano, Daisuke Kawahara, Akito S Koganezawa, Yuji Murakami, Ikuno Nishibuchi, Takuya Wada

Affiliation: Department of Information and Electronic Engineering, Faculty of Science and Engineering, Teikyo University, Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University

Abstract Preview: Purpose: Adaptive radiotherapy (ART) compensates for treatment plans based on anatomical changes while not considering biological effects such as interruptions during treatment. This study aims to dev...

Investigating in-Vivo Megavoltage Radiodynamic Therapy from 6 to 45MV Photon Beam Radiation Therapy with 5-Aminolevulinic Acid

Authors: Lili Chen, Dusica Cvetkovic, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: 5-aminolevulinic acid (5-ALA)-mediated radiodynamic therapy (RDT) has been shown to be an effective treatment option using high-energy photon beams. RDT utilizes tumoricidal capabilities caus...

Investigation of High Cumulative Doses and Dose Outliers in a Pediatric Hospital

Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha

Affiliation: Qaelum NV, Children's National Hospital

Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our “ped...

Investigation of Triggered Imaging and Auto Beam Hold Using a Dynamic Thorax Phantom for Intra-Fraction Motion Management

Authors: Liu Hong, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...

Learning from Failures – Case Studies into Failing Patient Specific Quality Assurance Plans

Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh

Affiliation: Tufts Medical Center

Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...

Mesh-Based Multiregion Model of Adult Human Kidneys for Dosimetric Evaluation of Radiopharmaceutical Therapy

Authors: John P. Aris, Wesley E. Bolch, Chansoo Choi, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Abdul-Vehab Dozic, Amy M. Geyer, Harald Paganetti, Shreya P. Pathak, Julia D. Withrow

Affiliation: St. Luke's Health System, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: The goal of this study was to enhance the accuracy of renal dosimetry in radiopharmaceutical therapy (RPT) by developing a more detailed and precise kidney model. In RPT, accurate dose estima...

Modified Dehazenet for Scatter Correction in Triggered Imaging: Enhancing Visibility and Alignment Precision for Radiation Therapy

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...

Moving Towards Independent Assays of 90y Glass Microsphere Activity: Monte Carlo Simulation with Experimental Data

Authors: Mercy Iyabode Akerele, Yuni K. Dewaraja, Richard Laforest, Justin K. Mikell, Wendy Siman, Allan Thomas, Daniel Thorek

Affiliation: University of Michigan, Washington University School of Medicine in St. Louis, Washington University School of Medicine, University of Colorado Anschutz Medical Campus, School of Medicine, Washington University in St. Louis, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Post-therapy quantitative 90Y SPECT and PET measurements show ~25% lower activity than vendor-reported values for glass microspheres. We hypothesize this discrepancy is due to bremsstrahlung ...

Multicentric Characterization of Organ-Based Tube Current Modulation in Thoracic and Abdominopelvic Computed Tomography: A Dosimetric and Image Quality Study

Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard

Affiliation: Fibermetrix, Alara Expertise, Alara Group

Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...

Novel Use of 3D Printing for Pre-Operative Dose Estimation in the First Case of Gammatile Spine Implantation

Authors: Ali Al Asadi, Amanda Lynn DiCarlo, Anthony J. Doemer, Jessie Y. Huang, Ian Y Lee, Alexandra Moceri, Adam Robin, Lisa Scarpace, Mira Shah, Salim Siddiqui, Kundan S Thind

Affiliation: Henry Ford Innovations, Henry Ford Health

Abstract Preview: Purpose: For a patient who had two previous courses of external beam therapy for rectosigmoid adenocarcinoma and presented with painful, recurrent disease in the sacrum, this study describes the first...

On Estimating Effective Doses Associated with Different Imaging Protocols for Weight-Bearing Imaging of the Hip with a Dedicated Cone Beam CT (CBCT) Scanner

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To estimate effective doses associated with different imaging protocols for hip imaging with a cone beam CT (CBCT) scanner specifically designed for weight-bearing acquisitions.
Methods: A...

