Authors: Thomas R. Bortfeld, Prof. Elisabetta De Bernardi, Tianxue Du, Beatrice Foglia, Chiara Gianoli, Takamitsu Masuda, Katia Parodi, Marco Pinto, Boon-Keng Kevin Teo, Yunhe Xie
Affiliation: Department Of Radiation Oncology, Massachusetts General Hospital (MGH), School of Medicine and Surgery, University of Milano-Bicocca, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, National Institutes for Quantum Science and Technology (QST), University of Pennsylvania, Department of Experimental Physics - Medical Physics, Ludwig-Maximilians-Universität (LMU) München
Abstract Preview: Purpose: The full potential offered by protons in clinical practice is limited by range uncertainties. One possibility for monitoring is through secondary prompt gammas (PG). PG emission along the pen...
Authors: Krishnendu Saha
Affiliation: Cleveland Clinic Foundation
Abstract Preview: Purpose: The goal is to improve quantitative accuracy of a Maximum-a-posteriori expectation maximization (MAPEM) reconstruction of SPECT phantom images by optimizing Gibbs prior parameters.
Methods...
Authors: Qihui Lyu, Javier Caravaca Rodriguez, Youngho Seo, Ke Sheng, Jingjie Yu
Affiliation: University of California San Francisco, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Simultaneous broad-energy imaging is critical for many theragnostic applications, but the current Single-Photon Emission Computed Tomography (SPECT) can only image low energy photons with ...