Search Submissions 🔎

Results for "film measurements": 72 found

3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

A Novel 2D Scintillation Dosimeter Using Long Scintillating Fibers.

Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval

Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...

A Novel Approach to Preclinical Intensity-Modulated Radiotherapy Using an Open-Source Ring-Based Compensator Device and Inverse Treatment Planning System

Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo

Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cmÂČ), which can reduce beam fluence by up to 93% compared to the unmodified ...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

An Efficient, Low-Cost, and Accessible Film Dosimetry Scanning System

Authors: Parminder S. Basran, Wyatt Flanders, Skylar Sylvester

Affiliation: Cornell University

Abstract Preview: Purpose: To develop a reliable, efficient, and low-cost methodology for quantifying radiation doses using radiochromic film and a custom-built lightbox and to evaluate the system's performance compare...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Application and Analysis of Advanced 3D Printed Materials As Bolus for Radiation Therapy

Authors: Rami M. Shorti, Gary R. Stinnett

Affiliation: Intermountain Health, Radiation Oncology, Intermountain Health, Advanced Visualization Engineering Department

Abstract Preview: Purpose: In this work we present the workflow, materials analysis, and lessons learned from leveraging advanced 3D printing Polyjet Technology to print conformal bolus for radiation therapy.
Method...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Assessing Dose Enhancement and Shadowing Effects in Head and Neck Cases with Titanium Mandibular Implants

Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

Assessment of Plan Quality Metrics for Iroc Houston SRS Phantom Performance Evaluation

Authors: Derek Matthew Garcia, Mallory Glenn, Stephen F. Kry, Ruitao Lin, Dennis S. Mackin, Tucker J. Netherton

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, University of Texas’ MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Houston

Abstract Preview: Purpose: This study aims to investigate the feasibility of implementing clinically relevant quality metrics for evaluating IROC SRS phantom plans, including conformity index (CI) and homogeneity index...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische WerkstÀtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterizing and Modeling Higher-Order Motions of Collimator Subsystem on a 60RPM Gantry Linac for Improved Small Target Dosimetry

Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...

Clinical Implementation of a Film Based Psqa System for SBRT on a 1.5T MR-Linac

Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal

Affiliation: Sunnybrook Health Sciences Centre

Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...

Combining Proton Flash and Spatially Fractionated Radiotherapy – Experimental and Simulation Based Dosimetric Characterization

Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore

Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...

Commissioning Silicone Tissue-Compensating Bolus for Electron Beam Therapy

Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura

Affiliation: University of Massachusetts Chan Medical School

Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning of Elekta Leipzig and Valencia Skin Applicators

Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao

Affiliation: The George Washington University, The George Washington University Cancer Center

Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Correction Factors for Estimating Skin Dose from Overresponse of Two Commercial Optically Stimulated Luminescence Dosimeters

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...

Cross Characterization of a 3D Gamma Camera and Ring Brachytherapy Applicator

Authors: Zachary R. Grelewicz, Kevin C. Jones, Yixiang Liao, Andrew Ogilvy, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To demonstrate the accuracy and QA application of a time-resolved 3D gamma camera, we measured the path traversed by the Ir-192 High-Dose-Rate (HDR) brachytherapy source passing through a rin...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Development of the First Benchtop X-Ray Flash System

Authors: Ruirui Dong, Gernot Echner, Peter Haering, Clarence King, Carlos Murillo, Gavin Poludniowski, Nicholas Sammut, Joao Seco, Steffen Seeber, Maria Francesca Spadea, Elpida Theodoridou

Affiliation: KIT, Department of Physics and Astronomy, Heidelberg University, Karolinska Institutet, DKFZ, University of Malta

Abstract Preview: Purpose:
The goal is to develop the first benchtop X-ray FLASH system based on a conventional small animal irradiator. The small animal irradiator will be modeled using a Monte Carlo toolkit for bo...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Dosimetry Calibration for Low-Energy Protons (2-4 MeV) Using Gafchromic Film Dosimeters

Authors: Michael Dingfelder, Homeira Faridnejad

Affiliation: East Carolina University, Department of Physics, East Carolina University

Abstract Preview: Purpose: To use Gafchromic film for measurement of the dose delivered by low-energy (2-4 MeV) protons to living cells.
Methods: Five different types of Gafchromic films were tested for dosimetry un...

