Authors: Rani Anne', Wenchao Cao, Yingxuan Chen, Wookjin Choi, Firas Mourtada, Yevgeniy Vinogradskiy
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: In-room mobile cone-beam CT (CBCT) is emerging to enhance high-dose-rate (HDR) brachytherapy workflow using on-demand imaging. However, metal artifacts from X-ray markers inside gynecological...
Authors: Indrin J. Chetty, Jing Cui, Mitchell Kamrava, Tiffany M. Phillips, Jennifer M. Steers, Brad Stiehl
Affiliation: Department of Radiation Oncology,Cedars-Sinai Medical Center, Cedars-Sinai Medical Center
Abstract Preview: Purpose: Auto-contouring for HDR interstitial brachytherapy can be confounded by large deformation in anatomy and image quality. Here we evaluated the performance of an AI-based auto-contouring softwa...
Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison
Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...
Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology
Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...
Authors: Michael Kudla, Stephanie Merkl
Affiliation: BC Cancer - Kelowna
Abstract Preview: Purpose: 3D modeling for 3D printed GYN high dose rate (HDR) brachytherapy templates can be a time-consuming, error-prone process. To simplify the creation these templates, a software application has ...
Authors: Jonathan J. Chen, Alexei V. Chvetsov, Yulun He, Ramesh Rengan, Andrew Stacey, Kent Wallner
Affiliation: University of Washington and Fred Hutchinson Cancer Center, University of Washington
Abstract Preview: Purpose: To show that the RBE of low-energy photon sources used in COMS (Collaborative Ocular Melanoma Study) eye plaques compensates for protracted irradiation and attenuation of low-energy photons i...
Authors: Brett Bocian, Patrick James Jensen, Luis Augusto Perles, Christopher J. Tien
Affiliation: Yale University School of Medicine, University of Miami, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center
Abstract Preview: Purpose: Guidelines for dose prescriptions in endometrial cancer are based upon depth from the cylinder, traditionally 5 mm or 0 mm (i.e., surface). There are no current single-channel vaginal cylinde...
Authors: Chase Cochran, Damodar Pokhrel, William St Clair
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: Currently, intraocular disease is primarily treated via COMS-plaques brachytherapy. Various stereotactic approaches via photons/proton beam have also been implemented (CyberKnife/GammaKnife/p...
Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman
Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity
Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...
Authors: Fatemeh Akbari, Artemis Dalby, Nelson A. Miksys, Prarthana Pasricha, Rowan M. Thomson
Affiliation: Ackerman Cancer Center, Carleton University
Abstract Preview: Purpose: To investigate dose evaluations for GammaTile brachytherapy, a novel treatment for brain malignancies. The analysis focuses on the impact of tissue heterogeneities, including the presence of ...
Authors: Woong Cho, Jin-Beom Chung, Moo-Jae Han, Sang Won Kang, Boram Lee
Affiliation: Department of Radiation Oncology, Seoul National University Boramae Medical Center, Department of Radiation Oncology, Seoul National University Bundang Hospital, Department of Radiation Oncology, Inha University Hospital
Abstract Preview: Purpose: This study aims to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy by evaluating self-developed polycrystalline semiconductor dosimeters (PSDs).
Me...
Authors: Abby E. Besemer, Carolyn Eckrich, John M. Floberg, Michael J. Lawless, Jessica R. Miller, Joseph B. Schulz, Jordan M. Slagowski, Autumn E. Walter-Denzin
Affiliation: University of Wisconsin-Madison Department of Medical Physics, University of Wisconsin-Madison Department of Human Oncology, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: The aim of this treatment planning study was to evaluate the feasibility of escalating dose with HDR prostate brachytherapy to imaging-identified intraprostatic macroscopic lesions while mode...
Authors: Deidre Batchelar, Michael Kudla, Stephanie Merkl, Tony Teke
Affiliation: BC Cancer - Kelowna
Abstract Preview: Purpose: Preplanning 3D-printed templates for cervical and vaginal brachytherapy is an iterative process, often taking hours to for an individual patient.
This study demonstrates an end-to-end auto...
Authors: Yijian Cao, Jenghwa Chang, Nicholas Coupey, Lyu Huang, Jessica Jung
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose:
The Synergy bioabsorbable polymer (BP) stent, made of Platinum Chromium Alloy, is widely utilized in treating coronary artery disease. This study investigates dose perturbations caused by ...
Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart
Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington
Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...
