3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Assessing Dose Enhancement and Shadowing Effects in Head and Neck Cases with Titanium Mandibular Implants

Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...

Automated Quantitative Method for Source Position Calculation in Annual Quality Assurance of High Dose Rate Brachytherapy Gynecological Applicators

Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Clinical Implementation of a Film Based Psqa System for SBRT on a 1.5T MR-Linac

Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal

Affiliation: Sunnybrook Health Sciences Centre

Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...

Combining Proton Flash and Spatially Fractionated Radiotherapy – Experimental and Simulation Based Dosimetric Characterization

Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore

Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Correction Factors for Estimating Skin Dose from Overresponse of Two Commercial Optically Stimulated Luminescence Dosimeters

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...

Creation of Pass-through Proton Minibeams Using a Single Quadrupole Magnet

Authors: Abdullah A. Alshreef, Grant A. McAuley, Jerry D Slater

Affiliation: Loma Linda University Medical Center, Loma Linda University

Abstract Preview: Purpose: In this project we investigate the use of a single permanent magnet quadrupole to create pass-through proton minibeams suitable for potential clinical use and preclinical radiobiology experim...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Design, Optimization, and Preclinical Validation of a Novel Applicator Integrating Real-Time Dose Monitoring for Ultra-High Dose Rate (FLASH) Electron Radiotherapy

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose: To develop, optimize and validate a novel applicator for ultra-high dose rate (UHDR) electron radiotherapy incorporating an electrostatically shielded beam current transformer (BCT) for real-...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...

Dosimetry Commissioning of a Commercial Cabinet X-Ray Irradiator for Small Animal Irradiation

Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center

Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...

Dosimetry for Low Energy Electrons and Their Potential Use in Radiotherapy

Authors: Christoph Bert, Leon Brückner, Luitpold Distel, Julian Freier, Peter Hommelhoff, Bastian Löhrl

Affiliation: Department of Radiation Oncology, Uniklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Department Physik, Friedrich-Alexander Universität Erlangen-Nürnberg

Abstract Preview: Purpose: Low energy electron (LEE) bunches in the kilo electronvolt (keV) range are thought to have a high relative biological effectiveness (RBE). To investigate this, it is necessary to establish re...

EBT4 Film Dosimetry and the Significance of the ¼ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Evaluating Stent-Induced Dose Perturbations in Intravascular Brachytherapy with EBT4 Films

Authors: Yijian Cao, Jenghwa Chang, Nicholas Coupey, Lyu Huang, Jessica Jung

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
The Synergy bioabsorbable polymer (BP) stent, made of Platinum Chromium Alloy, is widely utilized in treating coronary artery disease. This study investigates dose perturbations caused by ...

Evaluation of Film and 3D Printed Patient-Specific Phantom for Minibeam Radiation Therapy (MBRT) Dosimetry

Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus

Affiliation: Mayo Clinic - Rochester, Mayo Clinic

Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

First Beam Characterization of the Radiabeam FLEX-9 Electron Flash Linac

Authors: Robert Berry, John Buatti, Nathan Burger, Ryan T. Flynn, Greg Johns, Maksim Kravchenko, Sergey Kutsaev, Yen-Po Lee, Marcos Ruelas, Joel J. St-Aubin, Timothy J. Waldron

Affiliation: RadiaBeam Technologies, University of Iowa

Abstract Preview: Purpose: To report the factory acceptance tests of a preclinical linear accelerator, the FLEX-9 electron FLASH linac from RadiaBeam Technologies.
Methods: The FLEX-9 FLASH electron linac is designe...

Impact of Breathing Trace on Gating Uncertainty

Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.

Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Investigating the Flash Effect: Uncovering Brain Sparing and Cognitive Preservation across Varying Dose Rates in Whole-Brain Irradiation of in-Vivo Mouse Models

Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu

Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...

Minimizing Abscopal Effects in Normal Tissues with Flash-RT: Mechanisms of Action and Potential Clinical Applications

Authors: Liang Cui, Xingyu Lu, Hang Shang, LingHong Zhou

Affiliation: Southern Medical University

Abstract Preview: Purpose: This study examines how varying dose rates of radiotherapy impact normal tissues outside the target area and analyzes the protective effects and regulatory mechanisms of ultra-high dose rate ...

On the Development and Commissioning of an in-Vivo Dosimetry Program Using Small Pieces of Gafchromic Film

Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...

Phantom Assessment for Treating Large Tumors with Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy uses positron emissions from FDG-avid tumor volumes to provide a of the planned prescribed dose with high accuracy. The purpose of this work is to characterize BgR...

Phase One Randomized Two-Arm Dose Escalation of Flash RT in Veterinary Canine Osteosarcoma: Trial Design & Initial Results

Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Quantitative Analysis of Long-Term Optical Density Variations of Irradiated and Un-Irradiated EBT3 Films

Authors: Rick Holly, Sumudu Katugampola

Affiliation: Gesinger Medical Center, Geisinger Medical Center

Abstract Preview: Purpose:
To quantitatively analyze long term variations in optical density of un-irradiated and irradiated EBT3 radio-chromic films and their effects on dose calibration curves in a clinical settin...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Radiological Assessment of Radiochromic Film Models EBT3 and EBT4 in Proton Beams

Authors: Kuan Ling Chen, Jiajin Fan, Rao Khan, Robabeh Rahimi

Affiliation: University of Maryland, Inova Schar Cancer Institute, Howard University

Abstract Preview: Purpose: This study evaluates the dose response, energy dependency, sensitivity, reproducibility, temporal response, and LET dependency along and in the plane perpendicular to a clinical proton beam f...

Rapid 3D Prototyped Solid-Source Phantoms for Quality Assurance of Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...

Relative Optimized Linearization for Film Dosimetry with Non-Uniformity Correction

Authors: Piotr Pater, Nicholas G. Zacharopoulos

Affiliation: McGill University, Medical Physics Unit, Gerald Bronfman Department of Oncology, McGill University

Abstract Preview: Purpose: To develop a method for accurate relative film dosimetry that incorporates non-uniformity
corrections.
Methods: The accuracy of Devic’s [1] linearization approach was evaluated using si...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...