Authors: Ziheng Deng, Yao Hao, Runping Hou, Deshan Yang, Jun Zhao, Yufu Zhou
Affiliation: Department of Radiation Oncology, Duke University, School of Biomedical Engineering, Shanghai Jiao Tong University, Washington University School of Medicine, Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine
Abstract Preview: Purpose: 4D CBCT has been developed to provide dynamic images for image-guided radiation therapy. However, as projection data are sorted into sparse and clustered phase-specific bins, 4D CBCT images a...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Bohong Huang, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) is critical in image-guided radiotherapy (IGRT) for visualizing tumor motion. However, sparse projection sampling often introduces sev...
Authors: Aaron Conard, Victoria Croog, Marie Gurka, Lan Lin
Affiliation: Johns Hopkins University
Abstract Preview: Purpose:
This study evaluates the utility of the Active Breathing Coordinator (ABC) and Surface Guided Radiation Therapy (SGRT) techniques in implementing Deep Inspiration Breath Hold (DIBH) for le...
Authors: Sorour Hosseini, YuHuei Jessica Huang, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Hui Zhao
Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah
Abstract Preview: Purpose: To evaluate image qualityāincluding noise, contrast-to-noise ratio (CNR), uniformity, and low-contrast visibility (LCV)āon the HyperSight and TrueBeam cone-beam computed tomography (CBCT) pla...
Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Womenās Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute
Abstract Preview: Purpose: A challenge for dual energy CBCT is that noise and residual errors in material decomposition steps can become amplified when forming low energy, high contrast virtual mono-energetic images (V...
Authors: Yidong Yang, Haolin Zhan
Affiliation: Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose: To develop a fast low-dose method for beam blocker-based CBCT scatter correction and evaluate image quality in phantom study.
Methods: The full number of scatter projections were collected...
Authors: Xiaoxue Qian, Hua-Chieh Shao, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) reduces imaging time and dose but suffers from under-sampling artifacts. 2Dā3D deformable registration addresses this problem by estimating LA-CBCTs from defor...
Authors: Jie Liu
Affiliation: Inova Health System
Abstract Preview: Purpose:
The respiratory signal commonly acquired by using external surrogates or detecting the diaphragm position only represents the phase information and has poor correlation with the tumor moti...
Authors: Eric Chang, Nguyen Phuong Dang, Andrew Lim, Lauren Lukas, Lijun Ma, Yutaka Natsuaki, Zhengzheng Xu, Hualin Zhang
Affiliation: Radiation Oncology, Keck School of Medicine of USC
Abstract Preview: Purpose: Harnessed the power of AI and Deep Learning (DL), Generalized Neural Network models for medical image transformation are trained to predict target images from reference images, often requirin...
Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University
Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...
Authors: Marios Myronakis, Kyriaki Theodorou
Affiliation: Medical Physics Department, Medical School, University of Thessaly
Abstract Preview: Purpose: The development of an integrated application framework for rapid, seamless, and automated calculation of absorbed organ dose for individual patients undergoing kV CBCT imaging over the course...
Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Womenās Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute
Abstract Preview: Purpose: Dual-energy imaging offers benefits, including metal artifact reductions (MAR) and improved contrast, that enhance visualization. Currently, dual-energy imaging is largely limited to CT scann...
Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal
Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre
Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...
Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng
Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester
Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...
Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC
Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...
Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Stephen Shang
Affiliation: South Florida Proton Therapy Institute, SFPRF
Abstract Preview: Purpose: Proton pencil beam scanning therapy is particularly sensitive to field translational shifts and beam range variations, which can degradation of dose distribution and compromise the treatment....
Authors: Jeremy T. Booth, Nicholas Hardcastle, Freeman Jin, Alicja Kaczynska, Paul J. Keall, Chandrima Sengupta
Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, Physical Sciences, Peter MacCallum Cancer Centre, Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney
Abstract Preview: Purpose: An ESTRO survey reported that 71% of radiotherapy centers across 41 countries want to implement real-time image guided radiation therapy (IGRT) to improve patient outcomes. To address this gl...
Authors: Rani Anne', Wenchao Cao, Yingxuan Chen, Wookjin Choi, Firas Mourtada, Yevgeniy Vinogradskiy
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: In-room mobile cone-beam CT (CBCT) is emerging to enhance high-dose-rate (HDR) brachytherapy workflow using on-demand imaging. However, metal artifacts from X-ray markers inside gynecological...
Authors: Grace Jianan Gang
Affiliation: University of Pennsylvania
Abstract Preview: N/A...
Authors: Robert K Chin, Klea Hoxha, Erika Jank, Jesus Juarez, Eulanca Yuka Liu, Dylan P. O'Connell, X. Sharon Qi, Ricky R Savjani
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, Los Angeles, UCLA Radiation Oncology
Abstract Preview: Purpose:
Daily cone beam CT (CBCT) images are acquired prior to each radiotherapy treatment for verifying patient positioning. HyperSight is an advanced imaging solution that replaces standard CBCT...
Authors: Cem Altunbas, Farhang Bayat, Roy Bliley, Rupesh Dotel, Brian Kavanagh, Uttam Pyakurel, Tyler Robin, Ryan Sabounchi
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic, University of Colorado Anschutz Medical Campus
Abstract Preview: Purpose: Automatic segmentation of anatomical structures in CBCT images is key to enabling dose delivery monitoring and online plan modifications in radiotherapy. However, poor image quality can degra...
Authors: Silambarasan Anbumani, Nicolette O'Connell, Eenas A. Omari, Amanda Pan, Eric S. Paulson, Lindsay Puckett, Monica E. Shukla, Dan Thill, Jiaofeng Xu
Affiliation: Elekta Inc, Elekta Limited, Linac House, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Accurate electron density information from on-board imaging is essential for direct dose calculations in adaptive radiotherapy (ART). This study evaluates a deep learning model for thoracic s...
Authors: Zhiqiang Chen, Hewei Gao, Li Zhang, Guoxi Zhu
Affiliation: Tsinghua University
Abstract Preview: Purpose: Spectral cone-beam CT has better performance in material identification and quantitative analysis compared to single-energy cone-beam CT. However, X-ray scattering introduces significant scat...
Authors: Cem Altunbas, Farhang Bayat
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic
Abstract Preview: Purpose:
Low dose imaging and scatter rejection hardware in CBCT reduces X-ray fluence incident on the imager, increasing noise, causing photon starvation artifacts in CBCT images. In this work, we...
