Search Submissions 🔎

Results for "icbct mar": 68 found

A Comparative Study of Hypersight and Truebeam Cone Beam Computed Tomography Image Quality

Authors: Sorour Hosseini, YuHuei Jessica Huang, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To evaluate image quality—including noise, contrast-to-noise ratio (CNR), uniformity, and low-contrast visibility (LCV)—on the HyperSight and TrueBeam cone-beam computed tomography (CBCT) pla...

A Modular Approach to Reversible and Stackable Medical Imaging Translation Models: CBCT-Based Synthetic MRI with Multiple U-Nets in Series (MUNETs)

Authors: Eric Chang, Nguyen Phuong Dang, Andrew Lim, Lauren Lukas, Lijun Ma, Yutaka Natsuaki, Zhengzheng Xu, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: Harnessed the power of AI and Deep Learning (DL), Generalized Neural Network models for medical image transformation are trained to predict target images from reference images, often requirin...

A Novel Linac Onboard Dual-Layer Kv Imager Provides Increased Clinical CBCT Contrast and Metal Artifact Reduction Using Virtual Monoenergetic Images

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Dual-energy imaging offers benefits, including metal artifact reductions (MAR) and improved contrast, that enhance visualization. Currently, dual-energy imaging is largely limited to CT scann...

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

A Pilot Survey on Medical Physics Residency Education in External Beam Special Procedures

Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng

Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester

Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...

A Quantitative Analysis of Hypersight CBCT Image Quality Using a Phantom-Based Approach Under Different Scatter Conditions

Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...

A Self-Supervised Deep Learning Approach for Automatic Identification and Metal Artifact Reduction in Cone-Beam CT for Brachytherapy

Authors: Rani Anne', Wenchao Cao, Yingxuan Chen, Wookjin Choi, Firas Mourtada, Yevgeniy Vinogradskiy

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: In-room mobile cone-beam CT (CBCT) is emerging to enhance high-dose-rate (HDR) brachytherapy workflow using on-demand imaging. However, metal artifacts from X-ray markers inside gynecological...

Advancing Thoracic Synthetic CT Images with Enhanced Cyclegan for Adaptive Radiotherapy Applications

Authors: Silambarasan Anbumani, Nicolette O'Connell, Eenas A. Omari, Amanda Pan, Eric S. Paulson, Lindsay Puckett, Monica E. Shukla, Dan Thill, Jiaofeng Xu

Affiliation: Elekta Inc, Elekta Limited, Linac House, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate electron density information from on-board imaging is essential for direct dose calculations in adaptive radiotherapy (ART). This study evaluates a deep learning model for thoracic s...

An Accelerated Scatter Estimation for Spectral CBCT Based on Linear Boltzmann Transport Equation

Authors: Zhiqiang Chen, Hewei Gao, Li Zhang, Guoxi Zhu

Affiliation: Tsinghua University

Abstract Preview: Purpose: Spectral cone-beam CT has better performance in material identification and quantitative analysis compared to single-energy cone-beam CT. However, X-ray scattering introduces significant scat...

An Adaptive Radiotherapy Approach Sparing Preirradiated Critical Structures

Authors: Mohamed Bahaaeldin Mohamed Afifi, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Reirradiation of recurrent cancer or a newly developed lesion in a proximal location poses a challenge for radiation treatments. This is occasionally encountered in many modern clinics and ef...

An Adaptive Radiotherapy Strategy Study Based on Segmented Synthesis and Deformational Registration

Authors: Jie Hu, Zhengdong Jiang, Nan Li, Tie Lv, Yuqing Xia, Shouping Xu, Gaolong Zhang, Wei Zhao, Changyou Zhong

Affiliation: School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Radiotherapy Department of Meizhou People’s Hospital (Huangtang Hospital), UT Health San Antonio, National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, Peopleʼs Republic of China, Department of Radiation Oncology

Abstract Preview: Purpose: Patients usually undergo cone-beam computed tomography (CBCT) scans which are used for patient set-up before radiotherapy. However, the low image quality of CBCT hinders its use in adaptive r...

An Efficient Workflow for X-Ray Imaging-Based IGRT/ART

Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...

Analysis of the Accuracy of Avatar-Based Patient Positioning Technique for Radiation Therapy

Authors: Danna Gurari, Moyed Miften, Sarah Milgrom, Atharva Rajesh Peshkar, Willem Schreuder, David H. Thomas

Affiliation: University of Colorado Boulder, University of Colorado School of Medicine, University of Colorado Anschutz, Thomas Jefferson University

Abstract Preview: Purpose: To evaluate the accuracy of a novel avatar-based patient positioning technique.

