A Deep Learning Method for Direct Vmi Inference Using a Dual-Layer Radiotherapy Kv-CBCT Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: A challenge for dual energy CBCT is that noise and residual errors in material decomposition steps can become amplified when forming low energy, high contrast virtual mono-energetic images (V...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Characterization of Image Intensified Cherenkov Cameras for Development of Direct CMOS-Based Detection Systems

Authors: Petr Bruza, Eric R. Fossum, Alexander Geiersbach, David J. Gladstone, Karthik Raj Venkatesan

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Current Cherenkov imaging sensors rely on image intensifiers to generate sufficient signal for photon detection. While image intensifiers (IIs) exhibit good Cherenkov photon signal response, ...

Characterization of Linear Energy Transfer Spectra in Mini Beam Spatially Fractionated Proton Therapy

Authors: Serdar Charyyev, Kaan Dere, Edgar Gelover, Mohammad Khurram Khan, Liyong Lin, Mark McDonald, Cristina Oancea, Alexander Stanforth, Sibo Tian, Suk Whan (Paul) Yoon, Mingyao Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Stanford University, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Advacam

Abstract Preview: Purpose: The conventional implementation of proton spatially fractionated radiotherapy (SFRT) utilizes physical collimators with apertures to generate minibeams, creating alternating regions of high-d...

Comparative Analysis of Nine Deep Learning Architectures for Variable Density Grappa 1H Magnetic Resonance Spectroscopy Imaging (MRSI) Reconstruction

Authors: Kimberly Chan, Anke Henning, Mahrshi Jani, Andrew Wright, Xinyu Zhang

Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center

Abstract Preview: Purpose: To evaluate the performance of multiple deep learning architectures for MRSI reconstruction and determine their effectiveness in maintaining high-resolution metabolite mapping while reducing ...

Comparative Evaluation of Spekpy for Kilovoltage Beam Quality Characterization

Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park

Affiliation: Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...

Conversion Coefficients from Hp(10) to Organ and Effective Doses for Medical Staff Involved in Fluoroscopically Guided Interventional Procedures

Authors: Stephen Balter, Haegin Han, Cari M Kitahara, Taeeun Kwon, Choonsik Lee, Martha S Linet, Donald L. Miller

Affiliation: Columbia University Medical Center, National Cancer Institute, Food and Drug Administration

Abstract Preview: Purpose: Staff in fluoroscopically guided interventional (FGI) procedures are exposed to radiation. Inhomogeneous radiation fields and variability in procedural conditions make it challenging to deriv...

Dosimetric Impact of Monte Carlo Physics Models in Electronic Brachytherapy Simulations

Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Jan P. Seuntjens, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Princess Margaret Cancer Centre & University of Toronto, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta, Université Laval, Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University

Abstract Preview: Purpose: Low-energy X-ray beams used in electronic brachytherapy (eBT) pose unique dosimetric challenges due to high depth-dose gradients, material-dependent detector responses, and the absence of sta...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Geant4-DNA Simulation of Human Breast Cancer Cells Line MCF7 Irradiation with 213bi As Targeted Radionuclides

Authors: Hamid Abdollahi Nasehabad, Mehrangiz Amiri, Mohammad Reza Deevband, Faraz Kalantari, Milad Peer-Firozjaei, Ali Shabestani Monfared, Ehsan Tajikmansoury

Affiliation: Biomedical Engineering and Medical Physics Department, School of Medicine, Shahid Beheshti University of Medical Sciences, Department of Radiology, University of British Columbia, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, 1. Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose:
Targeted radionuclide therapy (TRNT) with 213Bi- labeled radiopharmaceuticals is a promising approach in targeted alpha and beta therapy for cancer. This study aims to assess double-strand...

Imaging Performance of Direct-Indirect Dual-Layer Flat-Panel-Detector Prototypes for Contrast-Enhanced Digital Mammography

Authors: Salman M. Arnab, Yves Chevalier, Samuel Gagné, Adrian F. Howansky, Luc Laperrière, Xiangyi Wu, Wei Zhao

Affiliation: Stony Brook Medicine, Analogic Canada

Abstract Preview: Purpose: A direct-indirect dual-layer flat-panel-detector (DI-DLFPD) is under development for patient motion artifact-free contrast-enhanced digital mammography (CEDM). DI-DLFPD comprises a direct fro...

Lu-177 Recovery Coefficients Using Tc-99m Surrogate Method: Intra- & Inter-Scanner Comparison

Authors: Ben Piacitelli, Celeste Winters

Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...

Modeling of Novel Converging Beam Radiotherapy System in Geant4 Montel Carlo Simulation

Authors: Dirk A Bartkoski, Leonard Che Fru, Benjamin Abraham Insley, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour, Aviad Schori, Ramesh C. Tailor

Affiliation: Empyrean Medical Systems, The University of Texas MD Anderson Cancer Center, Convergent-RnR, The University of Texas, MD Anderson, Houston TX

Abstract Preview: Purpose: A Geant4-based model was created for a G4BraggReflection process to simulate radiation transport within a novel radiotherapy system developed by Convergent Radiotherapy and Radiosurgery (CRnR...

Non-Invasive Photoacoustic Thermometry for Real-Time Monitoring of Tissue Temperature Using Frequency Analysis

Authors: Hisham Assi, Lexi Dowdy, Muhannad N. Fadhel, Michael C. Kolios, Carl Kumaradas, Rasha S Makkia, Tanay N Mannikar

Affiliation: Toronto Metropolitan University, Augusta University, Institute for Biomedical Engineering, Science and Technology (iBEST), Li Ka Shing Knowledge Institute, St. Michael’s Hospital, Northwestern University, Medical College of Georgia, Augusta University

Abstract Preview: Introduction: Hyperthermia is an emerging strategy for cancer treatment due to its few side effects and low cost. Hyperthermia is used in conjunction with other treatments, such as radiation therapy, ...

On Designing a Vascular Flow Phantom for Contrast-Enhanced Ultrasound Imaging

Authors: Kevin M Brom, Josep Chorro Bas, RosaAnna Chorro Bas, Andres Climent Rubio, Jaydev K. Dave, Tobias Kummer, Larissa Shiue, Donald J Tradup

Affiliation: Mayo Clinic, Prehospital Critical Care Training Group

Abstract Preview: Purpose: To design and evaluate the functionality of a vascular flow phantom for contrast-enhanced ultrasound imaging (CEUS).

Methods: A microcontroller-generated signal was amplified by a cust...

Quantification of Iodine and Calcium Materials through HU Spectral Curve Analysis in Dual-Energy CT for Radiotherapy Planning

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Maria F. Chan, Yabo Fu, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Lee, Tianfang Li, Xiang Li, Jean M. Moran

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Iodine maps derived from Dual-Energy CT (DECT) provide critical biological information for radiotherapy treatment planning, but clinical iodine maps often mistakenly include bones due to insu...

Tin-Filtered Spectral Shaping Technique in Clinical Photon-Counting CT: Impact on Noise Magnitude By Object Size, Radiation Dose, and Spectral Reconstruction Type

Authors: Xinhui Duan, Vivek Nair, Liqiang Ren, KyuHo Song, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center

Abstract Preview: Purpose: To evaluate how tin-filtered spectral shaping in clinical photon-counting computed tomography (PCCT) affects noise magnitude across varying object sizes, radiation doses, and spectral reconst...

Validation of a Simulation Tool and in-Silico Assessment of Low Contrast Detectability for Super-Resolution Deep Learning Reconstruction

Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin

Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA

Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...