Search Submissions ๐Ÿ”Ž

Results for "fiducial markers": 20 found

A Real-Time 6 Degrees-of-Freedom Image Guided Radiation Therapy Technology Using Internal-External Motion Correlation Modelling

Authors: Jeremy T. Booth, Nicholas Hardcastle, Freeman Jin, Alicja Kaczynska, Paul J. Keall, Chandrima Sengupta

Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, Physical Sciences, Peter MacCallum Cancer Centre, Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: An ESTRO survey reported that 71% of radiotherapy centers across 41 countries want to implement real-time image guided radiation therapy (IGRT) to improve patient outcomes. To address this gl...

A Real-Time Framework for Fiducial Tracking and Intrafraction Motion Assessment of Cyberknife in Stereotactic Body Radiation Therapy for Liver Cancer

Authors: Ruiyan Du, Mingzhu Li, Ying Li, Wei Liu, Shihuan Qin, Yiming Ren, Biao Tu, Hui Xu, Lian Zhang, Xiao Zhang, Zengren Zhao

Affiliation: Department of General Surgery, Hebei Key Laboratory of Colorectal Cancer Precision Diagnosis and Treatment, The First Hospital of Hebei Medical University, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Mayo Clinic, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Fiducial tracking is widely used in CyberKnife to dynamically guide the gantry for moving target like liver cancer stereotactic body radiation therapy (SBRT). This study developed a robust fr...

Application of Surface-Based Approaches and Implanted Fiducial Markers to Enable Gated Treatment of Mobile Tumors Using SBRT

Authors: Victoria Noelle Bry

Affiliation: University of Washington

Abstract Preview: N/A...

Comparison Study of Shift Frequency and Magnitude By Prostate Fiducial Tracking System: Triggered Image and Calypso

Authors: David J. Carlson, Yiu-Hsin Chang, Zhe (Jay) Chen, Hyosung Cho, Dae Yup Han, MinYoung Lee, Weili Zhong

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose:
To compare the intra-fractional motion tracking sensitivity of prostate fiducial markers using triggered imaging and calypso tracking for prostate cancer cases.
Methods:
This study w...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varianโ€™s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Dual-Domain Reconstruction Network for Nonstop Gated CBCT Imaging: Application in Respiratory Gating Ablative Radiotherapy for Pancreatic Cancer

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yabo Fu, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Boris Mueller, Huiqiao Xie, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gating ablative radiotherapy for pancreatic cancer accounts for tumor movement due to respiration and typically requires 5, 15, or 25 fractions. Pretreatment imaging verification is essential...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Estimation of Brain Tumorโ€™s Intra-Fraction Movement during Radiosurgery Using Fiducial Markers on the Skin Surface โ€“ a Simulation Study

Authors: Damien C. Mathew, Brandon Hai Nguyen, Satwik Pani, Yoichi Watanabe

Affiliation: Minnespolis Radiation Oncology, Department of Radiation Oncology, University of Minnesota Medical School, Washington University

Abstract Preview: Purpose: To formulate a computational algorithm to quantify the tumor movement from the motion data of landmarks on the brain surface. To estimate the magnitude of tumor movement when the head makes a...

Evaluating the Adequacy of Planning Target Volume Margins in Lung Stereotactic Body Radiation Therapy: Assessment of Intrafraction Motion Using a Fiducial Marker

Authors: Rashmi Benda, Qinghao Chen, Shifeng Chen, Giovanni Lasio, Peter Olivieri, Huijun Xu, Junliang Xu, Byong Yong Yi, Baoshe Zhang, Jinghao Zhou

Affiliation: University of Maryland Baltimore Washington Medical Group, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center

Abstract Preview: Purpose:
We investigated if the patients receiving lung stereotactic body radiation therapy (SBRT) have adequate planning target volume (PTV) margins by evaluating the intrafraction motion using a ...