Methods: We developed a modified surface-guided radiation therapy (SGRT) technique, 'Avatar-Guided Radia...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

Assessing the Impact of Intrafraction Shifts on Critical OAR Doses in a Standardized Spine SBRT Program

Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann

Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania

Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...

Automated Determination of Deteriorations in Proton Therapy Plan Quality Using Daily Cone Beam CT As a Predictor of Need for Adaptive Replans for Head and Neck Cases

Authors: Matthew J Ferris, Jason K Molitoris

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland

Abstract Preview: Purpose: Anatomy changes often happen in head-and-neck (HN) patients treated with proton radiation therapy. These changes can result in deteriorations of target dose coverage and increased dose to org...

Big Data in-Vivo Epid Image Prediction for VMAT Radiotherapy

Authors: Casey E. Bojechko, Lance C Moore

Affiliation: University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: EPID images collected during treatment can serve as an in-vivo error detection mechanism. Previous works have shown that comparing in-vivo EPID images to AI-predicted EPID images for IMRT pla...

Biomechanically Guided Deep Learning for Deformable Multimodality Liver Registration Framework

Authors: Yunfei Dong, Dongyang Guo, Zhenyu Yang, Fang-Fang Yin, Zeyu Zhang

Affiliation: Duke University, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
To develop a Biomechanically Guided Deep Learning Registration Network (BG-DRNet) that improves both accuracy and physiological plausibility in liver image registration. While cone-beam CT...

CBCT-Based Synthetic CT Imaging for Proton and Photon Dose Monitoring and Adaption in Supine Breast Radiotherapy

Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang

Affiliation: UF Health Proton Therapy Institute, University of Florida

Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...

Can We Use Smaller Margin for the Planned Target Volume with Adaptive Radiotherapy?

Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center

Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...

Comparison of CBCT Dose Calculation Accuracy between Truebeam Hypersight Image Reconstruction Algorithms

Authors: Sarah Aubert, Harald Keller, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: Support for treatment planning directly on CBCT imaging on C-arm linacs will enable adaptive radiation therapy (ART) capacity with increased treatment technique flexibility. The HyperSight im...

Comparison of Frame-Based and Frameless Gamma Knife Coordinate Spaces for Treatment of Trigeminal Neuralgia

Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...

Comparison of Patient Localization on Visionrt Alignrt and Varian Identify

Authors: Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Surface imaging has been used clinically more regularly. The accuracy of several commercial products has been studied. AAPM TG302 also has proposed the system quality assurance and commission...

Correlation between Imaging Dose and Image Quality for Hypersight CBCT

Authors: Stephen Bhagroo, Sorour Hosseini, YuHuei Jessica Huang, Jeremy Kunz, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Ryan G. Price, Hui Zhao

Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah

Abstract Preview: Purpose: To investigate the correlation between HyperSight CBCT imaging dose and image quality.
Methods: Six-series of 174 CBCT scans were acquired using HyperSight on Halcyon (125kV, 133-971mAs, F...

Cross-Slice Attention for Unsupervised 3D Pelvic CBCT to CT Translation

Authors: Xu Chen, Jun Lian, Yunkui Pang, Pew-Thian Yap

Affiliation: University of North Carolina at Chapel Hill, Huaqiao University

Abstract Preview: Purpose: Unsupervised CBCT-to-CT translation in the pelvic region is essential for accurate radiotherapy delivery and adaptive image-guided interventions. However, current models for cross-modality tr...

Cycle-Consistent Multi-Task Automated Segmentation and Synthetic CT Generation Model for Adaptive Proton Therapy

Authors: Derek Tang, Susu Yan

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: To evaluate the performance of a multi-task automated-segmentation and synthetic CT generation model (sCT) and investigate its application in an adaptive proton therapy workflow.
Methods: ...

Deep Learning-Based Fast CBCT Imaging with Orthogonal X-Ray Projections for Gynecological Cancer Radiotherapy

Authors: Beth Bradshaw Ghavidel, Chih-Wei Chang, Yuan Gao, Priyanka Kapoor, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Jill Remick, Justin R. Roper, Zhen Tian, Xiaofeng Yang

Affiliation: Whinship Cancer Institute, Emory University, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Current cone-beam computed tomography (CBCT) typically requires no less than 200 degrees of angular projections, which prolongs scanning time and increases radiation exposure. To address thes...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Development of an MRI Guided Precision Small Animal Radiotherapy System

Authors: Yaowen Cao, Yunwen Huang, Yidong Yang, Xiaogang Yuan, Ning Zhao, Cheng Zheng

Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: MRI has better soft tissue contrast than cone beam CT which is commonly used in image guided radiotherapy. This study aims to develop a low-field MRI system for precision small animal radiati...

