A Hybrid Transformer-CNN for Tracking-Free 3D Ultrasound Volume Reconstruction from 2D Freehand Scans

Authors: Wenfeng He, Tian Liu, Pretesh Patel, Richard L.J. Qiu, Keyur Shah, Tonghe Wang, Xiaofeng Yang, Chulong Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Emory University, Medical Physics Graduate Program, Duke Kunshan University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: This study introduces a tracking-free approach to reconstruct 3D ultrasound (US) volumes from 2D freehand US scans. By eliminating the reliance on external tracking systems, this method aims ...

A Mechatronic Biopsy Guidance System for an Integrated 3D TRUS with Prostate-Specific PET System

Authors: Jeffrey Bax, Ian A. Cunningham, Aaron Fenster, Lori Gardi, Sule Karagulleoglu Kunduraci, Alla Reznik, David Tessier

Affiliation: Robarts Research Institute, Imaging Research Laboratories, Robarts Research Institute, Lakehead University

Abstract Preview: Purpose: Image-guided biopsy is critical for early diagnosis of prostate cancer (PCa), the most common cancer in men worldwide. While the prostate-specific PET (P-PET) system offers enhanced sensitivi...

Advanced Modeling of Singlet Oxygen Distribution in Pleural Cavity Photodynamic Therapy Using Validated Geometric Standardization

Authors: Hongjing Sun, Timothy C. Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to develop a model of singlet oxygen distribution in pleural photodynamic therapy (PDT) by combining standardized anatomical coordinates with CT-validated geometry reconstruct...

An International Survey of High Dose Rate Brachytherapy Dosimetry Practices

Authors: Anna Becker, Tomislav Bokulic, Mauro Carrara, Krzysztof Chelminski, Larry A. DeWerd, Alexis Dimitriadis, Benjamin Kellogg, Malcolm R. McEwen, Zakithi L.M Msimang, Mark J. Rivard, Thorsten Sander, Thorsten Schneider, Jamema Swamidas, Egor Titovich, Paula Toroi, Carlos E. de Almeida, Jacco de Pooter, Liset de la Fuente Rosales, Deborah G. van der Merwe

Affiliation: Radiation and Nuclear Safety Authority, University of Zagreb, National Physical Laboratory, IAEA, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Rio de Janeiro State University, Dosimetry Laboratory, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, Physikalisch-Technische Bundesanstalt, National Metrology Institute, University of the Witwatersrand, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, National Research Council, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: The recently published IAEA-TRS-492 international code of practice (CoP) aims at improving traceability, accuracy, and consistency in Brachytherapy Dosimetry. To assess current approaches to ...

Assessment of Practice Consistency for Management of Target Exposure Indices in Digital Radiography

Authors: Zachary Carr, Katie W. Hulme, Zaiyang Long, Nathan A. Quails, Ashley Tao

Affiliation: Gundersen Health System, Ohio State University Wexner Medical Center, Mayo Clinic, Ohio State Wexner Medical Center, The Cleveland Clinic

Abstract Preview: Purpose: Meaningful interpretation of deviation index (DI) in clinical practice relies on appropriately set target exposure indices (EIT). EIT values for a given exam-view can be derived from the medi...

Can We Use Smaller Margin for the Planned Target Volume with Adaptive Radiotherapy?

Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center

Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...

Commissioning a Comprehensive Workflow for VMAT Total Body Irradiation (TBI) Using Publicly and Commercially Available Resources

Authors: Alan H. Baydush, Sarah Cummings, Jeffrey Michael Fenoli, Christy Hickerson, Lalith Kumaraswamy, Philmo Oh, Sarah B. Wisnoskie

Affiliation: Novant Health Cancer Institute, Novant Health

Abstract Preview: Purpose: To develop, validate, and commission a VMAT Total Body Irradiation (TBI) workflow by integrating publicly available resources, commercial solutions, and in-house testing to enhance treatment ...

Comparison of Multispectral Singlet Oxygen Luminescent Dosimetry (MSOLD) and Singlet Oxygen Explicit Dosimetry (SOED) in BPD-Mediated PDT for Mice

Authors: Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Vikas Vikas, Brian C. Wilson, Weibing Yang, Timothy C. Zhu

Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania

Abstract Preview: Purpose:
Multispectral Singlet Oxygen Luminescent Dosimetry (MSOLD) has been developed as a real-time in vivo dosimetry technique for Photodynamic Therapy (PDT). This study investigates the feasibi...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Development of Treatment Planning System for Carbon Ion Radiotherapy in Yonsei Cancer Center

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojin Kim, Jin Sung Kim, HO Lee, Sac Lee, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) offers the advantage of a greater relative biological effectiveness (RBE) weighted dose, which must be integrated into the treatment planning system (TPS). This...

Development of a Robust 3D-Ultrasound (3DUS) Quality Assurance (QA) Framework for a Real-Time Needle-Tracking System in HDR GYN Brachytherapy

Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity

Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...

Development of an MRI Guided Precision Small Animal Radiotherapy System

Authors: Yaowen Cao, Yunwen Huang, Yidong Yang, Xiaogang Yuan, Ning Zhao, Cheng Zheng

Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: MRI has better soft tissue contrast than cone beam CT which is commonly used in image guided radiotherapy. This study aims to develop a low-field MRI system for precision small animal radiati...

EBT4 Film Dosimetry and the Significance of the ¼ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Evaluation of Color Display Performance of Pathology Relevant Colors Using the Macbeth Colorchecker

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Display image accuracy is critical for digital diagnostic fields, such as radiology and digital pathology. While the AAPM TG-18 test patterns are established for grayscale radiology monitor Q...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexion™ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXion® X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Iguard: A Fully Unsupervised Image-Guidance Anomaly Recognition and Detection Framework in CBCT-Guided Radiotherapy.

