Search Submissions 🔎

Results for "errors highest": 31 found

A Hybrid 4π-Proton Arc Robust Optimization

Authors: Wenhua Cao, Xianjin Dai, PhD, Hadis Moazami Goudarzi, Gino Lim, Miaolan Xie, Lei Xing, Lewei Zhao

Affiliation: University of Chicago Booth School of Business, Department of Radiation Oncology, Stanford University, Department of Industrial Engineering, University of Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) delivers a continuous dose of radiation during gantry rotation. 4π is a non-coplanar technique used for advanced proton therapy delivery. This work proposes a hybrid ...

A Multi-Regional and Multi-Omics Approach to Predict Penumonitis in Patients with Locally Advanced Non-Small Cell Lung Cancer in Nrg Oncology Trial RTOG 0617

Authors: Katelyn M. Atkins, Indrin J. Chetty, Elizabeth M. McKenzie, Taman Upadhaya, Samuel C. Zhang

Affiliation: Department of Radiation Oncology,Cedars-Sinai Medical Center, Cedars-Sinai Medical Center

Abstract Preview: Purpose:
We explored a multi-regional and multi-omics approach to extract CT-based radiomics and 3D dosiomics features to predict radiation pneumonitis (RP) in patients with locally advanced Non-Sm...

A Novel 2D Scintillation Dosimeter Using Long Scintillating Fibers.

Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval

Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...

A Risk Assessment Approach to Photon Reference Dosimetry Using TG-100 Methodology

Authors: Ila Farhang, Ryan D. Foster, Devin Heitz, Jordan B Lunsford, Ashkan Shafiee

Affiliation: Atrium Health Wake Forest Baptist, Atrium Health/LCI Cabarrus

Abstract Preview: Purpose: American Association of Physicists in Medicine (AAPM) Task Group (TG) -51 is a widely utilized protocol for the absolute calibration of linear accelerators. The purpose of this project was fo...

Analyzing Backlight Runtime and Corresponding Performance in Diagnostic Displays

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the correlation between the backlight runtime in diagnostic displays and their corresponding performance, which may aid in making informed decisions regarding the timi...

Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Assessment of Alpha-Fetoprotein As a Prognostic Factor of Overall Survival for HCC Patients Undergoing 90Y-Glass Trans-Arterial Radioembolization

Authors: Srinivas Cheenu Kappadath, James Long, Armeen Mahvash, Anna Marks, Ajalaya Teyateeti

Affiliation: Mahidol University, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Alpha-fetoprotein (AFP) has been implicated as prognostic factor of overall survival (OS) for hepatocellular carcinoma (HCC). We present a statistical approach to determine optimal AFP-cut...

Comparative Evaluation of Nn-Unet Models for Radiotherapy Dose Prediction Using the Head and Neck Cancer Patients

Authors: Theodore Higgins Arsenault, Beatriz Guevara, Rojano Kashani, Raymond F. Muzic, Gisele Castro Pereira, Alex T. Price

Affiliation: University Hospitals Seidman Cancer Center, Case Western Reserve University Department of Biomedical Engineering

Abstract Preview: Purpose: Accurate dose prediction in radiotherapy is essential for treatment planning. This study evaluates four nnUnet-based models using the OpenKBP head and neck dataset: a baseline model (Model 1)...

Construction and Application Study of a Deep Learning-Based Iscout-Guided Precision Radiotherapy Positioning Error Prediction Model for Breast Cancer

Authors: Fangfen Dong, Jiaming Li, Xiaobo Li, Weipei Wang, Zhixin Wang, Bing Wu, Benhua Xu, Yong Yang, Yifa Zhao

Affiliation: Department of Radiation Oncology, Fujian Medical University Union Hospital/Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematologi, Zhangpu County Hospital, School of Medical Imaging, Fujian Medical University

Abstract Preview: Purpose: To explore the construction and clinical application value of a deep learning-based positioning error prediction model, providing a reference for optimizing iSCOUT system-guided precision rad...

