Authors: Suman Gautam, Tianjun Ma, William Song
Affiliation: Virginia Commonwealth University
Abstract Preview: Purpose: We propose an artificial intelligence (AI)-based method to rapidly predict the patient-specific quality assurance (PSQA) results for magnetic resonance (MR)-guided online adaptive radiation th...
Authors: Yu Chang, Mei Chen
Affiliation: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
Abstract Preview: Purpose: Spot weights optimization, as a critical step in the proton therapy, is often time-consuming and labor-intensive. Deep learning, with its powerful learning and computational efficiency, can e...
Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng
Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...
Authors: Alonso N. Gutierrez, Daniel E. Hyer, Blake R. Smith
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Iowa Health Care, University of Iowa
Abstract Preview: Purpose: To perform a feasibility study of optimizing and producing a compact range compensator to deliver single-energy pencil beam scanning (PBS) proton arc therapy treatments. Omitting energy chang...
Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal
Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...
Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo
Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...
Authors: Zhenzhen Dai, Anthony J. Doemer, Ryan Hall, Kenneth Levin, Bing Luo, Benjamin Movsas, Karen C. Snyder, Kundan S Thind, Eleanor Walker
Affiliation: Henry Ford Health, HFHS
Abstract Preview: Purpose: To investigate the feasibility of a predictive tool for efficient allocation of hypofractionated whole-breast irradiation patients between Varian Truebeam and Ethos systems.
Methods: A ful...
Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao
Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital
Abstract Preview: Purpose: This study quantitatively evaluates the interplay effect in intensity-modulated proton therapy (IMPT) for lung cancer stereotactic body radiotherapy (SBRT) using two different machine deliver...
Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Stephen Shang
Affiliation: South Florida Proton Therapy Institute, SFPRF
Abstract Preview: Purpose: Proton pencil beam scanning therapy is particularly sensitive to field translational shifts and beam range variations, which can degradation of dose distribution and compromise the treatment....
Authors: Wenhua Cao, Hadis Moazami Goudarzi, Madison Emily Grayson, Zongsheng Hu, Gino Lim, Steven Hsesheng Lin, Radhe Mohan
Affiliation: The University of Texas MD Anderson Cancer Center, Department of Industrial Engineering, University of Houston, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Proton Arc Therapy (PAT) offers significant potential in treating complex cancer cases by delivering a continuous radiation dose as the gantry rotates. This study aims to investigate the pote...
Authors: Hao-Wen Cheng, Jonathan G. Li, Chihray Liu, Wen-Chih Tseng, Guanghua Yan
Affiliation: University of Florida
Abstract Preview: Purpose: This study develops and evaluates deep learning (DL) models for predicting 3D dose distributions in simultaneous integrated boost (SIB) prostate cancer treatment using the Elekta Unity MR-Lin...
Authors: Ergun E. Ahunbay, Abdul Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao
Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Online adaptive replanning is often necessary in Intensity Modulated Proton Therapy (IMPT) due to the sensitivity of proton dose distributions to daily anatomical changes. A rapid, automated ...
Authors: Katja M. Langen, William Andrew LePain, Robert Muiruri, Vivi Nguyen, Mosa Pasha, Roelf L. Slopsema, Alexander Stanforth, Yinan Wang, Mingyao Zhu
Affiliation: Emory Healthcare, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) treatment planning for craniospinal irradiation (CSI) is complex and requires extensive effort from the planner. This study aims to enhance planning ...
Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos
Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen
Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...
Authors: Yabo Fu, Yang Lei, Yu Lei, Haibo Lin, Ruirui Liu, Tian Liu, Kenneth Rosenzweig, Charles B. Simone, Shouyi Wei, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York Proton Center
Abstract Preview: Purpose: Beam orientation optimization (BOO) in intensity-modulated radiation therapy (IMRT) is traditionally a complex, non-convex problem tackled with heuristic methods. This study benchmarks global...
Authors: Austen N. Curcuru, Arash Darafsheh, Winter Green, Yao Hao, Baozhou Sun, Tiezhi Zhang, Tianyu Zhao, Xiandong Zhao
Affiliation: WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Washington University in St. Louis, University of South Florida, Baylor College of Medicine
Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) requires precise setup imaging due to the sharp dose gradients and rapid distal fall-off seen in proton therapy dose distributions. Additionally, onl...
Authors: Kellin M De Jesus, Leon Dunn, Les Sztandera, David H. Thomas
Affiliation: IsoAnalytics Pty. Ltd., Thomas Jefferson University
Abstract Preview: Purpose: Machine accuracy and performance are critical for ensuring the safety and efficacy of intensity-modulated radiotherapy (IMRT and VMAT). This study aims to analyze a large and diverse set of l...
