Search Submissions 🔎

Results for "factor comparisons": 28 found

A Method to Check the Consistency and Reproducibility of VMAT Delivery

Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...

A Novel Device for Radiation Therapy Machine Quality Assurance

Authors: Jonathan Dowell, Grace Francis, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Iridesce Solutions, Inc.

Abstract Preview: Purpose: A novel radiation therapy quality assurance (RT QA) device has been designed, constructed and tested. The nüFilmTM machine QA system provides a method for collecting light, mechanical and rad...

A Perturbative Approach to Determine the Charge Collection Efficiency in High Dose-per-Pulse Beams

Authors: Julien Bancheri, Jan P. Seuntjens

Affiliation: Medical Biophysics, University of Toronto, Princess Margaret Cancer Centre & University of Toronto

Abstract Preview: Purpose: To obtain an analytical expression for the charge collection efficiency of parallel-plate ionization chambers in high dose-per-pulse (DPP) beams that takes into account the square pulse time ...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Analysis of Noise Power Spectra in MR Parallel Imaging

Authors: Sulaiman D. Aldoohan, Gerardo Garcia

Affiliation: University of Toledo Medical Center

Abstract Preview: Purpose: To evaluate the noise power spectra (NPS) of images acquired using parallel imaging with varying acceleration factors in 1-D and 3-D spaces and to compare the level of the power of the noise ...

Assessment of Image Quality and Dose in Dual-Energy X-Ray Imaging for Lung Tumor Tracking

Authors: Nawal Alqethami, Felix Ginzinger, Prasannakumar Palaniappan, Marco Riboldi, Philipp Steininger, Wentao Xie

Affiliation: Research & Development, medPhoton GmbH, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose:
This study evaluates the image quality of Dual-Energy (DE) X-ray imaging for lung tumor tracking across various sizes and protocols, comparing its imaging dose to Single-Energy (SE) imagin...

Commissioning, Validation and Pilot Study of New Rpld System for Dosimetry Audits in Bulgaria

Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov

Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital

Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...

Comparison of Computed Tomography Scanner Protocols Using an in-House Automated Method across Machines at a Single Institution

Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda

Affiliation: Yale University School of Medicine, Yale University

Abstract Preview: Purpose: To evaluate acquisition parameters of computed tomography (CT) scanner protocols across different machines to provide patients and clinicians consistent care and image quality, respectively.<...

Comparison of Image Quality and Radiation Dose Among Four Vendors of Mobile Digital Radiography Systems

Authors: Nathalie Correa, Janet Ching-Mei Feng, Chun-Han Huang, Jimmy Huynh

Affiliation: UTHealth McGovern Medical School

Abstract Preview: Purpose: To compare the image quality and the dose-area product (DAP) of four mobile digital radiography (DR) systems—Canon (Soltus 500), Shimadzu (MobileDaRt Evolution MX8), Solution for Tomorrow (M1...

Determine Noise Weighting Factor in Photon-Counting CT Via Deep Learning for Personalized Noise Reduction

Authors: Xinhui Duan, Roderick W. McColl, Mi-Ae Park, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: UT Southwestern Medical Center, Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Image-based deep-learning noise-reduction techniques have been developed for photon-counting CT (PCCT) to improve image quality with reduced radiation dose. The denoising strength is typic...

Dosimetric Uncertainties Associated with Photon Small Field Dosimetry

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...

Evaluating Three Practical Approaches to Managing Dose Accumulation in Normal Tissues during Radiation Re-Treatments

Authors: Derek A. Fiedler, Nixon Gutierrez, Quyen L. Jones, Zejian Liu, Tatsiana Reynolds

Affiliation: Texas Oncology, Minnesota Oncology, US Oncology

Abstract Preview: Purpose: Optimize patient safety and treatment efficacy during radiation re-treatment planning. Provide a comprehensive comparison of the methods by focusing on their applicability, accuracy, and limi...

Evaluation of the Extrapolated Output Factors of Varian's Halycon Beam Model for Fields Smaller Than 1 Cm with AAA and Acurosxb

Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez

Affiliation: Houston Methodist Hospital, Kaiser Permanente

Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...

Fractionation of Electron RT Reduces the Flash Effect in Murine Skin

Authors: Xu Cao, Wesley S. Culberson, Aleksandra Ilina, Kendall Jarvis, Brian W Pogue, Matthew Reed, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison, UW-Madison

Abstract Preview: Purpose: While FLASH radiotherapy is known to reduce skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR). Currently it is not clear whether this ...

Implementing TG-191 for Robust Calibration of Scintillation Imaging As a Clinical dosimetry Tool

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Scintillation imaging has demonstrated unique advantages to existing clinical in vivo dosimetry (IVD) techniques by enabling full-field visualization, direct comparison to the treatment plan,...

