Authors: Shashanksharad Kale, Gopishankar Natanasabapathi, Daya Nand Kishore Sharma
Affiliation: All India Institute of Medical Sciences (AIIMS), Department of Radiation Oncology, All India Institute of Medical Sciences
Abstract Preview: Purpose:
The study demonstrates a novel 3D printing method to fabricate an ion chamber insert (ICI) for absolute dosimetry purpose in gamma knife radiosurgery (GKRS).
Methods:
Our institute u...
Authors: Jamieson Baker, Emel Calugaru, Yijian Cao, Jenghwa Chang, Jessica Jung, Jian Liu, Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke
Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health, Hofstra University Medical Physics Program
Abstract Preview: Purpose: Our hospital network has options to treat recurrent glioblastoma (GBM) with surgically targeted Cesium-131 brachytherapy, external beam stereotactic radiotherapy (SRT) with Varian TrueBeam, H...
Authors: Tsuicheng D. Chiu, Strahinja Stojadinovic, Aaron Thomlinson, You Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas Southwestern Medical Center, University of Texas Southwestern Medical Center
Abstract Preview: Purpose: Design and develop an automated verification and validation platform for the Elekta Leksell Gamma Knife (GK) Icon/Esprit High-Definition Motion Management (HDMM) system.
Methods: The H...
Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng
Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester
Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...
Authors: Deepak Agrawal, Subhash Gupta, Shashanksharad Kale, Gopishankar Natanasabapathi, Manoj Phalak, Dhanabalan Rajasekaran, Surendra Kumar Saini, Subramani Vellaiyan
Affiliation: All India Institute of Medical Sciences (AIIMS), All India Institute of Medical Sciences
Abstract Preview: Purpose:
To evaluate planning strategy for uveal melanoma tumor (UM) in gamma knife stereotactic radiosurgery (GKSRS) using Lightning inverse planning software for treatment planning.
Methods:
Authors: Zachery Colbert, Matthew Foote, Michael Huo, Mark Pinkham, Prabhakar Ramachandran, Mihir Shanker
Affiliation: Radiation Oncology, Princess Alexandra Hospital, Ipswich Road, Princess Alexandra Hospital
Abstract Preview: Purpose: The study aimed to develop and implement deep learning-based autosegmentation models for the autosegmentation of four key tumor types: brain metastasis, pituitary adenoma, vestibular schwanno...
Authors: Sven Ferguson, S. Murty Goddu, Ana Heermann, Taeho Kim, Nels C. Knutson, Hugh HC Lee, Shanti Marasini, Timothy Mitchell, Seungjong Oh, Kevin Renick
Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis
Abstract Preview: Purpose: In the Gamma Knife stereotactic radiosurgery (GK-SRS), the delineation of organs-at-risks (OARs) was not fully automated. Due to the cumbersome nature of manual OAR contouring, dose evaluatio...
Authors: Madeleine Arbogast, David Dorndos, Denise E Foltz, Justin Fraser, Damodar Pokhrel, William St Clair
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Neurosurgery, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: For stereotactic radiosurgery (SRS) treatments of intracranial arteriovenous malformations (AVM) and fistulas (AVF), same-day Leksell Gamma Knife (GK) is the preferred modality. Long-term cli...
Authors: Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose: The objective of this study is to systematically evaluate and validate the performance of a commercially available 3D Linear stage device as a quality assurance (QA) tool to validate position...
Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...
Authors: Chih-Wei Chang, Runyu Jiang, Mark Korpics, Yuan Shao, Aranee Sivananthan, Zhen Tian, Ralph Weichselbaum, Xiaofeng Yang, Aubrey Zhang, Xiaoman Zhang
Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Department of Physics, University of Chicago, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, School of Public Health, University of Illinois Chicago
Abstract Preview: Purpose: Gamma Knife (GK) plan quality can vary significantly among planners, even for cases handled by the same planner. Although plan quality metrics such as coverage, selectivity, and gradient inde...
Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...
Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...
Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Wenyin Shi, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: Multi-target stereotactic radiosurgery (SRS) planning poses challenges due to complex geometries, small target volumes, and steep dose gradients. Achieving a balance between target coverage a...
Authors: Thomas R. Bortfeld, Prof. Elisabetta De Bernardi, Tianxue Du, Beatrice Foglia, Chiara Gianoli, Takamitsu Masuda, Katia Parodi, Marco Pinto, Boon-Keng Kevin Teo, Yunhe Xie
Affiliation: Department Of Radiation Oncology, Massachusetts General Hospital (MGH), School of Medicine and Surgery, University of Milano-Bicocca, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, National Institutes for Quantum Science and Technology (QST), University of Pennsylvania, Department of Experimental Physics - Medical Physics, Ludwig-Maximilians-Universität (LMU) München
Abstract Preview: Purpose: The full potential offered by protons in clinical practice is limited by range uncertainties. One possibility for monitoring is through secondary prompt gammas (PG). PG emission along the pen...
Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard
Affiliation: Warren Alpert Medical School of Brown University
Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...
Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic
Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center
Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...
Authors: Damien C. Mathew, Brandon Hai Nguyen, Satwik Pani, Yoichi Watanabe
Affiliation: Minnespolis Radiation Oncology, Department of Radiation Oncology, University of Minnesota Medical School, Washington University
Abstract Preview: Purpose: To formulate a computational algorithm to quantify the tumor movement from the motion data of landmarks on the brain surface. To estimate the magnitude of tumor movement when the head makes a...
Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang
Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center
Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...
Authors: Omar Awad, Alfredo Enrique Echeverria, Issam M. El Naqa, Daniel Allan Hamstra, Yiding Han, Ryan Lafratta, Abdallah Sherif Radwan Mohamed, Piyush Pathak, Zaid Ali Siddiqui, Baozhou Sun, Vincent Ugarte
Affiliation: H. Lee Moffitt Cancer Center, Harris Health, Baylor College of Medicine
Abstract Preview: Purpose:
Accurate detection and segmentation of brain metastases are critical for diagnosis, treatment planning, and follow-up imaging but are challenging due to labor-intensive manual assessments ...
Authors: Robert A. Dahl
Affiliation: Mayo Foundation
Abstract Preview: Purpose: To develop tools to simplify/accelerate the quality assurance testing of the Mobetron mobile linear accelerator and increase safety when moving it to different OR’s.
Methods: The Mobet...
Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens
Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto
Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...
Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Richard A. Popple, Wenyin Shi, Rodney J. Sullivan, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao
Affiliation: Thomas Jefferson University, The University of Alabama at Birmingham, University of Alabama at Birmingham
Abstract Preview: Purpose: Objectively evaluating brain sparing as a plan-quality indicator for patients receiving stereotactic radiosurgery (SRS) to multiple metastases (multi-met) is complicated by variability in tar...
Authors: Brankica Andelic, Young-Bin Cho, Tara M. Gray, Andrew Robert Hadfield, Hakan Nordstrom
Affiliation: Elekta, Cleveland Clinic
Abstract Preview: Purpose: Spatially Fractionated Radiotherapy (SFRT) requires highly modulated dose distribution inside a tumor volume optimized using sets of planning structure of spheres in a lattice arrangement. To...
Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan
Affiliation: Medical University of South Carolina
Abstract Preview: Purpose:
This study evaluates optimization strategies in the Gamma Knife Gamma Plan Lightning optimizer for simultaneous integrated boost (SIB) scenarios, aiming to identify clinically viable setti...
Authors: Nina Burbure, Tawfik G. Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang
Affiliation: FCCC at Temple University Hospital
Abstract Preview: Purpose: Frameless gamma knife (GK) treatments use a thermoplastic mask coupled with high-definition motion management system that utilizes an infrared camera, and a reflective marker placed on the pa...
Authors: Brankica Andelic, Young-Bin Cho, Tara M. Gray, Bingqi Guo, Andrew Robert Hadfield, Hakan Nordstrom, Jacob Scott, John Suh, Nara Yoon
Affiliation: Adelphi University, Elekta, Cleveland Clinic
Abstract Preview: Purpose: To investigate the biological effect of Spatially Fractionated Radiation Therapy (SFRT) within Gamma-Knife (GK) using retrospective planning for brain metastases patients. This study presents...
Authors: Carl D. Elliston, Lawrence Koutcher, Michael J. Price, Adam C. Riegel, Michael B Sisti, Tony J.C. Wang, Andy (Yuanguang) Xu
Affiliation: Columbia University Irving Medical Center
Abstract Preview: Purpose: An inverse treatment planning software was recently introduced to Gamma Knife radiosurgery. The purpose of this study is to compare the plan quality of the Gamma Knife ”Lightning” with that o...
Authors: William Amestoy, Carolina Benjamin, Markus Bredel, Rodrigo Delgadillo, Nesrin Dogan, Michael E Ivan, Ricardo J Komotar, Gregory J. Kubicek, Eric Mellon, Ivaylo B. Mihaylov, Maria Irene Monterroso, Raymond A. Schulz, Ashish Shah, Robert M Starke
Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, Varian Medical Systems
Abstract Preview: Purpose: Stereotactic Radiosurgery (SRS) is a widely used treatment modality in radiation oncology, utilizing various technologies such as Gamma Knife (GK), Cyber Knife (CK) and Linac-based SRS with H...