Authors: James Benton, Andrew Dewar, Benjamin C Lee, Ryan Y Lee
Affiliation: Radiotherapy Clinics of Georgia, Urology of Greater Atlanta
Abstract Preview: Purpose:
The purpose of our investigation was to determine if pre-treatment factors could predict urinary morbidity after combination radiation treatment for localized prostate cancer.
Methods:<...
Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...
Authors: Wesley A. Belcher, Aidan Burke, Matthew Green, Taylor Stamey
Affiliation: ECU Health, East Carolina University Brody School of Medicine
Abstract Preview: Purpose: The purpose of this study was to determine the effect of using deep inhalation breath hold (DIBH) vs. free breathing (FB) and intensity-modulated radiation therapy (IMRT) vs. 3D for right-sid...
Authors: Michael Confer, Mark A. Newpower
Affiliation: University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: A pediatric patient recently presented to our clinic for treatment for chordoma, which was near the brainstem. The clinician elected to treat this patient using intensity modulated proton the...
Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin
Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
Abstract Preview: Purpose: The purpose of this study was to investigate the interplay effect during intra-fractional motion and the effect of the robust optimization parameters for inter-fractional motion in the intens...
Authors: Angela Gathers, Christina Henson, Sakuntala Jagabattuni, Mark A. Newpower
Affiliation: University of Oklahoma HSC, Department of Otolaryngology, University of Oklahoma HSC, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: A previous departmental study showed an increase in ototoxicity (hearing loss) rates in head & neck cancer (HNC) patients treated with Intensity Modulated Proton Therapy (IMPT) vs. x-ray radi...
Authors: Hao Gao, Yuting Lin, Jufri Setianegara, Aoxiang Wang, Peng Xiao, Qingguo Xie, Yanan Zhu
Affiliation: Department of Biomedical Engineering, Huazhong University of Science and Technology, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Intensity-modulated proton therapy (IMPT) achieves uniform tumor dose distribution while sparing organs-at-risk (OAR) by optimizing spot weights across energy layers. Accelerating IMPT delive...
Authors: Kaile Li
Affiliation: Alexander T. Augusta Miliary Medical Center
Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...
Authors: Parker Anderson, Elizabeth L. Bossart, Jonathan Cyriac, Nesrin Dogan, Robert Kaderka, Yihang Xu
Affiliation: University of Miami, University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose:
Knowledge-based planning (KBP) can enhance the treatment planning process in cancer radiotherapy (RT). By training a KBP model with high-quality treatment plans developed by experts, dose-...
Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Michael H. Shang, Stephen Shang, Timothy R Williams
Affiliation: South Florida Proton Therapy Institute, SFPRF, Department of Radiation Medicine, MedStar Georgetown University Hospital
Abstract Preview: Purpose:
Daily image guidance for head and neck intensity-modulated proton therapy (IMPT) presents significant challenges due to large target volumes and anatomical changes. Geometric deviations al...
Authors: Somayeh Gholami, Saeedeh Ketabi, Jeremy Kunz, Ali Yousefi
Affiliation: Department of Radiation Oncology, University of Utah, University of Utah, Department of Management- Operations Research, University of Isfahan
Abstract Preview: Purpose: This paper aims to present a novel approach for automatic knowledge-based planning optimization for Intensity Modulated Radiotherapy, along with the two downsizing techniques for improving th...
Authors: Adebayo Abe, Samuel Olaolu Adeneye, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Sylvester Entonu, Muhammad Habeebu, Adedayo O. Joseph, Oluwaseyi Oderinde, Oluwadara Ojediran, Margaret Dideolu Taiwo
Affiliation: University of Ibadan, University of Lagos, Missouri University of Science and Technology, Purdue University, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre
Abstract Preview: Purpose:
Spatially Fractionated Radiation Therapy (SFRT) is an advanced radiotherapy technique designed to deliver highly heterogeneous radiation doses, aiming to optimize tumor control while minim...
Authors: Sumanta Manna, Atul Mishra, Surendra Prasad Mishra, Kailash Kumar Mittal, Anoop Kumar Srivastava, Neha Yadav
Affiliation: Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Department of radiation Oncology, Apollomedics Super Speciality Hospitals, Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Department of Radiation Oncology, Kalyan Singh Super Specialty Cancer Institute
Abstract Preview: Purpose: This study aimed to assess the dosimetric performance of Volumetric Modulated Arc Therapy (VMAT), step-and-shoot Intensity-Modulated Radiation Therapy (ss-IMRT), and dynamic Intensity-Modulat...
