Search Submissions 🔎

Results for "flash standard": 16 found

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

Breastplan-Helper: Publicly Shared Source Scripting Toolset to Assist in 3D Breast Planning

Authors: Ryan Clark, Anthony Magliari, Luis Felipe Oliveira E Silva, Yang Sheng, Jason R Vickress, Qingrong Jackie Wu, Giulianne Rivelli Rodrigues Zaratim

Affiliation: Verspeeten Family Cancer Center, Office of Medical Affairs, Varian, A Siemens Healthineers Company, Confiar Radioterapia, Duke University Medical Center

Abstract Preview: Purpose: Develop a toolset to replace several of the tedious steps required to manually generate 3D breast treatment plans using static gantry forward planned tangent beams.

Methods: Eclipse Sc...

Calorimetric Measurement of Absorbed Dose By a Flash Beamline

Authors: Luke Connell, Stephen F. Kry, Malcolm R. McEwen, Bryan R. Muir, James Renaud, Emil Schueler, Hayden Scott, Paige A. Taylor

Affiliation: National Research Council, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To demonstrate the capability of a robust calorimeter to accurately determine the absorbed dose delivered by an electron FLASH beamline.

Methods: Electron FLASH beams of 6 MeV and 9 Me...

Conformal Flash for Large Treatment Fields

Authors: Julien Forthomme, Carolina Llina Fuentes, Valentin Hamaide, Lucian Hotoiu, Rudi Labarbe, Rasmus Nilsson, Arnaud Pin, Francois Vander Stappen, Erik Traneus

Affiliation: RaySearch Laboratories AB, Ion Beam Applications SA

Abstract Preview: Purpose: Conformal FLASH achieves ultra-high-dose-rate (UHDR) proton therapy (>40 Gy/sec) by scanning a mono-energetic pencil beam through accessories (range shifter, Conformal Energy Modulator, apert...

Deployable Twin-Calorimeter System for Absolute Dose Measurements By Clinical Physicists

Authors: Jean Dessureault, Malcolm R. McEwen, Bryan R. Muir, James Renaud

Affiliation: National Research Council

Abstract Preview: Purpose: To develop and commission a mailable calorimeter that enables clinical medical physicists to quickly and efficiently address innovative dosimetry challenges directly at the point of use.
<...

Development of a Computational Immunohistochemical Stained Tissue Analysis of Intracellular Flash Induced Radiochemical Oxygen Depletion

Authors: Najah Curtis, Michele M. Kim, Cameron Koch, Ioannis I Verginadis, Rodney D. Wiersma, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA

Abstract Preview: Purpose: FLASH has been shown to have increased normal tissue sparing compared to standard dose rate radiation and, separately, has been shown to rapidly consume oxygen intercellularly in vivo through...

Difference in Image Quality between Natively Reconstructed and PACS Reformatted CT Images

Authors: Beth Reed, Justin B. Solomon

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: The purpose of this study was to compare image quality between CT images of variable slice thickness reconstructed directly at the scanner verses reformatted at a PACS workstation.
Methods...

Dose Rate Measurements of Scanning Carbon Ion Beams Using a Plastic Scintillator Detector

Authors: Motohiro Kawashima, Adrian Kugara, Masao Nakao, Shuichi Ozawa, Mutsumi Tashiro, Maria Varnava

Affiliation: Gunma University Heavy Ion Medical Center, Hiroshima High-Precision Radiotherapy Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the time-dependent dose rate characteristics of a scanning carbon ion beam using a fast-response plastic scintillator detector (PSD), with a focus on its potentia...

Dosex As a per-Pulse Uhdr and Conventional Electrometer Compatible with Sandard Clinical Probes

Authors: Petr Bruza, David J. Gladstone, Austin Sloop, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Health

Abstract Preview: Purpose: UHDR-specific probes are becoming available on the market but often demand high costs and long order times. The reduced sensitivity of these probes often imposes challenges when measuring con...

Evaluation of Ion Chamber Performance and Suitability for Flash Proton Therapy Dosimetry

Authors: Seohyeon An, Yoonsun Chung, Seonghoon Jeong, Seongmoon Jung, Chae-Eon Kim, In Jung Kim, Sung Hun Kim, Se Byeong Lee, Sang-il Pak, Jong In Park

Affiliation: POHANG ACCELERATOR LABORATORY, Hanyang University, Korea Research Institute of Standards and Science (KRISS), Ilsan Paik Hospital, National Cancer Center, National Cancer Center Korea, Korea Research Institute of Standards and Science

Abstract Preview: Purpose: To evaluate the performance of three ion chambers—Advanced Markus (AMC), PinPoint, and Roos—under FLASH proton beam conditions and assess the response of the nozzle monitor chamber for their ...

Impact of Diacetylene Polymer Chemistry on Real-Time Radiochromic Film Dosimetry

Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink

Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University

Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Investigation of Fluorescent Probes for Real-Time ROS Detection Under Flash Radiotherapy

Authors: Yuqi Yang, Fang-Fang Yin

Affiliation: Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Reactive oxygen species (ROS) are unstable molecules which play important roles in the cellular process after Flash radiotherapy. The rapid changes in ROS levels during treatment may provide ...

Towards Clinical Translation: Optical Methods Deliver in-Vivo per-Pulse Dosimetry in Electron Flash-RT

Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...