Dosimetry Commissioning of a Commercial Cabinet X-Ray Irradiator for Small Animal Irradiation

Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center

Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...

Dosimetry for Low Energy Electrons and Their Potential Use in Radiotherapy

Authors: Christoph Bert, Leon BrĂŒckner, Luitpold Distel, Julian Freier, Peter Hommelhoff, Bastian Löhrl

Affiliation: Department of Radiation Oncology, Uniklinikum Erlangen, Friedrich-Alexander-UniversitĂ€t Erlangen-NĂŒrnberg, Department Physik, Friedrich-Alexander UniversitĂ€t Erlangen-NĂŒrnberg

Abstract Preview: Purpose: Low energy electron (LEE) bunches in the kilo electronvolt (keV) range are thought to have a high relative biological effectiveness (RBE). To investigate this, it is necessary to establish re...

EBT4 Film Dosimetry and the Significance of the Œ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Enhanced Surface Dose Accuracy in Proton Treatment Planning: Optimizing External Volume HU Thresholding.

Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez

Affiliation: University of Miami

Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Evaluation of Concomitant Imaging Dose in 4D-CBCT Guided Thoracic Radiotherapy

Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao

Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...

Evaluation of Film and 3D Printed Patient-Specific Phantom for Minibeam Radiation Therapy (MBRT) Dosimetry

Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus

Affiliation: Mayo Clinic - Rochester, Mayo Clinic

Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

Film-Based Method for Accurate Radiation Isocenter Determination in Linear Accelerators Using 3D Starshot

Authors: Robert A. Corns, Mohammad Kanber

Affiliation: East Carolina University, East Carolina University Brody School of Medicine

Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...

First Beam Characterization of the Radiabeam FLEX-9 Electron Flash Linac

Authors: Robert Berry, John Buatti, Nathan Burger, Ryan T. Flynn, Greg Johns, Maksim Kravchenko, Sergey Kutsaev, Yen-Po Lee, Marcos Ruelas, Joel J. St-Aubin, Timothy J. Waldron

Affiliation: RadiaBeam Technologies, University of Iowa

Abstract Preview: Purpose: To report the factory acceptance tests of a preclinical linear accelerator, the FLEX-9 electron FLASH linac from RadiaBeam Technologies.
Methods: The FLEX-9 FLASH electron linac is designe...

Free-Breathing Spirometer-Gated Proton Pencil Beam Scanning Delivery Maintains Tumor Coverage with Improved Organ-at-Risk Sparing: A Motion Phantom Validation

Authors: Uriel Aura, Qing Chen, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Meng Wei Ho, Sheng Huang, Minglei Kang, Stanislav Lazarev, Nancy Y Lee, Yang Lei, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Anna Zhai, Ajay Zheng

Affiliation: DYN'R Medical System, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Tianjin Medical University Cancer Institute&Hospital, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Managing tumor motion during pencil beam scanning proton therapy remains challenging. This study investigated the feasibility and dosimetric benefits of Free-Breathing Respiratory-Gated Deliv...

Getting in Focus: Review of Current Focal Spot Size Testing Methods with Flat Panel Digital Radiography Detectors

Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda

Affiliation: Yale University School of Medicine, Yale University

Abstract Preview: Purpose:
Historically film has been the gold standard receptor for measurements of x-ray tube focal spot size. Flat Panel Digital Radiography Detectors (FPDRDs) have lower spatial resolution compar...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

Impact of Breathing Trace on Gating Uncertainty

Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.

Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Innovative Workflow for Enhanced in-Vivo Dosimetry Using Gafchromic Film

Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Log File-Based Patient-Specific QA As a Viable Alternative to Measurement-Based QA in IMPT

Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider

Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...