Authors: Yuzhen Ding, Hongying Feng, Jason Michael Holmes, Baoxin Li, Wei Liu, Daniel Ma, Lisa McGee, Samir H. Patel, Jean Claude M. Rwigema, Sujay A. Vora
Affiliation: Arizona State University, Department of Radiation Oncology, Mayo Clinic, Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose:
Intensity-modulated proton therapy (IMPT) is a preferred treatment modality for head and neck (H&N) cancer patients, offering precise tumor targeting while sparing surrounding organs at ri...
Authors: Nan Li, Yaoying Liu, Shouping Xu, Gaolong Zhang
Affiliation: Department of Radiation Oncology, School of Physics, Beihang University, School of physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: In intensity-modulated proton therapy (IMPT) for head and neck cancer, CBCT registration ensures accurate setup, minimizing dose errors. Unlike IMRT, IMPT plans directly define tumor volumes ...
Authors: Mark A. Newpower, Jill Taylor
Affiliation: University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: RayStation 2024A allows planners to optimize intensity modulated proton therapy (IMPT) plans using discrete arcs which can then be converted to traditional pencil beam scanning (PBS) beams fo...
Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu
Affiliation: Emory Healthcare, Emory University
Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...
Authors: Chia-Lung Chien, Wen C. Hsi, Romy Megahed, Kayla Schneider
Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
The dosimetric variations induced by inter-fractional anatomical changes in intensity-modulated proton therapy could impact the clinic outcomes for head-and-neck (HN) cancer patients. This...
Authors: Ergun E. Ahunbay, Abdul Kareem Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao
Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Secondary dose calculations (SDC) facilitate patient-specific quality assurance for online adaptive intensity-modulated proton therapy (IMPT). However, there is currently a lack of commercial...
Authors: Junghoon Lee, Todd R. McNutt, Harry Quon, Bohua Wan
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Department of Computer Science, Johns Hopkins University
Abstract Preview: Purpose: Xerostomia is a common toxicity in head and neck cancer (HNC) radiotherapy (RT). A few deep learning (DL) models have been proposed to predict the chance of xerostomia 12 months after RT with...
Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg
Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington
Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...
Authors: Daniela Branco, John M Bryant, Surendra Bahadur Chand, Pratiksha Shahi, Joseph Weygand
Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, B.P. Koirala Memorial Cancer Hospital, , B.P Koirala Memorial Cancer Hospital, University of California San Diego / California Protons, Department of Radiation Oncology, Moffitt Cancer Center
Abstract Preview: Purpose:
Cervical cancer remains a significant health burden in Nepal, with 2169 new cases and 1313 deaths recorded in 2022. This study evaluates the feasibility of implementing step-and-shoot IMRT...
Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...
Authors: Yang Sheng, Qingrong Jackie Wu, Qiuwen Wu, Xin Wu, Dongrong Yang
Affiliation: Duke University Medical Center
Abstract Preview: Purpose:
Treatment planning for intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) relies on inverse planning, an iterative and non-intuitive process of adjust...
Authors: Qianyi Xu, Inhwan Yeo
Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University
Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...
Authors: Shen Fu, Jun Hou, Zuofeng LI, Taize Yuan, Qingyuan Zhang, Yuanshui Zheng
Affiliation: GuangZhou Concord Cancer Center, Guangzhou Concord Cancer Center, 广州泰和肿瘤医院
Abstract Preview: Purpose: A visual feedback system is beneficial for patients to maintain consistent respiratory signal during gated radiotherapy, especially for intensity modulated proton therapy (IMPT) where motion ...
Authors: Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Minesh P. Mehta, Andrew J. Wroe, Jen Yu
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose: Linear energy transfer (LET) is directly related to relative-biological-effectiveness dose in proton therapy. This study aims to investigate how the treatment field hinge angles affect LET of...
Authors: Shen Fu, Zhangmin LI, Zuofeng LI, Yuanshui Zheng
Affiliation: GuangZhou Concord Cancer Center, Guangzhou Concord Cancer Center
Abstract Preview: Purpose: To investigate the influence of different robustness optimization strategies and parameters in proton therapy plans for head and neck tumors on target coverage and OAR (organ at risk) sparing...
Authors: Gregory A Azzam, Michael Butkus, Nesrin Dogan, Robert Kaderka, Nhan Vu, Yihang Xu
Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, University of Miami, Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: Knowledge-based planning (KBP) has demonstrated potential for improving planning quality and efficiency. Adoption of KBP in particle therapy has been slow due to limited number of plans to tr...
Authors: Yang Sheng, Qingrong Jackie Wu, Qiuwen Wu, Xin Wu, Dongrong Yang
Affiliation: Duke University Medical Center
Abstract Preview: Purpose:
This study aims to leverage large language model (LLMs) to develop a human-in-the-loop agentic framework, enhancing the efficiency of treatment planning in radiotherapy.
Methods:
A L...
Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider
Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...