Deep-Learning Convolutional Neural Network-Based Breast Cancer Localization for Mammographic Images: A Study on Simulated and Clinical Images

Authors: Xiaoyu Duan, Xiang Li, Wenbo Wan, Lei Zhang, Yiwen Zhang

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Breast screening has been proved to reduce breast cancer mortality by early detection and treatment for patients. Mammography is the most common and widely used technique for breast cancer sc...

Dual-Domain Neural Network Cone-Beam CT Correction for Online Adaptive Proton Therapy

Authors: Daniel H. Bushe, Arthur Lalonde, Hoyeon Lee, Harald Paganetti, Brian Winey

Affiliation: Universite de Montreal, Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School, University of Hong Kong

Abstract Preview: Purpose: Improving the precision and fidelity of daily volumetric imaging is essential for enabling adaptive proton therapy (APT). While cone-beam CT (CBCT) provides daily volumetric imaging, their ut...

Enhanced Prediction of Iroc Stereotactic Radiosurgery Phantom Audit Results with Treatment Parameters, Complexity Metrics, DVH, and Dosiomics Using Machine Learning

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Christine Peterson, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop predictive models for IROC SRS head phantom audits and to identify important factors influencing institutional performance.
Methods: The IROC SRS head phantom includes two TLDs ...

Evaluating Uncertainty Estimation Models for Clinical Integration of AI-Generated Radiotherapy Dose Distributions

Authors: Jacob S. Buatti, Kristen A. Duke, Malena Fassnacht, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia, Michelle de Oliveira

Affiliation: The University of Texas San Antonio, UT Southwestern Medical Center, UT Health San Antonio

Abstract Preview: Purpose:
Quantifying and visualizing uncertainty is critical for building clinical trust in AI-generated dose distributions. This study evaluates Monte Carlo Dropout (MCD), Snapshot Ensemble (SE), ...

Evaluating Variability in Luminance Measurements Among Calibrated Light Meters for Mammography Review Workstation Surveys

Authors: Weiyuan Wang

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose:
This study investigates the variability between popular light meters by measuring mammography review workstation monitors using three calibrated light meters.
Methods:
Three calibrat...

Evaluation of MR Proton Density Fat Fraction (PDFF) for Bone Marrow Protection in RT

Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang

Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital

Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

FMEA for Direct to Unit Adaptive Radiotherapy

Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert

Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis

Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...

Feasibility of Commercial Independent-Dose-Calculation for Pencil-Beam-Scanning Proton Therapy

Authors: Wen C. Hsi, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...

Feasibility of Real-Time Monitoring in Tumor Treating Fields Therapy Using Electrical Impedance Tomography: Analysis of Current Injection and Measurement Patterns

Authors: Sung Hwan Ahn, Yongha Gi, Jinju Heo, Jinyoung Hong, Yunhui Jo, Yousun KO, Hyeongjin Lim, Sang Yoon PARK, Myonggeun Yoon

Affiliation: Institute of Global Health Technology (IGHT), Korea University, Republic of Korea, Korea University, Samsung Medical Center

Abstract Preview: Purpose:
This study aims to evaluate the feasibility of real-time monitoring of conductivity changes induced by thermal variations during tumor treating fields (TTFields) therapy using Electrical I...

Iguard: A Fully Unsupervised Image-Guidance Anomaly Recognition and Detection Framework in CBCT-Guided Radiotherapy.

Authors: James M. Lamb, Dishane Chand Luximon, Jack Neylon, Rachel Petragallo, Moritz Ritter, Timothy Ritter

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, ETH Zurich, VCU Health System, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: Anomalies in cone beam computed tomography (CBCT) radiotherapy image guidance can signal treatment deviations. Repetitive review of setup image registrations by humans is inefficient, prone t...