Direct Dose Verification in Liver SBRT Utilizing an Accumulative Daily CBCT Algorithm

Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...

Enhancing Radiation Oncology Imaging with a Novel Variational Model Decomposition, Radon Transformation, and Kohonen Self-Organizing Map Denoising Framework

Authors: Hassan Bagher-Ebadian, Justine M. Cunningham, Anthony J. Doemer, Mohammad M. Ghassemi, Joshua P. Kim, Benjamin Movsas, Kundan S Thind

Affiliation: Michigan State University, Henry Ford Health

Abstract Preview: Purpose: Reduction of noise in medical images critically enables improved accuracy in delineating tumors and organs at risk, leading to more precise treatment planning and safer image-guided radiation...

Enhancing Synthetic Pelvic CT Images from CBCT Using Vision Transformer with Adaptive Fourier Neural Operators

Authors: Rashmi Bhaskara, Oluwaseyi Oderinde

Affiliation: Purdue University

Abstract Preview: Purpose: This study proposes a novel approach to overcoming CBCT image quality limitations by developing an improved synthetic CT (sCT) generation method based on a CycleGAN architecture using Vision ...

Evaluating the Capabilities of Hypersight CBCT for Advanced Dual-Energy CBCT Imaging in Online Adaptive Radiotherapy

Authors: Yi-Fang Wang, Yading Yuan

Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center

Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...

Evaluation of Concomitant Imaging Dose in 4D-CBCT Guided Thoracic Radiotherapy

Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao

Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...

Evaluation of Daily Respiratory Pattern from a Single Free-Breathing Cone Beam CT Scan

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...

Evaluation of Thoracic Direct Dose Calculation Using Truebeam Linac with Hypersight Imaging CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...

Evaluation of a Commercial Metal Artifact Reduction Algorithm for IGRT in Patients with Hip Prostheses

Authors: Laura Bennett, Matthew Charles, Greg Cooley, John M. Floberg, Ryan Hutten, Elissa Khoudary, Nicholas Lynch, Kaili Ranta, Jordan M. Slagowski, Trevor Wilson

Affiliation: University of Pennsylvania, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, University of Wisconsin-Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: To evaluate the impact of an iterative cone beam CT with metal artifact reduction (iCBCT+MAR) reconstruction algorithm (HyperSight TrueBeam 4.1, Varian Medical Systems) on image quality and s...

Evaluation of a Commercially Available Solution for Dose Verification Using Daily AI Generated Pseudo-CT from CBCT.

Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina

Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.

Methods: Dose calculations in water phan...

FMEA for Direct to Unit Adaptive Radiotherapy

Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert

Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis

Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

High-Fidelity Synthetic CT Generation from CBCT for Dibh Breast Cancer Patients Using Shortest Path Regularization

Authors: Manju Liu, Weiwei Sang, Yanyan Shi, Zhenyu Yang, Fang-Fang Yin, Chulong Zhang, Lihua Zhang, Rihui Zhang

Affiliation: Jiahui International Hospital, Jiahui International Hospital, Radiation Oncology, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: This study aims to transform cone-beam computed tomography (CBCT) images acquired from deep inspiration breath-hold (DIBH) breast cancer patients into high-fidelity synthetic CT (sCT) images....

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

High-Quality Patchnet (HQ-PatchNet) for Synthetic CT Generation in Head & Neck Imaging

Authors: So Hyun Ahn, Chris Beltran, Byongsu Choi, Jeong Heon Kim, Jin Sung Kim, Bo Lu, Justin Chunjoo Park, Bongyong Song, Jun Tan

Affiliation: Mayo Clinic, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Ewha Medical Research Institute, Ewha Womans University College of Medicine, UC San Diego, Yonsei University College of Medicine

Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) is widely used in IGRT for patient positioning but suffers from low resolution and poor soft tissue contrast. Synthetic CT (sCT) generated from CBCT ad...

Hypersight-Archer Study: Improved Target Coverage and Organ-at-Risk Sparing Via Adaptive Radiotherapy of Head and Neck Cancer Using Direct-Dose Calculation on Cone Beam CT

Authors: Cheryl Anderson, Lara Best, Amanda Cherpak, Jennifer DeGiobbi, Marc C. LeBlanc, R. Lee MacDonald, Peter R. Martin, Natasha McMaster, Murali Rajaraman, James L. Robar, Lucy Ward, Derek Wilke, Kenny Zhan

Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health

Abstract Preview: Purpose: This work investigates the potential benefit of adaptive planning using the Ethos radiotherapy system (Varian Medical Systems) with direct-dose calculation on HyperSight cone beam CT (CBCT) f...

