Search Submissions πŸ”Ž

Results for "knife stereotactic": 12 found

A Dosimetric Analysis between Surgically Targeted (STaRT) Radiation Therapy and External Beam Stereotactic Radiation Therapy for Glioblastoma Resection Cavities

Authors: Jamieson Baker, Emel Calugaru, Yijian Cao, Jenghwa Chang, Jessica Jung, Jian Liu, Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke

Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health, Hofstra University Medical Physics Program

Abstract Preview: Purpose: Our hospital network has options to treat recurrent glioblastoma (GBM) with surgically targeted Cesium-131 brachytherapy, external beam stereotactic radiotherapy (SRT) with Varian TrueBeam, H...

A Motion Tracking Quality Assurance Platform for the Leksell Gamma Knife Hdmm System

Authors: Tsuicheng D. Chiu, Strahinja Stojadinovic, Aaron Thomlinson, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: Design and develop an automated verification and validation platform for the Elekta Leksell Gamma Knife (GK) Icon/Esprit High-Definition Motion Management (HDMM) system.

Methods: The H...

Adapting Newer Treatment Planning Strategy for Uveal Melanoma Cases Using Gamma Knife Radiosurgery

Authors: Deepak Agrawal, Subhash Gupta, Shashanksharad Kale, Gopishankar Natanasabapathi, Manoj Phalak, Dhanabalan Rajasekaran, Surendra Kumar Saini, Subramani Vellaiyan

Affiliation: All India Institute of Medical Sciences (AIIMS), All India Institute of Medical Sciences

Abstract Preview: Purpose:
To evaluate planning strategy for uveal melanoma tumor (UM) in gamma knife stereotactic radiosurgery (GKSRS) using Lightning inverse planning software for treatment planning.
Methods:

Auto-Contouring of OAR Enhances Patient Safety and Workflow in Gamma Knife Stereotactic Radiosurgery

Authors: Sven Ferguson, S. Murty Goddu, Ana Heermann, Taeho Kim, Nels C. Knutson, Hugh HC Lee, Shanti Marasini, Timothy Mitchell, Seungjong Oh, Kevin Renick

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis

Abstract Preview: Purpose: In the Gamma Knife stereotactic radiosurgery (GK-SRS), the delineation of organs-at-risks (OARs) was not fully automated. Due to the cumbersome nature of manual OAR contouring, dose evaluatio...

Clinical Outcomes of Gamma Knife Stereotactic Radiosurgery Treatments for Intracranial Arteriovenous Malformations & Fistulas: A Single Institutional Retrospective Study

Authors: Madeleine Arbogast, David Dorndos, Denise E Foltz, Justin Fraser, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Neurosurgery, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: For stereotactic radiosurgery (SRS) treatments of intracranial arteriovenous malformations (AVM) and fistulas (AVF), same-day Leksell Gamma Knife (GK) is the preferred modality. Long-term cli...

Comparison of Frame-Based and Frameless Gamma Knife Coordinate Spaces for Treatment of Trigeminal Neuralgia

Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Development of a Deep Learning Model for Accurate Brain Dose Prediction in Multi-Target Stereotactic Radiosurgery Plan Evaluation

Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Wenyin Shi, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Multi-target stereotactic radiosurgery (SRS) planning poses challenges due to complex geometries, small target volumes, and steep dose gradients. Achieving a balance between target coverage a...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Novel AI-Powered Tool to Objectively Evaluate Brain Dose for Multi-Met Stereotactic Radiosurgery Optimization

Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Richard A. Popple, Wenyin Shi, Rodney J. Sullivan, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao

Affiliation: Thomas Jefferson University, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: Objectively evaluating brain sparing as a plan-quality indicator for patients receiving stereotactic radiosurgery (SRS) to multiple metastases (multi-met) is complicated by variability in tar...

Workflow for Same Day Linac-Based Stereotactic Radiosurgery

Authors: William Amestoy, Carolina Benjamin, Markus Bredel, Rodrigo Delgadillo, Nesrin Dogan, Michael E Ivan, Ricardo J Komotar, Gregory J. Kubicek, Eric Mellon, Ivaylo B. Mihaylov, Maria Irene Monterroso, Raymond A. Schulz, Ashish Shah, Robert M Starke

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, Varian Medical Systems

Abstract Preview: Purpose: Stereotactic Radiosurgery (SRS) is a widely used treatment modality in radiation oncology, utilizing various technologies such as Gamma Knife (GK), Cyber Knife (CK) and Linac-based SRS with H...