Authors: Mohamed Bahaaeldin Mohamed Afifi, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Chang Ming Charlie Ma, Robert A. Price
Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.
Abstract Preview: Purpose: Reirradiation of recurrent cancer or a newly developed lesion in a proximal location poses a challenge for radiation treatments. This is occasionally encountered in many modern clinics and ef...
Authors: Jie Hu, Zhengdong Jiang, Nan Li, Tie Lv, Yuqing Xia, Shouping Xu, Gaolong Zhang, Wei Zhao, Changyou Zhong
Affiliation: School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Radiotherapy Department of Meizhou Peopleās Hospital (Huangtang Hospital), UT Health San Antonio, National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, Peopleʼs Republic of China, Department of Radiation Oncology
Abstract Preview: Purpose: Patients usually undergo cone-beam computed tomography (CBCT) scans which are used for patient set-up before radiotherapy. However, the low image quality of CBCT hinders its use in adaptive r...
Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...
Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...
Authors: Margaret Cunningham Barker, Michael E. Campbell, Peyman Kabolizadeh, A. Nisar Syed, Randy Wei, Lisa M. Wilson-Turner
Affiliation: Memorial Radiation Oncology Medical Group, MemorialCare Todd Cancer Institute
Abstract Preview: Purpose:
Interstitial HDR treatment planning can be time-consuming, with substantial time spent waiting for the patientās arrival and performing manual tasks, such as contouring ROIs and catheter r...
Authors: Danna Gurari, Moyed Miften, Sarah Milgrom, Atharva Rajesh Peshkar, Willem Schreuder, David H. Thomas
Affiliation: University of Colorado Boulder, University of Colorado School of Medicine, University of Colorado Anschutz, Thomas Jefferson University
Abstract Preview: Purpose: To evaluate the accuracy of a novel avatar-based patient positioning technique.
Methods: We developed a modified surface-guided radiation therapy (SGRT) technique, 'Avatar-Guided Radia...
Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...
Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann
Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania
Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...
Authors: Justus Adamson, Wesley Andrew Cunningham, Caleb Logan Smith
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: Radiation induced bowel toxicity is a persistent issue for abdominal Stereotactic Body Radiation Therapy (SBRT). Remote magnetic navigation systems (RMNS) have been developed for use in magne...
Authors: Matthew J Ferris, Jason K Molitoris
Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland
Abstract Preview: Purpose: Anatomy changes often happen in head-and-neck (HN) patients treated with proton radiation therapy. These changes can result in deteriorations of target dose coverage and increased dose to org...
Authors: Quan Chen, Xue Feng, Chunhui Han, Gaofeng Huang, Trevor Ketcherside, Yi Lao, Yun Rose Li, An Liu, Bo Liu, Kun Qing, William T. Watkins
Affiliation: Graduate Program in Bioengineering, University of California San Francisco-UC Berkeley, Department of Radiation Oncology, City of Hope National Medical Center, Mayo Clinic Arizona, Carina Medical LLC
Abstract Preview: Purpose: New treatment platforms such as Ethos (Varian Medical Systems) allow the introduction of multi-modal imaging into adaptive radiotherapy workflow to facilitate an up-to-date view of patientsā ...
Authors: Hailun Pan, Yingli Yang, Jie Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Department of Radiation Oncology, Ruijin Hospital, , Shanghai Jiaotong University School Of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute
Abstract Preview: Purpose: Accurate patient positioning is critical in radiotherapy (RT) to ensure effective treatment delivery and minimize harming surrounding healthy tissues. Vertebral misalignment during RT setup h...
Authors: Alvaro Daniel Cruz Cortes, Robin Enric Lopez Fonseca, Valeria PĆ©rez MartĆnez
Affiliation: National Autonomous University of Mexico (UNAM), Faculty of Sciences, Biomedical Physics Program, National Autonomous University of Mexico (UNAM), Faculty of Sciences, National Autonomous University of Mexico (UNAM), Faculty of Sciences, Physics Program
Abstract Preview: Purpose: Automate and evaluate daily, monthly, and annual QC of IGRT systems, following the AAPM TG-198 protocol, through the development of a graphical user interface that enables efficient analysis ...
Authors: Hua-Chieh Shao, Chenyang Shen, Jiacheng Xie, Shunyu Yan, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas
Abstract Preview: Purpose: Motion-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection), is highly desired for regular/irregular motion chara...
Authors: Peter Balter, Kristy K. Brock, Clifton David Fuller, Tze Yee Lim, James Long, Brigid A. McDonald, Androniki Mitrou, Andrew J. Schaefer, Stina Svensson
Affiliation: The University of Texas MD Anderson Cancer Center, RaySearch Laboratories, Rice University, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences
Abstract Preview: Purpose: CBCT-based accumulated dose can provide up-to-date dose information on responding anatomy. To optimize resources, it is necessary to determine how many scans provide adequate information for ...
Authors: Casey E. Bojechko, Lance C Moore
Affiliation: University of California, San Diego, University of California San Diego
Abstract Preview: Purpose: EPID images collected during treatment can serve as an in-vivo error detection mechanism. Previous works have shown that comparing in-vivo EPID images to AI-predicted EPID images for IMRT pla...
Authors: Yunfei Dong, Dongyang Guo, Zhenyu Yang, Fang-Fang Yin, Zeyu Zhang
Affiliation: Duke University, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
To develop a Biomechanically Guided Deep Learning Registration Network (BG-DRNet) that improves both accuracy and physiological plausibility in liver image registration. While cone-beam CT...
Authors: Yingxuan Chen, Jun Li, Alexis N. Webb
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: Cone-beam computed-tomography (CBCT) is widely used for image-guided therapy. Cumulative dose from repeated CBCT might be a concern. This study aims to measure and compare the CBCT dose for c...
Authors: Martha J. Malin, Matthew Schelin
Affiliation: NYU Langone Health
Abstract Preview: Purpose: To evaluate the agreement between ExacTrac Dynamic (ETD) and CBCT-based positioning for spine SRS/SBRT treatments during initial patient setup and repositioning after intrafraction motion.
Authors: Rodrigo Delgadillo, Nesrin Dogan, Benjamin J. Rich, Stuart E Samuels, Levent Sensoy
Affiliation: University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: Daily Cone beam CT (CBCT) images may be useful in detecting early morphological changes during head and neck cancer radiotherapy. The aim of this study was to evaluate the performance of CBCT...
Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang
Affiliation: UF Health Proton Therapy Institute, University of Florida
Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...
Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price
Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center
Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...
Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng
Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...
Authors: Alan Rui Li, Qihui Lyu, Dan Ruan, Ke Sheng
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
The Sparse Primary Sampling (SPS) grid was shown in a previous computational study to improve image quality by correcting scatter-induced effects and artifacts in Cone-beam Computed Tomogr...
Authors: Sarah Aubert, Harald Keller, Jeff D. Winter
Affiliation: Princess Margaret Cancer Centre
Abstract Preview: Purpose: Support for treatment planning directly on CBCT imaging on C-arm linacs will enable adaptive radiation therapy (ART) capacity with increased treatment technique flexibility. The HyperSight im...
Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...
Authors: Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Surface imaging has been used clinically more regularly. The accuracy of several commercial products has been studied. AAPM TG302 also has proposed the system quality assurance and commission...
Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...
Authors: Stephen Bhagroo, Sorour Hosseini, YuHuei Jessica Huang, Jeremy Kunz, Thomas Boyd Martin, Geoffrey S. Nelson, Nicholas Pierre Nelson, Ryan G. Price, Hui Zhao
Affiliation: University of Utah, Department of Radiation Oncology, Huntsman Cancer Institute, University of Utah
Abstract Preview: Purpose: To investigate the correlation between HyperSight CBCT imaging dose and image quality.
Methods: Six-series of 174 CBCT scans were acquired using HyperSight on Halcyon (125kV, 133-971mAs, F...
Authors: Xu Chen, Jun Lian, Yunkui Pang, Pew-Thian Yap
Affiliation: University of North Carolina at Chapel Hill, Huaqiao University
Abstract Preview: Purpose: Unsupervised CBCT-to-CT translation in the pelvic region is essential for accurate radiotherapy delivery and adaptive image-guided interventions. However, current models for cross-modality tr...
Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens
Affiliation: Ghent University, Ghent University Hospital
Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...
Authors: Derek Tang, Susu Yan
Affiliation: Massachusetts General Hospital
Abstract Preview: Purpose: To evaluate the performance of a multi-task automated-segmentation and synthetic CT generation model (sCT) and investigate its application in an adaptive proton therapy workflow.
Methods: ...
Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai
Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel cameraābased eyeātracking system to provide real-time noninvasive eye positioni...
Authors: Beth Bradshaw Ghavidel, Chih-Wei Chang, Yuan Gao, Priyanka Kapoor, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Jill Remick, Justin R. Roper, Zhen Tian, Xiaofeng Yang
Affiliation: Whinship Cancer Institute, Emory University, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Current cone-beam computed tomography (CBCT) typically requires no less than 200 degrees of angular projections, which prolongs scanning time and increases radiation exposure. To address thes...
Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To design a 3D printed insert for Varianās SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...
Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...
Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patientās nose relative to two stationary reflectors on th...
Authors: Mohammed Alzaabi, Owen Thomas Dillon, Julia Johnson, Andrew Kanawati, Tess Reynolds, Ann Yan
Affiliation: Westmead Hospital, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Khalifa University
Abstract Preview: Purpose: To develop a physiological carotid artery phantom and Bayesian geometric calibration method to examine the feasibility of extended field-of-view interventional CBCT artery imaging using a mul...
Authors: Kaelyn Becker, Xenia Ray
Affiliation: University of California, San Diego, University of California San Diego
Abstract Preview: Purpose: Ethos 2.0 with HyperSight (Varian Medical Systems) imaging enables nearly fully automated offline adaptive radiotherapy including automated deformation of targets and recalculation on the Hou...
Authors: Yaowen Cao, Yunwen Huang, Yidong Yang, Xiaogang Yuan, Ning Zhao, Cheng Zheng
Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose: MRI has better soft tissue contrast than cone beam CT which is commonly used in image guided radiotherapy. This study aims to develop a low-field MRI system for precision small animal radiati...
Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...
Authors: Michael J. Choi, Vindu Wathsala Kathriarachchi, Christopher L. Nelson, Andrew P. Soderstrom, Yawei Zhang
Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, UF Health Proton Therapy Institute
Abstract Preview: Purpose: Cone Beam Computed Tomography (CBCT) is widely used in image-guided radiation therapy for patient positioning. While kV photons offer high image contrast, they are prone to artifacts caused b...
Authors: Xiaoyi Dai, Manju Liu, Weiwei Sang, Pulin Sun, Fan Xia, Zhenyu Yang, Fang-Fang Yin, Chulong Zhang, Rihui Zhang
Affiliation: Jiahui International Hospital, Radiation Oncology, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
Current deep learning-based sparse-view CBCT reconstruction methods are prone to hallucinatory artifacts, as they rely on inferred image details that may not correspond to true anatomical ...
Authors: Daniel H. Bushe, Arthur Lalonde, Hoyeon Lee, Harald Paganetti, Brian Winey
Affiliation: Universite de Montreal, Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School, University of Hong Kong
Abstract Preview: Purpose: Improving the precision and fidelity of daily volumetric imaging is essential for enabling adaptive proton therapy (APT). While cone-beam CT (CBCT) provides daily volumetric imaging, their ut...
Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yabo Fu, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Boris Mueller, Huiqiao Xie, Mitchell Yu, Hao Zhang
Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Gating ablative radiotherapy for pancreatic cancer accounts for tumor movement due to respiration and typically requires 5, 15, or 25 fractions. Pretreatment imaging verification is essential...
Authors: Nan Li, Yaoying Liu, Shouping Xu, Gaolong Zhang
Affiliation: Department of Radiation Oncology, School of Physics, Beihang University, School of physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: In intensity-modulated proton therapy (IMPT) for head and neck cancer, CBCT registration ensures accurate setup, minimizing dose errors. Unlike IMRT, IMPT plans directly define tumor volumes ...
Authors: Jongduk Baek, Jooho Lee, Adam S. Wang
Affiliation: Stanford University, Yonsei University
Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...
Authors: Lei Ren, Jie Zhang
Affiliation: University of Maryland School of Medicine
Abstract Preview: Purpose: 4D-CBCT is valuable for imaging anatomy affected by respiratory motions to guide radiotherapy delivery. However, 4D-CBCT often has undersampled projections acquired in each respiratory phase ...