Hypersight® Offline Adaptive Workflow

Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC

Abstract Preview: Purpose: The goal of the HyperSight® offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...

Immobilization and Optimization of Pulse Sequences for 0.23T MRI

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
It has been challenging to acquire clinically useful MR images of pediatric cancer patients without anesthesia, and MR contrast agents. Custom-made immobilization devices and optimization ...

In-Vivo Image Quality of Head/Neck and CNS with an Advanced C-Arm Linac CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Christian Erik Petersen, Alex T. Price, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: CBCT is subject to more artifacts due to increased photon scatter, especially in areas of increased tissue heterogeneities compared to fan-beam CTs (FBCTs). Improved imaging panels combined w...

Initial Comparison of 3D CBCT Performance: New Mobile C-Arm Vs. O-Arm Unit

Authors: Wendy Siman, Wei Zhou

Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine

Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-µm tungsten wire was imaged at ...

Initial Phantom Studies Towards Implementation of Sequential Dual Energy CBCT on an Adaptive Radiotherapy Linac Platform

Authors: James M. Balter, Alexander Moncion, Ikechi S Ozoemelam

Affiliation: University of Michigan

Abstract Preview: Purpose: Sequential dual-energy cone beam computed tomography (DE-CBCT) integrated with an online adaptive platform could potentially improve soft tissue visualization for more accurate anatomical del...

Inter-Patient Adaptive Radiotherapy (IPART): A CT Simulation and Planning Free Approach Enabling Immediate Treatment Access for Patients.

Authors: Bin Cai, Andrew R. Godley, Brian A. Hrycushko, Heejung Kim, Mu-han Lin, David D.M. Parsons, Justin D. Visak, Da Wang, Tingliang Zhuang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: The standard radiation therapy workflow requires CT-simulation and planning, whether for initial treatments or re-planning due to significant anatomical changes. IPART instead uses one patien...

Investigation of Metallic Artefact Reduction Capabilities of Hypersight Enabled Platforms

Authors: Harald Keller, Iymad Mansour, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...

Knowledge-Based Online Adaptive Proton Stereotactic Ablative Radiotherapy (SABR) for Localized Prostate Cancer Using Gaussian Process Regression

Authors: Hania A. Al-Hallaq, Duncan Henry Bohannon, Chih-Wei Chang, Anees H. Dhabaan, Vishal Dhere, H Scott McGinnis, Pretesh Patel, Sagar Patel, Keyur Shah, Xiaofeng Yang, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Two-fraction proton SABR is an attractive alternative to brachytherapy for localized prostate cancer. However, potential interfractional anatomical changes necessitate online adaptation, espe...

Linac Based Dose-Escalated Radiation Therapy for Pancreatic Cancer: Assessing Respiratory Motion

Authors: Neal Andruska, Lianna D. DiMaso-Myers

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: To provide details on how our clinic assesses respiratory motion during treatment of a pancreatic adenocarcinoma during dose escalated radiation therapy on a linear accelerator with the aid o...

Mask-Less Adaptable Headrest for Head-and-Neck Radiotherapy

Authors: Alyssa Capizzi, John J Dombrowski, Nabil N. Khater

Affiliation: Saint Louis University

Abstract Preview: Purpose: To evaluate a mask-less adaptable headrest (MAHR) prototype for head-and-neck IMRT designed to reduce random and systematic shifts of patients’ setups. MAHR complements current image-guidance...

Memory-Efficient Deep Learning for Volumetric Cone-Beam CT Image Reconstruction

Authors: Ziqi Gao, Lei Xing, Siqi Ye, S. Kevin Zhou

Affiliation: Department of Radiation Oncology, Stanford University, University of Science and Technology of China (USTC)

Abstract Preview: Purpose: To address the challenge of high memory usage in volumetric cone-beam CT (CBCT) imaging, we propose a method that combines joint reconstruction and super-resolution for sparsely sampled CBCT ...

Novel 3D Imaging Systems for Surgical Guidance : Loop-X and Nview S1 in Comparison with O-Arm

Authors: Jia Wang, Vani Yadav

Affiliation: Stanford University

Abstract Preview: Purpose: To evaluate the radiation dose and imaging quality of two novel CBCT X-Ray imaging systems used in spine surgeries.
Methods: CBCT scan of ACR CT and CTDI phantoms was performed to acquire ...

