A Comparison of Non-Adaptive Versus Online Adaptive Radiotherapy for Prostate Cancer Using FLOW-RT-- Fast, AI-Driven but Learning-Enabled, Online Adaptive Workflow for Radiotherapy

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Angela Jia, Rojano Kashani, Kyle O'Carroll, Alex T. Price, Adithya Reddy, Atefeh Rezaei, Daniel E Spratt, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To evaluate the effect of unedited AI-generated contours used for online adaptive radiotherapy (FLOW-ART) on the plan quality of prostate treatments as compared to non-adaptive (non-ART) proc...

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

A New Way to Assess Dynamic Response of Centrally Located Lung Cancer (CLLC) to SBRT and Conventional Radiation Therapy (CRT)

Authors: Nina Burbure, Tawfik Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital, Dept. of Radiation Oncology, Fox Chase Cancer Center at Temple University Hospital

Abstract Preview: Purpose: Higher rates of local failures and toxicities challenged radiation therapy of centrally located lung cancer (CLLC). We assessed the treatment response by measuring the early changes of PET+ n...

A Quantitative Analysis of Hypersight CBCT Image Quality Using a Phantom-Based Approach Under Different Scatter Conditions

Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...

Advancing the Evaluation of Radiation-Induced Vaginal Toxicity Using Ultrasound Radiomics: Phantom Validation and Pilot Clinical Study

Authors: Himanshu Joshi, Tian Liu, Deborah C Marshall, Joseph Shelton, Jing Wang, Xiaofeng Yang, Emi Yoshida, Boran Zhou

Affiliation: Department of Radiation Oncology, Baylor College of Medicine, Icahn School of Medicine at Mount Sinai, Emory University, Department of Population Health Science and Policy, Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, University of California, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Radiation-induced long-term toxicities, such as vaginal stenosis, significantly impact the quality of life for patients undergoing pelvic radiotherapy (RT) for gynecologic (GYN) malignancies....

An Adaptive Radiotherapy Strategy Study Based on Segmented Synthesis and Deformational Registration

Authors: Jie Hu, Zhengdong Jiang, Nan Li, Tie Lv, Yuqing Xia, Shouping Xu, Gaolong Zhang, Wei Zhao, Changyou Zhong

Affiliation: School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Radiotherapy Department of Meizhou People’s Hospital (Huangtang Hospital), UT Health San Antonio, National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, Peopleʼs Republic of China, Department of Radiation Oncology

Abstract Preview: Purpose: Patients usually undergo cone-beam computed tomography (CBCT) scans which are used for patient set-up before radiotherapy. However, the low image quality of CBCT hinders its use in adaptive r...

An Efficient Deep Learning Model with Multi-Scale Integration for Automated Pancreas Segmentation on MR Images

Authors: Jingyun Chen, Yading Yuan

Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology

Abstract Preview: Purpose: To develop and evaluate the Scale-attention network (SANet) for automated pancreas segmentation on MR images.
Methods: To develop SANet, we extended the classic U-Net design with a dynamic...

Assessing Skin Microcirculation in Breast Cancer Radiotherapy: Effectiveness of a Specialized Bra Compared in Two Hypofractionated Protocols.

Authors: Rosa Maria Cibrián Ortiz de Anda, Altea C Esteve, Carlos M Galindo-González, Carmen C García, Amparo Gonzalez-Sanchis, Jose C Gordo-Partearroyo, Emilio Soria-Olivas, Javier Vijande

Affiliation: IFIC-UV, Valencia University, Hospital General Universitario

Abstract Preview: Purpose: To determine how skin microcirculation is affected by the two hypo-fractionated radiotherapy protocols in breast cancer patients using Laser Doppler Imaging, a non-invasive method for assessi...

BEST IN PHYSICS IMAGING: Cross-Contrast Diffusion: A Synergistic Approach for Simultaneous Multi-Contrast MRI Super-Resolution

Authors: Yifei Hao, Wenxuan Li, Xiang Li, Tao Peng, Yulu Wu, Fang-Fang Yin, Yue Yuan, Lei Zhang, Yaogong Zhang

Affiliation: Duke University, School of Future Science and Engineering, Soochow University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Diffusion-based deep-learning frameworks have been recently used in MRI resolution enhancement, or super-resolution. Multi-contrast MRI share common anatomical structures while holding comple...

