3D Printed Electron Block Aperture Generation

Authors: David Chighvinadze, Lisa Czaplicki, Jeremy D. Donaghue, Lama K. Muhieddine Mossolly

Affiliation: Cleveland Clinic Sandusky, Cleveland Clinic Strongsville, Cleveland Clinic Fairview

Abstract Preview: Purpose:
Current electron block generation requires manual cutting of stryofoam and placement for pouring of the block which can lead to possible miscutting of blocks, and non-accurate rotations co...

A Novel Setup for Flash Radiotherapy Beam Delivery at Isocenter Using Downstream Electron Scattering

Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts

Affiliation: University of Michigan, Oregon Health & Science University

Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...

Beam Characteristics of a Proposed Dielectric Wall Proton Accelerator Design

Authors: Julien Bancheri, Chau Giang Bui, Christopher M Lund, Morgan J Maher, Jamiel Nasser, Amy Parent, Monica Serban, Jan P. Seuntjens, Jason Z Yuan

Affiliation: University of Toronto, Medical Physics Unit, McGill University, Princess Margaret Cancer Centre, Princess Margaret Cancer Centre & University of Toronto

Abstract Preview: Purpose: Proton therapy (PT) has demonstrated greater precision and superior healthy tissue sparing compared to photon radiotherapy for various sites; however, PT systems are expensive, which limits g...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Imaging Based Surveys to Identify Leaks and Gaps in Radioisotope and Fluoroscopic x-Ray Shielding Barriers for Improved Shielding of Hospital Workers.

Authors: Nicholas Borges, Steven Brown, Jerimy C. Polf

Affiliation: H3D, inc, Massachusetts General Hospital, M3D, Inc

Abstract Preview: Purpose: To evaluate the potential of using real-time imaging and dose measurement to find weak spots and leaks in bedside shielding systems during diagnostic or interventional fluoroscopic procedures...

Impact of Tracking By Jaws or Mlc on Treatment Accuracy in Synchrony Modality for Tomohelical Technique

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Anthony Nagy, Stéphane Nevesny, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: Real-time tracking is implemented on Radixact by detecting the target position with 2D-kV image either directly (for lung tumors), or indirectly (using fiducials as surrogates), and by adapti...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...

Towards Higher Quality Breast Radiotherapy Treatments: A First Evaluation of the Newly Introduced Inframammary Fold Breast Wedge™ Device from Qlrad

Authors: Thomas Furno, Arjen Winkel, Ramtin Zakikhani

Affiliation: Genesis Care USA, QLRAD, SMH

Abstract Preview: Purpose: To quantify the dosimetric impact of the newly introduced “Inframammary Fold (IMF) Breast WedgeTM ” device by QLRAD inc. in the region of the inframammary fold during breast radiotherapy.
...