Search Submissions 🔎

Results for "guided bgrt": 51 found

4D CBCT Reconstruction Using Denoising Diffusion Implicit Models

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Bohong Huang, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) is critical in image-guided radiotherapy (IGRT) for visualizing tumor motion. However, sparse projection sampling often introduces sev...

A Comparative Analysis of the Dosimetric, Alignment, and Setup Efficiency in Left Breast Cancer Radiotherapy Treated with Dibh Using ABC and Sgrt

Authors: Aaron Conard, Victoria Croog, Marie Gurka, Lan Lin

Affiliation: Johns Hopkins University

Abstract Preview: Purpose:
This study evaluates the utility of the Active Breathing Coordinator (ABC) and Surface Guided Radiation Therapy (SGRT) techniques in implementing Deep Inspiration Breath Hold (DIBH) for le...

A Patient-Specific Approach to Surface Guided-DIBH SBRT Candidacy Using Surface Deformation Maps

Authors: Savannah Decker, Grace Gwe-Ya Kim, Laura Padilla

Affiliation: UC San Diego, University of California San Diego

Abstract Preview: Purpose: The success of surface-guided deep-inspiration breath-hold (SG-DIBH) treatments depends on accurate identification of suitable candidates. Sub-optimal patient selection can result in prolonge...

A Real-Time 6 Degrees-of-Freedom Image Guided Radiation Therapy Technology Using Internal-External Motion Correlation Modelling

Authors: Jeremy T. Booth, Nicholas Hardcastle, Freeman Jin, Alicja Kaczynska, Paul J. Keall, Chandrima Sengupta

Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, Physical Sciences, Peter MacCallum Cancer Centre, Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: An ESTRO survey reported that 71% of radiotherapy centers across 41 countries want to implement real-time image guided radiation therapy (IGRT) to improve patient outcomes. To address this gl...

A Simple and Reliable Method to Determine Patients Eligible for Treatment on the Novel Biological Guided Radiotherapy (BgRT) System Based on FDG Uptake in Nearby Non-Treatment Regions.

Authors: Brett Lewis, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose: The novel RefleXion SCINTIX BgRT system relies on the FDG uptake distribution from a PET study to plan and deliver dose. One of the patient eligibility criteria is that any uptake outside the...

A Tumor Tracking Method in Surface-Guided Radiotherapy

Authors: Penghao Gao, Zejun Jiang

Affiliation: Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: Real-time tumor tracking can effectively compensate for the impact of respiratory motion on dose distribution. We propose a patient-specific external-internal correlation model driven by opti...

An Automated Notification System for Identifying Patients Eligible for Biology-Guided Radiotherapy

Authors: Shahed Badiyan, Bin Cai, Tu Dan, Michael Dohopolski, Steve B. Jiang, Deepkumar Mistry, Arnold Pompos, Robert Timmerman, Jing Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Biology-guided radiotherapy (BGRT) offers significant potential for personalized and adaptive cancer treatment, with clinically available systems such as SCINTIX from Reflexion now being intr...

Analysis of the Accuracy of Avatar-Based Patient Positioning Technique for Radiation Therapy

Authors: Danna Gurari, Moyed Miften, Sarah Milgrom, Atharva Rajesh Peshkar, Willem Schreuder, David H. Thomas

Affiliation: University of Colorado Boulder, University of Colorado School of Medicine, University of Colorado Anschutz, Thomas Jefferson University

Abstract Preview: Purpose: To evaluate the accuracy of a novel avatar-based patient positioning technique.

Methods: We developed a modified surface-guided radiation therapy (SGRT) technique, 'Avatar-Guided Radia...

Assessment of the Auto Registration Feature of the PET/CT Linac Used for Biology Guided Radiation Therapy (BGRT)

Authors: Emily Hansen, Tyler Kaulfers, Alois M. Ndlovu, Francia Romero, Niara Rowe, Roland Teboh

Affiliation: Montefiore Einstein University Hospital, Hackensack University Medical Center

Abstract Preview: Purpose: Daily use and reliance on the auto registration feature requires a performance check. Clinical application of auto registration is performed without a selected region of interest (ROI), requi...