BEST IN PHYSICS MULTI-DISCIPLINARY: Foundation Model-Empowered Unsupervised 3D Deformable Medical Image Registration

Authors: Xianjin Dai, PhD, Zhuoran Jiang, Lei Ren, Lei Xing, Zhendong Zhang

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, Stanford University, Duke University, Stanford University

Abstract Preview: Purpose: Unsupervised deep learning has shown great promise in deformable image registration (DIR). These methods update model weights to optimize image similarity without necessitating ground truth d...

BEST IN PHYSICS THERAPY: Immunomodulatory Effects of Selective PARP1 Inhibition in Combination with Photon and Alpha Particle Therapy in Immunologically Cold Breast Cancer

Authors: Scott James Bright, Vered Domankevich-Bachar, Mandira Manandhar, Poliana Marinello, Yogesh Rai, Marco Freitas Reis, Alexandre Rubinstein, Gabriel O. Sawakuchi, Ronen Segal, Walison Augusto Silva Brito, Mark Wasley, Amy Wu

Affiliation: MD Anderson Cancer Center, Alpha Tau Medical Ltd, Alpha Tau Medical LTD, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Immunologically cold breast cancers are aggressive and difficult to treat due to their lack of immune cell infiltration. The combination of high-LET radiation with DNA repair inhibitors offer...

Binary Classification of Lymphedema in 3DCRT Patients Using Machine Learning on 3D Dose Distribution Data

Authors: Jee Suk Chang, Hojin Kim, Jin Sung Kim, Jaehyun Seok

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Integrative Medicine

Abstract Preview: Purpose: This study aims to leverage 3D dose distribution data to develop a machine learning model capable of accurately predicting lymphedema occurrence in patients undergoing 3D conformal radiation ...

Breast Cancer Awareness and Education for Teens: Empowering the Next Generation to Take Charge of Their Health

Authors: Nana Akosua O. Adomako, Evangeline Dorleagbenu, Victor E. Ekpo, Fatima Issaka, Abigail N.M. Quaye

Affiliation: Tema General Hospital, Pink Africa Foundation, Korle Bu Teaching Hospital, Methodist University, Medical Equipment and Ancillary Services

Abstract Preview: Purpose: This preliminary study evaluates the effectiveness of breast cancer awareness programs for teenagers in Tema, Ghana. In Ghana, breast cancer poses a significant public health challenge. There...

CBCT-Based Synthetic CT Imaging for Proton and Photon Dose Monitoring and Adaption in Supine Breast Radiotherapy

Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang

Affiliation: UF Health Proton Therapy Institute, University of Florida

Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...

Characterisation of Breathing Volumes and Surface Motion for Upright and Supine Treatment Positions

Authors: Sophie Boisbouvier, David Cobben, Anthony L Criscuolo, Michael W. Kissick, Mark Ramtohul, Gordon Sands, Tracy Underwood

Affiliation: University of Surrey, Department of Medical Physics, Queen Elizabeth Hospital, Lung Cancer and Sarcoma Radiotherapy, The Clatterbridge Cancer Centre, Leo Cancer Care, Radiotherapy department, Centre Léon Bérard

Abstract Preview: Purpose:
Pulmonary function tests (PFTs) help assess treatment options for lung cancer patients. Conventionally, these are undertaken upright, whereas radiotherapy is administered supine. This stud...