Authors: Hassan Bagher-Ebadian, Justine M. Cunningham, Anthony J. Doemer, Mohammad M. Ghassemi, Joshua P. Kim, Benjamin Movsas, Kundan S Thind
Affiliation: Michigan State University, Henry Ford Health
Abstract Preview: Purpose: Reduction of noise in medical images critically enables improved accuracy in delineating tumors and organs at risk, leading to more precise treatment planning and safer image-guided radiation...
Authors: Rashmi Bhaskara, Oluwaseyi Oderinde
Affiliation: Purdue University
Abstract Preview: Purpose: This study proposes a novel approach to overcoming CBCT image quality limitations by developing an improved synthetic CT (sCT) generation method based on a CycleGAN architecture using Vision ...
Authors: Sarah Burleson, Antonio L. Damato, Yabo Fu, Laura Happersett, Tianfang Li, Xiang Li, Himanshu Nagar, Pengpeng Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: An iodinated hydrogel perirectal spacer, injected between the prostate and rectum, reduces rectal high-dose exposure during prostate SBRT. We assessed the feasibility of tracking the spacer a...
Authors: Eenas A. Omari
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: N/A...
Authors: Maria de la Luz De Ornelas, Yunze Yang
Affiliation: University of Miami
Abstract Preview: Purpose:
An extended Winston-Lutz test (EWL), also known as off-axis Winston-Lutz, was performed to assess the linear acceleratorās (linac) deviations at isocenter and five off-iso targets. The imp...
Authors: Rashmi Benda, Qinghao Chen, Shifeng Chen, Giovanni Lasio, Peter Olivieri, Huijun Xu, Junliang Xu, Byong Yong Yi, Baoshe Zhang, Jinghao Zhou
Affiliation: University of Maryland Baltimore Washington Medical Group, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center
Abstract Preview: Purpose:
We investigated if the patients receiving lung stereotactic body radiation therapy (SBRT) have adequate planning target volume (PTV) margins by evaluating the intrafraction motion using a ...
Authors: Yi-Fang Wang, Yading Yuan
Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center
Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...
Authors: Neha Devi, Deon M. Dick
Affiliation: Jaeger Corporation
Abstract Preview: Purpose: To evaluate the impact of bladder volume variation on small bowel dose in prostate cancer patients with nodal involvement and assess the efficacy of a 'half-full bladder' guideline for minimi...
Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao
Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospitalļ¼ Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patientsā daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...
Authors: Fan Liu, Adam C. Riegel, Yi-Fang Wang
Affiliation: Columbia University Irving Medical Center
Abstract Preview: Purpose: HyperSight, Varian Medical Systems' latest CBCT technology, integrates rapid 6-second data acquisition with advanced iterative reconstruction, enabling precise real-time contouring and dose c...
Authors: Cem Altunbas, Farhang Bayat, Roy Bliley, Brian Kavanagh, Uttam Pyakurel, Tyler Robin, Ryan Sabounchi
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic
Abstract Preview: Purpose: The use of image features extracted from serial CBCT images to assess radiotherapy response and toxicity is an active research area. However, poor image quality often compromises reliability ...
Authors: Kuan Ling Chen, Jiajin Fan, Maduka M. Kaluarachchi, Wei Nie
Affiliation: Inova Schar Cancer Institute
Abstract Preview: Purpose: This study evaluates the impact of CBCT acquisition speed on the accuracy of moving target alignment during image-guided radiotherapy. Additionally, the influence of target motion speed and r...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...
Authors: Yijian Cao, Jenghwa Chang, Lyu Huang
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose: This study evaluates the treatment delivery efficiency and workflow of two advanced linear accelerator systemsāVarianās TrueBeam (C-arm) and Halcyon (O-ring)āfor prostate Stereotactic Body Ra...
Authors: Laura Bennett, Matthew Charles, Greg Cooley, John M. Floberg, Ryan Hutten, Elissa Khoudary, Nicholas Lynch, Kaili Ranta, Jordan M. Slagowski, Trevor Wilson
Affiliation: University of Pennsylvania, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, University of Wisconsin-Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: To evaluate the impact of an iterative cone beam CT with metal artifact reduction (iCBCT+MAR) reconstruction algorithm (HyperSight TrueBeam 4.1, Varian Medical Systems) on image quality and s...
Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina
Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.
Methods: Dose calculations in water phan...
Authors: Michelle Alonso-Basanta, Joshua Bryer, Lei Dong, Barbara Garcia, Elissa Khoudary, Brandon M. Koger, Taoran Li, Michael Salerno, Karen Tang, Boon-Keng Kevin Teo
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: The Varian HyperSight imaging solution features a workflow for planning on CBCT images (CBCTp). This study evaluates the feasibility of CBCTp images in the setting of an offline adaptive plan...
Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna
Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI
Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...
Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert
Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis
Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...
Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang
Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center
Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...
Authors: Sofia Beer, Menal Bhandari, Alec Block, Nader Darwish, Joseph Dingillo, Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Rajkumar Kettimuthu, Jason Patrick Luce, Ha Nguyen, John C. Roeske, George K. Thiruvathukal, Austin Yunker
Affiliation: Data Science and Learning Division, Argonne National Laboratory, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Computer Science, Loyola University of Chicago
Abstract Preview: Purpose: Artificial intelligence (AI) generated synthetic medical images are seeing increased use in radiology and radiation oncology. Physician observer studies are an ideal way to evaluate the usabi...
Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...
Authors: Hacene Azizi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Mohamed Lamine Seghier
Affiliation: Khalifa University Biomedical Engineering & Biotechnology, Laboratory of dosing, analysis and characterization in high resolution, Ferhat Abbas Setif 1 University, Khalifa University Physics Department, Khalifa University
Abstract Preview: Purpose:
To ensure accurate alignment of cone-beam computed tomography (CBCT) and computed tomography (CT) images for image-guided radiotherapy, this study evaluates a foundation model guidance fra...
Authors: Kwang-Ho Cheong, Seungryong Cho, Joonil Hwang, Jae Won Jung, Hoyeon Lee, Raymond Hyunwoo Moon, Inhwan Yeo, Jihyung Yoon
Affiliation: East Carolina University, INOVA Schar Cancer Institute, University of Hong Kong, Hanllym University, KAIST, University of Rochester
Abstract Preview: Purpose: Monitoring a target and neighboring organs during beam delivery is crucial for successful radiotherapy (RT). Conventional transit imaging methods lack volumetric reconstruction capabilities, ...
Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Womenās Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute
Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...
Authors: Xiang Li
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: N/A...
Authors: Varsha Jain, Jun Kang, Paul Sulivan, Kate E. Verma, Yevgeniy Vinogradskiy
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose:
Patients undergoing treatment for head and neck(H&N) cancers experience significant body contour changes throughout treatment. Body contour changes are due to tumor shrinkage, weight loss,...
Authors: Manju Liu, Weiwei Sang, Yanyan Shi, Zhenyu Yang, Fang-Fang Yin, Chulong Zhang, Lihua Zhang, Rihui Zhang
Affiliation: Jiahui International Hospital, Jiahui International Hospital, Radiation Oncology, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: This study aims to transform cone-beam computed tomography (CBCT) images acquired from deep inspiration breath-hold (DIBH) breast cancer patients into high-fidelity synthetic CT (sCT) images....
Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello
Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham
Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...
Authors: So Hyun Ahn, Chris Beltran, Byongsu Choi, Jeong Heon Kim, Jin Sung Kim, Bo Lu, Justin Chunjoo Park, Bongyong Song, Jun Tan
Affiliation: Mayo Clinic, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Ewha Medical Research Institute, Ewha Womans University College of Medicine, UC San Diego, Yonsei University College of Medicine
Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) is widely used in IGRT for patient positioning but suffers from low resolution and poor soft tissue contrast. Synthetic CT (sCT) generated from CBCT ad...
Authors: Yu Gao, Lei Xing, Siqi Ye
Affiliation: Department of Radiation Oncology, Stanford University
Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) scans are often the only option for non-coplanar radiation therapy to prevent potential mechanical collisions. However, the consecutive angular occlusion of pr...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: This study introduces a novel spatiotemporal Gaussian neural representation framework to reconstruct high-temporal dynamic CBCT images from 1-minute acquisition, preserving motion dynamics an...
Authors: Cheryl Anderson, Lara Best, Amanda Cherpak, Jennifer DeGiobbi, Marc C. LeBlanc, R. Lee MacDonald, Peter R. Martin, Natasha McMaster, Murali Rajaraman, James L. Robar, Lucy Ward, Derek Wilke, Kenny Zhan
Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health
Abstract Preview: Purpose: This work investigates the potential benefit of adaptive planning using the Ethos radiotherapy system (Varian Medical Systems) with direct-dose calculation on HyperSight cone beam CT (CBCT) f...
Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC
Abstract Preview: Purpose: The goal of the HyperSightĀ® offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...
Authors: James M. Lamb, Dishane Chand Luximon, Jack Neylon, Rachel Petragallo, Moritz Ritter, Timothy Ritter
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, ETH Zurich, VCU Health System, Department of Radiation Oncology, University of Colorado
Abstract Preview: Purpose: Anomalies in cone beam computed tomography (CBCT) radiotherapy image guidance can signal treatment deviations. Repetitive review of setup image registrations by humans is inefficient, prone t...
Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
It has been challenging to acquire clinically useful MR images of pediatric cancer patients without anesthesia, and MR contrast agents. Custom-made immobilization devices and optimization ...
Authors: Anthony J. Doemer, Aharon Feldman, Ian Gallagher, Yimei Huang, Brett M. Miller, Benjamin Movsas, Kundan S Thind
Affiliation: Henry Ford Health
Abstract Preview: Purpose: CT-guided adaptive radiation therapy (CTgART) is a technical, resource intensive, procedure that involves many different radiation oncology team members. To ensure consistent, high-quality CT...
Authors: Samuel L. Brady, Kevin Chen, Joseph G. Meier
Affiliation: University of Cincinnati, Cincinnati Childrens Hospital Med Ctr
Abstract Preview: Purpose: Conebeam-CT (CBCT) acquisition protocols typically do not distinguish between adults and pediatrics. In collaboration with a fluoroscopically-guided interventional (FGI) manufacturer, new, do...
Authors: Mahya Ahmadzadeh, Nagarajan Kandasamy, Keyur Shah, Gregory C. Sharp, Santhosh Vadivel, John MacLaren Walsh
Affiliation: Electrical and Computer Engineering Department, Massachusetts General Hospital, Emory University, Drexel University
Abstract Preview: Purpose: In image-guided radiotherapy (IGRT), cone beam CTs (CBCTs) suffer from distortions that degrade registration with planning CTs. While CycleGANs can generate synthetic CTs (sCTs) from CBCTs, e...
Authors: Seungryong Cho, Donghyeok Choi, Joonil Hwang, Byung-Hee Kang, Jin Sung Kim, Eungman Lee, Younghee Park
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, KAIST, Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Ewha Womans University of Medicine
Abstract Preview: Purpose: Radiation therapy (RT) is critical for cancer treatment, but changes in tumor size and shape during therapy challenge precise dose delivery. Adaptive radiation therapy (ART) addresses these v...
Authors: Anthony J. Doemer, Aharon Feldman, Stephen J. Gardner, Brett M. Miller, Benjamin Movsas, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia
Affiliation: Henry Ford Health
Abstract Preview: Purpose: To evaluate the efficacy of calculation-only approach for CIED risk-level assessment.
Methods: A total of 86 patients were included in this retrospective analysis. For each patient, in viv...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Christian Erik Petersen, Alex T. Price, Atefeh Rezaei, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: CBCT is subject to more artifacts due to increased photon scatter, especially in areas of increased tissue heterogeneities compared to fan-beam CTs (FBCTs). Improved imaging panels combined w...
Authors: Wendy Siman, Wei Zhou
Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine
Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-µm tungsten wire was imaged at ...
Authors: James M. Balter, Alexander Moncion, Ikechi S Ozoemelam
Affiliation: University of Michigan
Abstract Preview: Purpose: Sequential dual-energy cone beam computed tomography (DE-CBCT) integrated with an online adaptive platform could potentially improve soft tissue visualization for more accurate anatomical del...
Authors: Wookjin Choi, James M. Lamb, David Romanofski, David H. Thomas, Yevgeniy Vinogradskiy
Affiliation: Drexel, Department of Radiation Oncology, University of California, Los Angeles, Thomas Jefferson University
Abstract Preview: Purpose: To develop an intelligent Black Box Recorder for radiation therapy (RT) that monitors patient treatments using a vision language model.
