Search Submissions 🔎

Results for "hdr prostate": 21 found

A Setup and Workflow for Fully Automated Electromagnetic Tracking-Based Implant Reconstruction in Intraoperative Prostate HDR Brachytherapy

Authors: Ioannis Androulakis, Miranda E.M.C. Christianen, Jérémy Godart, Mischa Hoogeman, Inger-Karine K. Kolkman-Deurloo, Lorne Luthart, Remi A. Nout, Henrike Westerveld

Affiliation: Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center, Rotterdam, The Netherlands, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam

Abstract Preview: Purpose:
Despite the advantages of transrectal ultrasound-based treatment planning for HDR prostate cancer brachytherapy which allows on-line treatment delivery in the intraoperative setting, it is...

Clinical Validation of Fully Automated Script for Plan Conversion between Linacs with Different Mlc Model

Authors: David L. Barbee, Paulina E. Galavis, Lena Adel Samad, Jose R. Teruel Antolin

Affiliation: NYU, NYU Langone Health

Abstract Preview: Purpose: To validate an automated script that converts treatment plans of varying Varian MLC models

Methods: A C# script was developed using the Eclipse Scripting API to convert treatment plans...

Development of a Robust 3D-Ultrasound (3DUS) Quality Assurance (QA) Framework for a Real-Time Needle-Tracking System in HDR GYN Brachytherapy

Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity

Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...

Dosimetric Feasibility of Dominant Intraprostatic Lesion Dose Escalation in HDR Prostate Brachytherapy

Authors: Abby E. Besemer, Carolyn Eckrich, John M. Floberg, Michael J. Lawless, Jessica R. Miller, Joseph B. Schulz, Jordan M. Slagowski, Autumn E. Walter-Denzin

Affiliation: University of Wisconsin-Madison Department of Medical Physics, University of Wisconsin-Madison Department of Human Oncology, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: The aim of this treatment planning study was to evaluate the feasibility of escalating dose with HDR prostate brachytherapy to imaging-identified intraprostatic macroscopic lesions while mode...

Enhanced Pelvic Organ Segmentation Using LLM-Driven Prompts for Prostate Cancer Low-Dose-Rate Brachytherapy

Authors: Yang Lei, Tian Liu, Ren-Dih Sheu, Meysam Tavakoli, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Emory University

Abstract Preview: Purpose:
The study aimed to improve target and organ at risk (OAR) segmentation in low-dose-rate brachytherapy (LDR-BT) for prostate cancer treatment, by integrating clinical guidelines into deep l...

Evaluation of Dose-Rate Metrics in Intensity Modulated Proton Therapy for Prostate Cancer Treatments

Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University

Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...

From Concept to Clinic: A Phase-Based Approach for Implementing Auto-Segmentation in Radiation Therapy

Authors: Elizabeth L. Covington, Robert T. Dess, Charles S. Mayo, Michelle L. Mierzwa, Dan Polan, Jennifer Shah, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan

Abstract Preview: Purpose: Auto-segmentation improves contour consistency and standardization in radiation therapy but may introduce variations from current practices, potentially impacting treatment outcomes and toxic...

Image Quality Enhancement for Transrectal Ultrasound Imaging of Prostate Brachytherapy Using Deep Learning: A Needle Eraser

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Serdar Charyyev, Xianjin Dai, PhD, Yu Gao, Thomas R. Niedermayr, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: Real-time transrectal ultrasound imaging is the gold standard for needle placement and treatment planning of real-time based-ultrasound-based high dose-rate (HDR) prostate brachytherapy. Cumu...

Improving Segmentation Precision in Prostate Cancer Adaptive Radiotherapy with the Intentional Deep Overfit Learning (IDOL) Approach

Authors: Seungryong Cho, Donghyeok Choi, Joonil Hwang, Byung-Hee Kang, Jin Sung Kim, Eungman Lee, Younghee Park

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, KAIST, Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Ewha Womans University of Medicine

Abstract Preview: Purpose: Radiation therapy (RT) is critical for cancer treatment, but changes in tumor size and shape during therapy challenge precise dose delivery. Adaptive radiation therapy (ART) addresses these v...

Influence of Intrafraction Motion on the Dosimetry of Prostate Treatments

Authors: María Fernández, Inés Flores, Nuria Montero, Manuel Ruiz, Francisco San Miguel

Affiliation: Hospital Central de la Defensa 'Gómez Ulla', Hospital Central de la Defensa "Gomez Ulla", CSVE, Hospital Central de la Defensa 'Gómez Ulla', CSVE

Abstract Preview: Purpose:
During external radiotherapy treatments in the prostate, there can be PTV movements between fractions and during each treatment fraction. In a typical prostate treatment in our institution...

Integrated Catheter Position and Dwell Time Optimization for Focal Dose Escalation in Prostate HDR Brachytherapy

Authors: Bryan Bednarz, John M. Floberg, Joseph B. Schulz, Jordan M. Slagowski

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Catheter placement for high-dose-rate brachytherapy (HDR BT) is clinician dependent and potentially suboptimal for delivering simultaneous integrated boosts to intraprostatic gross tumor volu...