Characterizing a VMAT Optimization Algorithm with Integrated Static-Angle Modulated Ports for Esophageal Cancer Treatment

Authors: Lei Dong, Yin Gao, Taoran Li, Michael Salerno, Boon-Keng Kevin Teo, Melissa Vila

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: A novel solution, RapidArc Dynamic-RAD (Varian Medical Systems, Palo Alto, USA) has been implemented to integrate VMAT with modulation of IMRT-like static-angle ports, including use of a dyna...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Clonogenic Assays for Three Prostate Cancer Cell Lines with Varying Levels of DNA Repair Mutations Treated with LET-Optimized Pencil Beam Scanning Protons and Evaluation of Dose Rate Effect

Authors: Mark E Artz, Jiyeon Park, Lori Rice, Mohammad Saki, Sanjeev Shukla, Michael Vieceli

Affiliation: University of Florida Health Proton Therapy Institute, Department of Radiation Oncology, University of Florida College of Medicine, UF Health Proton Therapy Institute, Department of Urology, University of Florida College of Medicine

Abstract Preview: Purpose: To investigate how varying levels of DNA repair mutations affect the LET sensitivity of prostate cancer cells.
Methods: The prostate cancer cell lines Du145 (low DNA repair mutations), PC3...

Deep Learning Aided Oropharyngeal Cancer Autoplanning

Authors: Mark Bowers, Gabriel Carrizo, Jimmy Caudell, Vladimir Feygelman, Kevin Greco, Christian Hahn, Jihye Koo, Kujtim Latifi, Fredrik Lofman, Jacopo Parvizi, Muqeem Qayyum, Caleb Sawyer

Affiliation: RaySearch Laboratories, Moffitt Cancer Center

Abstract Preview: Purpose: Head and neck (H&N) radiotherapy planning is complex, with multiple competing objectives. We endeavored to improve efficiency of planning by developing a deep learning (DL) model trained to p...

Design of Filtimator (Filter + Collimator) for CBCT of Pediatric Cancer Patients Receiving Proton Therapy

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...

Direct-to-Unit Dose Calculations for Stereotactic Radiosurgery on a C-Arm Linac with Modern on-Board Imaging Solutions

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...

Dynamic Angular Couch Kinematics in Radiotherapy

Authors: Eva Lee, R. Lee MacDonald, Alasdair Syme, Christopher G. Thomas

Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Dalhousie University, Nova Scotia Health

Abstract Preview: Purpose:
Dynamic couch rotation in radiotherapy offers dosimetric benefits, however patient comfort remains a concern. This study investigates couch kinematics in trajectory-based radiotherapy plan...

Efficient Denoising of Low-Statistic Influence Matrices Using a Diffusion Transformer-Based Framework for Adaptive Proton Therapy

Authors: Yuzhen Ding, Hongying Feng, Jason Michael Holmes, Baoxin Li, Wei Liu, Daniel Ma, Lisa McGee, Samir H. Patel, Jean Claude M. Rwigema, Sujay A. Vora

Affiliation: Arizona State University, Department of Radiation Oncology, Mayo Clinic, Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
Intensity-modulated proton therapy (IMPT) is a preferred treatment modality for head and neck (H&N) cancer patients, offering precise tumor targeting while sparing surrounding organs at ri...

Enhanced 3D Volumetric Denoising for Low-Dose CT Images Using Hformer

Authors: Edward Robert Criscuolo, Chenlu Qin, Deshan Yang, Zhendong Zhang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose:
Low-dose CT (LDCT) imaging minimizes radiation exposure but introduces significant noise, compromising image quality. While deep learning-based denoising models such as HFormer achieve sta...

Evaluating Necessity of Patient-Specific Deep Learning-Based Auto-Segmentation for Improved Adaptation for Abdominal Tumors

Authors: Asma Amjad, Renae Conlin, Eric S. Paulson, Christina M. Sarosiek

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: In an effort to improve contouring accuracy for abdominal MR guided online adaptive radiotherapy (MRgOART), patient-specific deep learning-based auto-segmentation (PS-DLAS) has been proposed....

Evaluating Normal Tissue Toxicity Following Pulsed Low Dose Rate Radiotherapy

Authors: Shahabeddin mostafanazhad Aslmarand, Lili Chen, Dusica Cvetkovic, Troy A. Dos Santos, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose:
Pulsed low-dose-rate radiotherapy (PLDR) has been proposed to reduce normal tissue toxicity while maintaining tumor control comparable to conventional radiotherapy (CRT). This study assess...

