Search Submissions 🔎

Results for "layer detector": 23 found

A Deep Learning Method for Direct Vmi Inference Using a Dual-Layer Radiotherapy Kv-CBCT Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: A challenge for dual energy CBCT is that noise and residual errors in material decomposition steps can become amplified when forming low energy, high contrast virtual mono-energetic images (V...

A Monte Carlo Framework for Automated Quality Assurance of Dynamically Collimated Pencil Beam Scanning Clinical Treatment Deliveries

Authors: Laura Bennett, Wesley S. Culberson, Albert Du, Kevin J. Erhart, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care, .decimal

Abstract Preview: Purpose: To develop and experimentally validate a novel Monte Carlo (MC) framework designed to enable calculation-based quality assurance (QA) for collimated intensity modulated proton therapy treatme...

A Novel Linac Onboard Dual-Layer Kv Imager Provides Increased Clinical CBCT Contrast and Metal Artifact Reduction Using Virtual Monoenergetic Images

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Dual-energy imaging offers benefits, including metal artifact reductions (MAR) and improved contrast, that enhance visualization. Currently, dual-energy imaging is largely limited to CT scann...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

Asymmetrical High Performance Brain Dedicated PET System: Design Optimization and Performance Evaluation

Authors: Yuemeng Feng, Hamid Sabet

Affiliation: Massachusetts General Hospital, Harvard Medical School

Abstract Preview: Purpose: We propose a novel brain-dedicated PET system comprising elliptical cylinder with a neck cut-out, supplemented by front and back panels to improve sensitivity and line-of-response sampling. T...

Backscattering of Compton Cameras: A Monte Carlo Simulation Approach

Authors: Jorge Naoki Dominguez Kondo, Qihui Lyu

Affiliation: University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Targeted alpha therapy (TAT) has emerged as a highly potent therapeutic method in oncology, but its development is limited by the lack of imaging methods to quantify its dosimetry. Convent...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Characterizing Image Quality and Radiation Dose in Fluoroscopy Systems

Authors: Kainoa Calistro-Allen, Brendon J. Villegas

Affiliation: University of Alabama Birmingham

Abstract Preview: Purpose:
To compare differences in radiation output and image quality in clinical esophagrams across fluoroscope vendors in use at University of Alabama Birmingham, prompted by reports that a newly...

Design of Next Generation Hemispherical Brain PET System Aiming for 1mm Resolution

Authors: Go Akamatsu, Yuma Iwao, Kurumi Narita, Hideaki Tashima, Taiga Yamaya, Eiji Yoshida

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose: In brain positron emission tomography (PET), higher spatial resolution is better for visualizing detailed structures such as small nuclei and the layered structure of the cerebral cortex. The...

Detector Physics-Incorporated Diffusion Denoising Models for Digital Breast Tomosynthesis with Dual-Layer Flat Panel Detectors

Authors: Alexander Bookbinder, Matthew Tivnan, Xiangyi Wu, Wei Zhao

Affiliation: Stony Brook Medicine, Massachusetts General Hospital

Abstract Preview: Purpose: To investigate and benchmark a system-adaptive diffusion-based digital breast tomosynthesis (DBT) denoising model for a direct-indirect dual-layer flat panel detector (DI-DLFPD) with a k-edge...

Development of Preclinical Multiscale Dosimetry for Beta-Particle Emitting Radionuclide in Radiopharmaceutical Therapy

Authors: Adedamola Adeniyi, Bryan Bednarz, Malick Bio Idrissou, Reinier Hernandez, Ohyun Kwon, Brian W. Miller, Zachary S Morris, Maya Takashima, Jamey Weichert

Affiliation: Departments of Radiation Oncology and Medical Imaging, University of Arizona, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin–Madison, Department of Radiology, School of Medicine and Public Health, University of Wisconsin–Madison, Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin–Madison

Abstract Preview: Purpose: As radiopharmaceutical therapy (RPT) becomes more prevalent in clinical applications, understanding dose-response relationships in the tumor microenvironment (TME) and normal tissues is essen...

Dose Rate Measurements of Scanning Carbon Ion Beams Using a Plastic Scintillator Detector

Authors: Motohiro Kawashima, Adrian Kugara, Masao Nakao, Shuichi Ozawa, Mutsumi Tashiro, Maria Varnava

Affiliation: Gunma University Heavy Ion Medical Center, Hiroshima High-Precision Radiotherapy Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the time-dependent dose rate characteristics of a scanning carbon ion beam using a fast-response plastic scintillator detector (PSD), with a focus on its potentia...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

Imaging Performance of Direct-Indirect Dual-Layer Flat-Panel-Detector Prototypes for Contrast-Enhanced Digital Mammography

Authors: Salman M. Arnab, Yves Chevalier, Samuel Gagné, Adrian F. Howansky, Luc Laperrière, Xiangyi Wu, Wei Zhao

Affiliation: Stony Brook Medicine, Analogic Canada

Abstract Preview: Purpose: A direct-indirect dual-layer flat-panel-detector (DI-DLFPD) is under development for patient motion artifact-free contrast-enhanced digital mammography (CEDM). DI-DLFPD comprises a direct fro...

Impact of Translucent Sheet Bolus and Melanin Concentration on Recorded Optical Signal during Cherenkov Imaging in External Beam Radiation Therapy

Authors: Jacqueline M. Andreozzi, Savannah Decker, Diego Hernandez, Iman R. Washington

Affiliation: UC San Diego, Department of Radiation Oncology, Moffitt Cancer Center, University of South Florida, Moffitt Cancer Center

Abstract Preview: Purpose: Recent advances in external beam radiation therapy have begun to explore the utility of Cherenkov radiation imaging as a beam delivery visualization tool. When sheet bolus is used during trea...

Incorporating Cyclic Group Equivariance into Deep Learning for Reliable Reconstruction of Rotationally Symmetric Tomography Systems

Authors: Fang-Fang Yin, Lei Zhang, Yaogong Zhang

Affiliation: Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Rotational symmetry is an inherent property of many tomography systems (e.g., CT, PET, SPECT), arising from the circular arrangement or rotation of detectors. This study revisits the image re...

Isocenter Stability after Commissioning of Biology-Guided Radiotherapy (BgRT)

Authors: Emily Hansen, Alois M. Ndlovu, Niara Rowe, Roland Teboh

Affiliation: Hackensack University Medical Center

Abstract Preview: Purpose: The accuracy of SCINTIX biology-guided radiotherapy (BgRT) on the RefleXion X1 is dependent on the correct alignment of the isocenter between all subsystems, including setup lasers, kV imagin...

Long-Term Stability Assessment of an Imaging Ring System Using One Year of Monthly Quality Assurance Data

Authors: Awens Alphonse, Nebi Demez, Brian P. Laffey, Shyam Pokharel, Suresh Rana, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: The Imaging Ring is a mobile digital X-ray system capable of producing 2D planar X-rays, fluoroscopy, and 3D Cone-Beam Computed Tomography (CBCT) images. This study aimed to evaluate the long...

Modified Dehazenet for Scatter Correction in Triggered Imaging: Enhancing Visibility and Alignment Precision for Radiation Therapy

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...

Plastic Scintillating Detector Assisted Spot Mapping for Patient Specific Quality Assurance in Proton Beam Therapy

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Validation of a Novel Dielectric Layer-Based Detector for Linear Accelerator Quality Assurance

Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)

Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...