Search Submissions 🔎

Results for "inter scanner": 14 found

Black Bone MRI As a Surrogate for CT to Detect Intensity Differences in Mandible Sub-Volumes

Authors: Cem Dede, Clifton David Fuller, Renjie He, Laia Humbert Vidan, Stephen Y. Lai, Amy Moreno, Mohamed Naser, Kareem Abdul Wahid, Natalie A West

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Head and neck cancers (HNC) treated with radiation therapy can result in radiation-induced bone injury. In CT, changes in radiodensity correlate to changes in bone integrity. Most studies use...

CT-on-Rails Longitudinal Image Quality Stability for Intensity Modulated Adaptive Proton Therapy

Authors: Austen N. Curcuru, Arash Darafsheh, Winter Green, Yao Hao, Baozhou Sun, Tiezhi Zhang, Tianyu Zhao, Xiandong Zhao

Affiliation: WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Washington University in St. Louis, University of South Florida, Baylor College of Medicine

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) requires precise setup imaging due to the sharp dose gradients and rapid distal fall-off seen in proton therapy dose distributions. Additionally, onl...

Characterizing the Stability of Upright CT for Proton Therapy

Authors: Brian Burger, Carri K. Glide-Hurst, John W. Hayes, Carson Hoffman, Minglei Kang, Jessica R. Miller, Jordan M. Slagowski, Yuhao Yan

Affiliation: Department of Human Oncology, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Leo Cancer Care

Abstract Preview: Purpose: The combination of upright CT and patient positioner for particle therapy present tremendous potential for high precision IGRT and online adaptive radiation therapy (ART), where reliable CT p...

Cross-Calibration of CT Number to Electron and Physical Density: Feasibility of Using Diagnostic Scans for Treatment Planning

Authors: Afrouz Ataei, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Even though many patients undergo diagnostic CT scans prior to treatment, simulation CT scans are commonly required for treatment planning. This study evaluates whether prior diagnostic CT sc...

Impact of Computed Tomography Noise Reference Levels in a Pediatric Hospital

Authors: Samuel L. Brady, Joseph G. Meier

Affiliation: Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To establish noise reference levels for our pediatric hospital.
Methods:
Water equivalent diameter (Dw) and image noise was automatically measured by using a global noise algorithm i...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Leveraging Photon Counting Detector CT and Advance Reconstructions to Improve the Accuracy of Vessel Tracing in Prostate Artery Embolization

Authors: Christopher P. Favazza, Andrea Ferrero, Taylor Froelich, Forrest Linch, Scott Thompson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Photon counting detector (PCD) CT is a promising tool to enhance pre-procedural planning and intra-procedural guidance for prostate artery embolization due to its unsurpassed ultra-high spati...

Lu-177 Recovery Coefficients Using Tc-99m Surrogate Method: Intra- & Inter-Scanner Comparison

Authors: Ben Piacitelli, Celeste Winters

Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...

Optimization-Based Image Reconstruction Regularized with Inter-Spectral Structural Similarity for Limited-Angle Dual-Energy Cone-Beam CT

Authors: Chih-Wei Chang, Junbo Peng, Richard L.J. Qiu, Justin Roper, Xiangyang Tang, Tonghe Wang, Huiqiao Xie, Xiaofeng Yang, David Yu

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Emory Univ, Emory University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered a promising solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, ...

Preliminary Evaluation of Ultrasound-Derived Fat Fraction Reliability in a Pediatric Cohort

Authors: Lizbeth Ayala-Dominguez, Aaron L Carrel, Diego Hernando, Gabrielle L Hoffmann, Amber Possell, Ivan M. Rosado-Mendez, Jiayi Tang, Andrew Wentland

Affiliation: Department of Pediatrics, University of Wisconsin-Madison, Department of Radiology, University of Wisconsin-Madison, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: Metabolic dysfunction-associated steatotic liver disease (MAFLD) is the leading cause of chronic liver disease in children. While biopsy remains the diagnostic standard, non-invasive imaging ...

Radiological Assessment of Radiochromic Film Models EBT3 and EBT4 in Proton Beams

Authors: Kuan Ling Chen, Jiajin Fan, Rao Khan, Robabeh Rahimi

Affiliation: University of Maryland, Inova Schar Cancer Institute, Howard University

Abstract Preview: Purpose: This study evaluates the dose response, energy dependency, sensitivity, reproducibility, temporal response, and LET dependency along and in the plane perpendicular to a clinical proton beam f...

Redesigning the CT Protocol Intranet: Solutions for Improved Access and User Engagement

Authors: Emi Ai Eastman, Vu Nguyen, Alexander W. Scott, Lucien Zang, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose:
Three key features were developed to substantially improve a previously in-house developed CT protocol website: a structured backend for efficient protocol creation and edit; the ability t...

Sources of Variability in Evaluating Ultrasound Imaging Performance Using Randomly-Distributed Hypoechoic Sphere Phantom

Authors: Cristel Baiu, Zheng Feng Lu, Dufan Wu, Baihui Yu

Affiliation: University of Wisconsin, Massachusetts General Hospital, University of Chicago

Abstract Preview: Purpose: IEC TS 62791:2022 specified a clinically meaningful and quantitative framework for evaluating diagnostic ultrasound performance by measuring the lesion signal-to-noise ratio (LSNR) using rand...

The Effect of 2D Antiscatter Grid-Based CBCT on Tissue Visualization in the Prostate Region: An Observer Study on Tissue Delineation Accuracy

Authors: Cem Altunbas, Adam Avant, Farhang Bayat, Roy Bliley, Ian Boor, Brian Kavanagh, Uttam Pyakurel, Tyler Robin, Ryan Sabounchi

Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic

Abstract Preview: Purpose: Improved soft tissue visualization plays an important role in target localization and treatment plan adaptation in CBCT-guided radiotherapy. In this work, a novel CBCT approach, 2D antiscatte...