Commissioning and Validation of Monaco Proton Treatment Planning System on a Compact Proton Therapy System

Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

Moving Towards Independent Assays of 90y Glass Microsphere Activity: Monte Carlo Simulation with Experimental Data

Authors: Mercy Iyabode Akerele, Yuni K. Dewaraja, Richard Laforest, Justin K. Mikell, Wendy Siman, Allan Thomas, Daniel Thorek

Affiliation: University of Michigan, Washington University School of Medicine in St. Louis, Washington University School of Medicine, University of Colorado Anschutz Medical Campus, School of Medicine, Washington University in St. Louis, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Post-therapy quantitative 90Y SPECT and PET measurements show ~25% lower activity than vendor-reported values for glass microspheres. We hypothesize this discrepancy is due to bremsstrahlung ...

Objective Verification of Mechanical and Radiation Isocenters Independent of Setup

Authors: Jonathan Dowell, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, Iridesce Solutions, Inc.

Abstract Preview: Purpose: The novel machine quality assurance (QA) device nΓΌFilm (Iridesce Solutions, Lexington KY) allows for an objective assessment of light and radiation fields independent of setup. Herein, the ab...

The Root Cause of Large Differences in Calculated Beam Monitor Units between a Treatment Planning System and a QA Software

Authors: George X. Ding, Kenneth L. Homann

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: It is standard practice that the beam monitor units (MUs) calculated by a commercial treatment planning system (TPS) is verified by a secondary dose calculation (SDC) software that independen...

Treatment Dose Reconstruction of Digitized Deliveries on Reflexion X1 System Based on Megavoltage Imager and Dose Monitor Chamber

Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...