Search Submissions 🔎

Results for "enhanced leaf": 28 found

23na Magnetic Resonance Imaging k-Space Denoising

Authors: Lorenzo Arsini, Andrea Ciardiello, Fabio Massimo D'Amore, Stefano Giagu, Federico Giove, Carlo Mancini-Terracciano, Cecilia Voena

Affiliation: Istituto Superiore di Sanità, Sapienza University of Rome, Università Sapienza Roma, Magnetic Resonance for Brain Investigation Laboratory, Museo Storico della Fisica e Centro di Studi e Ricerche Enrico Fermi

Abstract Preview: Purpose: To leverage newly developed heteronuclear magnetic resonance imaging (MRI) techniques, particularly sodium (23Na) imaging, for identifying potential biomarkers of Alzheimer's disease—such as ...

AI-Based Registration-Free 3T T2-Weighted MRI Synthesis Using Truefisp MRI Acquired on a 0.35T MR-Linac System

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Cynthia Fu-Yu Chuang, Yu Gao, Dimitre Hristov, Lianli Liu, Lawrie Skinner, Lei Xing

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose:
MR-guided radiation therapy has introduced a significant leap in cancer treatment by allowing adaptive treatment. The low-field MR-guided system predominantly uses the TrueFISP sequence, w...

Assessment of Radiation Protection Knowledge Among Operation Professional Nurses

Authors: Yu-Ying Lin

Affiliation: Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou

Abstract Preview: Purpose: This study aimed to evaluate the level of radiation protection knowledge among operating room professional nurses.

Methods: A questionnaire was distributed to operating room profession...

Brain Tumor Segmentation from Multi-Parametric MRI with Integrated Evidential Uncertainty Estimation

Authors: Sahaja Acharya, Matthew Ladra, Junghoon Lee, Lina Mekki

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University

Abstract Preview: Purpose: Multi-parametric MRI (mpMRI) is widely used for deep learning (DL)-based automatic segmentation of brain tumors. While multi-contrast images concatenated as channels are typically input to ne...

Centralizing Resources with a Microsoft-Based Wiki Platform: Enhancing Collaboration and Efficiency in Radiation Oncology

Authors: Simon Brundage, Jiajin Fan, Ulrich Langner, Qiongge Li, Jian Liu, Wei Nie, Edwin Quashie, Xiaofeng Zhu

Affiliation: Brown University Health, Hofstra University Medical Physics Program, Inova Hospital, Inova Schar Cancer Institute, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Managing departmental policies, clinical protocols, QA procedures, workflows, and troubleshooting documentation is critical in radiation oncology. A Microsoft-based wiki platform was devel...

Comparison of Mlc Off-Axis Characteristics for Eclipse AAA v18 and v16 Using Portal Dosimetry

Authors: Junsheng Cao, Khushdeep Singh

Affiliation: Overlook Medical Center

Abstract Preview: Purpose: Eclipse v18 introduces Enhanced Leaf Modeling for MLCs. This study investigates the MLC off-axis characteristics using portal dosimetry
Methods:
MLC characteristics were analyzed for th...

Diffusion-Based PET Image Enhancement in Bgrt

Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie

Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The RefleXion® X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...

Dose Mapping of Radioactive Gold Nanoparticles Using Three-Dimensional Dosimetry

Authors: Ana Laura Burin, Maysa Müller Ferreira Gesserame, David Alexander Urbina Leal, Ilca Marli Moitinho Amaral Medeiros, Silas Leonel Pereira Miranda, Thuany Corrêa Nogueira, Maria da Penha Alburquerque Potiens, Pedro Henrique Ricardo, Maria Eduarda Zaganin Rigo, Orlando Rodrigues, Priscila Santos Rodrigues, Wilmmer Alexander Arcos Rosero, Maria Elisa Chuery Martins Rostelato, Sabrina Spigaroli Sgrignoli, Ana Catarina Koka de Souza Silva, Cristhian Ferreira Talacimon, Paulo Victor dos Santos Tavares, Lara El Hajj Teodoro, Carlos Alberto Zeituni, José Neres de Almeida

Affiliation: IPEN - USP

Abstract Preview: Purpose: Perform three-dimensional dosimetry of radioactive gold nanoparticles (¹⁹⁸AuNPs) using Fricke xylenol gel (FXG), aiming to determine the dose distribution and evaluate the method's effectiven...

Dosimetric Evaluation of Enhanced Dynamic Leaf Gap Modeling in Small-Field Clinical Plans: A Verification Study

Authors: Ian J. Butterwick, Sumudu Katugampola, ChangSeon Kim, Evan G. Meekins, Zhengdong Zhang

Affiliation: Mount Sinai Beth Israel, Gesinger Medical Center, Geisinger Medical Center

Abstract Preview: Purpose: To evaluate the dosimetric impact of enhanced dynamic leaf gap (EDLG) modeling in Eclipse V18.0 on small-field dosimetry within VMAT plans.
Methods: Plans with small fields (1 cm x 1 cm to...

