4D Monte Carlo Dose Evaluation for Mobile Targets in a Magnetic Field

Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun

Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...

60RPM Rotational Winston Lutz Test to Characterize Operational MV-Kv Offset on Reflexion X1 System

Authors: Huixiao Chen, Ethan Hartowicz, Lichung Ku, Tim Perez, Ray Yang

Affiliation: Salem Health, RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To characterize MV-kV isocenter offset on a novel ring gantry radiotherapy system where the Linac, PET, kV-CT, and MV imaging subsystems rotate together at native operating speed of 60RPM.

An Analytical Framework to Quantify the Effect Obstructing Anatomical Features in Intrafractional Spectral Imaging Using a Dual-Layer Kv Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory

Abstract Preview: Purpose:
Dual-layer kV imager (DLI) architecture enables the capability for single-shot dual-energy (DE) intrafraction imaging. As noise from individual DLI layers are primarily uncorrelated, simpl...

An Assessment of the Potential Impact of the Elekta Unity’s 1.5T Magnetic Field upon the Performance of a Conventional Linac Installed in an Adjacent Vault: A Case Study

Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang

Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health

Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...

Breastplan-Helper: Publicly Shared Source Scripting Toolset to Assist in 3D Breast Planning

Authors: Ryan Clark, Anthony Magliari, Luis Felipe Oliveira E Silva, Yang Sheng, Jason R Vickress, Qingrong Jackie Wu, Giulianne Rivelli Rodrigues Zaratim

Affiliation: Verspeeten Family Cancer Center, Office of Medical Affairs, Varian, A Siemens Healthineers Company, Confiar Radioterapia, Duke University Medical Center

Abstract Preview: Purpose: Develop a toolset to replace several of the tedious steps required to manually generate 3D breast treatment plans using static gantry forward planned tangent beams.

Methods: Eclipse Sc...

Characterization of a Novel Large-Sized Epid System from the Newly Released Ring Shape Radiation Therapy Halos Tx

Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang

Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment

Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...

Characterizing and Modeling Higher-Order Motions of Collimator Subsystem on a 60RPM Gantry Linac for Improved Small Target Dosimetry

Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Comprehensive Evaluation of High-Performance Cone-Beam Computed Tomography on C-Arm and Ring-Gantry Linacs for Adaptive Radiation Therapy

Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...

Detection of the Linac Jaw Face Angle Misalignment: Case Studies

Authors: Peter Balter, Andres V Cibrian, Song Gao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to demonstrate a means of detecting misaligned jaw face angles on the Varian TrueBeam based on a beam symmetry metric for electron beam profiles.
Methods: Duri...

Determine the Isocenter and Its Size for MR Linac Unity Part1: (U V) of Cax

Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...

Determine the Isocenter and Its Size for MR Linac Unity Part2: (u v) of BB and Isocenter Position and Size

Authors: Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
This study, the second in a two-part series, evaluates the isocenter position (the point in 3D space minimizing the sum of Euclidean distances to the MLC's central axis) and isocenter size...

Diffusion-Based PET Image Enhancement in Bgrt

Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie

Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The RefleXion® X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...

Evaluating the Aktina Isopoint System for Quality Assurance in Linear Accelerators

Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...

Evaluation of Plan Quality and Optimal Isocenter Arrangement for Total Marrow and Lymphoid Irradiation on a Ring-Gantry Linac with Dual-Layer Mlc Using the Knowledge-Based Planning Technique

Authors: Chunhui Han, An Liu, Anthony Magliari, Lesley Rosa

Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the performance of a knowledge-based planning (KBP) optimization model for total marrow and lymphoid irradiation (TMLI) on a ring-gantry linac with a dual-layer MLC and to evaluat...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

Film-Based Method for Accurate Radiation Isocenter Determination in Linear Accelerators Using 3D Starshot

Authors: Robert A. Corns, Mohammad Kanber

Affiliation: East Carolina University, East Carolina University Brody School of Medicine

Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...

Frameless and Maskless Stereotactic Radiosurgery: Evaluating a Novel Robotic Head Motion Compensation Device

Authors: Michelle Alonso-Basanta, Carl Denis, Wenbo Gu, Xinmin Liu, Ahmad Sakaamini, Rodney D. Wiersma

Affiliation: UCLA, University of Pennsylvania, CDR Systems

Abstract Preview: Purpose: Stereotactic radiosurgery (SRS) is a non-invasive technique used to treat functional abnormalities and small brain tumors. Traditional SRS relies on a rigidly fixed metal head ring, causing d...