Evaluating Uncertainty Estimation Models for Clinical Integration of AI-Generated Radiotherapy Dose Distributions

Authors: Jacob S. Buatti, Kristen A. Duke, Malena Fassnacht, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia, Michelle de Oliveira

Affiliation: The University of Texas San Antonio, UT Southwestern Medical Center, UT Health San Antonio

Abstract Preview: Purpose:
Quantifying and visualizing uncertainty is critical for building clinical trust in AI-generated dose distributions. This study evaluates Monte Carlo Dropout (MCD), Snapshot Ensemble (SE), ...

Evaluating the Impact of Spot Spacing on Dosimetric Outcomes in Dynamic Arc Proton Therapy for Prostate SBRT

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Umesh Rana, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: DynamicARC is a novel pencil beam scanning (PBS) proton therapy technique with the potential to provide more conformal dose distributions and reduce treatment time. This study investigates th...

Evaluation of MR Proton Density Fat Fraction (PDFF) for Bone Marrow Protection in RT

Authors: Li Tong, Chuyan Wang, Zhengkui Wang, Yingli Yang, Jie Zhang

Affiliation: Shanghai United imaging Healthcare Advanced Technology Research Institute, Shanghai United Imaging Healthcare Co., LTD, Department of Radiology, Ruijin Hospital, Institute for Medical Imaging Technology, Ruijin Hospital

Abstract Preview: Purpose:
Pelvic radiotherapy (RT)-induced bone marrow (BM) damage affects patient prognosis by causing hematologic toxicity. However, consensus on BM-sparing (BMS) RT is still lacking, owing to the...

Evaluation of Thoracic Direct Dose Calculation Using Truebeam Linac with Hypersight Imaging CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...

Feasibility of Efficient Offline Adaptive Replanning with Hypersight High-Performance Cone-Beam CT on Truebeam for Pelvis RT

Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang

Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...

Feasibility of Rapidarc Dynamic for Lattice Radiation Therapy of Bulky Liver Tumors

Authors: Christine V. Chung, Laurence Edward Court, Meena S. Khan, Ethan B. Ludmir, Rachael M. Martin Paulpeter, Saurabh Shashikumar Nair, Callistus M. Nguyen, Joshua S. Niedzielski, Luis Augusto Perles

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Spatially Fractionated Radiation Therapy (SFRT) has re-emerged as an efficacious treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) has unique beam delivery capabilities that m...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

Improved SNR and Estimation Accuracy for Deuterium-MRI Acquired with Chemical Shift Imaging at 7 Tesla

Authors: Muhammed AR Anjum, Andrew J. Fagan

Affiliation: Mayo Clinic

Abstract Preview: Purpose:
This study describes a novel post-processing method to boost image SNR for deuterium-MRI acquired using chemical shift imaging (CSI) at 7T. Deuterium MRI via exogenous administration of a ...

Knowledge-Based Planning for Chest Wall with Lymph Nodes Irradiation VMAT

Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka

Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...

Learning from Failures – Case Studies into Failing Patient Specific Quality Assurance Plans

Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh

Affiliation: Tufts Medical Center

Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...

Long-Term Stability Assessment of an Imaging Ring System Using One Year of Monthly Quality Assurance Data

Authors: Awens Alphonse, Nebi Demez, Brian P. Laffey, Shyam Pokharel, Suresh Rana, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: The Imaging Ring is a mobile digital X-ray system capable of producing 2D planar X-rays, fluoroscopy, and 3D Cone-Beam Computed Tomography (CBCT) images. This study aimed to evaluate the long...

MR-Based Functional Liver Imaging and Dosimetry to Predict Albi Change Post-SBRT

Authors: Madhava Aryal, James M. Balter, Yue Cao, Daniel T Chang, Kyle Cuneo, Joseph R. Evans, Theodore Lawrence, John Rice, Randall K. Ten Haken, Lise Wei

Affiliation: University of Michigan, Department of Radiation Oncology University of Michigan

Abstract Preview: Purpose: This study aims to identify predictors of global liver function change measured by albumin-bilirubin (ALBI) score following stereotactic body radiation therapy (SBRT) in hepatocellular carcin...