Oncoflat: Automated 3D-to-2D Bolus Unfolding Tool for Radiation Therapy

Authors: Jeonghoon Park, Amritha Praveen, Siddhant Sen, James J. Sohn, Ethan D. Stolen

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, The University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago, Department of Psychology, University of Illinois Urbana-Champaign

Abstract Preview: Purpose: Accurate fabrication of custom boluses is essential in radiation therapy to enhance dose delivery to superficial tumors, especially in anatomically complex regions. This study introduces a no...

Optimizing Fractionation Schedules for De-Escalation Radiotherapy in Head and Neck Cancers Using Deep Reinforcement Learning

Authors: Zhongjie Lu

Affiliation: Department of Radiation Oncology, The First Affiliated Hospital, Zhejiang University School of Medicine

Abstract Preview: Purpose: Patients with locally-advanced head and neck squamous cell carcinomas(HNSCCs), particularly those related to human papillomavirus(HPV), often achieve good locoregional control(LRC), yet they ...

Optimizing Motion Management QA: Clinical Integration of Aapm TG-306 for the Radixact Synchrony System

Authors: Hulya Ozdemir Buss, Jeffrey Geiger, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The Radixact Synchrony system integrates real-time motion tracking and compensates to improve treatment accuracy for moving targets. This study presents a streamlined and efficient quality as...

Personalized Anisotropic Margin Strategy for Cervical Cancer Online Adaptive Radiation Therapy

Authors: Jian Chen, Qiufen Guo, Aihua Li, Jing Liu, Junjie MA, Qian WU, Haonan Xiao, Peng Xie, Xiaohui Yan, Yong Yin, Zhe Zhang

Affiliation: Department of Radiation Oncology, Peking University Shenzhen Hospital, Department of Radiation Oncology and Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Obstetrics and Gynaecology, Liao Cheng People’s Hospital

Abstract Preview: Purpose: Online Adaptive radiation therapy (ART) has been an effective technique to manage patient’s inter-fractional anatomical changes and therefore reduces planning target volume (PTV). However, on...

Phantom-Based Dosimetric Comparison of Multiple CT Metal Artifact Reduction Algorithms for Head-and-Neck Radiotherapy

Authors: Loren Bell, Charles S Cathcart, Brett William Eckroate, Harold Y Hu, Joshua Kilian-Meneghin, Ke Nie, Fredrick Warburton, Zhenyu Xiong, Keying (Karen) Xu, Ning J. Yue, Yin Zhang, Lili Zhou

Affiliation: RWJBarnabas Health, Basis Scottsdale, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: This study compares the dosimetric impact of multiple metal artifact reduction (MAR) algorithms from different CT simulator vendors using an anthropomorphic head phantom for head-and-neck (H/...

Planning Study of Spatially Fractionated Radiotherapy (SFRT) for Treating Recurrent Glioblastoma Multiforme (GBM)

Authors: Hyunuk Jung, Fiona Li, Brian Marples, Michael Milano, Sean M. Tanny, Dandan Zheng, Yuwei Zhou

Affiliation: Department of Radiation Oncology, University of Rochester, University of Rochester Medical Center, University of Rochester

Abstract Preview: Purpose:
Recurrent GBM remains one of the most challenging cancers, with limited treatment options. We investigated potential planning parameters of SFRT, a novel radiotherapy technique that delive...

Preclinical Assessment of 68ga-Dotatate As a Surrogate for 177lu-Dotatate Dose Distribution in Radionuclide Therapy

Authors: Payman Hejazi, Faraz Kalantari, Milad Peer-Firozjaei, Romina Pourhashem, Ehsan Tajikmansoury

Affiliation: Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Medical Physics, Semnan University of Medical Sciences, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose:
Pretreatment biodistribution imaging play a crucial role in optimizing tumors and organ absorbed doses estimation in radionuclide therapy. Surrogating radionuclides for more efficient trea...

