Authors: Huixiao Chen, Ethan Hartowicz, Lichung Ku, Tim Perez, Ray Yang
Affiliation: Salem Health, RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: To characterize MV-kV isocenter offset on a novel ring gantry radiotherapy system where the Linac, PET, kV-CT, and MV imaging subsystems rotate together at native operating speed of 60RPM.
Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr
Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado
Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...
Authors: Wenhua Cao, Xianjin Dai, PhD, Hadis Moazami Goudarzi, Gino Lim, Miaolan Xie, Lei Xing, Lewei Zhao
Affiliation: University of Chicago Booth School of Business, Department of Radiation Oncology, Stanford University, Department of Industrial Engineering, University of Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Proton Arc Therapy (PAT) delivers a continuous dose of radiation during gantry rotation. 4π is a non-coplanar technique used for advanced proton therapy delivery. This work proposes a hybrid ...
Authors: Jonathan Dowell, Grace Francis, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Iridesce Solutions, Inc.
Abstract Preview: Purpose: A novel radiation therapy quality assurance (RT QA) device has been designed, constructed and tested. The nüFilmTM machine QA system provides a method for collecting light, mechanical and rad...
Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis
Affiliation: Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory
Abstract Preview: Purpose:
Dual-layer kV imager (DLI) architecture enables the capability for single-shot dual-energy (DE) intrafraction imaging. As noise from individual DLI layers are primarily uncorrelated, simpl...
Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health
Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...
Authors: Ye Chen, Koki Kasamatsu, Taeko Matsuura, Taichi Murakami
Affiliation: Hokkaido University, National Institutes for Quantum Science and Technology (QST)
Abstract Preview: Purpose: In proton therapy, CT-based estimation of the stopping power ratio (SPR) is a significant source of range uncertainty. Protoacoustics have been developed to estimate the range in vivo, but fe...
Authors: Daming LI, Jinsen Xie, Zhe Zhang
Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China
Abstract Preview: Purpose:
This study aims to investigate the feasibility of online dose measurement of the Trilogy linear accelerator output based on target current pulse signals.
Methods:
A data acquisition ...
Authors: Zachary M. Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: High spatial resolution in pin ridge filter (pRF)-based proton planning may be constrained by the 1mm dose grid resolution in commercial treatment planning systems. This study investigates th...
Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park
Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital
Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...
Authors: Maria Jose Almada, Bruno Forti, Andres Lima, Carlos Daniel Venencia
Affiliation: Instituto Zunino - Fundacion Marie Curie
Abstract Preview: Purpose:
To automate the planning of radiotherapy treatments for bone metastases using a script in the ECLIPSE planning system version 15.6 with a graphical interface.
Methods:
A script was d...
Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou
Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation
Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...
Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos
Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen
Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...
Authors: Casey E. Bojechko, Lance C Moore
Affiliation: University of California, San Diego, University of California San Diego
Abstract Preview: Purpose: EPID images collected during treatment can serve as an in-vivo error detection mechanism. Previous works have shown that comparing in-vivo EPID images to AI-predicted EPID images for IMRT pla...
Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Iowa, Iowa Health Care
Abstract Preview: Purpose: In proton therapy, the substantial size of the gantry introduces sag, causing the proton isocenter to drift as a function of gantry angle. While the scanning magnets correct the beam’s isocen...
Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang
Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment
Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...
Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang
Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...
Authors: Niko Ahjoniemi, Antti Kulmala, Katja Peltola
Affiliation: Clinical Research Institute HUS, Helsinki University Hospital
Abstract Preview: Purpose: To determine the backlash of a multileaf collimator (MLC) using four measurement methods: motor encoder (primary readout), linear potentiometer (secondary readout), amorphous silicon panel (p...
Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine
Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...
Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani
Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...
Authors: Peter Balter, Andres V Cibrian, Song Gao
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: The purpose of this study is to demonstrate a means of detecting misaligned jaw face angles on the Varian TrueBeam based on a beam symmetry metric for electron beam profiles.
Methods: Duri...
Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...
Authors: Tanxia Qu, Hesheng Wang
Affiliation: NYU Langone Health
Abstract Preview: Purpose:
This study, the second in a two-part series, evaluates the isocenter position (the point in 3D space minimizing the sum of Euclidean distances to the MLC's central axis) and isocenter size...
Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojin Kim, Jin Sung Kim, HO Lee, Sac Lee, Yongdo Yun
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) offers the advantage of a greater relative biological effectiveness (RBE) weighted dose, which must be integrated into the treatment planning system (TPS). This...
