Search Submissions 🔎

Results for "fully sampled": 25 found

A Combination of Radiomics and Dosiomics for Gross Tumor Volume Regression in Personalized Ultra-Fractionated Stereotactic Adaptive Radiotherapy (PULSAR)

Authors: Hao Peng, Yajun Yu

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Personalized ultra-fractionated stereotactic adaptive radiotherapy (PULSAR) is a novel ablative radiation dosing scheme developed by our institution. This study aims to establish a regression...

A Hybrid Population-Based and Patient-Specific Framework for 2D–3D Deformable Registration-Driven Limited-Angle Cone-Beam CT Estimation

Authors: Xiaoxue Qian, Hua-Chieh Shao, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) reduces imaging time and dose but suffers from under-sampling artifacts. 2D–3D deformable registration addresses this problem by estimating LA-CBCTs from defor...

A Hybrid-PCA Based Accelerated MR Method for Real-Time Target Tracking and Motion Management

Authors: B. Gino Fallone, Keith D. Wachowicz, Mark G. Wright, Jihyun Yun

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com

Abstract Preview: Purpose: This work focusses on a hybrid Principal Component Analysis (PCA) based MR acceleration method for prospectively acquired undersampled data on a hybrid MR-Linac system for real-time target-tr...

A Single-View-Based Electroacoustic Tomography Imaging Using Deep Learning for Electroporation Monitoring

Authors: Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of California, Irvine

Abstract Preview: Purpose: To achieve the full-view image from a single-view sinogram using a two-stage deep learning model for electroacoustic-tomography (EAT), which is an emerging imaging technique with significant ...

Adversarial Diffusion-Based Self-Supervised Learning for High-Resolution MR Imaging

Authors: Zachary Buchwald, Chih-Wei Chang, Zach Eidex, Richard L.J. Qiu, Mojtaba Safari, Shansong Wang, Xiaofeng Yang, David Yu

Affiliation: Emory University and Winship Cancer Institute, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: MRI offers excellent soft tissue contrast for diagnosis and treatment but suffers from long acquisition times, causing patient discomfort and motion artifacts. To accelerate MRI, supervised d...

Application of the Lymphodose Framework to Brain Tumors: Unveiling the Prognostic Power of Circulating Lymphocyte Doses

Authors: Sophie Bockel, Eric Deutsch, Frederic Dhermain, Ibrahima Diallo, Anh Thu Le, Elaine Limkin, Pauline Maury, Charlotte Robert, Killian Sambourg, Camilla Satragno, Cristina Veres, François de Kermenguy

Affiliation: Gustave Roussy, Département de radiothérapie, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose:
To study the correlation between the dose to circulating lymphocytes as evaluated by the LymphoDose framework and the incidence of severe radiation-induced lymphopenia (sRIL) in patients t...

BEST IN PHYSICS ULTRASOUND: A Calibration Framework for Quantifying Element Misalignment in 2D Matrix Array Transducers Used in 3D Quantitative Ultrasound

Authors: Cristel Baiu, Laura Castaneda Martinez, Ivan M. Rosado-Mendez

Affiliation: University of Wisconsin, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: 2D matrix array transducers (2DMAT) are advancing volumetric ultrasound due to their ability to provide more isotropic 3D resolution, fast volumetric imaging, and highly customizable focusing...

Backward Photon Monte Carlo Propagator (BPMCP): Proof of Concept of a Fully Physics-Driven SPECT Reconstruction

Authors: Alejandro Bertolet, Carlos Huesa-Berral, Victor V. Onecha

Affiliation: Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Radioembolization for liver tumors using 90Y microspheres uses SPECT as confirmatory dosimetry, although 90Y is a pure β-emitter, and SPECT-imaging is only available through subsequent bremss...

Comparative Analysis of Nine Deep Learning Architectures for Variable Density Grappa 1H Magnetic Resonance Spectroscopy Imaging (MRSI) Reconstruction

Authors: Kimberly Chan, Anke Henning, Mahrshi Jani, Andrew Wright, Xinyu Zhang

Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center

Abstract Preview: Purpose: To evaluate the performance of multiple deep learning architectures for MRSI reconstruction and determine their effectiveness in maintaining high-resolution metabolite mapping while reducing ...