Optimization-Based Image Reconstruction Regularized with Inter-Spectral Structural Similarity for Limited-Angle Dual-Energy Cone-Beam CT

Authors: Chih-Wei Chang, Junbo Peng, Richard L.J. Qiu, Justin Roper, Xiangyang Tang, Tonghe Wang, Huiqiao Xie, Xiaofeng Yang, David Yu

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Emory Univ, Emory University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered a promising solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, ...

Personalized Anisotropic Margin Strategy for Cervical Cancer Online Adaptive Radiation Therapy

Authors: Jian Chen, Qiufen Guo, Aihua Li, Jing Liu, Junjie MA, Qian WU, Haonan Xiao, Peng Xie, Xiaohui Yan, Yong Yin, Zhe Zhang

Affiliation: Department of Radiation Oncology, Peking University Shenzhen Hospital, Department of Radiation Oncology and Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Obstetrics and Gynaecology, Liao Cheng People’s Hospital

Abstract Preview: Purpose: Online Adaptive radiation therapy (ART) has been an effective technique to manage patient’s inter-fractional anatomical changes and therefore reduces planning target volume (PTV). However, on...

Predicting CBCT-Based Adaptive Radiation Therapy Session Duration Using Machine Learning

Authors: Leslie Harrell, Sanjay Maraboyina, Romy Megahed, Maida Ranjbar, Xenia Ray, Pouya Sabouri

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), University of California San Diego

Abstract Preview: Purpose: Real-time adaptive radiation therapy (ART) dynamically modifies patients’ treatment plan during delivery to account for anatomical and physiological variations. Addressing ART planning time v...

Preliminary Clinical Experience with MRI-Guided Online Adaptive Radiotherapy for Esophageal Cancer Patients

Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu

Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health

Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...

Radiobiological Calculations of Daily Doses Using Pseudo CT (pCT)

Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina

Abstract Preview: Purpose:
To calculate radiobiological metrics of daily dose delivered for head and neck (HN) patients using the daily cone beam CT (CBCT) to generate a pseudo CT (pCT). Moreover, this work compares...

Rapid CBCT Imaging with Ultra-Sparse X-Ray Projections for Head & Neck Cancer Radiotherapy

Authors: Hania A. Al-Hallaq, Chih-Wei Chang, Anees H. Dhabaan, Yuan Gao, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Keyur Shah, Sibo Tian, Zhen Tian, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Emory University, Whinship Cancer Institute, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Traditional cone-beam computed tomography (CBCT) often requires multiple angular projections, increasing radiation exposure and extending scanning times, which may lead to heightened patient ...

Rectal Spacer Injection on the Day of HDR Prostate Brachytherapy Enhances Dosimetry and Reduces Rectal Dose for Patients Receiving Combined Brachytherapy and EBRT.

Authors: Francis A Asamoah, David D. Campos, Jordan A Holmes, Ke Colin Huang, Omar Ishaq, Sook Kien Ng, Arpan Prabhu, Edwin Quashie, Yong Yue

Affiliation: Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Evaluate a novel rectal spacer workflow with spacer injection during brachytherapy to streamline logistics, reduce hospital visits and costs, and compare the benefits of SpaceOAR Vue and Barr...

Reproducibility of Target Position during Surface-Guided Breath-Hold Adaptive SBRT of Liver Cancer

Authors: Lili Chen, Xiaoming Chen, Chang Ming Charlie Ma, Joshua Meyer

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Fast CBCT (HyperSight) acquisition technique together with a surface-guided breath-hold (SGBH) would allow a better image quality for accurate target/organ delineation. It facilitates breath-...

Stereotactic Body Radiosurgery for Refractory Ventricular Tachycardia: Presenting Efficient Clinic Workflow, Dosimetric Analysis and Patients Reported Clinical Results

Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology

Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...

Translating AI into Clinical Practice: Real-World Applications in CBCT or MR Guided Online Adaptive Radiotherapy

Authors: Bin Cai

Affiliation: University of Texas Southwestern Medical Center

Abstract Preview: N/A...

Uncertainties on Synthetic-CT Generation from CBCT: Another Layer of Complexity in Abdominal Adaptive Radiotherapy

Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.

Methods: CT and CBCT images from 65 abdominal pat...

Utilizing Bladder Ultrasound to Estimate on-Table Bladder Volume in Prostate Cancer SBRT: Impact on Treatment Setup Consistency and Dosimetric Outcomes

Authors: Minsong Cao, Amar Kishan, Dylan P. O'Connell, Jonathan Pham, Michael Steinberg, Luca F Valle, Michael Xiang

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: To evaluate bladder ultrasound as a surrogate for estimating on-table bladder volume in prostate cancer patients undergoing stereotactic body radiation therapy (SBRT). The study aimed to asse...