Investigating the Dosimetric Benefits of Enhanced Solid Angle Accessibility in a Self-Shielded Radiosurgery System

Authors: Peter Jermain, Ying Niu, Abdul Rashid, Yuan Yuan, Mohammad Zarenia

Affiliation: Medstar Georgetown University Hospital, MedStar Georgetown University Hospital, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose: ZAP-X is a self-shielded radiosurgery system that utilizes a linac-based isocentric technique and a compact gyroscopic gantry design. While it provides a large solid angle for beam orientatio...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Multi-Vendor Linac Isocenter Evaluation: Implications for SRS in Radiotherapy

Authors: Blessing Chinelo Akah, Brad Barhorst, Daniel W. Neck, David J. Perrin, Chad Robertson, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To evaluate the performance and radiation isocenter of Elekta and Varian linear accelerator using Aktina Isopoint.
Methods: The Aktina Isopoint was used to measure the physical and radiati...

Objective Verification of Mechanical and Radiation Isocenters Independent of Setup

Authors: Jonathan Dowell, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, Iridesce Solutions, Inc.

Abstract Preview: Purpose: The novel machine quality assurance (QA) device nüFilm (Iridesce Solutions, Lexington KY) allows for an objective assessment of light and radiation fields independent of setup. Herein, the ab...

Optimizing Dose Coverage and Mitigating Electron Return Effects and Electron Stream Effects in MR-Linac Treatment of Extremity Malignancies: The Impact of Bolus and Gel Use

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Darren M. C. Poon, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: This study investigates optimal treatment strategies utilizing MR-linac for extremity lesions, with a specific focus on a 0.6 cm deep lesion in the right palm. The magnetic field-induced dose...

Optimizing the Collimator Angles in Radiation Isocenter Localization Using Winston-Lutz Tests

Authors: Weiliang Du

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Winston-Lutz (WL) tests are often used to localize the radiation isocenter of a linac. The selection of gantry and collimator angles can affect the accuracy of the resulting isocenter. The ef...

Performance Evaluation of End-of-Life Epid Panel Utilizing Automated Quality Assurance Test Suite

Authors: Michael Paul Barnes, Lana C. Critchfield, John J. DeMarco, Ellie Durussel, Nilendu Gupta, James Irrer, Peyton Jensen, Grace Gwe-Ya Kim, Cory S. Knill, Seng Boh Gary Lim, Justin K. Mikell, Jean M. Moran, Seyyedeh Azar Oliaei Motlagh, Mario Perez, Michael Pillainayagam, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Washington University School of Medicine in St. Louis, University of California San Diego, Royal North Shore Hospital, Calvary Mater Hospital Newcastle, Cedars-Sinai Medical Center

Abstract Preview: Purpose: EPIDs are widely used in linac QA due to their efficiency and accuracy. As EPIDs age, performance degradation may occur, potentially compromising reliability of EPID-based automated QA result...

Proposed Method for Optimization of Lattice Radiation Therapy Using an Advanced Ring Gantry Linac

Authors: Eduardo Florian, Osmar Obdulio Hernandez, Otto Hurtarte, Milton Ixquiac, Erick Orlando Montenegro, Franky Eduardo Reyes, Edgar Aparicio Ruiz, Kevin Vega, Vicky de Falla

Affiliation: Liga Nacional Contra el Cancer, Liga Nacional Contra el Cancer/INCAN, Liga Nacional Contra el Cancer / INCAN, Liga Nacional Contra el Cancer and Universidad de San Carlos de Guatemala, Liga Nacional Contra el Cáncer / INCAN

Abstract Preview: Introduccion:
Lattice Radiation Therapy (LRT) is a form of spatially fractionated radiation therapy (SFRT) designed to improve control of large tumors by delivering ablative doses while minimizing ...

Reinforcement Learning Based Machine Parameter Optimization for Two-Arc Prostate VMAT Planning

Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...

Scan Efficiency and Imaging Dose Analysis of Next-Generation Nonstop Gated CBCT for Respiratory Gating Lung Radiotherapy

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...

Significantly Limiting Posterior Gantry Angles in Prostate VMAT Optimization: A Dosimetric Assessment of Plan Quality

Authors: Yijian Cao, Sean T Grace, Marissa Joyce Vaccarelli

Affiliation: Northwell

Abstract Preview: Purpose:
This study investigates the dosimetric efficacy of significantly limiting gantry angles in prostate radiation therapy to as a promising strategy to maintain plan quality while enhancing ma...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

To Assess and Monitor the Characteristics of Scanning Proton Beam Utilizing the Xrv-124 Scintillator Device

Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag

Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University

Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...

Treatment Dose Reconstruction of Digitized Deliveries on Reflexion X1 System Based on Megavoltage Imager and Dose Monitor Chamber

Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...

Treatment Plan Comparisons of Head and Neck Cancers on Varian Ethos/Halcyon and Truebeam Linac

Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...