Predicting Hematologic Toxicity in Advanced Cervical Cancer Patients Using Interpretable Machine Learning Models Based on Radiomics and Dosimetrics

Authors: Qianxi Ni, Qionghui Zhou

Affiliation: The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital, the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University

Abstract Preview: Purpose:
This study aims to develop and evaluate interpretable machine learning models that use radiomic and dosimetric features to predict HT in advanced cervical cancer patients.
Methods:
R...

Prediction of Vertebral Compression Fracture after Stereotactic Body Radiotherapy for Spinal Metastases Using Clinical, Radiomic and Dosiomic Features

Authors: Yukio Fujita, Syoma Ide, Kei Ito, Tomohiro Kajikawa, Satoshi Kito, Keiko Murofushi, Yujiro Nakajima, Yuhi Suda, Kentaro Taguchi, Naoki Tohyama, Fumiya Tsurumaki

Affiliation: Komazawa University Graduate School, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital, Department of Radiology, Kyoto Prefectural University of Medicine

Abstract Preview: Purpose: Stereotactic body radiotherapy (SBRT) for spine metastases is more effective for pain relief and local control than conventional radiotherapy. However, it is associated with vertebral compres...

Predictive Quality of Differing Body Size Measurands for Radiation Risk Estimation in CT Imaging: A Virtual Trial Study

Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...

Preplanning Physics Consultation with Voxelized EQD2: A Proactive Approach for Streamlined Dose Management in High-Risk Re-Irradiation Patients

Authors: Katja M. Langen, Mark McDonald, Bill Stokes, Yinan Wang, Suk Whan (Paul) Yoon

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Effective dose management in high-risk re-irradiation (ReRT) patients entails early, detailed special physics consultation (SPC) to mitigate risks from cumulative radiation dose. SPCs have tr...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≄6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Prostate Dosimetric Comparison between Cyberknife and Radixact Modalities Using Precision and Raystation Planning Systems

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: The Accuray Synchrony real-time motion fiducial tracking solution allows for prostate stereotactic treatment on both Cyberknife and Radixact machines. In our radiotherapy department, two solu...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Radiobiological Modeling of Tumor Control and Normal Tissue Response Following Mlc-Based Sfrt to Extensive Breast and Chest Wall Tumors

Authors: Ramesh Boggula, Yash Somnay, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC, Wayne State University

Abstract Preview: Purpose: Spatially fractionated radiation therapy (SFRT) allows delivery of therapeutic doses to bulky tumors otherwise limited by dose-volume effects that threaten organ-at-risk tolerances. For negle...

Rapid CBCT Imaging with Ultra-Sparse X-Ray Projections for Head & Neck Cancer Radiotherapy

Authors: Hania A. Al-Hallaq, Chih-Wei Chang, Anees H. Dhabaan, Yuan Gao, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Keyur Shah, Sibo Tian, Zhen Tian, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Emory University, Whinship Cancer Institute, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Traditional cone-beam computed tomography (CBCT) often requires multiple angular projections, increasing radiation exposure and extending scanning times, which may lead to heightened patient ...

Recovery Factor Comparisons for Reirradiation Overlapping the Spinal Cord

Authors: Xinxin Deng, Issam M. El Naqa, Jimm Grimm, Lijun Ma, Vitali Moiseenko, Timothy E. Schultheiss, Gopal Subedi, Wolfgang A. Tomé, Ellen D. Yorke, Albert van der Kogel

Affiliation: Montefiore Medical Center, Wellstar Kennestone Hospital Cancer Center, H. Lee Moffitt Cancer Center, Department of Human Oncology, University of Wisconsin–Madison, Department of Radiation Oncology, Wellstar Health System, Radiation Oncology, Keck School of Medicine of USC, Georgia Institute of Technology, University of California San Diego, City Of Hope National Medical Centre, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Reirradiation is increasingly utilized in clinical practice but dose-time recovery factors for human subjects remain uncertain. We constructed a reirradiation recovery model for spinal cord e...