Authors: Shahed Badiyan, Chien-Yi Liao, Mu-Han Lin, David D.M. Parsons, Justin D. Visak, Brien Timothy Washington, Kenneth Westover, Yuanyuan Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX
Abstract Preview: Purpose: Adaptive radiotherapy (ART) programs are resource-intensive due to their technical complexities, requiring highly skilled planners. Leveraging integrated automated treatment planning system (...
Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...
Authors: Indra J. Das, Ahtesham U. Khan, Andrew J. White, Poonam Yadav
Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine
Abstract Preview: Purpose: During intensity modulated radiotherapy (IMRT) planning, low MU segments (< 3 MU) are commonly avoided due to documented dosimetric nonlinearity and poor reproducibility. This work aims to ex...
Authors: Laurence Edward Court, Alexandra Olivia Leone, Zhongxing Liao, Saurabh Shashikumar Nair, Joshua S. Niedzielski, Ramon Maurilio Salazar, Ting Xu
Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Radiation Pneumonitis (RP) predictive models often rely on clinical and DVH parameters, but multiomic features from CT imaging and 3D dose distributions from various regions could provide add...
Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...
Authors: Md Mainul Abrar, Yujie Chi
Affiliation: University of Texas at Arlington, Department of Physics, University of Texas at Arlington
Abstract Preview: Purpose: Healthcare 5.0, proposed in 2021, includes interpretable healthcare analysis as a core component. Achieving this requires the application of explainable artificial intelligence (XAI) to overc...
Authors: Chia-Lung Chien, Wen C. Hsi, Faraz Kalantari, Pouya Sabouri, Man Yam
Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)
Abstract Preview: Purpose:
Reducing treatment delivery time is critical to improving patient throughput and minimizing the risk of intrafraction motion, which can compromise treatment accuracy. This study identifies...
Authors: Malvern Madondo, Mark McDonald, Zhen Tian, Christopher Valdes, Ralph Weichselbaum, Xiaofeng Yang, David Yu, Jun Zhou
Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Emory University, Department of Radiology, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Head-and-neck (HN) cancer patients often experience significant anatomical changes during treatment course. Proton therapy, particularly intensity-modulated proton therapy (IMPT), is sensitiv...
Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...
Authors: Richard Bakst, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Minglei Kang, Nancy Y Lee, Haibo Lin, Hang Qi, Charles B. Simone, Pingfang Tsai, Milo Vermeulen, Shouyi Wei, Xiaodong Wu, Lee Xu, Irini Yacoub, Xingyi Zhao, Ajay Zheng
Affiliation: University of Miami, Peking University, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, icahn school of medicine at mount sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose:
Three-dimensional lattice radiation therapy (3D-LRT) effectively achieves local tumor control with limited morbidity. Pencil beam scanning (PBS) proton therapy provides precise dose confor...
Authors: Dante PI Capaldi, Lu Jiang, Qihui Lyu, Ke Sheng
Affiliation: Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Preclinical small animal studies help understand radiation-induced biological responses, toxicities, and mechanisms, facilitating the translation of new therapies to patient treatment. Int...
Authors: Adebayo Abe, Samuel Olaolu Adeneye, Eben Aje, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Lilian Ekpo, Muhammad Habeebu, Adedayo O. Joseph, Charles S. Mayo, Noah Ndianaobong, Ikechi S Ozoemelam, Margaret Dideolu Taiwo, Godwin Uwagba
Affiliation: University of Michigan, University of Ibadan, University of Lagos, Missouri University of Science and Technology, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre, NSIA-LUTH Cancer Center
Abstract Preview: Purpose:
Head and neck cancers (HNC) present significant challenges in radiotherapy due to complex anatomy and the proximity to critical organs at risk (OARs). These challenges are compounded in na...
Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...
Authors: Xiu tong Lin
Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital
Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...
Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: Dose prediction (DP) is essential in guiding radiotherapy planning. However, current DP models for intensity-modulated radiation therapy (IMRT) primarily rely on fixed-beam orientations and a...
Authors: Chingyun Cheng, Ben Durkee, Carri K. Glide-Hurst, Minglei Kang, Haibo Lin, Bhudatt R. Paliwal, Charles B. Simone, Zhizhen Wei, Tengda Zhang, Xingyi Zhao
Affiliation: University of Wisconsin, Department of Mechanical Engineering, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: Transmission Beam (TB), Single-Energy Bragg Peak (SEBP), and Single-Energy Spread-Out Bragg Peak (SESOBP) are primary proton conformal FLASH techniques. However, each comes with significant l...
Authors: Kenny Guida, Daniel Johnson, Wesley Tucker
Affiliation: University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) has emerged as a standard of care for unilateral head and neck (HN) cancers due to superior OAR sparing. With the increase of proton centers national...