Methods: The system captures synchronized screen rec...
Authors: Bin Cai, Andrew R. Godley, Brian A. Hrycushko, Heejung Kim, Mu-han Lin, David D.M. Parsons, Justin D. Visak, Da Wang, Tingliang Zhuang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: The standard radiation therapy workflow requires CT-simulation and planning, whether for initial treatments or re-planning due to significant anatomical changes. IPART instead uses one patien...
Authors: Saree Alnaghy, Owen Thomas Dillon, Sean P Hood, Paul J. Keall, Ricky O'Brien, Tess Reynolds
Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney, University of Wollongong, Medical Radiations, School of Health and Biomedical Sciences, RMIT University
Abstract Preview: Purpose: Photon Counting Detectors (PCDs) have been demonstrated to improve resolution, contrast and lesion detectability in fan-beam CT. There is naturally a desire to bring these improvements to Con...
Authors: Wesley A. Belcher, Robert A. Corns, Jae Won Jung, Matthew S Peach, Swarup Sharma
Affiliation: The University of North Carolina at Chapel Hill, East Carolina University Brody School of Medicine
Abstract Preview: Purpose: GammaTiles are a novel intracranial brachytherapy approach designed to directly deliver radiation therapy to residual or recurrent brain tumors following resection. Despite their promising th...
Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University
Abstract Preview: Purpose: Gantry motion and patient breathing during a breast cone beam CT (bCBCT) scan is one of the major challenges for microcalcification (μCalcs) detection. By deploying a large number of individu...
Authors: Harald Keller, Iymad Mansour, Jeff D. Winter
Affiliation: Princess Margaret Cancer Centre
Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...
Authors: Liu Hong, Zhong Su
Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)
Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...
Authors: Hania A. Al-Hallaq, Duncan Henry Bohannon, Chih-Wei Chang, Anees H. Dhabaan, Vishal Dhere, H Scott McGinnis, Pretesh Patel, Sagar Patel, Keyur Shah, Xiaofeng Yang, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Two-fraction proton SABR is an attractive alternative to brachytherapy for localized prostate cancer. However, potential interfractional anatomical changes necessitate online adaptation, espe...
Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University
Abstract Preview: Purpose: Contrast-enhanced breast cone-beam computed tomography (bCBCT) provides high-resolution, 3D imaging of breast tissues with improved differentiation between normal and abnormal tissues. Curren...
Authors: Neal Andruska, Lianna D. DiMaso-Myers
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: To provide details on how our clinic assesses respiratory motion during treatment of a pancreatic adenocarcinoma during dose escalated radiation therapy on a linear accelerator with the aid o...
Authors: Awens Alphonse, Nebi Demez, Brian P. Laffey, Shyam Pokharel, Suresh Rana, Nishan Shrestha
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: The Imaging Ring is a mobile digital X-ray system capable of producing 2D planar X-rays, fluoroscopy, and 3D Cone-Beam Computed Tomography (CBCT) images. This study aimed to evaluate the long...
Authors: Won Chang, Vadim L. Stakhursky, Yevgeniy Vinogradskiy
Affiliation: Jefferson Einstein, Alliance Cancer Specialists, Thomas Jefferson University
Abstract Preview: Purpose: 4DCBCT is a powerful tool for localization of moving targets when treating lung tumors with hypofractionated regimens (SBRT). However, for patients with implanted cardiac devices (ICD) in clo...
Authors: Alyssa Capizzi, John J Dombrowski, Nabil N. Khater
Affiliation: Saint Louis University
Abstract Preview: Purpose: To evaluate a mask-less adaptable headrest (MAHR) prototype for head-and-neck IMRT designed to reduce random and systematic shifts of patientsā setups. MAHR complements current image-guidance...
Authors: Ziqi Gao, Lei Xing, Siqi Ye, S. Kevin Zhou
Affiliation: Department of Radiation Oncology, Stanford University, University of Science and Technology of China (USTC)
Abstract Preview: Purpose: To address the challenge of high memory usage in volumetric cone-beam CT (CBCT) imaging, we propose a method that combines joint reconstruction and super-resolution for sparsely sampled CBCT ...
Authors: Gregory J Bootsma, Tunok Mondol
Affiliation: University Health Network, Princess Margaret Cancer Center
Abstract Preview: Purpose:
To evaluate the impact of prototype fluence field modulation (FFM) cone-beam CT (CBCT) on dose reduction and image quality using Monte Carlo simulations. This study particularly looks at t...
Authors: Ming Chao, Thomas Chum, Tenzin Kunkyab, Yang Lei, Tian Liu, Richard G Stock, Hasan Wazir, Junyi Xia, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose:
This study aims to develop effective strategies for multi-organ segmentation of pelvic cone-beam computed tomography (CBCT) images based on transformer models to facilitate adaptive radiat...
Authors: Jia Wang, Vani Yadav
Affiliation: Stanford University
Abstract Preview: Purpose: To evaluate the radiation dose and imaging quality of two novel CBCT X-Ray imaging systems used in spine surgeries.
Methods: CBCT scan of ACR CT and CTDI phantoms was performed to acquire ...
Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania
Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...
Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna
Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI
Abstract Preview: Purpose: To estimate effective doses associated with different imaging protocols for hip imaging with a cone beam CT (CBCT) scanner specifically designed for weight-bearing acquisitions.
Methods: A...
Authors: Chih-Wei Chang, Junbo Peng, Richard L.J. Qiu, Justin Roper, Xiangyang Tang, Tonghe Wang, Huiqiao Xie, Xiaofeng Yang, David Yu
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Emory Univ, Emory University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered a promising solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, ...
Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske
Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago
Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...
Authors: Anthony J. Doemer, Ian Gallagher, Yimei Huang, Jeff A. Riess, Kundan S Thind, Bo Zhao
Affiliation: Henry Ford Health
Abstract Preview: Purpose: Stereotactic body radiation therapy (SBRT) is commonly used for early-stage lung cancer. While pre-treatment CT captures some tumor motion, it may not fully represent intra-fraction motion du...
Authors: Panagiotis Iliopoulos, Marios Myronakis, Kyriaki Theodorou
Affiliation: Medical Physics Department, Medical School, University of Thessaly
Abstract Preview: Purpose: To estimate individualized absorbed dose at Organs at Risk (OARs) from kV Cone Beam CT (CBCT) imaging in the pelvic area, prior radiotherapy, and assess excess risk for secondary malignancies...
