Authors: Jonathan Dowell, Grace Francis, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Iridesce Solutions, Inc.
Abstract Preview: Purpose: A novel radiation therapy quality assurance (RT QA) device has been designed, constructed and tested. The nüFilmTM machine QA system provides a method for collecting light, mechanical and rad...
Authors: Josephine Chen, CheukKai Becket Hui, Yildirim D. Mutaf
Affiliation: Kaiser Permanente
Abstract Preview: Purpose:
To demonstrate the effectiveness of a target clustering program in generating cluster configurations and isocenter placements for multiple brain lesions in SRS treatment planning, with the...
Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health
Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...
Authors: Ivan L. Cordrey, Dharmin D. Desai, Ellis Lee Johnson
Affiliation: Cumberland Medical Center - Cancer Center, University of Kentucky, Varian Advanced Oncology Solutions
Abstract Preview: Purpose: HyperArc (HA) is known to produce a high quality SRS plan. Adding Surface Area Informed Optimization (SAIO) to HA has been shown to improve plan quality metrics R50% and the Conformality Inde...
Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou
Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation
Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...
Authors: Jacob Gooslin, Ellis Lee Johnson, Damodar Pokhrel
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: HyperArc radiosurgery permits treatment of multiple brain lesions using a single-isocenter improving treatment planning efficiency and workflow. A key stereotactic planning aspect is an indep...
Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng
Affiliation: UC San Diego, UCSD, University of California San Diego
Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...
Authors: Maria de la Luz De Ornelas, Yunze Yang
Affiliation: University of Miami
Abstract Preview: Purpose:
An extended Winston-Lutz test (EWL), also known as off-axis Winston-Lutz, was performed to assess the linear accelerator’s (linac) deviations at isocenter and five off-iso targets. The imp...
Authors: William E Burrell, Philip F. Durham, Anne N Hubbard, Yohan Akeakamai Walter, Hsinshun Terry Wu
Affiliation: Willis Knighton Cancer Center
Abstract Preview: Purpose: Linear accelerator (LINAC)-based single-isocenter, multi-target (SIMT) treatment has streamlined the stereotactic radiosurgery (SRS) workflow. However, off-isocenter treatment carries multipl...
Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang
Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...
Authors: Molokotima Kekana, Dennis S. Mackin, Stephen W. Peterson, Jerimy C. Polf
Affiliation: Department of Physics, University of Cape Town, M3D, Inc, The University of Texas MD Anderson Cancer Center, Houston
Abstract Preview: Purpose: To study the imaging characteristics of a prototype prompt gamma (PG) imaging system consisting of multiple rotating Compton cameras (CC).
Methods: The prototype CC imaging system is c...
Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold
Affiliation: Scripps Cancer Center
Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...
Authors: J. Daniel Bourland, Christina K Cramer, Justin M. Napolitano, James D. Ververs
Affiliation: Wake Forest University School of Medicine
Abstract Preview: Purpose:
Brain metastases (BM) can be treated with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS). Treatment planning for this modality has evolved over time; treatment plans typi...
Authors: Anthony J. Doemer, Yimei Huang, Benjamin Movsas, Ellen Park, Mira Shah, Salim Siddiqui, Karen C. Snyder, Kundan S Thind, Bo Zhao
Affiliation: Henry Ford Health
Abstract Preview: Purpose: The 6 degrees-of-freedom (6-DoF) robotic couch is considered essential for linac-based stereotactic radiosurgery (SRS), particularly for irregularly shaped targets adjacent to critical organs...
Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...
Authors: Colton Baley, Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz
Affiliation: UT Health San Antonio, Texas Oncology, University of Texas HSC San Antonio
Abstract Preview: Purpose: To evaluate the accuracy of off-axis winston lutz (WLT) for linac based stereotactic radiosurgery (SRS) treatments using in-house phantom.
Methods: Traditional WLT that uses cone and s...
Authors: Mark W. Geurts, Bridget Ann Melke
Affiliation: Aspirus Health
Abstract Preview: Purpose:
To develop a tool that streamlines and standardizes the process of positioning the SRS MapCHECK detector for intersecting multiple metastases during SRS QA of Single-Isocenter, Multiple Ta...
Authors: Issra Rashed, Jennie Wilder, Jingeng Zhu
Affiliation: Rush Riverside Cancer Institute, Advanced Oncology Solutions (AOS) Varian, a Siemens Healthineers company
Abstract Preview: Purpose: Develop a method to plan and deliver homogeneous dose to Craniospinal(CS) irradiation on Linear Accelerator.
Methods: Three treatment planning volumes (PTV) are created in sequence from su...
Authors: John Ginn, Zhuoyun Huang, Yongbok Kim, Ke Lu, Chunhao Wang, Yibo Xie, Zhenyu Yang, Jingtong Zhao
Affiliation: Duke University, Duke Kunshan University
Abstract Preview: Purpose: This study aims to develop and validate a machine learning model for predicting V60%, a critical dosimetric metric in LINAC-based Single-Isocenter-Multiple-Targets (SIMT) stereotactic radiosu...
Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone, Lesley A Jarvis, Allison Matous
Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose: During external beam radiation therapy, couch kicks are often necessary to achieve effective treatments, yet they make interpreting Cherenkov images much more challenging. We present a surfac...
Authors: Jennifer Kwak, Chelsea Manica, Justin K. Mikell, Michael Silosky, Wendy Siman
Affiliation: Washington University School of Medicine in St. Louis, University of Colorado Anschutz Medical Campus, School of Medicine, Rocky Vista University
Abstract Preview: Purpose:
This study evaluates synthetic planar imaging (synP) from SPECT projections against conventional planar imaging, focusing on detectability, spatial resolution, and feasibility. SynP allows...
Authors: Avery Antes, Bulent Aydogan, Rama Chicfeh, Erik Pearson, Neslihan Sarigul
Affiliation: The University Of Chicago, The University of Chicago
Abstract Preview: Purpose: This study evaluates the performance of the Ethos Treatment Planning System (TPS) in managing oligometastatic cancer patients previously treated using multiple isocenter plans.
Methods: Th...
Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...
Authors: Hongyu Jiang
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: This study presents a method for transforming coordinates from RayStation’s treatment planning system into the Monte Carlo (MC) coordinate system used in GEANT4 for dose calculations in spot ...
Authors: Shifeng Chen, Yannick P. Poirier, Huijun Xu, Byong Yong Yi, Baoshe Zhang, Hong Zhang, Jinghao Zhou
Affiliation: University of Maryland School of Medicine, University of Maryland Shore Regional Cancer Center, Vanderbilt University Medical Center, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center
Abstract Preview: Purpose: To thoroughly assess the resilience of HyperArc VMAT plans for multiple brain metastases (MBT) in relation to (i) high-definition MLC leaf positional inaccuracies and (ii) patient rotational ...