Rectal Spacer Injection on the Day of HDR Prostate Brachytherapy Enhances Dosimetry and Reduces Rectal Dose for Patients Receiving Combined Brachytherapy and EBRT.

Authors: Francis A Asamoah, David D. Campos, Jordan A Holmes, Ke Colin Huang, Omar Ishaq, Sook Kien Ng, Arpan Prabhu, Edwin Quashie, Yong Yue

Affiliation: Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Evaluate a novel rectal spacer workflow with spacer injection during brachytherapy to streamline logistics, reduce hospital visits and costs, and compare the benefits of SpaceOAR Vue and Barr...

Registration of Radiation Simulation 3D Medical Imaging and Cardiac Electrophysiology of Porcine Left Ventricle Using a 17-Segment Model Framework.

Authors: Phillip Cuculich, Geoffrey D. Hugo, Nels C. Knutson, Luke Christian Marut, Eric D. Morris, Stacey Rentschler, Clifford Robinson, Christian Zemlin, Brian Zenger

Affiliation: Washington University School of Medicine in St. Louis, WashU Medicine

Abstract Preview: Purpose: Stereotactic arrhythmia radiotherapy (STAR) is an emerging treatment for ventricular tachycardia (VT) that uses radiation to modulate cardiac electrophysiology (EP) and reduce VT. Registratio...

Retrospective Postimplant Dosimetry: Comparison of Line and Point Source for 131cs Low Dose Rate Intracranial Implant Brachytherapy

Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira

Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center

Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...

Sensitivity of CT Ventilation Imaging to Image Acquisition and Reconstruction Parameters: A Phantom Study

Authors: Hilary Louisa Byrne, Paul J. Keall, John Kipritidis, Jeremy Lim

Affiliation: Northern Sydney Cancer Centre, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose:
Non-contrast CT ventilation imaging (CTVI) has been developed as a cost-effective and accessible alternative to PET/SPECT V/Q imaging for visualizing lung function. However, the sensitivit...

Slit Scanning Delivery Simulation for Flash Radiotherapy

Authors: Muhammad Ramish Ashraf, Dixin Chen, Aaron Garza, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner, Murat Surucu

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: FLASH radiotherapy, supported by robust preclinical evidence showing an improved therapeutic index, is advancing toward clinical trials. Clinical FLASH treatments will likely require scanning...

Small Fields Output Factor Measurements in 1.5 MR-Linac

Authors: Thomas I. Banks, Tsuicheng D. Chiu, Viktor M. Iakovenko, Christopher Kabat, Chang-Shiun Lin, Mu-Han Lin, Arnold Pompos

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: The superior soft-tissue contrast provided by MR imaging offers favorable conditions for the effective application of stereotactic body radiation therapy (SBRT). Accurate small field dosimetr...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

TCP Modeling of Regional Recurrencies and Dose to Nodal GTV after Radiotherapy for Head & Neck Cancer

Authors: Brian M. Anderson, Simon A. Brundage, Xuguang Scott Chen, Shiva K. Das, Felice Dong, Spencer Lynch, Panayiotis Mavroidis, Ryan Morse Morse, Heidi Urquidi

Affiliation: University of North Carolina Chapel Hill, University of North Carolina at Chapel Hill, University of North Carolina

Abstract Preview: Purpose: This study aims at correlating different dosimetric indices of nodal GTV with the regional recurrencies observed after head and neck radiotherapy. Also, to perform a tumor control probability...

Tailor-TS System: Tailored Tumor Segmentation System with Facility-Specific Semi-Supervised Learning

Authors: Gong Vincent Hao, Daisuke Kawahara, Jokichi Kawazoe, Yuji Murakami, Ikuno Nishibuchi, Peiying Colleen Ruan, Daguang Xu, Dong Yang

Affiliation: Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Graduate School of Biomedical and Health Sciences, Hiroshima University, NVIDIA

Abstract Preview: Purpose:
Accurate tumor segmentation in head and neck cancer is critical for effective treatment planning, but variability in practices across medical facilities poses challenges for standardizatio...