Investigation into the Robustness of Spine Stereotactic Body Radiotherapy Plans to Patient Setup Errors

Authors: Yukio Fujita, Syoma Ide, Fumiki Ito, Kei Ito, Satoshi Kito, Keiko Murofushi, Yujiro Nakajima, Yuhi Suda, Kentaro Taguchi, Naoki Tohyama, Fumiya Tsurumaki, Riku Watanabe

Affiliation: Komazawa University Graduate School, Komazawa University, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital

Abstract Preview: Purpose: Spine stereotactic body radiotherapy (SBRT) demands high precision due to the target's proximity to the spinal cord and steep dose gradients, which complicate treatment planning. Consequently...

Investigations on Intensity-Modulated Proton Therapy Robust-Optimization Strategies and Their Dosimetric Effects on Head and Neck Cancers

Authors: Shen Fu, Zhangmin LI, Zuofeng LI, Yuanshui Zheng

Affiliation: GuangZhou Concord Cancer Center, Guangzhou Concord Cancer Center

Abstract Preview: Purpose: To investigate the influence of different robustness optimization strategies and parameters in proton therapy plans for head and neck tumors on target coverage and OAR (organ at risk) sparing...

Is Your Resident Ready to Become a Brachytherapy Physicist? a Training Exercise and Evaluation Tool in HDR Brachytherapy Planning Errors

Authors: Amar K. Basavatia, Lee C. Goddard, Wolfgang A. Tomé, Christian Velten, Ping Yan, Ravindra Yaparpalvi, Maria Stefania diMayorca

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: High dose rate (HDR) brachytherapy planning is a high-risk procedure performed under significant time pressure, with human failure being the leading cause of error. To elevate training for me...

Latent Diffusion Model-Driven Semi-Supervised Semantic Segmentation of Cell Nuclei

Authors: Mark Anastasio, Hua Li, Zhuchen Shao

Affiliation: Washington University School of Medicine, University of Illinois Urbana-Champaign

Abstract Preview: Purpose: Automated semantic segmentation of cell nuclei in microscopic images is vital for disease diagnosis and tissue microenvironment analysis. However, obtaining large annotated datasets for train...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Performance Evaluation of Patient Demographics Model-Based Liver Volumetry

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash, Ali Yousefi

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Patient-demographics-model-based liver volumetry is well-established for determining the future liver remnant following hepatectomy. We used gold-standard CT liver segmentation to validate th...

Quantifying Uncertainties in Radiation Risk and Performance-Based Clinical Risk Assessment in Clinical Computed Tomography

Authors: Em Harkness, Francesco Ria, Ehsan Samei

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose:
A recently introduced mathematical method quantifies performance-based clinical risk to create a risk-to-risk assessment with radiation risk, rendering the so-called total risk. However, t...

Quantitative Image Review Metric for Vertebral Body Misalignment

Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)

Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...

Role of Medical Physicists in CT Contrast Optimization: A Case Study

Authors: Zahra Alyani Nezhad, Carrie Bartels, Rachel Bladorn, Sean D. Rose, Kelsey Schluter, Timothy P. Szczykutowicz

Affiliation: Departments of Radiology and Medical Physics, University Wisconsin-Madison, University of Wisconsin Madison, University of Wisconsin-Madison, University of Texas at Houston Medical School, University of Wisonsin-Madison

Abstract Preview: Purpose: This study presents a scientifically quantified case study that underscores the importance of the medical physicist’s contribution to contrast enhancement optimization.
Methods: CT pulmona...

Serial PET-CT Activity Concentration during Small Target Lung Tumor SBRT

Authors: Joseph Barbiere, Joseph Hanley, Brett Lewis, Jay Mistry, Alois M. Ndlovu, Roland Teboh

Affiliation: Hackensack University Medical Center, HUMC, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Quantitative PET-CT can evaluate clinical response to radiotherapy. For tumors less than approximately 3cm partial volume effects due to the poor PET resolution makes accurate measurement ...