3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

A Comparative Study of Hypersight and Truebeam Cone Beam Computed Tomography Image Quality

Authors: Sorour Hosseini, YuHuei Jessica Huang, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To evaluate image quality—including noise, contrast-to-noise ratio (CNR), uniformity, and low-contrast visibility (LCV)—on the HyperSight and TrueBeam cone-beam computed tomography (CBCT) pla...

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...

A Quantitative Analysis of Hypersight CBCT Image Quality Using a Phantom-Based Approach Under Different Scatter Conditions

Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...

Comparison of Image Quality and Radiation Dose Among Four Vendors of Mobile Digital Radiography Systems

Authors: Nathalie Correa, Janet Ching-Mei Feng, Chun-Han Huang, Jimmy Huynh

Affiliation: UTHealth McGovern Medical School

Abstract Preview: Purpose: To compare the image quality and the dose-area product (DAP) of four mobile digital radiography (DR) systems—Canon (Soltus 500), Shimadzu (MobileDaRt Evolution MX8), Solution for Tomorrow (M1...

Comprehensive Assessment of a Large Field of View Phantom for Routine MR Image Quality on a 1.5T Mrgrt System

Authors: Krystal M. Kirby, Aliasghar Rohani, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center, Louisiana State University, Baton Rouge, Louisiana

Abstract Preview: Purpose: Accurate treatment delivery in MR-guided radiotherapy (MRgRT) systems requires consistent imaging quality assurance (QA) to assess MR image quality. However, standard QA phantoms have limited...

Comprehensive Evaluation of High-Performance Cone-Beam Computed Tomography on C-Arm and Ring-Gantry Linacs for Adaptive Radiation Therapy

Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...

Conformal Flash for Large Treatment Fields

Authors: Julien Forthomme, Carolina Llina Fuentes, Valentin Hamaide, Lucian Hotoiu, Rudi Labarbe, Rasmus Nilsson, Arnaud Pin, Francois Vander Stappen, Erik Traneus

Affiliation: RaySearch Laboratories AB, Ion Beam Applications SA

Abstract Preview: Purpose: Conformal FLASH achieves ultra-high-dose-rate (UHDR) proton therapy (>40 Gy/sec) by scanning a mono-energetic pencil beam through accessories (range shifter, Conformal Energy Modulator, apert...

Design and Testing of a Portable Microwave Scanner for Imaging Soft Tissue and Tumors in Cancer Patients

Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed

Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...

Design of a Small Animal Proton Flash Irradiation System with High Achievable Dose and Dose Rate Using a Synchrotron Proton Beamline

Authors: Zongsheng Hu, Yuting Li, Radhe Mohan, Emil Schueler, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: In previous work, we developed an irradiation system for pre-clinical ultra-high-dose-rate(FLASH) radiotherapy experiments based on synchrotron proton beamline. However, the beam current limi...

Dose Rate Measurements of Scanning Carbon Ion Beams Using a Plastic Scintillator Detector

Authors: Motohiro Kawashima, Adrian Kugara, Masao Nakao, Shuichi Ozawa, Mutsumi Tashiro, Maria Varnava

Affiliation: Gunma University Heavy Ion Medical Center, Hiroshima High-Precision Radiotherapy Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the time-dependent dose rate characteristics of a scanning carbon ion beam using a fast-response plastic scintillator detector (PSD), with a focus on its potentia...

Dosimetric Characteristics of a Commercially Available Platinum Cured Silicone Rubber Material As a Custom Bolus Option

Authors: Jordan B Lunsford, Sagar Pokhrel, Ashkan Shafiee, Curtis S. Whiddon

Affiliation: Atrium Health Wake Forest Baptist, University of North Carolina, Atrium Health Wake Forest Baptist High Point Medical Center

Abstract Preview: Purpose: To investigate the dosimetric characteristics of a platinum cured silicone rubber material (Platsil) for use as custom bolus in radiotherapy
Methods: Sheets of 2, 4, 6, and 8 mm Platsil we...

Evaluating the Impact of Beam Spot Spacing on Dose Rates and Field Uniformity for Small Animal Proton Ultra-High Dose Rate Irradiation

Authors: Jack Biondo, Audrey Magness, Anthony E. Mascia, Zhiyan Xiao, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center

Abstract Preview: Purpose: Proton FLASH-RT has shown promise reducing normal tissue toxicity while maintaining tumor control. However, in vivo experiments critically depend on achieving ultra-high dose rate (UHDR) and ...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

Impact of Beamline Mis-Adjustment Following Central Beamline Replacement for Halcyon Linear Accelerator

Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma

Affiliation: University of California San Francisco, University of California, San Francisco, University of California

Abstract Preview: Purpose: Introduced in 2018, the Varian Halcyon platform has increased in popularity due to its reduced cost, user-friendly design, and operational efficiency. As this platform ages, major repairs, in...

Novel Design for a Mechanically Tunable Ceramic Volume Resonator for 9.4T Pre-Clinical MRI

Authors: Victor B. Kassey, Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert

Affiliation: Dartmouth College

Abstract Preview: Purpose: High-resolution magnetic field uniformity is essential for quantitative and pre-clinical MRI research. Imaging uniformity is affected by the B0 field, which can be corrected using manual or a...

QA Your Way: A Customizable 3D Printed CT Simulator Monthly QA Phantom

Authors: Paul J. Black, Jordan B Lunsford, James D. Ververs, India Wood

Affiliation: Atrium Health Wake Forest Baptist, Wake Forest University School of Medicine, Wake Forest School of Medicine

Abstract Preview: Purpose:
To develop a 3D-printed modular CT simulator phantom that allows the assessment of all AAPM TG-66 recommended monthly quality assurance (QA) tests.
Methods:
A modular CT simulator mo...

Rapid 3D Prototyped Solid-Source Phantoms for Quality Assurance of Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...

Relative Optimized Linearization for Film Dosimetry with Non-Uniformity Correction

Authors: Piotr Pater, Nicholas G. Zacharopoulos

Affiliation: McGill University, Medical Physics Unit, Gerald Bronfman Department of Oncology, McGill University

Abstract Preview: Purpose: To develop a method for accurate relative film dosimetry that incorporates non-uniformity
corrections.
Methods: The accuracy of Devic’s [1] linearization approach was evaluated using si...

Simulation Design of a Dedicated Head Coil for Enhanced EPT Imaging to Map the Electrical Properties of Tumor Tissues

Authors: Jingyao Chen, Yingli Yang, Jie Zhang

Affiliation: Department of Radiology, Ruijin Hospital, Shanghai Ruijin Hospital, Shanghai United imaging Healthcare Advanced Technology Research Institute

Abstract Preview: Purpose: Magnetic Resonance Electrical Properties Tomography (MR EPT) is a method to spatially mapping the conductivity and permittivity based on small B1 field changes after the imaged object was int...

Simultaneous Motion Estimation and Image Reconstruction with Spatiotemporal Implicit Neural Representation Initial (STINR-SMEIR) for Gas Bubble Motion Artifact Reduction in on-Board CBCT Imaging

Authors: Hua-Chieh Shao, Shanshan Tang, Jing Wang, Kai Wang, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: Artifacts caused by gas bubble movement in the gastrointestinal tract can severely degrade the image quality of on-board abdominal cone-beam computed tomography (CBCT), impacting its utility ...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...