Authors: Jian Chen, Qiufen Guo, Aihua Li, Jing Liu, Junjie MA, Qian WU, Haonan Xiao, Peng Xie, Xiaohui Yan, Yong Yin, Zhe Zhang
Affiliation: Department of Radiation Oncology, Peking University Shenzhen Hospital, Department of Radiation Oncology and Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Obstetrics and Gynaecology, Liao Cheng Peopleās Hospital
Abstract Preview: Purpose: Online Adaptive radiation therapy (ART) has been an effective technique to manage patientās inter-fractional anatomical changes and therefore reduces planning target volume (PTV). However, on...
Authors: Issra Rashed, Jennie Wilder, Jingeng Zhu
Affiliation: Rush Riverside Cancer Institute, Advanced Oncology Solutions (AOS) Varian, a Siemens Healthineers company
Abstract Preview: Purpose: Develop a method to plan and deliver homogeneous dose to Craniospinal(CS) irradiation on Linear Accelerator.
Methods: Three treatment planning volumes (PTV) are created in sequence from su...
Authors: Leslie Harrell, Sanjay Maraboyina, Romy Megahed, Maida Ranjbar, Xenia Ray, Pouya Sabouri
Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), University of California San Diego
Abstract Preview: Purpose: Real-time adaptive radiation therapy (ART) dynamically modifies patientsā treatment plan during delivery to account for anatomical and physiological variations. Addressing ART planning time v...
Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu
Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health
Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...
Authors: Hua-Chieh Shao, You Zhang, Ruizhi Zuo
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cone-beam CT (CBCT) provides on-board patient anatomy for image guidance and treatment adaptation in radiotherapy. However, to compensate for respiration-induced anatomical motion, motion-res...
Authors: Hua-Chieh Shao, Guoping Xu, You Zhang, Tingliang Zhuang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Advancements in onboard X-ray hardware allow high-quality CBCT imaging with a short scan time (~6s for Varian HyperSight), enabling CBCT-based dose calculation and treatment planning. Howe...
Authors: Yussuf A. Abdelal, Junguo Bian, Michael Delafuente, Sebastien A. Gros, Hyejoo Kang, Luke Layman, M Mahesh, John C. Roeske
Affiliation: Department of Radiology and Medical Imaging, Stritch School of Medicine, Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Johns Hopkins Univ
Abstract Preview: Purpose: This study evaluates the feasibility of optimizing 4DCBCT imaging protocols for gated lung SBRT, by reducing dose while maintaining the image quality required for accurate patient alignment.<...
Authors: Jing Wang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: N/A...
Authors: Jiahao Chen, Yunwen Huang, Yidong Yang, Shanshan Zhang, Ning Zhao, Cheng Zheng
Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose: To develop a molecular image-guided radiotherapy technique for accurate and effective radiation treatment using quantitative fluorescence molecular tomography (FMT).
Methods: X-ray cone be...
Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu
Affiliation: Mayo Clinic
Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)
Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...
Authors: Guilherme Rosa Ferreira, Dan Giardina, John Karageorgiou, Chris Malone, Allan Thomas
Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine
Abstract Preview: Purpose: Radiation segmentectomy has become a primary strategy in 90Y radioembolization, with localized treated volumes that can include up to two liver segments. The goal is complete pathological nec...
Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina
Abstract Preview: Purpose:
To calculate radiobiological metrics of daily dose delivered for head and neck (HN) patients using the daily cone beam CT (CBCT) to generate a pseudo CT (pCT). Moreover, this work compares...
Authors: Hania A. Al-Hallaq, Chih-Wei Chang, Anees H. Dhabaan, Yuan Gao, Shaoyan Pan, Junbo Peng, Richard L.J. Qiu, Keyur Shah, Sibo Tian, Zhen Tian, Xiaofeng Yang, David Yu, Jun Zhou
Affiliation: Emory University, Whinship Cancer Institute, Emory University, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Traditional cone-beam computed tomography (CBCT) often requires multiple angular projections, increasing radiation exposure and extending scanning times, which may lead to heightened patient ...
Authors: Francis A Asamoah, David D. Campos, Jordan A Holmes, Ke Colin Huang, Omar Ishaq, Sook Kien Ng, Arpan Prabhu, Edwin Quashie, Yong Yue
Affiliation: Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Evaluate a novel rectal spacer workflow with spacer injection during brachytherapy to streamline logistics, reduce hospital visits and costs, and compare the benefits of SpaceOAR Vue and Barr...
Authors: Weixing Cai, Laura I. Cervino, Qiyong Fan, Yabo Fu, Tianfang Li, Xiang Li, Jean M. Moran, Hai Pham, Pengpeng Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: AAPM Task Group Report 273 emphasizes the importance of rigorous validation to ensure the generalizability and robustness of machine learning-based clinical tools before their implementation ...
Authors: Lili Chen, Xiaoming Chen, Chang Ming Charlie Ma, Joshua Meyer
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Fast CBCT (HyperSight) acquisition technique together with a surface-guided breath-hold (SGBH) would allow a better image quality for accurate target/organ delineation. It facilitates breath-...
Authors: Daming LI, Jinsen Xie, Zhe Zhang
Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China
Abstract Preview: Purpose: To analyze the actual doses received during radiotherapy for head and neck cancers (HNC) using Velocity, providing insights for adaptive radiotherapy decision-making.
Methods: Thirty-three...
Authors: Nina Burbure, Tawfik G. Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang
Affiliation: FCCC at Temple University Hospital
Abstract Preview: Purpose: Frameless gamma knife (GK) treatments use a thermoplastic mask coupled with high-definition motion management system that utilizes an infrared camera, and a reflective marker placed on the pa...
Authors: Geoffrey D. Hugo, Eric Laugeman, Thomas R. Mazur, Pamela Samson, Kim A. Selting, Zhehao Zhang
Affiliation: University of Illinois, Washington University in St. Louis School of Medicine, WashU Medicine
Abstract Preview: Purpose: To investigate the robustness of a deep learning (DL)-based 4D-CBCT motion-compensated (MoCo) reconstruction method to out-of-distribution data.
Methods: Our developed 4D-CBCT reconstructi...
Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang
Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...
Authors: Yi Rong
Affiliation: Mayo Clinic Arizona
Abstract Preview: N/A...
