Search Submissions ๐Ÿ”Ž

Results for "isocenter size": 33 found

3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

4D Monte Carlo Dose Evaluation for Mobile Targets in a Magnetic Field

Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun

Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

Assessment of Off-Target Dose for Curative Treatment of Pregnant Head and Neck Cancer Case: A Monte-Carlo Study

Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park

Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital

Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...

Calibration of Dynamic Collimation System Trimmers to Proton Beam Axis Using Gantry-Angle-Specific Corrections: A Look-up Table Solution

Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Iowa, Iowa Health Care

Abstract Preview: Purpose: In proton therapy, the substantial size of the gantry introduces sag, causing the proton isocenter to drift as a function of gantry angle. While the scanning magnets correct the beamโ€™s isocen...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Comparison of Patient Localization on Visionrt Alignrt and Varian Identify

Authors: Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Surface imaging has been used clinically more regularly. The accuracy of several commercial products has been studied. AAPM TG302 also has proposed the system quality assurance and commission...

Comparison of the Sun Nuclear Multi-Met Winston Lutz Test and Varian's Machine Performance Check for Isocenter Alignment for Rotational Accuracy

Authors: Junsheng Cao, Luis A. Maduro Bustos, Khushdeep Singh

Affiliation: Overlook Medical Center, Atlantic Health System at Morristown Medical Center

Abstract Preview: Purpose: To evaluate the agreement between the Sun Nuclear Multi-Met Winston Lutz test (WL) and Varianโ€™s Machine Performance Check (MPC) in assessing isocenter alignment, couch, and collimator rotatio...

Design and Testing of a 3D-Winston-Lutz Phantom to Quantify Isocentricity of Pencil Beam Scanning Proton Therapy Machines

Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani

Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...

Design of Filtimator (Filter + Collimator) for CBCT of Pediatric Cancer Patients Receiving Proton Therapy

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...

Determine the Isocenter and Its Size for MR Linac Unity Part1: (U V) of Cax

Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...

Determine the Isocenter and Its Size for MR Linac Unity Part2: (u v) of BB and Isocenter Position and Size

Authors: Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
This study, the second in a two-part series, evaluates the isocenter position (the point in 3D space minimizing the sum of Euclidean distances to the MLC's central axis) and isocenter size...

Evaluation of Time Delays in a Surface-Guided Radiotherapy-Based Gating System Using Exactrac Dynamic and Truebeam Linear Accelerator

Authors: Hiroki Katayama, Hiroki Kawasaki, Motonori Kitaoka, Yosuke Takahashi, Takashi Tanii, Masato Tsuzuki

Affiliation: Kagawa University Hospital

Abstract Preview: Purpose:
Surface-guided radiotherapy (SGRT) with ExacTrac Dynamic (ETD) allows motion tracking and beam gating during treatment delivery. Accurate evaluation of beam-on and beam-off delays is essen...

Evaluation of the Imaging Performance of PET-Linac As Compared to a Diagnostic PET/CT System for Small Tumors

Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu

Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To systematically evaluate the relationship between Activity Concentration (AC) obtained from the RefleXion PET-Linac with the maximum standardized uptake value (SUVmax) derived from a diagno...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

Evaluation of the Varian Truebeam Linac Matching Process: Before, during, and after the Commission

Authors: Edwin Quashie, Yun Wang

Affiliation: Indiana University Medical School, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: To provide a formal evaluation for the TrueBeam linac matching process before, during and after the commission of the newly installed TrueBeam linac which we want to match to an existing True...

Feasibility of Producing GRID Therapy Dosimetry Using a Compact Linac Treatment Head with Pencil Beam Scanning

Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin

Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...

Impact of Six Degrees of Freedom Intrafraction Motion on Target Coverage for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Anupama Chundury, Hyejoo Kang, John C. Roeske, Iris A. Rusu

Affiliation: Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose: To quantify the dosimetric impact of six degrees of freedom (6DoF) intrafractional errors on gross tumor volume (GTV) and planning target volumes (PTV) for single-isocenter multi-target stere...

Investigation of the Impact of Dlg Changes on Plan Quality and Patient Specific QA

Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold

Affiliation: Scripps Cancer Center

Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...

Isocenter Optimization for Linear Accelerator-Based Radiosurgical Treatment Planning for Multiple Brain Metastases

Authors: J. Daniel Bourland, Christina K Cramer, Justin M. Napolitano, James D. Ververs

Affiliation: Wake Forest University School of Medicine

Abstract Preview: Purpose:
Brain metastases (BM) can be treated with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS). Treatment planning for this modality has evolved over time; treatment plans typi...