Authors: Christopher Ackerman, Chang Chang, Yansong Liu, Stephen Kenneth Northway, Bailey Vallejo
Affiliation: University of California San Diego / California Protons, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center
Abstract Preview: Purpose: To determine mechanical isocenter of a 6-degree-of-freedom (6DOF) couch using radiation isocenter. Coincidence between the isocenters is quantified using MyQA Phoenix amorphous silicon detect...
Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao
Affiliation: Varian AOS @Epic Care, UC Berkeley
Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...
Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang
Affiliation: Levine Cancer Institute, Atrium Health
Abstract Preview: Purpose: To evaluate aperture collimation on a C-shape gantry-mounted proton accelerator. Mevion S250i Hyper scanning machine implemented aperture collimation utilizing adaptive aperture (AA). The AA ...
Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng
Affiliation: UC San Diego, UCSD, University of California San Diego
Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...
Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...
Authors: Shatha Al Afifi, Hana Baroudi, Leonard Che Fru, Laurence Edward Court, Suzanne B. Evans, Kent A. Gifford, Adam D. Melancon, Melissa P. Mitchell, Issa Mohamad, Patricia Murina, Manickam Muruganandham, Tucker J. Netherton, Callistus M. Nguyen, Joshua S. Niedzielski, Deborah L. Schofield, Simona Shaitelman, Willie Shaw, Sanjay S. Shete, Adam Shulman, Brendon Smith, Sheeba Thengumpallil, Carlos Daniel Venencia, Conny Vrieling
Affiliation: University of Cape Town, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, University of the Free State, UT MD Anderson Cancer Center, King Hussein Cancer Center, Instituto Zunino - Fundacion Marie Curie, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Dra., Hirslanden Clinique des Grangettes, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Therapeutic Radiology, Yale University School of Medicine, Yale University, The University of Texas, MD Anderson, Houston TX
Abstract Preview: Purpose:
Automated contouring and planning tools are usually trained on single-institution datasets, seldom tested across diverse patient populations. This introduces a risk of population bias, res...
Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos
Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...
Authors: Anthony Hong Cheol Lim, Rayyan L Mahmood, Alexander Stanforth, Chris C. Wang, Mingyao Zhu
Affiliation: Georgia Institute of Technology, Emory University
Abstract Preview: Purpose: The purpose of this project is to test the feasibility of proton minibeam lattice radiotherapy within an existing clinical setting.
Methods:
The TOPAS code is used to model a scenario i...
Authors: Robert A. Corns, Mohammad Kanber
Affiliation: East Carolina University, East Carolina University Brody School of Medicine
Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...
Authors: Kwang-Ho Cheong, Seungryong Cho, Joonil Hwang, Jae Won Jung, Hoyeon Lee, Raymond Hyunwoo Moon, Inhwan Yeo, Jihyung Yoon
Affiliation: East Carolina University, INOVA Schar Cancer Institute, University of Hong Kong, Hanllym University, KAIST, University of Rochester
Abstract Preview: Purpose: Monitoring a target and neighboring organs during beam delivery is crucial for successful radiotherapy (RT). Conventional transit imaging methods lack volumetric reconstruction capabilities, ...
Authors: Fitria P Krisna, Mardon Limena, Supriyanto Ardjo Pawiro, Jhon H Saragih, Wahyu E. Wibowo, Poonam Yadav, Ummu M Zahro
Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Radiation Oncology Dr. Cipto Mangunkusumo National Central Public Hospital, Department of Physics, Mathematics and Natural Sciences, University of Indonesia, Department of Radiotherapy, Mandaya Hospital, Department of Radiation Oncology, Mitra Keluarga Kenjeran Hospital, Department of Radiotherapy, Mandaya Royal Hospital, Radiation Oncology, Santosa Hospital
Abstract Preview: Purpose: To perform depth dose characteristics of High Dose Electron Beam and utility of various commercially available detectors.
Methods: The measurements were performed using an Elekta Versa HD ...
Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan
Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences
Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...
Authors: Jacqueline M. Andreozzi, Savannah Decker, Diego Hernandez, Iman R. Washington
Affiliation: UC San Diego, Department of Radiation Oncology, Moffitt Cancer Center, University of South Florida, Moffitt Cancer Center
Abstract Preview: Purpose: Recent advances in external beam radiation therapy have begun to explore the utility of Cherenkov radiation imaging as a beam delivery visualization tool. When sheet bolus is used during trea...
Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang
Affiliation: Levine Cancer Institute, Atrium Health
Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...