NA-Unetr: A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

Authors: Hassan Bagher-Ebadian, Ahmed I Ghanem, Joshua P. Kim, Chengyin Li, Rafi Ibn Sultan, Kundan S Thind, Dongxiao Zhu

Affiliation: Wayne State University, Department of Radiation Oncology, Henry Ford Health-Cancer, Detroit, MI and Alexandria Department of Clinical Oncology, Faculty of Medicine, Alexandria University, Henry Ford Health

Abstract Preview: Purpose: Accurate segmentation of the Left Anterior Descending (LAD) artery in free-breathing 3D treatment planning CT is crucial for radiotherapy but remains challenging due to its small size, comple...

Optimization of Impulsed Acquisition Protocols on 1.5T MRI Using Simulation-Based Bayesian Experimental Design for Cell Size Imaging

Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li, Junzhong Xu

Affiliation: Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiology, Vanderbilt University Medical Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cell size is a vital parameter in evaluating the tumor microenvironment, including cell apoptosis and radiotherapy(RT)-induced immune cell infiltration. The IMPULSED(Imaging Microstructural P...

Optimizing Fractionation Schedules for De-Escalation Radiotherapy in Head and Neck Cancers Using Deep Reinforcement Learning

Authors: Zhongjie Lu

Affiliation: Department of Radiation Oncology, The First Affiliated Hospital, Zhejiang University School of Medicine

Abstract Preview: Purpose: Patients with locally-advanced head and neck squamous cell carcinomas(HNSCCs), particularly those related to human papillomavirus(HPV), often achieve good locoregional control(LRC), yet they ...

Photon-Proton Treatment Compatible Couch Tops Render Modality-Dependent Support Structure Models

Authors: Estelle Batin, Michael A. Carlson, Nilendu Gupta, Zachary X. Richards, Diana Shvydka

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center

Abstract Preview: Purpose: With an increase in world-wide proton treatment availability, patients sometimes are transferred between proton and photon modalities. Among the main reasons for modality shifts are proton be...

Proposed Method for Optimization of Lattice Radiation Therapy Using an Advanced Ring Gantry Linac

Authors: Eduardo Florian, Osmar Obdulio Hernandez, Otto Hurtarte, Milton Ixquiac, Erick Orlando Montenegro, Franky Eduardo Reyes, Edgar Aparicio Ruiz, Kevin Vega, Vicky de Falla

Affiliation: Liga Nacional Contra el Cancer, Liga Nacional Contra el Cancer/INCAN, Liga Nacional Contra el Cancer / INCAN, Liga Nacional Contra el Cancer and Universidad de San Carlos de Guatemala, Liga Nacional Contra el Cáncer / INCAN

Abstract Preview: Introduccion:
Lattice Radiation Therapy (LRT) is a form of spatially fractionated radiation therapy (SFRT) designed to improve control of large tumors by delivering ablative doses while minimizing ...

Radiation Shielding Considerations for Ultra-High Dose Rate Electron Flash Radiation Therapy

Authors: Alexandru Badalan, Peter Petric, I. Antoniu Popescu, Andrew Kyle Henderson Robertson

Affiliation: Bc Cancer, BC Cancer - Vancouver, BC Cancer

Abstract Preview: Purpose: Ultra-high dose rate (>40 Gy/s) or “FLASH” radiation therapy (RT) has the potential to improve cancer treatment through reduced radiation side effects. While electron FLASH beams can be produ...

Radiodynamic Therapy: Inhibiting Metastases of Small Cell Lung Cancer In Vivo

Authors: Lili Chen, Andy T. Clark, Dusica Cvetkovic, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Radiodynamic therapy (RDT) shows promise as a strategy to inhibit the metastasis of premetastatic small cell lung cancer (SCLC). This study evaluates the therapeutic effect of RDT in inhibiti...