Contrast-Free Full Intracranial Vessel Geometry Estimation from MRI with Metric Learning-Based Inference

Authors: Zhaoyang Fan, Eric Nguyen, Dan Ruan, Jiayu Xiao

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of Southern California, University of Southern California

Abstract Preview: Purpose: MR vessel wall imaging (VWI) has been shown to be effective for evaluating intracranial atherosclerosis disease. However, VWI typically also requires an MR angiography (MRA) in the same imagi...

Deep-Learning Based Spectral Artifact Removal with In Vivo 7T Proton MRSI Data

Authors: Anke Henning, Mahrshi Jani, Tianyu Wang, Andrew Wright, Xinyu Zhang

Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center

Abstract Preview: Purpose: Proton MRSI offers critical metabolic insights into diseased brain processes but is prone to artifacts, and current post-processing methods are often insufficient, resulting in low-quality da...

Differential Gastrointestinal Responses to Synchrotron-Produced Proton and Electron Irradiation Under Flash and Conventional Conditions

Authors: Luke Connell, Nolan M. Esplen, Elise Konradsson, Albert C. Koong, Ziyi Li, Steven Hsesheng Lin, Kevin Liu, Billy W Loo, Devarati Mitra, Radhe Mohan, Emil Schueler, Takeshi Takaoka, Uwe Titt, Xiaochun Wang, Ming Yang

Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study aimed to assess radiation-induced gastrointestinal (GI) toxicity in mice subjected to abdominal irradiation using protons at ultra-high-dose-rate (UHDR) and conventional dose-rates...

Direct Measurement of DNA Damage to Determine Dose and Biological Effectiveness

Authors: Michael Lamontagne, Ileana Pazos, Jerimy C. Polf, Joseph W. Robertson, Teniola Tobun, Ronald E. Tosh, Michael Zwolak

Affiliation: Biophysics and Biomedical Research Group, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, M3D, Inc, National Institute of Standards and Technology, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To study how damage to DNA molecules increases and changes as a function of the type and dose of radiation.

Methods: DNA molecules of a known length (number of base pairs (BP)) within ...

Enhance Four-Dimension Cone-Beam Computed Tomography (4D-CBCT) from Sparse Views Using a Novel Deep Learning Model

Authors: Lei Ren, Jie Zhang

Affiliation: University of Maryland School of Medicine

Abstract Preview: Purpose: 4D-CBCT is valuable for imaging anatomy affected by respiratory motions to guide radiotherapy delivery. However, 4D-CBCT often has undersampled projections acquired in each respiratory phase ...

Ensuring Consistency in Digital Pathology: Medical Physics Approaches to Comparison of Scanner Sharpness and Artifact Severity

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Xiang Li, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Medical physicists traditionally support radiation-based medicine, but their expertise is translatable to image-based fields like pathology. As pathology transitions to digital practices, phy...

Evaluation of an Adaptive Denoising Diffusion Probabilistic Model (DDPM) for Fast MRI in Radiotherapy Planning of Pediatric Brain Tumors

Authors: Chia-Ho Hua, Jirapat Likitlersuang, Jinsoo Uh

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: AI-based fast MRI, which reconstructs images from undersampled k-space data, has not yet been tailored for RT planning. This study aims to evaluate the fast MRI performance of our recently pr...

Exploring Quantifiable Features of the Fracture Healing Process

Authors: Jung Gyu Chi, Sungwook Choi, Don-Soo Kim

Affiliation: IAM ORTHOPAEDIC CLINIC, Boston Children's Hospital/Harvard Medical School, Massachusetts College of Pharmacy and Health Science

Abstract Preview: Purpose: To explore quantifiable parameters of the fracture healing process to aid physicians in determining the treatment plan for intramedullary nailing removal.
Methods: In contrast to conventio...