Authors: Hua-Chieh Shao, Shanshan Tang, Jing Wang, Kai Wang, You Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, University of Maryland Medical Center
Abstract Preview: Purpose: Artifacts caused by gas bubble movement in the gastrointestinal tract can severely degrade the image quality of on-board abdominal cone-beam computed tomography (CBCT), impacting its utility ...
Authors: Karam Ayoub, Aaron B Hesselson, Ronald C McGarry, Joshua Misa, Damodar Pokhrel
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Cardiology
Abstract Preview: Purpose: Noninvasive stereotactic body radiosurgery (SBRS) is emerging treatment option for advanced heart failure patients with refractory-ventricular tachycardia (rVT) who experienced recurrent impl...
Authors: Lori Buchholtz, Alison Garda, Chris L. Hallemeier, Kathryn L. Kolsky, Han Liu, Joseph John Lucido, Marisa Schinter, Andrew J. Veres, Sara Walerak
Affiliation: Mayo Clinic
Abstract Preview: Purpose: The C_START initiative aims to streamline and simplify the Direct-to-Unit (DtU) clinical setup and treatment planning process for photon radiation therapy, particularly for emergent cases suc...
Authors: Hoyeon Lee
Affiliation: University of Hong Kong
Abstract Preview: Purpose: Deep-learning approaches are widely investigated for Cone-Beam CT (CBCT) scatter correction to improve the quality of the linear-accelerator mounted CBCT. This study aims to optimize the deep...
Authors: Cem Altunbas, Adam Avant, Farhang Bayat, Roy Bliley, Ian Boor, Brian Kavanagh, Uttam Pyakurel, Tyler Robin, Ryan Sabounchi
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic
Abstract Preview: Purpose: Improved soft tissue visualization plays an important role in target localization and treatment plan adaptation in CBCT-guided radiotherapy. In this work, a novel CBCT approach, 2D antiscatte...
Authors: Liang-Hsin Chen, Li-Chien Wei
Affiliation: National Taiwan University Cancer Center
Abstract Preview: Purpose: For proton therapy treatment, it is essential to ensure that the treatments are delivered safely and accurately. Quality assurance (QA) programs of proton treatment system is needed and proto...
Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang
Affiliation: The University of Chicago
Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...
Authors: Michael Cummings, Olga M. Dona Lemus, Hana Mekdash, Tyler Moran, Alexander R Podgorsak, Sean M. Tanny, Matthew J. Webster, Lexiang Yang, Dandan Zheng, Yuwei Zhou, Xiaofeng Zhu
Affiliation: Department of Radiation Oncology, University of Rochester, University of Miami, Inova Schar Cancer Institute, University of Rochester
Abstract Preview: Purpose: oART is revolutionizing radiotherapy by allowing treatment plans to be adjusted based on daily imaging, improving targeting precision and potentially enhancing patient outcomes. However, its ...
Authors: Anthony J. Doemer, Bing Luo, Benjamin Movsas, Humza Nusrat, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia
Affiliation: Department of Physics, Toronto Metropolitan University, Henry Ford Health
Abstract Preview: Purpose: Large-vision models (LVMs) are rapidly emerging, yet their application in radiation oncology remains largely unexplored. This study investigates the potential of LVMs for offline adaptive rad...
Authors: Bin Cai
Affiliation: University of Texas Southwestern Medical Center
Abstract Preview: N/A...
Authors: Owen Thomas Dillon, Andrew Kanawati, Tess Reynolds
Affiliation: Westmead Hospital, Image X Institute, Faculty of Medicine and Health, The University of Sydney
Abstract Preview: Purpose: Metal artefacts from implanted hardware and surgical tools remain a limitation for widespread adoption of intraoperative CBCT imaging. Gantry-based non-circular imaging trajectories have emer...
Authors: Guangjun Li, Ying Song, Huanan Tang, Tianxiong Wu, Qiuyi Ye, Wei Zhang
Affiliation: West China Second Hospital of Sichuan University, United Imaging Healthcare, West China Hospital of Sichuan University
Abstract Preview: Purpose:
To propose a general low-dose reconstruction model for ultra-sparse-view cone-beam CT (CBCT) and evaluate its clinical application in improving image quality and reducing radiation dose fo...
Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.
Methods: CT and CBCT images from 65 abdominal pat...
Authors: Joseph A. Miccio, Nicholas J. Potter, Zain Siddiqui
Affiliation: Penn State Health Milton S. Hershey Medical Center
Abstract Preview: Purpose: Fiducial markers are the gold standard for prostate alignment during CT-based image-guided radiotherapy (IGRT). Radiopaque hydrogel rectal spacers reduce rectal toxicity by displacing the rec...
Authors: Yi An, David J. Carlson, Zhe (Jay) Chen, Jun Deng, Dae Yup Han, Sameer Taneja
Affiliation: Yale School of Medicine, Yale University School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: Spine Stereotactic radiosurgery (SSR) delivers a large radiation dose and utilizes narrow PTV margins, on the order of 1 mm, to avoid excess dose to the spinal cord. Because of this, intrafra...
Authors: Minsong Cao, Amar Kishan, Dylan P. O'Connell, Jonathan Pham, Michael Steinberg, Luca F Valle, Michael Xiang
Affiliation: Department of Radiation Oncology, University of California, Los Angeles
Abstract Preview: Purpose: To evaluate bladder ultrasound as a surrogate for estimating on-table bladder volume in prostate cancer patients undergoing stereotactic body radiation therapy (SBRT). The study aimed to asse...
Authors: Matthew C Abramowitz, Alan Dal Pra, Rodrigo Delgadillo, Nesrin Dogan, John C. Ford, Kyle R. Padgett, Levent Sensoy, Benjamin Spieler, Matthew T. Studenski, Jace Allen Walker
Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, University of Miami School of Medicine
Abstract Preview: Purpose:
Toxicities that affect a patientās quality-of-life due to prostate cancer (pCa) radiation therapy (RT) are receiving more attention as RT has become increasingly successful in treating pCA...
Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray
Affiliation: University of California San Diego
Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...
Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant
Affiliation: St. Jude Children's Research Hospital
Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...
Authors: Steve B. Jiang, Ruiqi Li, Hua-Chieh Shao, Kenneth Westover, You Zhang, Tingliang Zhuang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Respiratory motion is a long-standing challenge for lung SBRT, particularly for centrally-located lung tumors where increased toxicity demands more precise motion management during treatme...