Authors: Xiaoxue Qian, Hua-Chieh Shao, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) reduces imaging time and dose but suffers from under-sampling artifacts. 2D–3D deformable registration addresses this problem by estimating LA-CBCTs from defor...
Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University
Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...
Authors: Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu, Jie Zhang
Affiliation: University of Maryland School of Medicine, University of California, Irvine
Abstract Preview: Purpose: To achieve the full-view image from a single-view sinogram using a two-stage deep learning model for electroacoustic-tomography (EAT), which is an emerging imaging technique with significant ...
Authors: Kostas Danniidis, Agelos Kratimenos, Yufu Wang, Timothy C. Zhu, Yifeng Zhu
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: This study aims to develop software and algorithms utilizing artificial intelligence (AI) to seamlessly create 3D patient postures during Total Skin Electron Therapy (TSET). The resulting mes...
Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou
Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation
Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...
Authors: Peter Balter, Kristy K. Brock, Clifton David Fuller, Tze Yee Lim, James Long, Brigid A. McDonald, Androniki Mitrou, Andrew J. Schaefer, Stina Svensson
Affiliation: The University of Texas MD Anderson Cancer Center, RaySearch Laboratories, Rice University, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences
Abstract Preview: Purpose: CBCT-based accumulated dose can provide up-to-date dose information on responding anatomy. To optimize resources, it is necessary to determine how many scans provide adequate information for ...
Authors: Penghao Gao, Zejun Jiang, Huazhong Shu, Linlin Wang, Gongsen Zhang, Jian Zhu
Affiliation: Laboratory of Image Science and Technology, Key Laboratory of Computer Network and Information Integration, Southeast University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
Abstract Preview: Purpose: We propose a cascading framework for time-varying anatomical volumetric reconstruction and tumor-tracking, guided by onboard orthogonal-view X-ray projections.
Methods: We employe multiple...
Authors: Xiaoyi Dai, Manju Liu, Weiwei Sang, Pulin Sun, Fan Xia, Zhenyu Yang, Fang-Fang Yin, Chulong Zhang, Rihui Zhang
Affiliation: Jiahui International Hospital, Radiation Oncology, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
Current deep learning-based sparse-view CBCT reconstruction methods are prone to hallucinatory artifacts, as they rely on inferred image details that may not correspond to true anatomical ...
Authors: Jongduk Baek, Jooho Lee, Adam S. Wang
Affiliation: Stanford University, Yonsei University
Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...
Authors: Lei Ren, Jie Zhang
Affiliation: University of Maryland School of Medicine
Abstract Preview: Purpose: 4D-CBCT is valuable for imaging anatomy affected by respiratory motions to guide radiotherapy delivery. However, 4D-CBCT often has undersampled projections acquired in each respiratory phase ...
Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha, Somol Sunny
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: Accurate delineation of the urethra is critical for optimizing tumor control and minimizing urethral toxicity in prostate stereotactic body radiation therapy (SBRT). The purpose of this study...
Authors: Ramesh Boggula, Jay W. Burmeister
Affiliation: Wayne State University, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine
Abstract Preview: Purpose: This study evaluated the performance of a hybrid Compton camera for real-time imaging during the administration of Lu-177-based radiopharmaceuticals, including Pluvicto and Lutathera. The aim...
Authors: Oluyemi Bright Aboyewa, KyungPyo Hong, Daniel Kim
Affiliation: Department of Radiology, Northwestern University
Abstract Preview: Purpose: While non-Cartesian MRI is desirable for fast imaging with high spatial resolution and robustness to motion, it requires long post-processing times. Preconditioning with an adequate density c...
Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC
Abstract Preview: Purpose: The goal of the HyperSight® offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...
Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: For soft-tissue abdominal tumors, a 4D-MR may provide improved tumor tracking over the clinical standard 4D-CT. This project aims to optimize a clinically available 4D-MR pulse sequence to ac...
Authors: Gregory J Bootsma, Tunok Mondol
Affiliation: University Health Network, Princess Margaret Cancer Center
Abstract Preview: Purpose:
To evaluate the impact of prototype fluence field modulation (FFM) cone-beam CT (CBCT) on dose reduction and image quality using Monte Carlo simulations. This study particularly looks at t...
Authors: Hassan Bagher-Ebadian, Ahmed I Ghanem, Joshua P. Kim, Chengyin Li, Rafi Ibn Sultan, Kundan S Thind, Dongxiao Zhu
Affiliation: Wayne State University, Department of Radiation Oncology, Henry Ford Health-Cancer, Detroit, MI and Alexandria Department of Clinical Oncology, Faculty of Medicine, Alexandria University, Henry Ford Health
Abstract Preview: Purpose: Accurate segmentation of the Left Anterior Descending (LAD) artery in free-breathing 3D treatment planning CT is crucial for radiotherapy but remains challenging due to its small size, comple...
Authors: Ivan M. Buzurovic, Evangelia Kaza
Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology
Abstract Preview: Purpose: Recent advances allow for depiction of surface brachytherapy flap applicators using MRI, with empty catheters detected by signal intensity reduction. As manual catheter detection is subjectiv...
Authors: Jennifer Kwak, Chelsea Manica, Justin K. Mikell, Michael Silosky, Wendy Siman
Affiliation: Washington University School of Medicine in St. Louis, University of Colorado Anschutz Medical Campus, School of Medicine, Rocky Vista University
Abstract Preview: Purpose:
This study evaluates synthetic planar imaging (synP) from SPECT projections against conventional planar imaging, focusing on detectability, spatial resolution, and feasibility. SynP allows...
Authors: Guangjun Li, Ying Song, Huanan Tang, Tianxiong Wu, Qiuyi Ye, Wei Zhang
Affiliation: West China Second Hospital of Sichuan University, United Imaging Healthcare, West China Hospital of Sichuan University
Abstract Preview: Purpose:
To propose a general low-dose reconstruction model for ultra-sparse-view cone-beam CT (CBCT) and evaluate its clinical application in improving image quality and reducing radiation dose fo...