Real Time Monte Carlo Dose Calculation for Clinical Cyberknife Radiation Therapy Based on Deep Learning Diffusion Model

Authors: Ruiyan Du, He Huang, Mingzhu Li, Ying Li, Hongyu Lin, Wei Liu, Shihuan Qin, Yiming Ren, Hui Xu, Lian Zhang, Xiao Zhang, Zunhao Zhang

Affiliation: Department of Radiation Oncology, Mayo Clinic, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Monte Carlo (MC) dose calculation is the gold standard in clinical CyberKnife radiation therapy (RT), considering its steep dose gradients and high-freedom non-coplanar beam angles, but extre...

Respiratory Monitoring in Human Subjects Using a Low-Cost Optical Imaging System Prototype

Authors: Marian Axente, Mandeep Kaur

Affiliation: Emory University

Abstract Preview: Purpose: To validate a low-cost optical imaging system for respiratory monitoring by comparing its accuracy and feasibility against the clinical gold standard in human subjects.
Methods: Following ...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...

Small but Mighty: A Lightweight and Computationally Efficient Model for Deformable Image Registration

Authors: Hengjie Liu, Dan Ruan, Ke Sheng, DI Xu

Affiliation: Physics and Biology in Medicine, University of California, Los Angeles, Department of Radiation Oncology, University of California, San Francisco, Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose:
State-of-the-art deep learning-based deformable image registration often uses large, complex models directly adapted from computer vision tasks but achieves only comparable performance to ...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

Streamlining Orthovoltage QA: Feasibility of IC Profiler Dosimetry and Workflow Optimization

Authors: Huixiao Chen, Zhe (Jay) Chen, MinYoung Lee, Sameer Taneja

Affiliation: Yale School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Superficial radiation therapy uses low-energy x-rays to treat various types of cancers, including non-melanoma skin cancers, and dermatological conditions such as keloid scars, mycosis fungoi...

The Feasibility of Ethos-Based Pulsed Reduced Dose-Rate (PRDR) Radiotherapy

Authors: Chia-Lung Chien, Renteng Hou, Wen C. Hsi, Faraz Kalantari, Ganesh Narayanasamy, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
PRDR is an effective re-irradiation treatment for patients who have already reached the tolerance dose to their organs at risk (OARs). While PRDR is implemented on TrueBeam by limiting the...

Transformer-Based Proton Dose Prediction with and without Diffusion Process

Authors: Jing Qian, Brandon Reber, David M. Routman, Satomi Shiraishi

Affiliation: Mayo Clinic

Abstract Preview: Purpose: The dose distribution in proton radiotherapy (PRT) is characterized by sharp gradients, posing a challenge for machine learning-based dose prediction. While denoising with diffusion processes...

Two-Stage Clustering and Auto Machine Learning to Predict Chemoradiation Response in Tumor Subregions on FDG PET for La-NSCLC

Authors: Stephen R. Bowen, Shijun Chen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Qianqian Tong, Jiajie Wang, Shouyi Wang, Faisal Yaseen

Affiliation: The University of Texas at Austin, Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Fred Hutchinson Cancer Center, University of Texas at Arlington

Abstract Preview: Purpose: Tumor subregion clustering and prediction of region-specific response can augment assessments and adaptive treatment decisions. A modeling framework was constructed to predict chemoradiation ...

Ultra-Sparse-View Cone-Beam CT Reconstruction Based Strictly-Structure-Preserved Deep Neural Network in Image-Guided Radiation Therapy

Authors: Guangjun Li, Ying Song, Huanan Tang, Tianxiong Wu, Qiuyi Ye, Wei Zhang

Affiliation: West China Second Hospital of Sichuan University, United Imaging Healthcare, West China Hospital of Sichuan University

Abstract Preview: Purpose:
To propose a general low-dose reconstruction model for ultra-sparse-view cone-beam CT (CBCT) and evaluate its clinical application in improving image quality and reducing radiation dose fo...

Universal Anatomical Mapping and Patient-Specific Prior Implicit Neural Representation for MRI Super-Resolution

Authors: Jie Deng, Yunxiang Li, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Magnetic Resonance Imaging (MRI) has exceptional soft tissue contrast and an essential role in radiotherapy. The introduction of clinical MR-LINACs has enabled adaptive radiotherapy (ART) usi...