Auto-Beam Hold Validation for Varian Sgrt Identify 3.0 on Truebeam Linear Accelerators

Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...

Automation of Daily, Monthly, and Annual Image Quality Controls of Image-Guided Radiotherapy (IGRT) Systems

Authors: Alvaro Daniel Cruz Cortes, Robin Enric Lopez Fonseca, Valeria Pérez Martínez

Affiliation: National Autonomous University of Mexico (UNAM), Faculty of Sciences, Biomedical Physics Program, National Autonomous University of Mexico (UNAM), Faculty of Sciences, National Autonomous University of Mexico (UNAM), Faculty of Sciences, Physics Program

Abstract Preview: Purpose: Automate and evaluate daily, monthly, and annual QC of IGRT systems, following the AAPM TG-198 protocol, through the development of a graphical user interface that enables efficient analysis ...

Bgrt Patient Eligibility Check Via Comparing User Defined Ring Around the Biologically Tracking Zone (BTZ) in PET Images

Authors: Resat Aydin, Brett Lewis, Jayesh Mistry, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose:
We developed a Python-based solution to systematically quantify and detect fluorodeoxyglucose (FDG) uptake beyond a predefined Biologically Tracking Zone (BTZ) in PET images. This method i...

Clinical Application of Biology-Guided Radiotherapy (BgRT) to Patient Having a Cardiac Implantable Electronic Device (CIED)

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Yesenia Gonzalez, Zohaib Iqbal, Paul M. Medin, Rameshwar Prasad, Chenyang Shen, Robert Timmerman, Yuanyuan Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Each year more than one million pacemakers and 200k cardioverter-defibrillators are implanted in patients worldwide. The presence of a CIED introduces challenges to the delivery of radiation ...

Confidence in a Tattoo-Less Transition

Authors: Laura A. Doyle, Amy S. Harrison, Allyson P Koecher, Jackson D Reeves, Lindsay B Romak

Affiliation: Christiana Care

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) is increasingly utilized in radiation oncology, allowing for transition away from permanent skin marks to SGRT-based daily treatment setup. Following i...

Contingency Planning for Left-Sided Breast Radiation Treatment Using Breath-Hold Technique with Different Delivery Methods

Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...

Creation of Customized Workflows in a New Surface-Guided Radiation Therapy (SGRT) System

Authors: Sorour Hosseini, YuHuei Jessica Huang, Jeremy Kunz, Nicholas Pierre Nelson, Ryan G. Price, Prema Rassiah, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To investigate the feasibility and clinical implications of creating customized workflows in a new SGRT system: LUNA 3D (LAP, Florida).
Methods: Three clinical SGRT workflows were designed...

Determination of Optimal Surface Rois for Sgrt-Guided Dibh Treatment of Abdominal Cancer

Authors: Megan E. Daly, Ajay Fernandez, Ryan D. Hernandez, Soo Kyoung Kim, Arta Monjazeb, Minahal Naveed, Peter C. Park, Jotsna Singh, Payton H. Stone

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To identify optimal deep-inspiration breath-hold (DIBH) surface-guided radiotherapy (SGRT) regions of interest (ROIs) for abdominal stereotactic body radiation therapy (SBRT) treatments.
M...

Developing and Evaluating the First Pre-Treatment Physics Plan Checklist for Error Detection in Biology-Guided Radiotherapy (BgRT)

Authors: Michael Burke, David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Vanessa Hill, Ann-Teresa Jasman, John Kim, Svetlana Kuznetsova, MinYoung Lee, Daniel Longo, Henry S. Park, Adam Shulman, Lauren Tressel, Weili Zhong

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The complexity of biology-guided radiotherapy (BgRT), particularly with systems like RefleXion X1, necessitates robust pre-treatment quality assurance (QA) to ensure patient safety, treatm...

Developments of a Low-Cost Multi-Target Winston-Lutz Phantom and Software for SRS Linac Machines

Authors: Nellie Brovold, Wenbo Gu, Huan Amanda Liu, Lin Ma

Affiliation: University of Pennsylvania, Mayo Clinic

Abstract Preview: Purpose: To develop a low-cost comprehensive QA phantom and software for single-iso multi-target SRS Linac machines. This phantom can perform 1) Winston-Lutz QA test for on-axis and off-axis targets, ...

