A Customizable Phantom Insert Design for Testing Deformable Image Registration with Simulated Respiratory Motion

Authors: Mubasheer Chombakkadath, Tara E. Tyson, Iris Z. Wang

Affiliation: Roswell Park Comprehensive Cancer Center, University at Buffalo (SUNY)

Abstract Preview: Purpose: Deformable image registration (DIR) is critical in adaptive radiation therapy (ART). Existing DIR phantoms either simulate tumor shape or volume changes but lack comprehensive motion simulati...

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...

AI-Assisted 3D Microscale Mesh Models of Human Lungs from Iodine-Stained Serial-Sectioned Histology Images and Their Dosimetry Applications

Authors: John P. Aris, Wesley E. Bolch, Robert Joseph Dawson, Bonnie N. C. President, Yitian Wang

Affiliation: Johns Hopkins University, University of Florida

Abstract Preview: Purpose: Generation of a mesh-based microscale lung model is essential for accurate dosimetry analysis. Lungs exchange air with the environment and may be exposed to alpha-particle-emitting radionucli...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

An Efficient, Low-Cost, and Accessible Film Dosimetry Scanning System

Authors: Parminder S. Basran, Wyatt Flanders, Skylar Sylvester

Affiliation: Cornell University

Abstract Preview: Purpose: To develop a reliable, efficient, and low-cost methodology for quantifying radiation doses using radiochromic film and a custom-built lightbox and to evaluate the system's performance compare...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterizing and Modeling Higher-Order Motions of Collimator Subsystem on a 60RPM Gantry Linac for Improved Small Target Dosimetry

Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...

Commissioning of Elekta Leipzig and Valencia Skin Applicators

Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao

Affiliation: The George Washington University, The George Washington University Cancer Center

Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Correction Factors for Estimating Skin Dose from Overresponse of Two Commercial Optically Stimulated Luminescence Dosimeters

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Dosimetry Calibration for Low-Energy Protons (2-4 MeV) Using Gafchromic Film Dosimeters

Authors: Michael Dingfelder, Homeira Faridnejad

Affiliation: East Carolina University, Department of Physics, East Carolina University

Abstract Preview: Purpose: To use Gafchromic film for measurement of the dose delivered by low-energy (2-4 MeV) protons to living cells.
Methods: Five different types of Gafchromic films were tested for dosimetry un...

Dosimetry Commissioning of a Commercial Cabinet X-Ray Irradiator for Small Animal Irradiation

Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center

Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...

Dosimetry Comparison of Surface-Guided and Orthogonal X-Ray Film-Based Setups for Proton Pencil-Beam Scanning in Breast Cancer Treatment

Authors: Darren Kaplan, Chenguang Liu, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center

Abstract Preview: Purpose: This study evaluates the hypothesis that surface-guided radiation therapy for the breast or chest wall using proton PBS provides comparable target coverage and OARs sparing to x-ray-based IGR...

Dosimetry for Low Energy Electrons and Their Potential Use in Radiotherapy

Authors: Christoph Bert, Leon Brückner, Luitpold Distel, Julian Freier, Peter Hommelhoff, Bastian Löhrl

Affiliation: Department of Radiation Oncology, Uniklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Department Physik, Friedrich-Alexander Universität Erlangen-Nürnberg

Abstract Preview: Purpose: Low energy electron (LEE) bunches in the kilo electronvolt (keV) range are thought to have a high relative biological effectiveness (RBE). To investigate this, it is necessary to establish re...

EBT4 Film Dosimetry and the Significance of the ¼ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Evaluation of Film and 3D Printed Patient-Specific Phantom for Minibeam Radiation Therapy (MBRT) Dosimetry

Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus

Affiliation: Mayo Clinic - Rochester, Mayo Clinic

Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Innovative Workflow for Enhanced in-Vivo Dosimetry Using Gafchromic Film

Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...

Investigating the Flash Effect: Uncovering Brain Sparing and Cognitive Preservation across Varying Dose Rates in Whole-Brain Irradiation of in-Vivo Mouse Models

Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu

Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Log File-Based Patient-Specific QA As a Viable Alternative to Measurement-Based QA in IMPT

Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider

Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

On the Development and Commissioning of an in-Vivo Dosimetry Program Using Small Pieces of Gafchromic Film

Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Phase One Randomized Two-Arm Dose Escalation of Flash RT in Veterinary Canine Osteosarcoma: Trial Design & Initial Results

Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Radio-Acoustic Monitoring of Electron Flash Therapy In Vivo

Authors: Kristina Bjegovic, Luke Connell, Emil Schueler, Leshan Sun, Lucy Whitmore, Liangzhong Xiang

Affiliation: University of California, Irvine, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The use of FLASH-RT in the clinic would greatly reduce off-target radiation toxicity in normal tissues. However, due to the hypo-fractionated delivery of prescribed doses at FLASH dose rates,...

Radiological Assessment of Radiochromic Film Models EBT3 and EBT4 in Proton Beams

Authors: Kuan Ling Chen, Jiajin Fan, Rao Khan, Robabeh Rahimi

Affiliation: University of Maryland, Inova Schar Cancer Institute, Howard University

Abstract Preview: Purpose: This study evaluates the dose response, energy dependency, sensitivity, reproducibility, temporal response, and LET dependency along and in the plane perpendicular to a clinical proton beam f...

Rapid 3D Prototyped Solid-Source Phantoms for Quality Assurance of Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...

Relative Optimized Linearization for Film Dosimetry with Non-Uniformity Correction

Authors: Piotr Pater, Nicholas G. Zacharopoulos

Affiliation: McGill University, Medical Physics Unit, Gerald Bronfman Department of Oncology, McGill University

Abstract Preview: Purpose: To develop a method for accurate relative film dosimetry that incorporates non-uniformity
corrections.
Methods: The accuracy of Devic’s [1] linearization approach was evaluated using si...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

The Topas Monte Carlo Framework – Status and Outlook after 15 Years of Development

Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Thongchai Masilela, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin

Affiliation: University of California San Francisco, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital

Abstract Preview: Purpose: To present the results of 15 years of developments of the TOPAS TOol for PArticle Simulation framework, and to highlight recent and new developments.

Methods: Fundamental understanding...

Towards Clinical Translation: Optical Methods Deliver in-Vivo per-Pulse Dosimetry in Electron Flash-RT

Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...