Targeted Multi-Criteria Optimization for Rapid Improvement of Organ-at-Risk Dose in the Setting of Prostate Stereotactic Body Radiation Therapy

Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: To utilize multi-criteria optimization (MCO) in a targeted fashion to quickly and easily improve dose to the rectum when treating the prostate with stereotactic body radiation therapy (SBRT)....

The Feasibility of Ethos-Based Pulsed Reduced Dose-Rate (PRDR) Radiotherapy

Authors: Chia-Lung Chien, Renteng Hou, Wen C. Hsi, Faraz Kalantari, Ganesh Narayanasamy, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
PRDR is an effective re-irradiation treatment for patients who have already reached the tolerance dose to their organs at risk (OARs). While PRDR is implemented on TrueBeam by limiting the...

Towards Real-Time Marker-Less Prostate Tracking on Standard Radiation Therapy Systems

Authors: Freeman Jin, Paul J. Keall, Alistair MacDonald, Adam Mylonas, Chandrima Sengupta

Affiliation: Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Image X Institute, School of Health Sciences, University of Sydney

Abstract Preview: Purpose: During radiation therapy, tumours in the prostate may move from the planned treatment position, leading to significant dose deviations above clinical tolerances Surveys have indicated the nee...

Tumor Response to Catalytic Effect of Carbamide Peroxide to Megavoltage Radiodynamic Therapy with 5-Aminolevulinic Acid

Authors: Lili Chen, Dusica Cvetkovic, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Cytotoxicity caused by the reactive oxygen species (ROS) is a mechanism for treating cancer cells in radiation therapy. 5-aminolevulinic acid (5-ALA)-mediated radiodynamic therapy (RDT), whic...

Ukan Architecture for Voxel-Level Dose Prediction in Radiotherapy

Authors: Lu Jiang, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Conventional radiotherapy treatment planning is guided by a set of generic objectives that are unspecific to patient anatomy. Treatment planning thus heavily relies on the planner’s experi...

Uncertainty Analysis for Effective Dose Conversion Factors in CT

Authors: Renxin Chu, Jelena Mihailovic, Kai Yang, Lifeng Yu, Da Zhang

Affiliation: Massachusetts General Hospital, Mayo Clinic, Boston Children's Hospital, UVA Health University Hospital, University of Missouri Health Care

Abstract Preview: Purpose:
A frequently used method to estimate effective dose (ED) in CT is by multiplying the dose length product (DLP) by a conversion factor, known as k-factor. The k-factor in this method is sus...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Utilizing All Acquired Images from Fluoroscopically-Guided Interventions: Test Application with Event-By-Event Patient Dosimetry Calculations

Authors: Sagine Berry-Tony, Lasya Daggumati, James R Duncan, Melak Senay, Allan Thomas

Affiliation: University of Missouri-Kansas City School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: Most acquired images in FGIs are not permanently archived. In the context of modern computational prowess, novel improvements to FGI practice likely sit just under the surface of large-scale ...

Validation and Benchmarking of Mirdct Software for Organ Dose Estimation in Routine CT Protocols

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Gunjan Kayal, Adam Leon Kesner, Harry Marquis, Juan Camilo Ocampo Ramos, Stefan Wehmeier

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: Accurate organ dose estimation in computed tomography (CT) has gained attention due to the increasing global utilization of CT imaging. MIRDct, a specialized CT dosimetry software, has recent...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...

Voxel-Based Micro-Yucatan Minipig Phantoms for Use in Internal Dosimetry

Authors: John P. Aris, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Ann M. Chan, Chansoo Choi, Aitor Gallastegui Menoyo, Rowan James Milner, Bangho Shin, Maria M. Von Chamier

Affiliation: University of Florida

Abstract Preview: Purpose: In preclinical studies, minipigs serve as valuable experimental models for predicting absorbed doses due to their anatomical and physiological similarities to humans. However, minipig computa...