Diffusion-Based PET Image Enhancement in Bgrt

Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie

Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The RefleXion® X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...

Dosimetry Comparison of Surface-Guided and Orthogonal X-Ray Film-Based Setups for Proton Pencil-Beam Scanning in Breast Cancer Treatment

Authors: Darren Kaplan, Chenguang Liu, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center

Abstract Preview: Purpose: This study evaluates the hypothesis that surface-guided radiation therapy for the breast or chest wall using proton PBS provides comparable target coverage and OARs sparing to x-ray-based IGR...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Establishing Tumor Size-Dependent Contrast Requirements for Multi-Target Biology-Guided Radiation Therapy (BgRT)

Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu

Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To determine minimum target size and FDG contrast thresholds for reliable Biology-guided Radiation Therapy (BgRT) delivery using a systematic phantom study.
Methods: A custom 3D-printed ph...

Evaluating PET-Based Metrics to Identify Patients with Liver Metastases for Biology-Guided Radiotherapy

Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue

Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...

Evaluating Planning Metrics for Biology-Guided Radiation Therapy (BgRT)

Authors: Emily Hansen, Jay Mistry, Alois M. Ndlovu, Niara Rowe, Roland Teboh

Affiliation: Hackensack University Medical Center

Abstract Preview: Purpose: SCINTIX Biology-guided radiotherapy (BgRT) on the RefleXion X1 relies on a new planning system and advanced planning techniques. The first patient SCINTIX BgRT plans are compared to similar c...

Evaluating the Role of Surface-Guided Radiotherapy in Prone Breast Cancer Treatment

Authors: Shifeng Chen, Mariana Guerrero, Michael J. MacFarlane, Huijun Xu, Baoshe Zhang, Jinghao Zhou

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center

Abstract Preview: Purpose: The clinical value of surface-guided radiotherapy (SGRT) in prone breast cancer setups is much less established than in supine setups. This study explores SGRT's potential for prone breast pa...

Evaluation of Time Delays in a Surface-Guided Radiotherapy-Based Gating System Using Exactrac Dynamic and Truebeam Linear Accelerator

Authors: Hiroki Katayama, Hiroki Kawasaki, Motonori Kitaoka, Yosuke Takahashi, Takashi Tanii, Masato Tsuzuki

Affiliation: Kagawa University Hospital

Abstract Preview: Purpose:
Surface-guided radiotherapy (SGRT) with ExacTrac Dynamic (ETD) allows motion tracking and beam gating during treatment delivery. Accurate evaluation of beam-on and beam-off delays is essen...

Evaluation of a Commercial Metal Artifact Reduction Algorithm for IGRT in Patients with Hip Prostheses

Authors: Laura Bennett, Matthew Charles, Greg Cooley, John M. Floberg, Ryan Hutten, Elissa Khoudary, Nicholas Lynch, Kaili Ranta, Jordan M. Slagowski, Trevor Wilson

Affiliation: University of Pennsylvania, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, University of Wisconsin-Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: To evaluate the impact of an iterative cone beam CT with metal artifact reduction (iCBCT+MAR) reconstruction algorithm (HyperSight TrueBeam 4.1, Varian Medical Systems) on image quality and s...

Evaluation of the Imaging Performance of PET-Linac As Compared to a Diagnostic PET/CT System for Small Tumors

Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu

Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To systematically evaluate the relationship between Activity Concentration (AC) obtained from the RefleXion PET-Linac with the maximum standardized uptake value (SUVmax) derived from a diagno...

Failure Mode and Effects Analysis (FMEA) on Use of Surface Guided Imaging

Authors: Victoria Noelle Bry, Tamara Egan, Eric C. Ford, Angelia Landers, Juergen Meyer

Affiliation: Fred Hutch Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) can improve patient safety, however, its complex integration may expose processes to increased risk of error. This work identifies potential failures f...

Feasibility of Using 68ga-PSMA for Biology-Guided Radiotherapy (BgRT) Treatment

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Neil Desai, Aurelie Garant, Orhan Oz, Elizeva Phillips, Rameshwar Prasad, Chenyang Shen, Robert Timmerman

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: This study reports findings from the first-in-human imaging-only trial evaluating the feasibility of using the novel PET tracer 68Ga-PSMA-11 (Illuccix) to guide external beam radiotherapy on ...

