Authors: Sean L. Berry, Hsiang-Chi Kuo, Seng Boh Gary Lim, Ingrid Valencia Lozano, Laszlo Voros
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
To quantify the impact of target degradation on 6FFF beam output by analyzing the output trends and adjustment frequencies at our clinic on a flattening filter-free (6FFF) and a flattened ...
Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...
Authors: James Robert Castle, Joshua Misa, Damodar Pokhrel, William St. Clair
Affiliation: University of Kentucky, Department of Radiation Medicine
Abstract Preview: Purpose: We propose a novel methodology for lattice deployment in spatially fractionated radiotherapy (SFRT), using principal component analysis (PCA) to improve sphere packing within the tumor. Impro...
Authors: Zhenzhen Dai, Anthony J. Doemer, Ryan Hall, Kenneth Levin, Bing Luo, Benjamin Movsas, Karen C. Snyder, Kundan S Thind, Eleanor Walker
Affiliation: Henry Ford Health, HFHS
Abstract Preview: Purpose: To investigate the feasibility of a predictive tool for efficient allocation of hypofractionated whole-breast irradiation patients between Varian Truebeam and Ethos systems.
Methods: A ful...
Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing
Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies
Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.
Methods: The novel shielded and unshielded sili...
Authors: Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali
Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council
Abstract Preview: Purpose:
To evaluate the dose rate dependence, beam quality dependence, and short-term stability of a novel flashDiamond (fD) prototype detector for conventional and ultra-high dose rate (UHDR) bea...
Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé
Affiliation: Montefiore Medical Center
Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...
Authors: Michalis Aristophanous, Steven Blum, Laura I. Cervino, Antonio L. Damato, Karen Episcopia, Chi Huang, Shih-Chi Lin, Michelle K. Savacool
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Varian Ethos (Varian Medical Systems, Palo Alto, CA) is a 6 MV flattening-filter-free (FFF) only machine, posing a challenge in creating homogeneous dose distributions when using manual 3D-CR...
Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...
Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov
Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital
Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...
Authors: Serdar Charyyev, Cynthia Fu-Yu Chuang, Veng Jean Heng, Lianli Liu, Lei Xing, Yong Yang
Affiliation: Department of Radiation Oncology, Stanford University
Abstract Preview: Purpose: To replace large finite-size photon phase space files with a compact neural network capable of generating an infinite number of particles.
Methods: Three separate models were developed to ...
Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma
Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC
Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...
Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani
Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...
Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...
Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa
Affiliation: National Cancer Centre Singapore
Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...
Authors: Kaile Li
Affiliation: Alexander T. Augusta Miliary Medical Center
Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...
Authors: Aliasghar Rohani, Rui Zhang
Affiliation: Louisiana State University, Baton Rouge, Louisiana, Department of Radiation Oncology, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: This study aimed to evaluate the impact of simultaneous optimization of multi-photon beam energy and fluence on IMRT and VMAT treatment planning.
Methods: An Elekta linear accelerator (lin...
Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé
Affiliation: Montefiore Medical Center
Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...
Authors: Michael J. Choi, Vindu Wathsala Kathriarachchi, Christopher L. Nelson, Andrew P. Soderstrom, Yawei Zhang
Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, UF Health Proton Therapy Institute
Abstract Preview: Purpose: Cone Beam Computed Tomography (CBCT) is widely used in image-guided radiation therapy for patient positioning. While kV photons offer high image contrast, they are prone to artifacts caused b...
Authors: Grace Hutchinson, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin
Affiliation: Iowa Health Care, University of Iowa
Abstract Preview: Purpose: To assess the feasibility and consistency of the Sun Nuclear Corporation (SNC) MR conditional Quad Wedge, as an accessory to the IC Profiler-MR, and to evaluate beam output and energy in the ...
Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin
Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...
Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao
Affiliation: University of Miami
Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...
Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma
Affiliation: University of California San Francisco, University of California, San Francisco, University of California
Abstract Preview: Purpose: Introduced in 2018, the Varian Halcyon platform has increased in popularity due to its reduced cost, user-friendly design, and operational efficiency. As this platform ages, major repairs, in...
Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...
Authors: Jacqueline M. Andreozzi, Savannah Decker, Diego Hernandez, Iman R. Washington
Affiliation: UC San Diego, Department of Radiation Oncology, Moffitt Cancer Center, University of South Florida, Moffitt Cancer Center
Abstract Preview: Purpose: Recent advances in external beam radiation therapy have begun to explore the utility of Cherenkov radiation imaging as a beam delivery visualization tool. When sheet bolus is used during trea...
Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...
Authors: Kaitlyn M Betz, David Dunkerley, Eric Johnson, Kalina V Jordanova, Kathryn E. Keenan, Samuel D Oberdick, Gregory P. Penoncello, Stephen E Russek
Affiliation: Dept of Radiology, Stanford, University of Colorado School of Medicine, NIST, College of Wooster
Abstract Preview: Purpose: Examine use of low-field MRI and multiparametric analysis for 3D MRI-readable biomimetic gel dosimetry. Low-field MRIs are compact, inexpensive, and portable. They could be located within rad...
Authors: Larry A. DeWerd, Ahtesham Ullah Khan
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison
Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...
Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...
Authors: Siyong Kim, Ava Paek, Joseph B. Schulz, James J. Sohn, Eric D. Stolen, Ethan D. Stolen
Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Virginia Commonwealth University, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: The American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) guidelines recommend three measurements during monthly quality assurance to keep results within two standard de...
Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions
Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...
Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)
Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...
Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao
Affiliation: Varian AOS @Epic Care, UC Berkeley
Abstract Preview: Purpose: To quantity variations in Winston Lutz (WL) test results due to different energies used in SBRT, SRT or SRS.
Methods: A WL phantom with a 6.4 mm diameter center radio-opaque sphere is used...