Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega
Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...
Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...
Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal
Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...
Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University
Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...
Authors: Shaojie Chang, Thomas A. Foley, Hao Gong, Emily Koons, Shuai Leng, Cynthia H. McCollough, Eric E. Williamson
Affiliation: Mayo Clinic
Abstract Preview: Purpose: To enhance coronary CT angiography (cCTA) capabilities on conventional energy integrating detector CT (EID-CT) using artificial intelligence (AI). The AI framework incorporates high-resolutio...
Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou
Affiliation: Cedars-Sinai Medical Center
Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...
Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...
Authors: Paul Boisseau, Eric S. Diffenderfer, Andrew Friberg, Wenbo Gu, Matthew Nichols, Kan Ota, Xiaokun Teng, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou
Affiliation: Department of Radiation Oncology, University of Pennsylvania, Pyramid Technical Consultants, Inc., University of Pennsylvania
Abstract Preview: Purpose: Traditional quality assurance procedures for proton pencil beam energies involve water tank setups or multiple solid water phantoms and are time-consuming. This study demonstrates that an inn...
Authors: Jorge Naoki Dominguez Kondo, Qihui Lyu
Affiliation: University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Targeted alpha therapy (TAT) has emerged as a highly potent therapeutic method in oncology, but its development is limited by the lack of imaging methods to quantify its dosimetry. Convent...
Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani
Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...
Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...
Authors: Soo Hyun Byun, Troy Farncombe, Edcer Jerecho DC Laguda
Affiliation: McMaster University
Abstract Preview: Purpose: We present the adaptation of a Cadmium Zinc Telluride (CdZnTe) detector, initially designed for SPECT-MR applications, to neutron imaging. This study explores a novel technique that utilizes ...
Authors: Ehsan Abadi, Njood Alsaihati, Steven T. Bache, Mridul Bhattarai, Cindy Marie McCabe, Francesco Ria, Ehsan Samei
Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Duke University Health System, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: To compare and contrast alternative methods including reader (in hominum), phantom (in phantasma), in vivo, and in silico methods deployed to assess the performance of photon counting (PCCT) ...
Authors: Michael Dingfelder, Homeira Faridnejad
Affiliation: East Carolina University, Department of Physics, East Carolina University
Abstract Preview: Purpose: To use Gafchromic film for measurement of the dose delivered by low-energy (2-4 MeV) protons to living cells.
Methods: Five different types of Gafchromic films were tested for dosimetry un...
Authors: Michael J. Choi, Vindu Wathsala Kathriarachchi, Christopher L. Nelson, Andrew P. Soderstrom, Yawei Zhang
Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, UF Health Proton Therapy Institute
Abstract Preview: Purpose: Cone Beam Computed Tomography (CBCT) is widely used in image-guided radiation therapy for patient positioning. While kV photons offer high image contrast, they are prone to artifacts caused b...
Authors: Leshan Sun, Liangzhong Xiang, Yifei Xu, Yuchen Yan
Affiliation: University of California, Irvine
Abstract Preview: Purpose: X-ray Acoustic Computed Tomography (XACT) is a transformative innovation in medical imaging, overcoming the limitations of conventional X-ray techniques. It introduces new possibilities in cl...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal
Affiliation: Radboud University Medical Center, University of São Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin
Abstract Preview: Purpose: This study aimed to evaluate the precision and accuracy of volume measurements for solid nodules (SNs) and ground-glass opacities (GGOs) in lung images acquired using energy-integrating CT (E...
Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...
Authors: Ciprian N. Ionita, Parisa Naghdi, Ahmad Rahmatpour
Affiliation: University at Buffalo, SUNY: University at Buffalo
Abstract Preview: Purpose: Quantitative angiography (QA) evaluates neurovascular hemodynamics, but is affected by X-ray parameters, vessel foreshortening, and imaging chain factors like detector efficiency, pixel size,...
Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao
Affiliation: University of Miami
Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...
Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana
Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East
Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...
Authors: Ramesh Boggula, Jay W. Burmeister
Affiliation: Wayne State University, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine
Abstract Preview: Purpose: This study evaluated the performance of a hybrid Compton camera for real-time imaging during the administration of Lu-177-based radiopharmaceuticals, including Pluvicto and Lutathera. The aim...
Authors: Xinhua Li, Jie Zhang, Yifang (Jimmy) Zhou
Affiliation: University of Kentucky, Cedars-Sinai Medical Center
Abstract Preview: Purpose: Fat volume fraction (FVF) is an important biomarker for non-alcoholic fatty liver disease. CT can be a good modality for FVF assessment if the accuracy is adequate. We aimed to study the impa...
Authors: Mohammadreza Ay, Nahal Daneshgar, Nima Kasraie, Abbas Monsef, Zeinab Peymani, Hadi Rezaei, Peyman Sheikhzadeh
Affiliation: University of Minnesota Medical School, Radiation Oncology, Department of Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Shiraz University of Medical Sciences, Department of Medical Physics, Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, UT Southwestern Medical Center, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences
Abstract Preview: Purpose:
This study aims to design and simulate an innovative pediatric-dedicated SPECT scanner optimized for children’s unique anatomical and safety needs by enhancing sensitivity in data acquisit...
Authors: Qihui Lyu, Javier Caravaca Rodriguez, Youngho Seo, Ke Sheng, Jingjie Yu
Affiliation: University of California San Francisco, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Simultaneous broad-energy imaging is critical for many theragnostic applications, but the current Single-Photon Emission Computed Tomography (SPECT) can only image low energy photons with ...
Authors: Saree Alnaghy, Owen Thomas Dillon, Sean P Hood, Paul J. Keall, Ricky O'Brien, Tess Reynolds
Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney, University of Wollongong, Medical Radiations, School of Health and Biomedical Sciences, RMIT University
Abstract Preview: Purpose: Photon Counting Detectors (PCDs) have been demonstrated to improve resolution, contrast and lesion detectability in fan-beam CT. There is naturally a desire to bring these improvements to Con...
Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University
Abstract Preview: Purpose: Contrast-enhanced breast cone-beam computed tomography (bCBCT) provides high-resolution, 3D imaging of breast tissues with improved differentiation between normal and abnormal tissues. Curren...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal
Affiliation: Radboud University Medical Center, University of São Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin
Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...
Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink
Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems
Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...
Authors: Magdalena Bazalova-Carter, Ross I. Berbeco, James Day, Xinchen Deng, Chelsea Amanda Saffron Dunning, Dianne M. Ferguson, Matthew W. Jacobson, Toby Morris, Marios Myronakis, Jericho Daniel O'Connell, Fides Schwartz, Jainil Shah, Aaron Sodickson
Affiliation: Brigham and Womens Hospital, University of Massachsetts Lowell and Dana-Farber Cancer Institute Boston, Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Washington, University of Victoria, Siemens Healthineers, Dana Farber/Brigham and Women's Cancer Center, Brigham and Women's Hospital
Abstract Preview: Purpose: While CT imaging has advanced with improved machine design, we propose further gains can be achieved by enhancing sensitivity to contrast agents. Current CT sensitivity is limited to 1% bismu...
Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz
Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)
Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...
Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din
Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University
Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...
Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou
Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...
Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq
Affiliation: Khalifa University
Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...
Authors: Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose: Conventional computed tomography (CT) measures the collective attenuation of primary photon fluence and then reconstructs the 3D images without using the timing information of individual phot...
Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...
Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania
Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...
Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed
Affiliation: Bay Pines VA Medical Center
Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...