Dosimetric Impact of Catheter Length Changes in HDR Brachytherapy for Accelerated Partial Breast Irradiation

Authors: Dylan Richeson, Dorin A. Todor

Affiliation: Inova Schar Cancer Institute, Virginia Commonwealth University

Abstract Preview: Purpose: High dose-rate (HDR) brachytherapy is prone to errors that can lead to incorrect dose delivery and potential medical events. One common issue is applicator length discrepancies, either due to...

Early Evaluation Study for Stereotactic Adaptive Radiotherapy for Pancreatic Cancer with Ethos 2.0 System

Authors: Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Rojano Kashani, Kyle O'Carroll, Gisele Castro Pereira, Christian Erik Petersen, Alex T. Price, Meiying Xing, Reine abou Zeidane

Affiliation: university hospital, University Hospitals Seidman Cancer Center

Abstract Preview: Purpose:
Experimental data have shown the inconsistent monitor unit and target coverage in Ethos 1.1. This can lead to inaccurate dose delivery, compromising patient safety and treatment outcomes. ...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Enhanced Prediction of Iroc Stereotactic Radiosurgery Phantom Audit Results with Treatment Parameters, Complexity Metrics, DVH, and Dosiomics Using Machine Learning

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Christine Peterson, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop predictive models for IROC SRS head phantom audits and to identify important factors influencing institutional performance.
Methods: The IROC SRS head phantom includes two TLDs ...

Enhanced Surface Dose Accuracy in Proton Treatment Planning: Optimizing External Volume HU Thresholding.

Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez

Affiliation: University of Miami

Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...

Enhancing Radiation Therapy Precision and Safety: The Role of Cherenkov Imaging in Clinical Practice.

Authors: Adi Robinson, Michael J. Tallhamer

Affiliation: Centura Health, AdventHealth Orlando

Abstract Preview: Purpose: This study aims to evaluate the integration of Cherenkov imaging into radiation therapy practices, focusing on its utility in enhancing treatment precision, patient safety, and clinical decis...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: Clínica Iram, Clinica Alemana, Hospital Clínico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Evaluating the Impact of an Average Versus Machine-Specific Dosimetric Leaf Gap on Dose Calculation

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: The newest version of a large commercial treatment planning system (TPS) has introduced a new physical MLC model. We compare the impact of using an averaged dosimetric leaf gap (DLG) value ve...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

Identification of Potential Patients for Resimulation and Adaptive Planning By Machine Learning

Authors: Mark Ashamalla, Renee Farrell, Jinkoo Kim, Kartik Mani, Xin Qian, Samuel Ryu, Yizhou Zhao

Affiliation: Stony Brook Medicine, Stony Brook University Hospital

Abstract Preview: Purpose: Adaptive planning is increasingly used in head and neck radiation therapy due to factors like tumor response or changes in patient anatomy. However, methods such as resimulation or offline re...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Intraoperative Dynamic Contrast-Enhanced Fluorescence Imaging in Quantifying Tissue Perfusion of Amputation Patients

Authors: Logan M. Bateman, Xu Cao, Jonathan T. Elliott, Lillian A. Fisher, Ida Leah Gitajn, Xinyue Han, Eric R. Henderson, Shudong Jiang, Jessica M. Sin, Yue Tang

Affiliation: Dartmouth College, Dartmouth-Hitchcock Medical Center

Abstract Preview: Purpose: Adequate tissue perfusion is essential for fracture healing and infection prevention, as it supplies oxygen, nutrients and antibiotics to the injury area. However, current methods of assessin...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varian’s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

Neural Network Based Differentiable Optimization for Volumetric Modulated Arc Therapy (VMAT)

Authors: Peng Dong, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University

Abstract Preview: Purpose: Volumetric Modulated Arc Therapy (VMAT) optimization is a complex, non-convex problem with numerous variables and intricate constraints. Traditional optimization methods often lack efficiency...

Optimized Dosimetric Planning for Trigeminal Neuralgia Using Cyberknife S7 Precision TPS with Volo Optimizer

Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...

Quantitative Evaluation of Eclipse’s (V18) Ability to Address Dosimetric Leaf Gap Variations

Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang

Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...

Rapid CBCT Imaging with Ultra-Sparse X-Ray Projections for Head & Neck Cancer Radiotherapy

Authors: Hania A. Al-Hallaq, Chih-Wei Chang, Anees H. Dhabaan, Yuan Gao, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Keyur Shah, Sibo Tian, Zhen Tian, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Emory University, Whinship Cancer Institute, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Traditional cone-beam computed tomography (CBCT) often requires multiple angular projections, increasing radiation exposure and extending scanning times, which may lead to heightened patient ...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Web-Based Tool for CT Ring Artifact Identification Using Streamlit and Python

Authors: Sarah Huo, David Zander, Wei Zhou

Affiliation: Cherry Creek High School, University of Colorado Anschutz Medical Campus, University of Colorado Anschutz Medical Campus, School of Medicine

Abstract Preview: Purpose:
Ring artifact is commonly seen in CT, and it is usually caused by detector element failure or miscalibration. Although many ring artifacts are apparent and easy to recognize, those origina...