Geometrically Derived Density Compensation Function for 3D Non-Cartesian MRI Reconstruction

Authors: Oluyemi Bright Aboyewa, KyungPyo Hong, Daniel Kim

Affiliation: Department of Radiology, Northwestern University

Abstract Preview: Purpose: While non-Cartesian MRI is desirable for fast imaging with high spatial resolution and robustness to motion, it requires long post-processing times. Preconditioning with an adequate density c...

Impact of Tumor-to-Normal Ratio and Glass Microsphere Particle Density on Local Progression-Free Survival Following Lobar Yttrium-90 Radioembolization

Authors: Jason Chiang, Magnus Dahlbom, Veronica Hankil, Xinyi Li, Catherine (Caffi) Meyer, Kyung Hyun Sung

Affiliation: UCLA, University of California, Los Angeles

Abstract Preview: Purpose:
Yttrium-90 (90Y) radioembolization is a well-established therapy for large or multifocal liver tumors. Accurate dosimetry is critical but remains challenging, as low particle density risks...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Multimodal Attention Fusion Model Leveraging Structured and Unstructured EHR Data for Hospital Readmission Prediction in Head and Neck Cancer

Authors: Shreyas Anil, Jason Chan, Arushi Gulati, Yannet Interian, Hui Lin, Benedict Neo, Andrea Park, Bhumika Srinivas

Affiliation: Department of Otolaryngology Head and Neck Surgery, University of California San Francisco, Department of Data Science, University of San Francisco, Department of Radiation Oncology, University of California San Francisco

Abstract Preview: Purpose: Hospital readmission prediction models often rely on structured Electronic Health Record (EHR) data, overlooking critical insights from unstructured clinical notes. This study presents a mult...

Multimodal Framework for Predicting Radiation-Induced Severe Acute Esophagitis in Esophageal Cancer

Authors: Yeona Cho, Chloe Min Seo Choi, Joseph O. Deasy, Jue Jiang, Jihun Kim, Jin Sung Kim, Nikhil Mankuzhy, Aneesh Rangnekar, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu

Affiliation: University of Freibrug, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Memorial Sloan Kettering Cancer Center, Yonsei University

Abstract Preview: Purpose: We hypothesized that combining clinical, imaging, and radiotherapy dose-distribution features could increase predictive model accuracy in radiation-induced severe acute esophagitis (SAE) in e...

Neural Implicit K-Space for Accelerated Patient-Specific Non-Cartesian MRI Reconstruction

Authors: Daniel O Connor, Mary Feng, Hui Lin, Hengjie Liu, Xin Miao, Michael Ohliger, Jess E. Scholey, Ke Sheng, DI Xu, Wensha Yang, Yang Yang

Affiliation: UCSF, University of California, Los Angeles, Department of Radiation Oncology, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco, Department of Radiation Oncology, University of California at San Francisco, University of San Francisco, Department of Radiology, University of California, San Francisco, University of California San Francisco, Siemens Medical Solutions USA Inc.

Abstract Preview: Purpose: The scanning time for a fully sampled MRI is lengthy. Compressed sensing (CS) has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is...

Research on Multi-Organ Segmentation Based on Cross-Domain Transfer Learning

Authors: Jiali Gong, Yi Guo, Chi Han, Wanli Huo, Hongdong Liu, Zhao Peng, Yaping Qi, Zhaojuan Zhang

Affiliation: Department of Radiotherapy, cancer center, The First Affiliated Hospital of Fujian Medical University, Department of Oncology, Xiangya Hospital, Central South University, State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Guangdong Provincial Clinical Research Center for Cancer, Sun Yat-sen University Cancer Center, China Jiliang University, Division of lonizing Radiation Metrology, National Institute of Metrology, Key Laboratory of Electromagnetic Wave Information Technology and Metrology of Zhejiang Province, College of Information Engineering, China Jiliang University, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: To address overfitting from limited training data in multi-organ segmentation, an efficient transfer learning framework is proposed. It reduces reliance on training samples, enabling a single...

Ultra-Fast Commissioning and Quality Assurance with Plastic Scintillation Detector

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: Accurate, efficient, and reliable commissioning of linear accelerator (LINAC) is critical for ensuring high-quality radiation therapy treatments. The study uses advanced detector technology a...