Modeling of Novel Converging Beam Radiotherapy System in Geant4 Montel Carlo Simulation

Authors: Dirk A Bartkoski, Leonard Che Fru, Benjamin Abraham Insley, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour, Aviad Schori, Ramesh C. Tailor

Affiliation: Empyrean Medical Systems, The University of Texas MD Anderson Cancer Center, Convergent-RnR, The University of Texas, MD Anderson, Houston TX

Abstract Preview: Purpose: A Geant4-based model was created for a G4BraggReflection process to simulate radiation transport within a novel radiotherapy system developed by Convergent Radiotherapy and Radiosurgery (CRnR...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

On Dosimetric Water Equivalency of 3D Printed Materials

Authors: Emily Helen Hayes, Luke Maloney

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the dosimetric water equivalency of polylactic acid (PLA) and commercial 3D printing resin using electron stopping power as a surrogate, for use in radiochromic film calibration ...

On the Development and Commissioning of an in-Vivo Dosimetry Program Using Small Pieces of Gafchromic Film

Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...

Optimized Methodology for Accurate Half-Value Layer Measurement in Preclinical X-Ray Cabinet Systems

Authors: Paolo Pellicioli, Mohammad Rezaee, Ehsan Tajikmansoury, John W. Wong

Affiliation: Institute of Anatomy, University of Bern, Baltzerstrasse, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose: Half-value layer (HVL) is a critical parameter for commissioning and quality assurance of preclinical x-ray irradiators. However, measuring HVL in cabinet systems presents challenges due to s...

Plastic Scintillating Detector Assisted Spot Mapping for Patient Specific Quality Assurance in Proton Beam Therapy

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...

Positional Accuracy and Clinical Recommendations for HDR Brachytherapy Ring Applicators: A Commissioning and Evaluation Study

Authors: Peter G. Maxim, Michael P. Reilly, Mengying Shi, Maryam Shirmohammad, Darren M. Zuro

Affiliation: University of California Irvine

Abstract Preview: Purpose: This study aims to assess the positional accuracy of HDR brachytherapy ring applicators, quantify the extent of positional deviation, and provide clinical recommendations for GYN HDR brachyth...

Proton Minibeam Radiotherapy: Commissioning, Treatment Planning, and Delivery

Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung

Affiliation: Mayo Clinic - Rochester

Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Rapid 3D Prototyped Solid-Source Phantoms for Quality Assurance of Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...

Reduction of the Charge Build-up Effect on the Beam Current Transformers for Real-Time Monitoring of Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Beam current transformers (BCTs) are a promising alternative to ion chambers for real-time monitoring of ultra-high dose per-pulse (UHDPP) beams. The signal of the BCT is insensitive to ion r...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

Synthetic Spheres: Ultrasound Image Quality Assessment with a Uniform Phantom

Authors: Ted Lynch

Affiliation: Sun Nuclear, a Mirion Medical Company

Abstract Preview: Purpose: A novel ultrasound quality assurance method is presented that constructs “synthetic spheres” at arbitrary locations within the image frame by combining correlation length measurements from a ...

Towards Arbitrary Phantom Patient Specific IMRT QA on Reflexion X1

Authors: Andrew Groll, Ayan Mitra, PhD, Manoj Narayanan, Sanchit Sharma, Ray Yang, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: To develop a versatile QA tool enabling dose recalculation of a patient’s plan sinogram redeployed onto arbitrary replacement phantom geometry, and extract computed dose along detector planes...

Treatment Planning System for Uhdr Mobetron: Refinement and Validation of Phase Space Data Input

Authors: Rafael Carballeira, Tianyuan Dai, David J. Gladstone, Philip Von Voigts-Rhetz, Rongxiao Zhang

Affiliation: Shandong Cancer Hospital, Dartmouth College, IntraOp, Thayer School of Engineering, Dartmouth College, University of Missouri

Abstract Preview: Purpose: To analyze phase space (PHSP) data generated for Mobetron in FLASH radiotherapy and assess key dosimetric characteristics, including the energy spectrum, scattering angle distribution, and pe...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...