First Phantom Testing of Biology-Guided Radiotherapy for Sequential Integrated Boost Radiotherapy

Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...

High-Fidelity Synthetic CT Generation from CBCT for Dibh Breast Cancer Patients Using Shortest Path Regularization

Authors: Manju Liu, Weiwei Sang, Yanyan Shi, Zhenyu Yang, Fang-Fang Yin, Chulong Zhang, Lihua Zhang, Rihui Zhang

Affiliation: Jiahui International Hospital, Jiahui International Hospital, Radiation Oncology, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: This study aims to transform cone-beam computed tomography (CBCT) images acquired from deep inspiration breath-hold (DIBH) breast cancer patients into high-fidelity synthetic CT (sCT) images....

Impact of Positron Emission Tomography (PET) Image Characteristics on Biology-Guided Radiotherapy (BgRT) Treatment Accuracy

Authors: Angela J Da Silva, Andrew Groll, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: PET-based biology-guided radiotherapy (BgRT) is a radiation therapy technique that uses PET imaging to deliver tracked dose to the tumor in real-time. We characterized the delivery accuracy o...

Improved Setup Accuracy for Dibh Whole Breast Radiotherapy with Surface-Guided Radiation Therapy

Authors: CheukKai Becket Hui, Goldie M. Klein, Yildirim D. Mutaf, Amir Pourmoghaddas

Affiliation: UC Health, Kaiser Permanente

Abstract Preview: Purpose:
In this study, we investigated the effect of SGRT (Align-RT) implementation on patient setup accuracy for DIBH breast radiotherapy treatments.
Methods:
We extracted vertical post-ima...

Improving Adversarial Approaches to Synthetic CT Image Generation with Skin Surface Masks

Authors: Mahya Ahmadzadeh, Nagarajan Kandasamy, Keyur Shah, Gregory C. Sharp, Santhosh Vadivel, John MacLaren Walsh

Affiliation: Electrical and Computer Engineering Department, Massachusetts General Hospital, Emory University, Drexel University

Abstract Preview: Purpose: In image-guided radiotherapy (IGRT), cone beam CTs (CBCTs) suffer from distortions that degrade registration with planning CTs. While CycleGANs can generate synthetic CTs (sCTs) from CBCTs, e...

In-Vivo Dosimetry in Positron-Guided Radiation Therapy

Authors: Davide Brivio, Erno Sajo, Ryan Williams, Piotr Zygmanski

Affiliation: University of Massachusetts Lowell, Brigham and Women's Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: To develop a non-invasive 3D in-vivo dosimetry tool exploring the relationship between positron annihilations and dose per voxel using Monte Carlo simulation. The Positron Guided Radiation Th...

Isocenter Stability after Commissioning of Biology-Guided Radiotherapy (BgRT)

Authors: Emily Hansen, Alois M. Ndlovu, Niara Rowe, Roland Teboh

Affiliation: Hackensack University Medical Center

Abstract Preview: Purpose: The accuracy of SCINTIX biology-guided radiotherapy (BgRT) on the RefleXion X1 is dependent on the correct alignment of the isocenter between all subsystems, including setup lasers, kV imagin...

Next Generation Nanoparticles for Fractionated MRI-Guided Radiation Therapy

Authors: Stephanie Bennett, Ross I. Berbeco, Guillaume Bort, Needa Brown, Lena Carmes, Sandrine Dufort, Michael John Lavelle, Geraldine Le Duc, Francois Lux, Toby Morris, Zeinaf Muradova, Andrea Protti, Olivier Tillement

Affiliation: University de Lyon, NH TherAGuIX, University of Massachsetts Lowell and Dana-Farber Cancer Institute Boston, Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, NH TherAguix, Universite de Lyon, Brigham and Women's Hospital, Dana-Farber Cancer Institute

Abstract Preview: Purpose: AGuIX is a theranostic Gd-based nanoparticle currently under phase-2 clinical testing where patients receive 2-3 doses at 1-week intervals prior to imaging and irradiation. AGuIX-Bi is a new ...