Optimizing Phantom Measurement of Simt Radiosurgery

Authors: Mark W. Geurts, Bridget Ann Melke

Affiliation: Aspirus Health

Abstract Preview: Purpose:
To develop a tool that streamlines and standardizes the process of positioning the SRS MapCHECK detector for intersecting multiple metastases during SRS QA of Single-Isocenter, Multiple Ta...

Planning and Delivering Homogenous Dose to Craniospinal Irradiation on Linear Accelerator

Authors: Issra Rashed, Jennie Wilder, Jingeng Zhu

Affiliation: Rush Riverside Cancer Institute, Advanced Oncology Solutions (AOS) Varian, a Siemens Healthineers company

Abstract Preview: Purpose: Develop a method to plan and deliver homogeneous dose to Craniospinal(CS) irradiation on Linear Accelerator.
Methods: Three treatment planning volumes (PTV) are created in sequence from su...

Prostate SBRT Motion Study and PTV Margin Evaluation with Exactrac Fiducial Tracking

Authors: Ahmad K. Al-Basheer, Andrew Clarke Grice, Kelly E. Hosier, Mark Logsdon, Evan A. Silverstein, Chris Tunnicliff, Chuan Wu

Affiliation: Sutter Medical Foundation, Sutter Health

Abstract Preview: Purpose: For Prostate SBRT Boost treatments, determine whether a uniform 2mm CTV to PTV margin is sufficient to give 95% dose coverage to the CTV in 90% of patients via a modified Van Herk Margin Form...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

Streamlining Hippocampal-Sparing Whole-Brain VMAT Planning: Enhancing Efficiency and Plan Quality with an Automated Workflow

Authors: Eric C. Ford, Yulun He, Minsun Kim, Dustin Melancon, Juergen Meyer, Dong Joo Rhee, Yinghua Tao

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, MD Anderson Cancer Center, University of Washington

Abstract Preview: Purpose: To develop and evaluate an automated-planning technique capable of generating high-quality treatment plans for hippocampal-sparing-whole-brain radiation therapy.
Methods: An auto-planning ...

Technique Factors Optimization and Radiation Dosimetry of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...

Through in-House Software and Customized Phantom to Perform and Analyze Daily Quality Assurance of Proton Treatment System More Efficiently and Monitor the Stability of Its Performance

Authors: Liang-Hsin Chen, Li-Chien Wei

Affiliation: National Taiwan University Cancer Center

Abstract Preview: Purpose: For proton therapy treatment, it is essential to ensure that the treatments are delivered safely and accurately. Quality assurance (QA) programs of proton treatment system is needed and proto...

To Assess and Monitor the Characteristics of Scanning Proton Beam Utilizing the Xrv-124 Scintillator Device

Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag

Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University

Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...

Two-Element Complementary Sensor for out-of-Plane Tracking in MR-Guided Radiotherapy

Authors: Zhaohui Han, Piotr Zygmanski

Affiliation: Brigham and Womenโ€™s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Radiation Oncology, Brigham and Womenโ€™s Hospital, Dana-Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: Real-time motion tracking/gating are oftentimes limited to a single sagittal plane on many magnetic resonance linear accelerators (MR-Linac). Out-of-plane motion is therefore difficult to det...

Uncertainty Analysis of Hyperarc VMAT Plans for Stereotactic Radiosurgery Patients with Multiple Brain Metastases

Authors: Shifeng Chen, Yannick P. Poirier, Huijun Xu, Byong Yong Yi, Baoshe Zhang, Hong Zhang, Jinghao Zhou

Affiliation: University of Maryland School of Medicine, University of Maryland Shore Regional Cancer Center, Vanderbilt University Medical Center, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center

Abstract Preview: Purpose: To thoroughly assess the resilience of HyperArc VMAT plans for multiple brain metastases (MBT) in relation to (i) high-definition MLC leaf positional inaccuracies and (ii) patient rotational ...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...

Variations in Radiation Isocenter Offsets from the Winston-Lutz Test Performed on Different Photon Energies

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: To quantity variations in Winston Lutz (WL) test results due to different energies used in SBRT, SRT or SRS.
Methods: A WL phantom with a 6.4 mm diameter center radio-opaque sphere is used...