A Comparison of Non-Adaptive Versus Online Adaptive Radiotherapy for Prostate Cancer Using FLOW-RT-- Fast, AI-Driven but Learning-Enabled, Online Adaptive Workflow for Radiotherapy

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Angela Jia, Rojano Kashani, Kyle O'Carroll, Alex T. Price, Adithya Reddy, Atefeh Rezaei, Daniel E Spratt, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To evaluate the effect of unedited AI-generated contours used for online adaptive radiotherapy (FLOW-ART) on the plan quality of prostate treatments as compared to non-adaptive (non-ART) proc...

A Comparison of the Impact to Mean Doses to Organs at Risk of Small Versus Large Spot Sizes in Pelvic Proton Therapy

Authors: Jamie s Baker, Sam Beddar, Mahsa Dehghanpour, Ariel MT Hoang, Emma Holliday, Rachael M. Martin Paulpeter, Joshua S. Niedzielski, Luis Augusto Perles, Josie S Ruzek, Gabriel O. Sawakuchi

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, niversity of Texas MD Anderson Cancer Center School of Health Professions, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, University of Texas MD Anderson Cancer Center School of Health Professions

Abstract Preview: Purpose: This study aims to evaluate the dosimetric impact on organs at risk (OAR) of small versus large spot sizes when treating pelvic cancer patients with pencil beam scanning (PBS) proton therapy....

A New Voxel-Based Similarity Approach for Assessing Contour Similarity and Clinical Dosimetric Effect

Authors: Shari Damast, Svetlana Kuznetsova, Christopher J. Tien

Affiliation: Yale University School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Current contour similarity evaluation approaches (Dice Similarity Coefficient, Mean Distance to Agreement) are limited to geometric agreement without assessment of ultimate dosimetric impact....

A Novel Optimization Algorithm That Improves DVH Based Planning for Direction Modulated Brachytherapy Tandem Applicator.

Authors: Christopher L. Deufel, Suman Gautam, William Y. Song

Affiliation: Virginia Commonwealth University, Mayo Clinic

Abstract Preview: Purpose: Direction modulated brachytherapy creates anisotropic dose distribution from an isotropic source. This study aims to develop a truncated conditional value at risk optimization algorithm for D...

Dosimetric Impact of Adaptive Radiotherapy with Ethos for Prostate Cancer: Localized Analysis of Bladder and Rectum across Planned, Non-Adaptive Accumulated, and Adapted Treatments

Authors: Huisi Ai, Scott Glaser, Yi Lao, Percy Lee, Sara N. Lim, An Liu, Bo Liu, Borna Maraghechi, Kun Qing, Chengyu Shi, William T. Watkins, Terence Williams, Qiuyun Xu, Jiahua Zhu

Affiliation: WashU Medicine, Graduate Program in Bioengineering, University of California San Francisco-UC Berkeley, City of Hope Orange County, Department of Radiation Oncology, City of Hope National Medical Center, Department of Radiation Oncology, City of Hope Orange County, Department of Radiation Oncology, City of Hope Medical Center

Abstract Preview: Purpose: To employ a novel surface dose mapping approach for localized assessment of the dosimetric impact of Ethos adaptive radiotherapy (ART) for prostate cancer (PC).
Methods: This study include...

Evaluating the Impact of Bladder Volume on Small Bowel Dose Constraints in Prostate Cancer Patients with Nodal Involvement: Assessing the Efficacy of a 'half-Full Bladder' Guideline

Authors: Neha Devi, Deon M. Dick

Affiliation: Jaeger Corporation

Abstract Preview: Purpose: To evaluate the impact of bladder volume variation on small bowel dose in prostate cancer patients with nodal involvement and assess the efficacy of a 'half-full bladder' guideline for minimi...

Evaluating the Impact of Spot Spacing on Dosimetric Outcomes in Dynamic Arc Proton Therapy for Prostate SBRT

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Umesh Rana, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: DynamicARC is a novel pencil beam scanning (PBS) proton therapy technique with the potential to provide more conformal dose distributions and reduce treatment time. This study investigates th...

Evaluation of Radiomic Feature Robustness in Quantitative CBCT Imaging for Radiotherapy of Prostate Cancer

Authors: Cem Altunbas, Farhang Bayat, Roy Bliley, Brian Kavanagh, Uttam Pyakurel, Tyler Robin, Ryan Sabounchi

Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic

Abstract Preview: Purpose: The use of image features extracted from serial CBCT images to assess radiotherapy response and toxicity is an active research area. However, poor image quality often compromises reliability ...

Feasibility and Dosimetric Impact of Intensity-Modulated Radiotherapy for Cervical Cancer Patients in Nepal: A Retrospective Analysis

Authors: Daniela Branco, John M Bryant, Surendra Bahadur Chand, Pratiksha Shahi, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, B.P. Koirala Memorial Cancer Hospital, , B.P Koirala Memorial Cancer Hospital, University of California San Diego / California Protons, Department of Radiation Oncology, Moffitt Cancer Center

Abstract Preview: Purpose:
Cervical cancer remains a significant health burden in Nepal, with 2169 new cases and 1313 deaths recorded in 2022. This study evaluates the feasibility of implementing step-and-shoot IMRT...

Impact of Patient Setup Errors on the MR Linac-Based SBRT Treatment for Prostate Cancer

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: In radiation therapy, patient setup errors have been a primary concern impacting dose delivery accuracy. A robust treatment plan is essential to mitigate these errors. This study aimed to eva...

Implementing a Knowledge-Based Planning Model for Gastrointestinal (GI) Site-Specific Plans for Photon Radiation Therapy

Authors: Andreea Dimofte, Maksym Sharma, Weibing Yang, Timothy C. Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose:
To assess the effectiveness and dosimetric impact of utilizing a knowledge-based planning model for GI site-specific plans.
Methods:
Six knowledge-based planning models were develope...

Influence of the α/ß Ratio on Dose Constraints in Radiotherapy of Prostate Cancer

Authors: Marwa Y. Abdel Tawwab, Amin E Amin, Abdullah M. ElSharif, Somaia Metwally Elsayed, Magdy M. Khalil

Affiliation: School of Applied Health Science, Badr University in Cairo (BUC), Cairo, Egypt, Medical Physics, Radiation Oncology Department, Faculty of Medicine, Ain Shams University, Medical Biophysics, Department of Physics, Faculty of Science, Helwan University

Abstract Preview: Purpose: Prostate cancer radiotherapy typically employs conventional fractionation schedules over approximately eight weeks. This study investigates the effect of variations in the α/β ratio on dose c...

Quantifying the Impact of Tissue Inhomogeneities on Calculated Dosimetry within LDR Brachytherapy

Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer

Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...

Utilizing Bladder Ultrasound to Estimate on-Table Bladder Volume in Prostate Cancer SBRT: Impact on Treatment Setup Consistency and Dosimetric Outcomes

Authors: Minsong Cao, Amar Kishan, Dylan P. O'Connell, Jonathan Pham, Michael Steinberg, Luca F Valle, Michael Xiang

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: To evaluate bladder ultrasound as a surrogate for estimating on-table bladder volume in prostate cancer patients undergoing stereotactic body radiation therapy (SBRT). The study aimed to asse...