Search Submissions 🔎

Results for "evaluation stereotactic": 31 found

4π Non-Coplanar Stereotactic Body Radiation Therapy: Dosimetric Evaluation of VMAT Configurations in for Recurrent Head and Neck Tumors

Authors: Sixue Dong, Weigang Hu, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the dosimetric benefits and treatment efficiency of different beam configurations in 4π non-coplanar VMAT for SBRT in recurrent head and neck tumors

Method...

A Quantitative Analysis of Interplay Effects in IMPT for Lung Cancer SBRT: Comparing Two Machine Delivery Sequence Models

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...

A Real-Time Framework for Fiducial Tracking and Intrafraction Motion Assessment of Cyberknife in Stereotactic Body Radiation Therapy for Liver Cancer

Authors: Ruiyan Du, Mingzhu Li, Ying Li, Wei Liu, Shihuan Qin, Yiming Ren, Biao Tu, Hui Xu, Lian Zhang, Xiao Zhang, Zengren Zhao

Affiliation: Department of General Surgery, Hebei Key Laboratory of Colorectal Cancer Precision Diagnosis and Treatment, The First Hospital of Hebei Medical University, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Mayo Clinic, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Fiducial tracking is widely used in CyberKnife to dynamically guide the gantry for moving target like liver cancer stereotactic body radiation therapy (SBRT). This study developed a robust fr...

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Assessing the Impact of Intrafraction Shifts on Critical OAR Doses in a Standardized Spine SBRT Program

Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann

Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania

Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...

Auto-Contouring of OAR Enhances Patient Safety and Workflow in Gamma Knife Stereotactic Radiosurgery

Authors: Sven Ferguson, S. Murty Goddu, Ana Heermann, Taeho Kim, Nels C. Knutson, Hugh HC Lee, Shanti Marasini, Timothy Mitchell, Seungjong Oh, Kevin Renick

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis

Abstract Preview: Purpose: In the Gamma Knife stereotactic radiosurgery (GK-SRS), the delineation of organs-at-risks (OARs) was not fully automated. Due to the cumbersome nature of manual OAR contouring, dose evaluatio...

Biologically Guided Deep Learning for MRI-Based Brain Metastasis Outcome Prediction after Stereotactic Radiosurgery

Authors: Evan Calabrese, Hangjie Ji, Kyle J. Lafata, Casey Y. Lee, Eugene Vaios, Chunhao Wang, Lana Wang, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke Kunshan University, North Carolina State University

Abstract Preview: Purpose: To develop a biologically guided deep learning (DL) model for predicting brain metastasis(BM) local control outcomes following stereotactic radiosurgery (SRS). By integrating pre-SRS MR image...

Clinical Feasibility of a Deep-Learning-Based Auto Contouring through Qualitative and Dosimetric Assessments

Authors: Sara Endo, Takeshi Fujisawa, Hidehiro Hojo, Masaki Nakamura, Hidenobu Tachibana

Affiliation: Department of Radiation Oncology, National Cancer Center Hospital East, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: To assess the clinical feasibility of deep learning (DL)-based automated contouring through qualitative and quantitative assessments.

Methods: Sixty cases were chosen, including 3 OARs...

Designing Impactful Radiotherapy Training for Skill Development and Long-Term Growth

Authors: Stephanie Bennett, Sean L. Berry, Caroline M. Colbert, Dustin J. Jacqmin, James A. Kavanaugh, Minsun Kim, Maura L. Kirk, Emily Kruse, Benjamin Li, Mu-Han Lin, Lindsey A. Olsen, Jose Carlos Pichardo, Justin R. Roper, Leah K. Schubert, Chunhao Wang, Sua Yoo

Affiliation: University of Wisconsin, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Abington - Jefferson Health, Mayo Clinic, University of Washington, University of Colorado Health, University of Colorado Denver, Department of Radiation Oncology, University of Washington and Fred Hutch Cancer Center, Duke University, Pichardo Physics LLC, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: As clinics in lower- and middle-income countries (LMICs) transition to advanced radiotherapy techniques like IMRT and VMAT, gaps in training can result in suboptimal planning. To help support...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Development and Validation of a Deep Learning-Based Auto-Segmentation Module for Vestibular Schwannoma

Authors: John Byun, Steven D Chang, Cynthia Fu-Yu Chuang, Xuejun Gu, Melanie Hayden Gephart, Yusuke Hori, Fred Lam, Gordon Li, Lianli Liu, Weiguo Lu, David Park, Erqi Pollom, Elham Rahimy, Deyaaldeen Abu Reesh, Scott Soltys, Gregory Szalkowski, Lei Wang, Xianghua Ye, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Neurosurgery, Stanford University, Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Accurate and automated delineation of vestibular schwannoma (VS) volume is crucial for disease management, as both treatment approaches (stereotactic radiosurgery and invasive surgery) and mo...

Development of a Deep Learning Model for Accurate Brain Dose Prediction in Multi-Target Stereotactic Radiosurgery Plan Evaluation

Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Wenyin Shi, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Multi-target stereotactic radiosurgery (SRS) planning poses challenges due to complex geometries, small target volumes, and steep dose gradients. Achieving a balance between target coverage a...