Evaluating the Readiness for Ultra-Hypofractionated Prostate and Breast Radiotherapy in Sub-Saharan Africa: A Strategic Needs-Assessment of Six Leading African Institutions

Authors: Samuel O. Adeneye, Victoria Susan Ainsworth, Azeezat Ajose, Stephen M. Avery, Munir Awol, Kavuma Awusi, Onyinye Balogun, Rohini Bhatia, Frank Chinegwundoh, Jumaa Dachi Kisukari, Curtiland Deville, Katy Graef, Yao Hao, M. Saiful Huq, Luca Incrocci, Adedayo O. Joseph, Solomon Kibudde, Joerg Lehmann, Heng Li, Abba Mallum, Thokozani Mkhize, Twalib Ngoma, Wilfred Ngwa, Christopher F. Njeh, Janine Simons, William Swanson, Maureen Bilinga Tendwa, Joseph Weygand, Krishni Wijesooriya

Affiliation: Uganda Cancer Institute, Johns Hopkins University, BIO Ventures for Global Health, Weill Cornell Medicine, Washington University School of Medicine, South Africa Health Product Regulatory Authority, University of Pennsylvania, University of Massachusetts Lowell, NSIA-LUTH Cancer Center, University of Lagos, Indiana University School of Medicine, Department of Radiation Oncology, Erasmus Medical Center, Department of Radiation Oncology and Applied Science, Dartmouth Health, Addis Ababa University, Ocean Road Cancer Institute, Emory University, Barts Health NHS Trust, Inkosi Albert Luthuli Central Hospital, Lagos University Teaching Hospital, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, University of Virginia School of Medicine, University of Newcastle

Abstract Preview: Purpose: Sub-Saharan Africa continues to face a critical shortage in radiotherapy resources, exacerbating the regionโ€™s growing cancer burden. One potential strategy that can partially offset this prob...

Feasibility of Markerless Dynamic Tumor Tracking-VMAT Using Diaphragm Detection and Respiratory Phase-Based Offset Vector

Authors: Noriko Kishi, Takashi Mizowaki, Mitsuhiro Nakamura, Yukine Shimizu

Affiliation: Kyoto University, Kyoto Univercity, Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To predict tumor positions in markerless dynamic tumor tracking (ML-DTT)-VMAT by compensating for the asynchrony between the tumor and the diaphragm.
Methods: Rotational fluoroscopic X-ray...

Fully Automated Review of Prostate Radiotherapy Treatment Plan Quality

Authors: Yasin Abdulkadir, John Charters, Melissa Ghafarian, James M. Lamb, Dishane Chand Luximon, Jack Neylon

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose:
Assessment of radiotherapy treatment quality in large-scale multi-institutional contexts remains an outstanding challenge. Retrospective human review of treatment plans is labor intensive ...

Impact of Breathing Trace on Gating Uncertainty

Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.

Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...

Investigation of Triggered Imaging and Auto Beam Hold Using a Dynamic Thorax Phantom for Intra-Fraction Motion Management

Authors: Liu Hong, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...

Modified Dehazenet for Scatter Correction in Triggered Imaging: Enhancing Visibility and Alignment Precision for Radiation Therapy

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...

Patient-Specific Orthogonal Projection Based Real-Time Volumetric X-Ray Imaging for Proton Therapy

Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...

Reproducibility of Target Position during Surface-Guided Breath-Hold Adaptive SBRT of Liver Cancer

Authors: Lili Chen, Xiaoming Chen, Chang Ming Charlie Ma, Joshua Meyer

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Fast CBCT (HyperSight) acquisition technique together with a surface-guided breath-hold (SGBH) would allow a better image quality for accurate target/organ delineation. It facilitates breath-...

Three-Dimensional Reconstruction of Triggered Images with Dehazing Algorithm for Precise Intrafraction Motion Detection in Spine SBRT

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: To precisely detect intrafraction patient motion during spine stereotactic body radiotherapy (SBRT) treatment delivery, we propose an optimized technique for three-dimensional reconstruction ...

Use of Radiopaque Rectal Spacer for IGRT โ€“ a Preliminary Analysis of Alignment Accuracy and Interobserver Variability

Authors: Joseph A. Miccio, Nicholas J. Potter, Zain Siddiqui

Affiliation: Penn State Health Milton S. Hershey Medical Center

Abstract Preview: Purpose: Fiducial markers are the gold standard for prostate alignment during CT-based image-guided radiotherapy (IGRT). Radiopaque hydrogel rectal spacers reduce rectal toxicity by displacing the rec...

Using the Liver Dome for Real-Time Respiratory Motion Adaptive Tracking in Cyberknife Stereotactic Body Radiotherapy (SBRT) for Lung Tumors

Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...