Knowledge-Based Three-Dimensional Dose Prediction for High Dose Rate Prostate Brachytherapy

Authors: Mojtaba Behzadipour, Suman Gautam, Tianjun Ma, Ikchit Singh Sangha, Bongyong Song, William Song, Kumari Sunidhi

Affiliation: UC San Diego, Virginia Commonwealth University

Abstract Preview: Purpose: This study aims to develop a knowledge-based voxel-wise dose prediction system using a convolutional neural network (CNN) for high-dose-rate (HDR) prostate brachytherapy and to evaluate its p...

Mapping Dosimetry, Excision Probability, and Mpmri Pixel Data to Core-Needle Biopsy Tissue from HDR Prostate Brachytherapy

Authors: Jeffrey Andrews, Nathan E. Becker, Juanita Crook, Andrew Jirasek, Matthew Jonathan Muscat

Affiliation: UBC, BC Cancer Agency, BC Cancer

Abstract Preview: Purpose: To map dosimetry and imaging information to ultrasound and multi-parametric magnetic resonance (mpMR) guided trans-perineal core-needle biopsies, performed during two-fraction prostate high-d...

Modernization of the NIST Air-Kerma Strength Standard for LDR Brachytherapy Seeds

Authors: Michael G. Mitch, Csilla I. Szabo-Foster

Affiliation: National Institute of Standards and Technology

Abstract Preview: Purpose: The U.S. air-kerma strength standard for low-dose-rate (LDR) low-energy photon-emitting brachytherapy sources provides measurement traceability for calibrations at the AAPM Accredited Dosimet...

Oncoseed: Automated Workflow Generation for Pre-or and or-Plan Comparison in Prostate Seed Implants

Authors: Jaehee Chun, Jin Sung Kim, Siddhant Sen, James J. Sohn, Ethan D. Stolen

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Psychology, University of Illinois Urbana-Champaign, Oncosoft Inc

Abstract Preview: Purpose: In LDR brachytherapy for prostate cancer, anatomical changes between pre-planning and implantation require adjustment of needle and seed configurations. Currently, clinics spend significant t...

Quantifying the Impact of Tissue Inhomogeneities on Calculated Dosimetry within LDR Brachytherapy

Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer

Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...

Rectal Spacer Injection on the Day of HDR Prostate Brachytherapy Enhances Dosimetry and Reduces Rectal Dose for Patients Receiving Combined Brachytherapy and EBRT.

Authors: Francis A Asamoah, David D. Campos, Jordan A Holmes, Ke Colin Huang, Omar Ishaq, Sook Kien Ng, Arpan Prabhu, Edwin Quashie, Yong Yue

Affiliation: Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Evaluate a novel rectal spacer workflow with spacer injection during brachytherapy to streamline logistics, reduce hospital visits and costs, and compare the benefits of SpaceOAR Vue and Barr...

Salvage High-Dose-Rate Brachytherapy for Locally Recurrent Prostate Cancer Treating Whole Gland with Focal Boost in Two Fractions

Authors: Elizabeth K. Butker, Cara Cimmino, Jenna L. Fair, David Matthew Giles, Bruce Hershatter, Shadab Momin, Sagar Patel, John Pattaras, Kamran Salari Salari, Aaron Weiss

Affiliation: Department of Radiation Oncology and Winship Cancer Institute, Emory University, Emory University School of Medicine

Abstract Preview: Purpose: Prostate cancer patients may experience a local-only failure after radiation. While high-dose-rate (HDR) brachytherapy may have more favorable toxicity profile and cancer control compared to ...

Spatial Dosimetric-Based Prediction of Long-Term Urinary Toxicity after Permanent Prostate Brachytherapy

Authors: Rajeev K. Badkul, Ronald C Chen, Ying Hou, Harold Li, Chaoqiong Ma, Jufri Setianegara

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose:
Postimplant urinary toxicity is common in prostate low-dose-rate (LDR) brachytherapy. We developed a machine learning (ML) model to explore the correlation between spatial dose distributio...

Synthetic CT Generation from a Cycle Diffusion Model Based Framework for Ultrasound-Based Prostate HDR Brachytherapy

Authors: Michael Baine, Charles Enke, Yang Lei, Yu Lei, Ruirui Liu, Su-Min Zhou

Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center, Department of Radiation Oncology, University of Nebraska Medical Center

Abstract Preview: Purpose: This study presents a framework for generating synthetic CT images using a Cycle Diffusion model, which can be utilized to enhance needle conspicuity in ultrasound-guided prostate HDR brachyt...

Weakly Supervised Spatial Implicit Neural Representation Learning for 3D MRI-Ultrasound Deformable Image Registration in HDR Prostate Brachytherapy

Authors: Michael Baine, Yang Lei, Yu Lei, Ruirui Liu, Tian Liu, Jing Wang

Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center

Abstract Preview: Purpose: Accurate 3D deformable registration of MRI and ultrasound (US) is essential for real-time image guidance during high-dose-rate (HDR) prostate brachytherapy. However, MRI-US registration of th...