Search Submissions ๐Ÿ”Ž

Results for "failure modes": 32 found

4DCT Vs 5DCT: How to Generate an Accurate Target Volume

Authors: Ryan Andosca, Rojine T. Ariani, Peter Boyle, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, Los Angeles, UCLA Radiation Oncology

Abstract Preview: Purpose: To demonstrate that 5DCT can provide an accurate internal tumor volume (ITV) while 4DCT cannot.
Methods: The 5DCT imaging protocol uses a motion model and 25 deformably registered free-bre...

A Risk Assessment Approach to Photon Reference Dosimetry Using TG-100 Methodology

Authors: Ila Farhang, Ryan D. Foster, Devin Heitz, Jordan B Lunsford, Ashkan Shafiee

Affiliation: Atrium Health Wake Forest Baptist, Atrium Health/LCI Cabarrus

Abstract Preview: Purpose: American Association of Physicists in Medicine (AAPM) Task Group (TG) -51 is a widely utilized protocol for the absolute calibration of linear accelerators. The purpose of this project was fo...

AI-Driven Early Detection of Digital Radiography Performance Degradation: A Predictive Quality Control Approach

Authors: Giovanni Iacca, Gloria Miori, Laura Orsingher, Daniele Ravanelli, Annalisa Trianni

Affiliation: Department of Information Engineering and Computer Science, University of Trento, Medical Physics Department, S.Chiara Hospital, APSS

Abstract Preview: Purpose: This study aims to leverage artificial intelligence (AI) to predict and identify performance degradation in Digital Radiography (DR) systems, enabling proactive maintenance and minimizing cli...

An Automated System for MRI Coil Performance Evaluation

Authors: Michael Cuddy, Samuel J. Fahrenholtz, Khushnood Hamdani, Saman Jirjes, Robert G. Paden, Jeremiah W. Sanders, William F. Sensakovic, Wolfgang Stefan, Jeffrey Xiao, Yuxiang Zhou

Affiliation: Mayo, Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Title: An automated system for MRI coil performance evaluation

Purpose: To develop an automated quality control (QC) system for MRI coils to assess element-level signal-to-noise ratio (SNR), ar...

An FMEA-Based Approach to Improve the Process and Quality Control on MR Imaging from Outside Diagnostic Imaging Centers to be Used for Radiation Treatment Planning

Authors: Olivier Blasi, Eric Cameron, Brad K. Lofton

Affiliation: CAMP, Colorado Assn in Medical Phys (CAMP)

Abstract Preview: Purpose:
Magnetic Resonance (MR) imaging obtained from external centers for radiation therapy (RT) planning can suffer from suboptimal protocols and geometric distortions. These issues can require ...

Biologically Guided Deep Learning for MRI-Based Brain Metastasis Outcome Prediction after Stereotactic Radiosurgery

Authors: Evan Calabrese, Hangjie Ji, Kyle J. Lafata, Casey Y. Lee, Eugene Vaios, Chunhao Wang, Lana Wang, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke Kunshan University, North Carolina State University

Abstract Preview: Purpose: To develop a biologically guided deep learning (DL) model for predicting brain metastasis(BM) local control outcomes following stereotactic radiosurgery (SRS). By integrating pre-SRS MR image...

CNN-Based Visualization for Detecting Failure Patterns of Lung SBRT through CT-Biological Effective Dose Interaction

Authors: Ashok Bhandari, Kurtis Johnson, Yu Lei, Tianzhe Li, Kyuhak Oh, Shuo Wang, Chi Zhang, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: The purpose of this study was to leverage neural network visualization tools to detect high-attention areas indicative of treatment failure in lung SBRT by examining correlation matrices betw...

Comprehensive Assessment of a Large Field of View Phantom for Routine MR Image Quality on a 1.5T Mrgrt System

Authors: Krystal M. Kirby, Aliasghar Rohani, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center, Louisiana State University, Baton Rouge, Louisiana

Abstract Preview: Purpose: Accurate treatment delivery in MR-guided radiotherapy (MRgRT) systems requires consistent imaging quality assurance (QA) to assess MR image quality. However, standard QA phantoms have limited...

Development and Evaluation of Aria Report-Based Initial Chart Check Tool

Authors: Ulrich Langner, Timothy Leech, Oleksii Semeniuk

Affiliation: Brown University Health

Abstract Preview: Purpose: To standardize and improve quality of the chart review process, while simultaneously increasing the efficiency of the physicist, by allowing them to allocate more time for other items.
Met...

