Authors: Aaron Conard, Victoria Croog, Marie Gurka, Lan Lin
Affiliation: Johns Hopkins University
Abstract Preview: Purpose:
This study evaluates the utility of the Active Breathing Coordinator (ABC) and Surface Guided Radiation Therapy (SGRT) techniques in implementing Deep Inspiration Breath Hold (DIBH) for le...
Authors: Rami M. Shorti, Gary R. Stinnett
Affiliation: Intermountain Health, Radiation Oncology, Intermountain Health, Advanced Visualization Engineering Department
Abstract Preview: Purpose: In this work we present the workflow, materials analysis, and lessons learned from leveraging advanced 3D printing Polyjet Technology to print conformal bolus for radiation therapy.
Method...
Authors: Hailun Pan, Yingli Yang, Jie Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Department of Radiation Oncology, Ruijin Hospital, , Shanghai Jiaotong University School Of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute
Abstract Preview: Purpose: Accurate patient positioning is critical in radiotherapy (RT) to ensure effective treatment delivery and minimize harming surrounding healthy tissues. Vertebral misalignment during RT setup h...
Authors: Martha J. Malin, Matthew Schelin
Affiliation: NYU Langone Health
Abstract Preview: Purpose: To evaluate the agreement between ExacTrac Dynamic (ETD) and CBCT-based positioning for spine SRS/SBRT treatments during initial patient setup and repositioning after intrafraction motion.
Authors: Nrusingh C. Biswal, Matthew J Ferris, Michael J. MacFarlane, Jason K Molitoris, Byong Yong Yi, Mark J. Zakhary
Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland
Abstract Preview: Purpose: Proton head-and-neck treatment plans often struggle to maintain plan quality over the course of treatment due to tumor response, weight-loss, and setup variability. Plan robustness to these c...
Authors: Ruirui Dong, Gernot Echner, Peter Haering, Clarence King, Carlos Murillo, Gavin Poludniowski, Nicholas Sammut, Joao Seco, Steffen Seeber, Maria Francesca Spadea, Elpida Theodoridou
Affiliation: KIT, Department of Physics and Astronomy, Heidelberg University, Karolinska Institutet, DKFZ, University of Malta
Abstract Preview: Purpose:
The goal is to develop the first benchtop X-ray FLASH system based on a conventional small animal irradiator. The small animal irradiator will be modeled using a Monte Carlo toolkit for bo...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...
Authors: Min Su
Affiliation: Mount Sinai School of Medicine
Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...
Authors: Min Su
Affiliation: Mount Sinai School of Medicine
Abstract Preview: Purpose: To evaluate dosimetric impact of target coverage and organ at risk (OARs) sparing for whole breast patient setup roll/yaw change in 3D-conformal radiotherapy.
Methods: 8 whole breast cases...
Authors: Robbie Beckert, Weiren Liu, Thomas R. Mazur, Allen Mo, Stephanie Perkins, Hailei Zhang, Tianyu Zhao
Affiliation: Washington University in St. Louis School of Medicine, University of South Florida, WashU Medicine
Abstract Preview: Purpose: Online adaptation may mitigate uncertainties in proton therapy arising from interfractional anatomical changes. While robust optimization accounts for setup and range uncertainties during pla...
Authors: Nema Bassiri, Kristen A. Duke, Neil A. Kirby, Thomas Wilson Klender, Christien Kluwe, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz, Michelle de Oliveira
Affiliation: Miami Cancer Institute, University of Texas HSC San Antonio, UT Health San Antonio
Abstract Preview: Purpose: Determine the practical usability for three phantoms to be used with the ExacTrac Dynamic thermal imaging system. Thermal-guided imaging can be used for inter and intra motion management, pat...
Authors: Shifeng Chen, Mariana Guerrero, Michael J. MacFarlane, Huijun Xu, Baoshe Zhang, Jinghao Zhou
Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center
Abstract Preview: Purpose: The clinical value of surface-guided radiotherapy (SGRT) in prone breast cancer setups is much less established than in supine setups. This study explores SGRT's potential for prone breast pa...
Authors: CheukKai Becket Hui, Goldie M. Klein, Yildirim D. Mutaf, Amir Pourmoghaddas
Affiliation: UC Health, Kaiser Permanente
Abstract Preview: Purpose:
In this study, we investigated the effect of SGRT (Align-RT) implementation on patient setup accuracy for DIBH breast radiotherapy treatments.
Methods:
We extracted vertical post-ima...
Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey
Affiliation: Thompson Proton Center
Abstract Preview: Purpose: Proton therapy plans can be highly sensitive to both anatomical changes and positional errors, making the acquisition of Quality Assurance CT (QACT) images a routine clinical practice during ...
Authors: Emily Hansen, Alois M. Ndlovu, Niara Rowe, Roland Teboh
Affiliation: Hackensack University Medical Center
Abstract Preview: Purpose: The accuracy of SCINTIX biology-guided radiotherapy (BgRT) on the RefleXion X1 is dependent on the correct alignment of the isocenter between all subsystems, including setup lasers, kV imagin...
Authors: Alyssa Capizzi, John J Dombrowski, Nabil N. Khater
Affiliation: Saint Louis University
Abstract Preview: Purpose: To evaluate a mask-less adaptable headrest (MAHR) prototype for head-and-neck IMRT designed to reduce random and systematic shifts of patientsโ setups. MAHR complements current image-guidance...
Authors: Mercy Iyabode Akerele, Yuni K. Dewaraja, Richard Laforest, Justin K. Mikell, Wendy Siman, Allan Thomas, Daniel Thorek
Affiliation: University of Michigan, Washington University School of Medicine in St. Louis, Washington University School of Medicine, University of Colorado Anschutz Medical Campus, School of Medicine, Washington University in St. Louis, Mallinckrodt Institute of Radiology, Washington University School of Medicine
Abstract Preview: Purpose: Post-therapy quantitative 90Y SPECT and PET measurements show ~25% lower activity than vendor-reported values for glass microspheres. We hypothesize this discrepancy is due to bremsstrahlung ...
Authors: Siju C. George, Alonso N. Gutierrez, Vivek Mishra, Ranjini P. Tolakanahalli
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute
Abstract Preview: Purpose: This presentation focuses on optimizing dosimetry in RPT clinics by tackling initial setup challenges and ensuring the accuracy of SPECT/CT imaging for dosimetry. It will address the qualific...
Authors: Hua-Chieh Shao, Shanshan Tang, Jing Wang, Kai Wang, You Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, University of Maryland Medical Center
Abstract Preview: Purpose: Artifacts caused by gas bubble movement in the gastrointestinal tract can severely degrade the image quality of on-board abdominal cone-beam computed tomography (CBCT), impacting its utility ...
Authors: Lori Buchholtz, Alison Garda, Chris L. Hallemeier, Kathryn L. Kolsky, Han Liu, Joseph John Lucido, Marisa Schinter, Andrew J. Veres, Sara Walerak
Affiliation: Mayo Clinic
Abstract Preview: Purpose: The C_START initiative aims to streamline and simplify the Direct-to-Unit (DtU) clinical setup and treatment planning process for photon radiation therapy, particularly for emergent cases suc...
Authors: David Byun, Ting Chen, Paulina E. Galavis, Allison McCarthy, Hesheng Wang, Michael J Zelefsky
Affiliation: NYU Langone Health
Abstract Preview: Purpose: To summarize a MR guided adaptive workflow developed for pelvic lymph nodes (PLN) stereotactic radiotherapy using large field size on Elekta Unityยฉ MR Linac system, and to quantitatively anal...
Authors: Alejandro Bertolet, Jorge Naoki Dominguez Kondo, Bruce A. Faddegon, Thongchai Masilela, Isaac Meyer, Victor V. Onecha, Harald Paganetti, Jose A. Ramos-Mendez, Jan PO Schuemann, Wook-Geun Shin
Affiliation: University of California San Francisco, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital
Abstract Preview: Purpose: To present the results of 15 years of developments of the TOPAS TOol for PArticle Simulation framework, and to highlight recent and new developments.
Methods: Fundamental understanding...
Authors: Anthony J. Doemer, Bing Luo, Benjamin Movsas, Humza Nusrat, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia
Affiliation: Department of Physics, Toronto Metropolitan University, Henry Ford Health
Abstract Preview: Purpose: Large-vision models (LVMs) are rapidly emerging, yet their application in radiation oncology remains largely unexplored. This study investigates the potential of LVMs for offline adaptive rad...
Authors: Yi An, David J. Carlson, Zhe (Jay) Chen, Jun Deng, Dae Yup Han, Sameer Taneja
Affiliation: Yale School of Medicine, Yale University School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: Spine Stereotactic radiosurgery (SSR) delivers a large radiation dose and utilizes narrow PTV margins, on the order of 1 mm, to avoid excess dose to the spinal cord. Because of this, intrafra...