Dosimetric Evaluation of the Aldo Function for Multiple Brain Metastases in Automated Stereotactic Radiosurgery Treatment Planning

Authors: Hsiao-Mei Fu, Shih-Ming Hsu, Chia-Ting Lee, Shih-Hua Liu, Tsung-Yu Yen

Affiliation: National Yang Ming Chiao Tung University, Mackay Memorial Hospital

Abstract Preview: Purpose: The Automatic Lower Dose Objective (ALDO) is a unique function designed to achieve 98% relative coverage across all targets in automated SRS treatment planning (HyperArc planning). This study...

Early Evaluation Study for Stereotactic Adaptive Radiotherapy for Pancreatic Cancer with Ethos 2.0 System

Authors: Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Rojano Kashani, Kyle O'Carroll, Gisele Castro Pereira, Christian Erik Petersen, Alex T. Price, Meiying Xing, Reine abou Zeidane

Affiliation: university hospital, University Hospitals Seidman Cancer Center

Abstract Preview: Purpose:
Experimental data have shown the inconsistent monitor unit and target coverage in Ethos 1.1. This can lead to inaccurate dose delivery, compromising patient safety and treatment outcomes. ...

Enhancing Synthetic Pelvic CT Images from CBCT Using Vision Transformer with Adaptive Fourier Neural Operators

Authors: Rashmi Bhaskara, Oluwaseyi Oderinde

Affiliation: Purdue University

Abstract Preview: Purpose: This study proposes a novel approach to overcoming CBCT image quality limitations by developing an improved synthetic CT (sCT) generation method based on a CycleGAN architecture using Vision ...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Evaluation of Daily Respiratory Pattern from a Single Free-Breathing Cone Beam CT Scan

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Evaluation of Treatment Delivery Efficiency and Workflow Optimization in Prostate Stereotactic Body Radiation Therapy: A Comparative Study of C-Arm and O-Ring Linear Accelerators

Authors: Yijian Cao, Jenghwa Chang, Lyu Huang

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose: This study evaluates the treatment delivery efficiency and workflow of two advanced linear accelerator systems—Varian’s TrueBeam (C-arm) and Halcyon (O-ring)—for prostate Stereotactic Body Ra...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexion™ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXion® X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Evaluation of the Extrapolated Output Factors of Varian's Halycon Beam Model for Fields Smaller Than 1 Cm with AAA and Acurosxb

Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez

Affiliation: Houston Methodist Hospital, Kaiser Permanente

Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

Novel AI-Powered Tool to Objectively Evaluate Brain Dose for Multi-Met Stereotactic Radiosurgery Optimization

Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Richard A. Popple, Wenyin Shi, Rodney J. Sullivan, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao

Affiliation: Thomas Jefferson University, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: Objectively evaluating brain sparing as a plan-quality indicator for patients receiving stereotactic radiosurgery (SRS) to multiple metastases (multi-met) is complicated by variability in tar...

Optimized Dosimetric Planning for Trigeminal Neuralgia Using Cyberknife S7 Precision TPS with Volo Optimizer

Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...

Ratoguide: Evaluation of AI-Driven Fully Automated Treatment Planning Support System for Lung SBRT

Authors: Keiichi Jingu, Noriyuki Kadoya, Takafumi Komiyama, Takeru Nakajima, Hikaru Nemoto, Hiroshi Onishi, Masahide Saito, Ryota Tozuka

Affiliation: Department of Radiology, University of Yamanashi, Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Department of Advanced Biomedical Imaging, University of Yamanashi

Abstract Preview: Purpose: We evaluated the accuracy of a new AI-based fully automated planning software in stereotactic body radiotherapy (SBRT) for early-stage lung cancer.
Methods: We collected data from 125 pati...

Retrospective Evaluation of Combined Photon SBRT and Radium-223 SPECT Based Radiopharmaceutical Therapy Tumor Dosimetry in Clinical Trial Patient Cases

Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang

Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill

Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...

Robust Evaluation of Rotational Uncertainties on Single-Isocenter Multi-Target Stereotactic Radiosurgery Hyperarc Treatment

Authors: Albert Admasu, Kayla Alfonso, Maria de la Luz De Ornelas, Nesrin Dogan, Eric Mellon, Yunze Yang

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Rotational uncertainties in single-isocenter multi-target (SIMT) stereotactic radiosurgery (SRS) HyperArc treatments can cause additional target displacement, potentially degrading overall pl...

Target Region-Specific Dose-Volume Parameters for Estimate of Brain Toxicity in Single-Isocenter Multiple-Metastases Linac-Based Stereotactic Radiosurgery

Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...

Three-Dimensional Reconstruction of Triggered Images with Dehazing Algorithm for Precise Intrafraction Motion Detection in Spine SBRT

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: To precisely detect intrafraction patient motion during spine stereotactic body radiotherapy (SBRT) treatment delivery, we propose an optimized technique for three-dimensional reconstruction ...