Development and Validation of a Scalable Radiomics Pipeline for Lung Cancer Research Using Clinical and Public Datasets

Authors: Pradeep Bhetwal, Yingxuan Chen, Wookjin Choi, Michael Dichmann, Adam Dicker, Rupesh Ghimire, Yevgeniy Vinogradskiy, Maria Werner-Wasik

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Radiomics has emerged as a powerful tool in medical research. However, the lack of standardized and reproducible pipelines limits its clinical adoption. This study developed a robust and scal...

Development of a Method to Standardize Multi-Institutional Quality Assurance Data through an AI Based Language Model Ontology.

Authors: Rafe A. McBeth, Ayoola Okuribido, Rodney D. Wiersma

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA

Abstract Preview: Purpose: To develop a method for standardizing data collected during quality assurance checks across institutions using language models.
Background: QA procedures and data management can vary widel...

Development of a Method to Standardize Multi-Instiutional Quality Assurance Data through an AI Based Language Model Ontology.

Authors: Rafe A. McBeth, Ayoola Okuribido, Rodney D. Wiersma

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA

Abstract Preview: Purpose: To develop a method for standardizing data collected during quality assurance checks across institutions using language models.
Background: QA procedures and data management can vary widel...

Dosimetric Uncertainties Associated with Photon Small Field Dosimetry

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...

Enhanced Prediction of Iroc Stereotactic Radiosurgery Phantom Audit Results with Treatment Parameters, Complexity Metrics, DVH, and Dosiomics Using Machine Learning

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Christine Peterson, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop predictive models for IROC SRS head phantom audits and to identify important factors influencing institutional performance.
Methods: The IROC SRS head phantom includes two TLDs ...

Evaluating the Performance and Limitations of an Automated Treatment Planning Tool for Intact Breast Radiotherapy across Diverse Patient Populations

Authors: Shatha Al Afifi, Hana Baroudi, Leonard Che Fru, Laurence Edward Court, Suzanne B. Evans, Kent A. Gifford, Adam D. Melancon, Melissa P. Mitchell, Issa Mohamad, Patricia Murina, Manickam Muruganandham, Tucker J. Netherton, Callistus M. Nguyen, Joshua S. Niedzielski, Deborah L. Schofield, Simona Shaitelman, Willie Shaw, Sanjay S. Shete, Adam Shulman, Brendon Smith, Sheeba Thengumpallil, Carlos Daniel Venencia, Conny Vrieling

Affiliation: University of Cape Town, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, University of the Free State, UT MD Anderson Cancer Center, King Hussein Cancer Center, Instituto Zunino - Fundacion Marie Curie, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Dra., Hirslanden Clinique des Grangettes, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Therapeutic Radiology, Yale University School of Medicine, Yale University, The University of Texas, MD Anderson, Houston TX

Abstract Preview: Purpose:
Automated contouring and planning tools are usually trained on single-institution datasets, seldom tested across diverse patient populations. This introduces a risk of population bias, res...

FMEA for Direct to Unit Adaptive Radiotherapy

Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert

Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis

Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

Failure Mode and Effects Analysis (FMEA) on Use of Surface Guided Imaging

Authors: Victoria Noelle Bry, Tamara Egan, Eric C. Ford, Angelia Landers, Juergen Meyer

Affiliation: Fred Hutch Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) can improve patient safety, however, its complex integration may expose processes to increased risk of error. This work identifies potential failures f...

Feasibility of Commercial Independent-Dose-Calculation for Pencil-Beam-Scanning Proton Therapy

Authors: Wen C. Hsi, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...

Improving 4D-MRI Parameters for Abdominal Tumor Motion Management: A Phantom Study

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: For soft-tissue abdominal tumors, a 4D-MR may provide improved tumor tracking over the clinical standard 4D-CT. This project aims to optimize a clinically available 4D-MR pulse sequence to ac...

In-Silico Clinical Trials Enabled By Digital Twin Approach Can Accurately and Prospectively Predict Outcomes of Clinical Trials Combining Radiation and Systemic Therapy

Authors: Clemens Grassberger, David (Bo) McClatchy, Harald Paganetti

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Massachusetts General Hospital

Abstract Preview: Purpose: While randomized controlled trials (RCTs) are the gold standard for demonstrating efficacy, nearly 50% of late-stage clinical trials fail to meet their endpoint. Tools to study the design of ...

Inter-Machine Harmonization in Echocardiographic Videos for Predicting Left Ventricular Ejection Fraction

Authors: Akihiro Haga, Ren Iwasaki, Kenya Kusunose, Makoto Miyake, Kenji Moriuchi, Yasuharu Takeda, Hidekazu Tanaka, Hirotsugu Yamada

Affiliation: Department of Cardiovascular Medicine, Nephrology, and Neurology Graduate School of Medicine, University of the Ryukyus, Graduate School of Biomedical Sciences, Tokushima University, Tokushima university, Division of Cardiovascular Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Department of Cardiology, Tenri Hospital, Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Division of Heart Failure, Department of Heart Failure and Transplant, National Cerebral and Cardiovascular Center

Abstract Preview: Purpose: Device dependency is a significant challenge in medical AI, potentially limiting generalization performance. This study aimed to develop a robust deep learning model for predicting left ventr...