Authors: Hania A. Al-Hallaq, Duncan Henry Bohannon, Chih-Wei Chang, Anees H. Dhabaan, Vishal Dhere, H Scott McGinnis, Pretesh Patel, Sagar Patel, Keyur Shah, Xiaofeng Yang, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Two-fraction proton SABR is an attractive alternative to brachytherapy for localized prostate cancer. However, potential interfractional anatomical changes necessitate online adaptation, espe...
Authors: Mojtaba Behzadipour, Suman Gautam, Tianjun Ma, Ikchit Singh Sangha, Bongyong Song, William Song, Kumari Sunidhi
Affiliation: UC San Diego, Virginia Commonwealth University
Abstract Preview: Purpose: This study aims to develop a knowledge-based voxel-wise dose prediction system using a convolutional neural network (CNN) for high-dose-rate (HDR) prostate brachytherapy and to evaluate its p...
Authors: Palanisamy Karunanithi, Karthikeyan Perumal, Siva Subramanian Vadivel
Affiliation: Dr. Kamakshi Memorial Hospital
Abstract Preview: Purpose:
Recent advancements in high dose-rate (HDR) brachytherapy include the image guidance, new applicators, and dose calculation algorithms. Brachytherapy has steep dose gradient, hence relativ...
Authors: Peter G. Maxim, Michael P. Reilly, Mengying Shi, Maryam Shirmohammad, Darren M. Zuro
Affiliation: University of California Irvine
Abstract Preview: Purpose: This study aims to assess the positional accuracy of HDR brachytherapy ring applicators, quantify the extent of positional deviation, and provide clinical recommendations for GYN HDR brachyth...
Authors: Eric C. Ford, Awusi Kavuma, Solomon Kibudde, Lilie Lin, Apollo Muramuzi, Nibedita Paul, Peniel T Twum, Afua A. Yorke
Affiliation: Uganda Cancer Institute, MD Anderson Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Nebraska, Global Communities
Abstract Preview: Purpose: Sub-Saharan Africa accounts for over one-third of global cervical cancer deaths, despite representing only 14% of the worldβs female population. At the only RT center in Uganda, prior studies...
Authors: Diandra Ayala-Peacock, Junzo Chino, Oana I. Craciunescu, Allison Jones, Kyle J. Lafata, Kim Light, Sheridan G. Meltsner, Jack B Stevens
Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke University Medical Center
Abstract Preview: Purpose: This study aims to develop an MR-based method that retrospectively correlates longitudinal changes in morphology and physiology for the bulboclitoris and vaginal canal with dose received duri...
Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira
Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center
Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...
Authors: Elizabeth K. Butker, Cara Cimmino, Jenna L. Fair, David Matthew Giles, Bruce Hershatter, Shadab Momin, Sagar Patel, John Pattaras, Kamran Salari Salari, Aaron Weiss
Affiliation: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Emory University School of Medicine
Abstract Preview: Purpose: Prostate cancer patients may experience a local-only failure after radiation. While high-dose-rate (HDR) brachytherapy may have more favorable toxicity profile and cancer control compared to ...
Authors: Kim Creach, Kim Howard, Julius G. Ojwang, Richard A. Shaw, Neelu Soni
Affiliation: Mercy Hospital Springfield
Abstract Preview: Purpose: To present a standardized MRI-CT hybrid workflow for High-Dose-Rate (HDR) Image-Guided Adaptive Brachytherapy (IGBT) in cervical cancer, aligned with AAPM TG-303, as a model to assist with im...
Authors: Kevin Albuquerque, Ti Bai, Yesenia Gonzalez, Brian A. Hrycushko, Zohaib Iqbal, Paul M. Medin, Shanshan Tang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cervical cancer remains one of the most common and significant gynecological (GYN) malignancies globally, often presenting at advanced stages where radiation therapy and high-dose-rate (HDR) ...
Authors: Jenny Dankelman, Ben J. M. Heijmen, Inger-Karine K. Kolkman-Deurloo, Remi A. Nout, Linda Rossi, Robin Straathof, Linda Wauben, Henrike Westerveld, Nick J. van De Berg, Sharline M. van Vliet - Perez
Affiliation: Department of BioMechanical Engineering, Delft University of Technology, Department of Gynecological Oncology, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam
Abstract Preview: Purpose:
To quantify the dosimetric advantages of the 3D-printed patient-tailored ARCHITECT applicator with optimized needle channel configurations compared to clinically used intracavitary/interst...
Authors: Clara Ferreira, Tomas Agustin Montenegro, Courtney C. Oare
Affiliation: University of Minnesota
Abstract Preview: Purpose: This work provides a simulated proof of concept for the use of intravitreal gold nanoparticle (AuNP) during eye plaque brachytherapy as a radiation shield to critical structures in the eye us...