One Year Experience of Biology-Guided Radiotherapy (BgRT) on PET-Linac in an Academic Center

Authors: Shahed Badiyan, Girish Bal, Thomas I. Banks, Bin Cai, Tu Dan, Aurelie Garant, Andrew R. Godley, Steve Jiang, Orhan Oz, Arnold Pompos, Rameshwar Prasad, Chenyang Shen, David Sher, Robert Timmerman, Kenneth Westover

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) is a novel FDA-cleared technology for treating lung and bone tumors based on 18F-FDG PET uptake. This study summarizes the first-year experience treating 29...

Optimizing Low-Dose Imaging Parameters for Dual-Energy Cone-Beam Computed Tomography in Image-Guided Radiation Therapy

Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...

Patient-Specific Bio-Morphological Features in Cherenkov Imaging for Positioning Verification: A Retrospective Analysis in Accelerated Partial Breast Irradiation (aPBI) VMAT Radiotherapy

Authors: Yao Chen, Lesley A Jarvis, Allison Matous, Rongxiao Zhang

Affiliation: Dartmouth College, University of Missouri, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Precise patient positioning is critical in accelerated partial breast irradiation (aPBI) to ensure accurate dose delivery to the tumor bed while minimizing exposure to surrounding healthy tis...

Phantom Assessment for Treating Large Tumors with Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy uses positron emissions from FDG-avid tumor volumes to provide a of the planned prescribed dose with high accuracy. The purpose of this work is to characterize BgR...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≥6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Rapid 3D Prototyped Solid-Source Phantoms for Quality Assurance of Biology-Guided Radiotherapy (BgRT)

Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...

The Biological TCP/NTCP Modelling on Oropharyngeal Head-and-Neck Cancer for Patients Treated with Proton Beam Therapy

Authors: Wen C. Hsi, Tae Kyu Lee, Biniam Yo Tesfamicael

Affiliation: Allina Health, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Oklahoma Proton Center

Abstract Preview: Purpose: When minimal dose-variations induced by inter-fractional anatomical-changes and positioning-deviation were found for having limited impact on clinic-outcomes of oropharyngeal head-and-neck (H...

Towards Optimal Target Dose Conformity and Dose Drop-Off: Evaluation of a New Optimization Approach for Biology-Guided Radiotherapy Treatment Planning

Authors: Grant Gibbard, Chunhui Han, An Liu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...

Tumor Density on Time-Weighted Mid-Position Images for Thoracic Tumors

Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...

Ultra-Sparse-View Cone-Beam CT Reconstruction Based Strictly-Structure-Preserved Deep Neural Network in Image-Guided Radiation Therapy

Authors: Guangjun Li, Ying Song, Huanan Tang, Tianxiong Wu, Qiuyi Ye, Wei Zhang

Affiliation: West China Second Hospital of Sichuan University, United Imaging Healthcare, West China Hospital of Sichuan University

Abstract Preview: Purpose:
To propose a general low-dose reconstruction model for ultra-sparse-view cone-beam CT (CBCT) and evaluate its clinical application in improving image quality and reducing radiation dose fo...

Unlocking Adaptive Radiotherapy Flexibility: Integrating Ethos Adaptive Therapy and Halcyon IGRT with Scripting Innovations

Authors: Min Geon Choi, Sean J. Domal, Ruiqi Li, Taoran Li, Mu-Han Lin, Yang Kyun Park, David D.M. Parsons, Justin D. Visak

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, University of Pennsylvania, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Ethos X-ray-guided online adaptive radiotherapy (ART) enables precise, daily adaptive treatments but requires significant resources, limiting widespread adoption. Many treatment sites do not ...

Use of Radiopaque Rectal Spacer for IGRT – a Preliminary Analysis of Alignment Accuracy and Interobserver Variability

Authors: Joseph A. Miccio, Nicholas J. Potter, Zain Siddiqui

Affiliation: Penn State Health Milton S. Hershey Medical Center

Abstract Preview: Purpose: Fiducial markers are the gold standard for prostate alignment during CT-based image-guided radiotherapy (IGRT). Radiopaque hydrogel rectal spacers reduce rectal toxicity by displacing the rec...