Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun
Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute
Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...
Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...
Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield
Affiliation: GenesisCare
Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...
Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan
Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle
Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...
Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang
Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment
Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...
Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang
Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...
Authors: Niko Ahjoniemi, Antti Kulmala, Katja Peltola
Affiliation: Clinical Research Institute HUS, Helsinki University Hospital
Abstract Preview: Purpose: To determine the backlash of a multileaf collimator (MLC) using four measurement methods: motor encoder (primary readout), linear potentiometer (secondary readout), amorphous silicon panel (p...
Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago
Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...
Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...
Authors: Kaile Li
Affiliation: Alexander T. Augusta Miliary Medical Center
Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...
Authors: Pierre Gardair, Johnathan E Leeman, Claire Keun Sun Park, Atchar Sudhyadhom
Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School, Harvard Medical School
Abstract Preview: Purpose: Dose is a poor surrogate for radiobiological damage but no in vivo technology exists to directly measure damage such as DNA strand breaks and free radical generation (FRG). Recent advances in...
Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie
Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose:
The RefleXion® X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...
Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler
Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC
Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...
Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg
Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington
Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...
Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny
Affiliation: Department of Radiation Oncology, University of Rochester
Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...
Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger
Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie
Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...
Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka
Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...
Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler
Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC
Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...
Authors: Hongjing Sun, Weibing Yang, Timothy C. Zhu, Yifeng Zhu
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: This study aims to compare the commissioning results of TrueBeam and Halcyon linear accelerators with Monte Carlo (MC) simulations conducted using TOPAS. The ultimate goal is to leverage MC s...
Authors: Amy Fitzpatrick, Kim Howard, Julius G. Ojwang, Neelu Soni
Affiliation: Mercy Hospital Springfield
Abstract Preview: Purpose: This study evaluates the dosimetric advantages and workflow improvements of the CyberKnife S7 Precision Treatment Planning System (TPS) with the VOLO optimizer for stereotactic radiosurgery (...
Authors: Marcos Feijoo, Mamoru Ichiki, Tatsuya Maeda, Tatsuhiro Makino, Tomonori Megumi, Tadashi Nakabayashi, Yukino Nakata, Shuichi Ozawa, Daishi Takayama
Affiliation: Hiroshima High-Precision Radiotherapy Cancer Center, Blue Physics LLC, Imamura General Hospital, Accuray Inc.
Abstract Preview: Purpose: This study aims to accurately measure the leaf open time (LOT) of the multi-leaf collimator (MLC) in tomotherapy using an advanced plastic scintillator detector (PSD) with high time resolutio...
Authors: James L. Giltz, Michael J. Merrick
Affiliation: Alyzen Medical Physics, University of Kentucky
Abstract Preview: Purpose: To evaluate the capability of MyQA SRS in performing high-resolution machine QA to verify multileaf collimator (MLC) behavior and integrity for adaptive radiotherapy (ART). This study demonst...
Authors: Steve B. Jiang, Dan Nguyen, Chenyang Shen, Fan-Chi F. Su, Jiacheng Xie, Shunyu Yan, Daniel Yang, Ying Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas
Abstract Preview: Purpose: Fast dose verification is essential for the safety and efficiency of MR-guided adaptive radiotherapy (ART) as patients anxiously waiting on the treatment couch. Conventional tools often requi...
Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University
Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...
Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi
Affiliation: Komazawa University Graduate School, St. Luke's International Hospital
Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...