Search Submissions 🔎

Results for "electron proton": 39 found

A Dual Energy CT-Guided Intelligent Radiation Therapy Platform

Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...

A Pilot Survey on Medical Physics Residency Education in External Beam Special Procedures

Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng

Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester

Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

Assessment of the Quantum-CMOS Image Sensor for Use in Cherenkov Imaging during Radiation Therapy

Authors: Petr Bruza, Jeremy Eric Hallett, Brian W Pogue

Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Cherenkov imaging is a powerful tool for localizing entrance and exit dose during radiotherapy treatment. The current implementation uses an intensified-CMOS (iCMOS) camera allowing for high-...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Characterization of Image Intensified Cherenkov Cameras for Development of Direct CMOS-Based Detection Systems

Authors: Petr Bruza, Eric R. Fossum, Alexander Geiersbach, David J. Gladstone, Karthik Raj Venkatesan

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Current Cherenkov imaging sensors rely on image intensifiers to generate sufficient signal for photon detection. While image intensifiers (IIs) exhibit good Cherenkov photon signal response, ...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterization of a Prototype Flashdiamond Detector for Conventional and Uhdr Beams

Authors: Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose:
To evaluate the dose rate dependence, beam quality dependence, and short-term stability of a novel flashDiamond (fD) prototype detector for conventional and ultra-high dose rate (UHDR) bea...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Compact Representation of External Beam Photon Phase Space Data Via Implicit Neural Representation Learning

Authors: Serdar Charyyev, Cynthia Fu-Yu Chuang, Veng Jean Heng, Lianli Liu, Lei Xing, Yong Yang

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: To replace large finite-size photon phase space files with a compact neural network capable of generating an infinite number of particles.
Methods: Three separate models were developed to ...

Comprehensive Study of Recombination and Polarity Factors across CC04, CC13, FC65P, FC65G, Razor, and PP05 Chambers

Authors: Ziyad ABUBAKR ALHAREESHi, Ibtihaj Yussef Alhodire, Najla Sobhi Bin Shehima, Aram Mufteh A Genaw

Affiliation: Tripoli university hospital

Abstract Preview: Purpose:
This research investigates the recombination and polarity correcting factors for CC04, CC13, FC65P, FC65G, Razor, and PP05 ionization chambers to improve radiation dosimetry accuracy. Unde...

Correcting for the Cherenkov-to-Dose Conversion for Tset Patients Using Monte Carlo Simulations

Authors: Baozhu Lu, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: Cherenkov intensity can be quantitatively correlated to surface dose but need certain corrections for accurate dose measurements. This study aims to investigate the impact of incident beam an...

Deployable Twin-Calorimeter System for Absolute Dose Measurements By Clinical Physicists

Authors: Jean Dessureault, Malcolm R. McEwen, Bryan R. Muir, James Renaud

Affiliation: National Research Council

Abstract Preview: Purpose: To develop and commission a mailable calorimeter that enables clinical medical physicists to quickly and efficiently address innovative dosimetry challenges directly at the point of use.
<...

Differential Gastrointestinal Responses to Synchrotron-Produced Proton and Electron Irradiation Under Flash and Conventional Conditions

Authors: Luke Connell, Nolan M. Esplen, Elise Konradsson, Albert C. Koong, Ziyi Li, Steven Hsesheng Lin, Kevin Liu, Billy W Loo, Devarati Mitra, Radhe Mohan, Emil Schueler, Takeshi Takaoka, Uwe Titt, Xiaochun Wang, Ming Yang

Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study aimed to assess radiation-induced gastrointestinal (GI) toxicity in mice subjected to abdominal irradiation using protons at ultra-high-dose-rate (UHDR) and conventional dose-rates...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectors™ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Efficient Monte Carlo Simulation of Radiation-Induced Double Strand Break Production and Repair Kinetics

Authors: Zakaria Aboulbanine, Greeshma A. Agasthya, Paul Inman, Anuj J. Kapadia, Anthony Hong Cheol Lim, Jayasai Ram Rajagopal, Chris C. Wang

Affiliation: Oak Ridge National Laboratory, Georgia Institute of Technology

Abstract Preview: Purpose: Radiobiological simulation via TOPAS-nBio requires significant computational resources and time to provide meaningful results. This study aims to decrease simulation time and computational re...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Feasibility of Producing GRID Therapy Dosimetry Using a Compact Linac Treatment Head with Pencil Beam Scanning

Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin

Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

Generation of Patient-Specific Phantom for Head & Neck Proton Therapy Based on Xcat

Authors: Cheng-En Hsieh, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu, An-Ci Yang

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose:
The aim of this study is to develop a framework of generating patient-specific phantom tailored for head and neck proton therapy. From these phantoms, digital reference objects based on th...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Impact of Tissue Heterogeneity on Proton LET and RBE Distributions: A Monte Carlo Study

Authors: Xiangli Cui, Wei Han, Jie Li, Lingling Liu

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences

Abstract Preview: Purpose: To investigate the influence of tissue heterogeneity on proton beam linear energy transfer (LET) and relative biological effectiveness (RBE) using nine RBE models. This study quantifies the i...

Investigation on Quantifying Chemical Species Post Electron and Proton Irradiation Using the Geant4-DNA 'UHDR' Example

Authors: Konstantinos Chatzipapas, George C. Kagadis, Panagiotis Konstas, Dimitris N. Mihailidis, Dimitris Visvikis

Affiliation: LaTIM, INSERM UMR1101, University of Pennsylvania, LaTIM, INSERM, University of Brest, University of Patras

Abstract Preview: Purpose: This study investigates the temporal evolution of radiolytic species (H3O+, OH•, OH-) in water under electron and proton irradiation using the mesoscopic chemistry model that allows longer te...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Radiation Shielding Considerations for Ultra-High Dose Rate Electron Flash Radiation Therapy

Authors: Alexandru Badalan, Peter Petric, I. Antoniu Popescu, Andrew Kyle Henderson Robertson

Affiliation: Bc Cancer, BC Cancer - Vancouver, BC Cancer

Abstract Preview: Purpose: Ultra-high dose rate (>40 Gy/s) or “FLASH” radiation therapy (RT) has the potential to improve cancer treatment through reduced radiation side effects. While electron FLASH beams can be produ...

Remote Evaluation of Flash Beamlines for Electron, Proton, and MV Photons

Authors: Alexander Baikalov, Luke Connell, Nolan M. Esplen, Michele M. Kim, Stephen F. Kry, Emil Schueler, Hayden Scott, Ryan Sun, Paige A. Taylor, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, University of Pennsylvania, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: to develop an affordable, portable device for accurately measuring FLASH dose rates from protons, electrons, and photons. 4 detectors were utilized to measure the temporal structure of proton...

Secondary Neutron Dosimetry of Cieds Exposed to Neutron-Producing Photon Radiation Therapy

Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin

Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...

Slit Scanning Delivery Simulation for Flash Radiotherapy

Authors: Muhammad Ramish Ashraf, Dixin Chen, Aaron Garza, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner, Murat Surucu

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: FLASH radiotherapy, supported by robust preclinical evidence showing an improved therapeutic index, is advancing toward clinical trials. Clinical FLASH treatments will likely require scanning...

The Topas Monte Carlo Framework – Status and Outlook after 15 Years of Development

Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Thongchai Masilela, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin

Affiliation: University of California San Francisco, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital

Abstract Preview: Purpose: To present the results of 15 years of developments of the TOPAS TOol for PArticle Simulation framework, and to highlight recent and new developments.

Methods: Fundamental understanding...

Two's Company, Three's a Crowd? a Bayesian Approach to Optimizing the Number of Measurement Readings in Radiation Therapy QA

Authors: Siyong Kim, Ava Paek, Joseph B. Schulz, James J. Sohn, Eric D. Stolen, Ethan D. Stolen

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Virginia Commonwealth University, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: The American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) guidelines recommend three measurements during monthly quality assurance to keep results within two standard de...

Ultra-Fast Commissioning and Quality Assurance with Plastic Scintillation Detector

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: Accurate, efficient, and reliable commissioning of linear accelerator (LINAC) is critical for ensuring high-quality radiation therapy treatments. The study uses advanced detector technology a...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Virtual Monoenergetic Imaging for Radiotherapy: A Single CT Acquisition for Both Target Delineation and Dose Calculation

Authors: Harold Y Hu, Yanle Hu, Shuai Leng, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Basis Scottsdale, Mayo Clinic

Abstract Preview: Purpose: Radiotherapy CT simulation often requires two scans: a non-contrast scan for dose calculation and a contrast-enhanced scan for target delineation. Photon-counting-detector (PCD) CT allows the...