Search Submissions ๐Ÿ”Ž

Results for "gaze gated": 15 found

A Two-Layer, Two-Task Prediction Model Based on 3D Imaging and Residual Networks for Mid-Chemoradiation Tumor Response Prediction on FDG PET for La-NSCLC

Authors: Stephen R. Bowen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Jing Sun, Jiajie Wang, Shouyi Wang, Faisal Yaseen, Xiaojing Zhu

Affiliation: Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Shanghai University of Electric Power, Fred Hutchinson Cancer Center, University of Texas at Arlington

Abstract Preview: Purpose: Accurate prediction of patient response to radiotherapy plays a crucial role in monitoring disease progression and assessing treatment efficacy, enabling clinicians to develop personalized th...

An Alpha Irradiation System for Radiobiological Studies with Versatile Dose Rate Control

Authors: Harsh Arya, Yan Chang, Yujie Chi, Varghese Anto Chirayath, Joshua Rajan, Pan Zui

Affiliation: University of Texas at Arlington, Department of Physics, University of Texas at Arlington

Abstract Preview: Purpose: In targeted alpha therapy (TAT), absorbed dose rates can vary significantly spatially and temporally, impacting therapeutic efficacy as well as carcinogenic potential. This study reports the ...

Auto-Beam Hold Validation for Varian Sgrt Identify 3.0 on Truebeam Linear Accelerators

Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...

Comparative Evaluation of Spekpy for Kilovoltage Beam Quality Characterization

Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park

Affiliation: Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...

Feasibility Study on Creating a Digital Twin of Digital Subtraction Angiography Data Utilizing Monte Carlo and Computational Fluid Dynamic Simulations

Authors: Ciprian N. Ionita, Parisa Naghdi, Ahmad Rahmatpour

Affiliation: University at Buffalo, SUNY: University at Buffalo

Abstract Preview: Purpose: Quantitative angiography (QA) evaluates neurovascular hemodynamics, but is affected by X-ray parameters, vessel foreshortening, and imaging chain factors like detector efficiency, pixel size,...

Impact of Breathing Trace on Gating Uncertainty

Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.

Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...

In-Vivo Dosimetry in Positron-Guided Radiation Therapy

Authors: Davide Brivio, Erno Sajo, Ryan Williams, Piotr Zygmanski

Affiliation: University of Massachusetts Lowell, Brigham and Women's Hospital, Department of Radiation Oncology, Brigham and Womenโ€™s Hospital, Dana-Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: To develop a non-invasive 3D in-vivo dosimetry tool exploring the relationship between positron annihilations and dose per voxel using Monte Carlo simulation. The Positron Guided Radiation Th...

Innovative Design and Simulation of a Pediatric-Dedicated SPECT: Enhancing Imaging Performance for a Healthier Scans in Children

Authors: Mohammadreza Ay, Nahal Daneshgar, Nima Kasraie, Abbas Monsef, Zeinab Peymani, Hadi Rezaei, Peyman Sheikhzadeh

Affiliation: University of Minnesota Medical School, Radiation Oncology, Department of Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Shiraz University of Medical Sciences, Department of Medical Physics, Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, UT Southwestern Medical Center, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences

Abstract Preview: Purpose:
This study aims to design and simulate an innovative pediatric-dedicated SPECT scanner optimized for childrenโ€™s unique anatomical and safety needs by enhancing sensitivity in data acquisit...

Integrating Large Kernel Attention Mechanism into Deep Learning Model for Automatic and Auccrate Segmentation of Gross Tumor Volume in Lung Cancer Patients

Authors: Xuezhen Feng, Li-Sheng Geng, Haoze Li, Xi Liu, Tianyu Xiong, Ruijie Yang

Affiliation: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, School of Physics, Beihang University, School of Nuclear Science and Technology, University of South China, Department of Radiation Oncology, Peking University Third Hospital

Abstract Preview: Purpose: This study aimed to develop a deep learning-based algorithm for automatically delineate gross tumor volume (GTV) for lung cancer patients, alleviating the workload of radiologists and improvi...

Optimizing Design to Enhance the Energy Separation in a Kv Dual-Layer Imager (DLI)

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Womenโ€™s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Multi-layer flat-panel imagers can improve for clinical image-guided radiotherapy applications, including the enhanced visualization of soft tissue and a reduction in image artifacts. Each im...

Preclinical Assessment of 68ga-Dotatate As a Surrogate for 177lu-Dotatate Dose Distribution in Radionuclide Therapy

Authors: Payman Hejazi, Faraz Kalantari, Milad Peer-Firozjaei, Romina Pourhashem, Ehsan Tajikmansoury

Affiliation: Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Medical Physics, Semnan University of Medical Sciences, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose:
Pretreatment biodistribution imaging play a crucial role in optimizing tumors and organ absorbed doses estimation in radionuclide therapy. Surrogating radionuclides for more efficient trea...

Preliminary Evaluation of a Gpฯ„-Based Medical Physics Education Tool

Authors: Ramesh Boggula, Jay W. Burmeister, Michael Joiner

Affiliation: Wayne State University, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine

Abstract Preview: Purpose: Recent advances in large language models such as ChatGPT offer new possibilities for supplementing traditional teaching methods. In this study, we developed a custom GPT-powered tool freely a...

Retrospective Analysis of Treatment Pauses Due to Intrafraction Movement for Frameless Single Fraction Gamma Knife Icon Radiosurgery

Authors: Nina Burbure, Tawfik G. Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital

Abstract Preview: Purpose: Frameless gamma knife (GK) treatments use a thermoplastic mask coupled with high-definition motion management system that utilizes an infrared camera, and a reflective marker placed on the pa...

Scissor-Beam Based Carbon Ion Minibeam Treatment Planning Method

Authors: Hao Gao, Qiang Li, Yuting Lin, Wei Wang, Wei Wu, Weijie Zhang

Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, China, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Carbon minibeam radiation therapy (cMBRT) offers high peak-to-valley dose ratio (PVDR) and relative biological effectiveness. A key challenge is balancing uniform target coverage with PVDR pr...

Spot Scanning Gantry-Based Gaze-Gated Ocular Proton Treatment Planning at Mayo Clinic Rochester

Authors: Amanda J. Deisher, Susannah V. Hickling, Shima Ito, Jon J. Kruse

Affiliation: CancerCare Manitoba, Mayo Clinic

Abstract Preview: Purpose:
To date, 11 ocular patients were treated with spot scanning gantry-based gaze-gated ocular proton program at Mayo Clinic, Rochester MN since 2023. Treatments are done in the half-arc gantr...