Authors: Davide Brivio, Erno Sajo, Ryan Williams, Piotr Zygmanski
Affiliation: University of Massachusetts Lowell, Brigham and Women's Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: To develop a non-invasive 3D in-vivo dosimetry tool exploring the relationship between positron annihilations and dose per voxel using Monte Carlo simulation. The Positron Guided Radiation Th...
Authors: Peter Jermain, Ying Niu, Abdul Rashid, Yuan Yuan, Mohammad Zarenia
Affiliation: Medstar Georgetown University Hospital, MedStar Georgetown University Hospital, Department of Radiation Medicine, MedStar Georgetown University Hospital
Abstract Preview: Purpose: ZAP-X is a self-shielded radiosurgery system that utilizes a linac-based isocentric technique and a compact gyroscopic gantry design. While it provides a large solid angle for beam orientatio...
Authors: Liu Hong, Zhong Su
Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)
Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...
Authors: Robert A. Dahl
Affiliation: Mayo Foundation
Abstract Preview: Purpose: To develop tools to simplify/accelerate the quality assurance testing of the Mobetron mobile linear accelerator and increase safety when moving it to different OR’s.
Methods: The Mobet...
Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang
Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University
Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...
Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand
Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami
Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...
Authors: Blessing Chinelo Akah, Brad Barhorst, Daniel W. Neck, David J. Perrin, Chad Robertson, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: To evaluate the performance and radiation isocenter of Elekta and Varian linear accelerator using Aktina Isopoint.
Methods: The Aktina Isopoint was used to measure the physical and radiati...
Authors: Ahmet S. Ayan, Estelle Batin, Austin M. Faught, Peter E. Klages, Eunsin Lee, Collin Nappi, Mina Okello, Meghana Ramani, Zachary X. Richards, Parisa Sadeghi
Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University
Abstract Preview: Purpose: Neutron doses are not modelled in proton treatment planning systems, so measurements were taken with two independent dosimeter types to quantify representative neutron fetal doses in pencil b...
Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Darren M. C. Poon, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung
Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital
Abstract Preview: Purpose: This study investigates optimal treatment strategies utilizing MR-linac for extremity lesions, with a specific focus on a 0.6 cm deep lesion in the right palm. The magnetic field-induced dose...
Authors: Mark W. Geurts, Bridget Ann Melke
Affiliation: Aspirus Health
Abstract Preview: Purpose:
To develop a tool that streamlines and standardizes the process of positioning the SRS MapCHECK detector for intersecting multiple metastases during SRS QA of Single-Isocenter, Multiple Ta...
Authors: Weiliang Du
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Winston-Lutz (WL) tests are often used to localize the radiation isocenter of a linac. The selection of gantry and collimator angles can affect the accuracy of the resulting isocenter. The ef...
Authors: Gueorgui Gueorguiev, Kavya Thaniyarasu
Affiliation: University of Bologna, National Centre of Radiobiology and Radiation Protection
Abstract Preview: Purpose: This study investigates the clinical viability of double scattering proton therapy treatment planning for thoracic malignancies using single or multiple treatment fields. The aim of this stud...
Authors: Hyejoo Kang, Andrew Keeler, Mathias Lehmann, Jason Patrick Luce, Ha Nguyen, John C. Roeske
Affiliation: Varian Imaging Laboratory, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago
Abstract Preview: Purpose: Markerless tumor tracking (MTT) using dual-energy (DE) subtraction imaging is being considered as a non-invasive method to track tumors during lung cancer treatment. Prior to clinical impleme...
Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University
Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...
Authors: Shixiong Huang, Daming Li
Affiliation: The Affiliated Nanhua Hospital, University of South China, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital
Abstract Preview: Purpose: To assess the feasibility of using target current pulse signals to evaluate the output dose of medical standing wave electronic linear accelerators.
Methods: The Target I signal of the acc...
Authors: Yijian Cao, Sean T Grace, Marissa Joyce Vaccarelli
Affiliation: Northwell
Abstract Preview: Purpose:
This study investigates the dosimetric efficacy of significantly limiting gantry angles in prostate radiation therapy to as a promising strategy to maintain plan quality while enhancing ma...
Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels
Affiliation: Varian Medical Systems
Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...
Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag
Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University
Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...
Authors: Hongyu Jiang
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: This study presents a method for transforming coordinates from RayStation’s treatment planning system into the Monte Carlo (MC) coordinate system used in GEANT4 for dose calculations in spot ...
Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang
Affiliation: RefleXion Medical
Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...
Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.
Methods: A commercial rotational table (CDR Equilibrium®) is r...
Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...