Investigating Factors Impacting the Consistency of Signal-to-Noise Ratio in Mammographic Automatic Exposure Control

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the impact of tissue-equivalent attenuator materials, the region of interest (ROI) size, and the orientation of the attenuator positioning on the measured signal-to-no...

Lymph Node Malignancy Prediction in Head and Neck Cancer Using a Graph Neural Network

Authors: Liyuan Chen, Meixu Chen, Bowen Jing, Sepeadeh Radpour, Erich Josef Schmitz, David Sher, Jing Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Prospective clinical trials have shown that involved nodal radiation therapy (INRT) can substantially improve patientsโ€™ quality of life without increasing the risk of elective nodal failure. ...

Optimizing Fractionation Schedules for De-Escalation Radiotherapy in Head and Neck Cancers Using Deep Reinforcement Learning

Authors: Zhongjie Lu

Affiliation: Department of Radiation Oncology, The First Affiliated Hospital, Zhejiang University School of Medicine

Abstract Preview: Purpose: Patients with locally-advanced head and neck squamous cell carcinomas(HNSCCs), particularly those related to human papillomavirus(HPV), often achieve good locoregional control(LRC), yet they ...

PET Imaging and Novel Cardiac Radiomics to Predict Pre-Radiotherapy Cardiac Conditions for Lung Cancer Patients Undergoing Radiotherapy.

Authors: Wookjin Choi, Michael Dichmann, Adam Dicker, Nilanjan Haldar, Yingcui Jia, Nicole L Simone, Eugene Storozynsky, Yevgeniy Vinogradskiy, Maria Werner-Wasik

Affiliation: Thomas Jefferson University, 9Department of Radiation Oncology, Thomas Jefferson University

Abstract Preview: Purpose: Cardiotoxicity remains a significant limitation for lung cancer patients treated with radiotherapy. Pre-radiotherapy cardiac conditions increase the probability of patients developing cardiot...

Photon-Proton Treatment Compatible Couch Tops Render Modality-Dependent Support Structure Models

Authors: Estelle Batin, Michael A. Carlson, Nilendu Gupta, Zachary X. Richards, Diana Shvydka

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center

Abstract Preview: Purpose: With an increase in world-wide proton treatment availability, patients sometimes are transferred between proton and photon modalities. Among the main reasons for modality shifts are proton be...

Predicting Proton Therapy Dose Delivery Accuracy: A Machine Learning Approach Using Irocโ€™s Proton Phantom Data

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop a machine learning model for predicting dose delivery accuracy and identifying its key factors in IROCโ€™s proton phantom program.
Methods: IROCโ€™s proton QA program has six proton...

Prospective Hazard Analysis in Radiation Therapy โ€“ a Systematic Review

Authors: Jeremy T. Booth, Sonja Dieterich, Jonathan Hindmarsh, Paul J. Keall

Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, UC Davis Medical Center, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: Prospective hazard analysis (PHA) is a core medical physics function. PHA was investigated by AAPM Task Group 100 for the purpose of keeping patients safe and assessing the risks of novel tec...

Refined Nnu-Net Training for Practice-Specific Autosegmentation of APBI Targets

Authors: Daniel A. Alexander, Jonathan Baron, Brook Kennedy Byrd, William Ross Green, Bolin Li, Rafe A. McBeth, Abigail Pepin, Steven Philbrook

Affiliation: Department of Radiation Oncology and Applied Sciences, Department of Radiation Oncology, University of Pennsylvania, Thayer School of Engineering, University of Pennsylvania

Abstract Preview: Purpose: As accelerated partial breast irradiation (APBI) gains traction, the prospect of a rapid sim-to-completion of treatment workflow is an attractive option for patients. While OAR autocontouring...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

Using Open-Source Reasoning Large Language Models for Radiotherapy Structure Name Harmonization

Authors: Claus Belka, Stefanie Corradini, Christopher Kurz, Guillaume Landry, Matteo Maspero, Adrian Thummerer, Erik van der Bijl

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Radboud University Medical Center, UMC Utrecht

Abstract Preview: Purpose: To automatically harmonize non-standardized organ-at-risk (OAR) structure names from multi-lingual, multi-institutional radiotherapy datasets using state-of-the-art open-source reasoning larg...