Authors: James M. Lamb, Dishane Chand Luximon, Jack Neylon, Rachel Petragallo, Moritz Ritter, Timothy Ritter

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, ETH Zurich, VCU Health System, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: Anomalies in cone beam computed tomography (CBCT) radiotherapy image guidance can signal treatment deviations. Repetitive review of setup image registrations by humans is inefficient, prone t...

Image Guidance for Mitigating the Impact of Table Walkout on Delivered Dose in Non-Coplanar Stereotactic Radiotherapy

Authors: William E Burrell, Philip F. Durham, Anne N Hubbard, Yohan Akeakamai Walter, Hsinshun Terry Wu

Affiliation: Willis Knighton Cancer Center

Abstract Preview: Purpose: Linear accelerator (LINAC)-based single-isocenter, multi-target (SIMT) treatment has streamlined the stereotactic radiosurgery (SRS) workflow. However, off-isocenter treatment carries multipl...

Impact of Feraheme on Imaging and Thermal Dynamics during MR-Guided Focused Ultrasound: Phantom Study

Authors: Jaydev K. Dave, Krzysztof R Gorny, Chunming Gu, Nicholas J. Hangiandreou, Gina K. Hesley, Myung-Ho In, Zaiyang Long, Aiming Lu, Christin A. TiegsHeiden

Affiliation: Mayo Clinic

Abstract Preview: Purpose:
MR-guided focused ultrasound (MRgFUS) enables precise tumor ablation with real-time MR-thermometry guidance. Our practice is exploring the potential use of Feraheme (Ferumoxytol), a superp...

Incorporating Cyclic Group Equivariance into Deep Learning for Reliable Reconstruction of Rotationally Symmetric Tomography Systems

Authors: Fang-Fang Yin, Lei Zhang, Yaogong Zhang

Affiliation: Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Rotational symmetry is an inherent property of many tomography systems (e.g., CT, PET, SPECT), arising from the circular arrangement or rotation of detectors. This study revisits the image re...

Integrated Catheter Position and Dwell Time Optimization for Focal Dose Escalation in Prostate HDR Brachytherapy

Authors: Bryan Bednarz, John M. Floberg, Joseph B. Schulz, Jordan M. Slagowski

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Catheter placement for high-dose-rate brachytherapy (HDR BT) is clinician dependent and potentially suboptimal for delivering simultaneous integrated boosts to intraprostatic gross tumor volu...

Mask-Less Adaptable Headrest for Head-and-Neck Radiotherapy

Authors: Alyssa Capizzi, John J Dombrowski, Nabil N. Khater

Affiliation: Saint Louis University

Abstract Preview: Purpose: To evaluate a mask-less adaptable headrest (MAHR) prototype for head-and-neck IMRT designed to reduce random and systematic shifts of patients’ setups. MAHR complements current image-guidance...

Novel 3D Imaging Systems for Surgical Guidance : Loop-X and Nview S1 in Comparison with O-Arm

Authors: Jia Wang, Vani Yadav

Affiliation: Stanford University

Abstract Preview: Purpose: To evaluate the radiation dose and imaging quality of two novel CBCT X-Ray imaging systems used in spine surgeries.
Methods: CBCT scan of ACR CT and CTDI phantoms was performed to acquire ...

PCA-Based Future Frame Prediction for Real-Time MRI-Guided Radiotherapy

Authors: B. Gino Fallone, Gawon Han, Keith D. Wachowicz, Mark G. Wright, Eugene Yip, Jihyun Yun

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com

Abstract Preview: Purpose: MRI-radiotherapy hybrid systems can guide the therapeutic beam, dynamically adjusting to a moving tumor in real-time. However, there is a time delay from imaging and beam control, requiring p...

Patient-Specific Deep Reinforcement Learning Framework for Automatic Replanning in Proton Therapy for Head-and-Neck Cancer

Authors: Malvern Madondo, Mark McDonald, Zhen Tian, Christopher Valdes, Ralph Weichselbaum, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Emory University, Department of Radiology, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Head-and-neck (HN) cancer patients often experience significant anatomical changes during treatment course. Proton therapy, particularly intensity-modulated proton therapy (IMPT), is sensitiv...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Python-Based Patient Coaching System for Gated Treatment Delivery

Authors: Usha Robins Abraham, Monique Lockhart Chisem, Alonso N. Gutierrez, Janos Juhasz, Michael Leyva, Carlos M. Rivera, Ranjini P. Tolakanahalli, Vanessa Vega Fleites

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health

Abstract Preview: Purpose:
Accurate breath hold (BH) gated treatments rely heavily on patient cooperation. Maintaining consistent breath-hold levels can be challenging for patients. Surface image guidance (SGRT) is ...

Quantitative Fluorescence Molecular Tomography Guide Radiation Therapy

Authors: Jiahao Chen, Yunwen Huang, Yidong Yang, Shanshan Zhang, Ning Zhao, Cheng Zheng

Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop a molecular image-guided radiotherapy technique for accurate and effective radiation treatment using quantitative fluorescence molecular tomography (FMT).
Methods: X-ray cone be...

“See” through Surface: Transforming Surface Imaging into a Real-Time Three-Dimensional Imaging Solution for Intra-Treatment Image Guidance

Authors: Steve B. Jiang, Ruiqi Li, Hua-Chieh Shao, Kenneth Westover, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Respiratory motion is a long-standing challenge for lung SBRT, particularly for centrally-located lung tumors where increased toxicity demands more precise motion management during treatme...