Influence of Treatment Site on Lung Shunt Fraction Estimation in 90y-Radioembolization Planning: Comparison of Planar and SPECT Imaging-Based Quantification

Authors: Lukas M. Carter, Jazmin Schwartz

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Accurate lung shunt fraction (LSF) estimation is essential for the safety and efficacy of 90Y-radioembolization therapy. This study compares planar gamma camera imaging and tomographic SPECT-...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...

Lesion Detection in Contrast Enhanced Cone Beam Breast CT with a Photon Counting Detector: A Monte Carlo Study

Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: Contrast-enhanced breast cone-beam computed tomography (bCBCT) provides high-resolution, 3D imaging of breast tissues with improved differentiation between normal and abnormal tissues. Curren...

Lu-177 Recovery Coefficients Using Tc-99m Surrogate Method: Intra- & Inter-Scanner Comparison

Authors: Ben Piacitelli, Celeste Winters

Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...

Mid-Range Planning for Efficient and Robust Proton Arc Therapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...

New Insights into Automatic Treatment Planning for Cancer Radiotherapy Using Explainable Artificial Intelligence.

Authors: Md Mainul Abrar, Yujie Chi

Affiliation: University of Texas at Arlington, Department of Physics, University of Texas at Arlington

Abstract Preview: Purpose: Healthcare 5.0, proposed in 2021, includes interpretable healthcare analysis as a core component. Achieving this requires the application of explainable artificial intelligence (XAI) to overc...

Parameterized Dosimetric Models of the Lumbar Vertebrae for Patient-Informed Active Marrow Dosimetry in Radiopharmaceutical Therapy

Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Michael Lassmann, Maikol Salas-Ramirez, Bangho Shin, Johannes Tran-Gia, Yitian Wang

Affiliation: Department of Nuclear Medicine, University Hospital Würzburg, University of Florida

Abstract Preview: Purpose: Conduct a parameterized library of mesh-type skeletal models across the lumbar vertebrae. In radiopharmaceutical dosimetry, the hematopoietic active bone marrow is typically a dose-limiting n...

Recovery Factor Comparisons for Reirradiation Overlapping the Spinal Cord

Authors: Xinxin Deng, Issam M. El Naqa, Jimm Grimm, Lijun Ma, Vitali Moiseenko, Timothy E. Schultheiss, Gopal Subedi, Wolfgang A. Tomé, Ellen D. Yorke, Albert van der Kogel

Affiliation: Montefiore Medical Center, Wellstar Kennestone Hospital Cancer Center, H. Lee Moffitt Cancer Center, Department of Human Oncology, University of Wisconsin–Madison, Department of Radiation Oncology, Wellstar Health System, Radiation Oncology, Keck School of Medicine of USC, Georgia Institute of Technology, University of California San Diego, City Of Hope National Medical Centre, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Reirradiation is increasingly utilized in clinical practice but dose-time recovery factors for human subjects remain uncertain. We constructed a reirradiation recovery model for spinal cord e...

Retrospective Comparison of Treatment Plan Quality As a Function of Delivery Time for SBRT Thoracic Tumors

Authors: Danielle Renee Daiger, Nicholas N. Sperling

Affiliation: University of Toledo, University of Toledo Medical Center

Abstract Preview: Purpose:
To retrospectively evaluate the impact of planned delivery time on plan quality metrics for breath-hold VMAT SBRT thoracic cancer patients.
Methods:
Patients treated for SBRT thoraci...

The Dosimetric and Dose RATE Characteristics for Bragg Peak Proton MINI-Ridge Filter Flash in Comparison to Conventional Proton and Filter Free Flash for Breast and Prostate

Authors: Jenghwa Chang, Chingyun Cheng, J Isabelle Choi, Muhammad Hamza, Minglei Kang, Tyler Kaulfers, Grant Lattery, Haibo Lin, Charles B. Simone, Xingyi Zhao

Affiliation: Peking University, Hofstra University Medical Physics Program, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Physics and Astronomy, Hofstra University, Physics Resident at Montefiore Einstein, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: In terms of high dose rate FLASH, the question remains on how to properly deliver treatment and what clinical sites are feasible to deliver such treatment. The novel Bragg peak (BP-FLASH) and...

Two's Company, Three's a Crowd? a Bayesian Approach to Optimizing the Number of Measurement Readings in Radiation Therapy QA

Authors: Siyong Kim, Ava Paek, Joseph B. Schulz, James J. Sohn, Eric D. Stolen, Ethan D. Stolen

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Virginia Commonwealth University, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: The American Association of Physicists in Medicine Task Group 142 (AAPM TG-142) guidelines recommend three measurements during monthly quality assurance to keep results within two standard de...

Validation of Radiopharmaceutical Therapy (RPT) Dose Calculation Platforms from Absolute Absorbed Dose Measurement of 225ac

Authors: Bryan Bednarz, Larry A. DeWerd, Sean Jollota, Ahtesham Ullah Khan, Ohyun Kwon, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: The accurate quantification of absorbed dose is essential for alpha-emitting radionuclides used in radiopharmaceutical therapy (RPT). This study presents the first direct comparison of physic...