A 2D Discrete Ionization Chamber Array for Proton Pencil Beam Scanning Flash Dosimetry

Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou

Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica

Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...

A Deep Learning-Based Method for Rapid Generation of Spot Weights in Single Field Optimization for Proton Therapy in Prostate Cancer

Authors: Yu Chang, Mei Chen

Affiliation: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine

Abstract Preview: Purpose: Spot weights optimization, as a critical step in the proton therapy, is often time-consuming and labor-intensive. Deep learning, with its powerful learning and computational efficiency, can e...

A Dosimetric Study of Range-Compensated Proton Arc Therapy

Authors: Alonso N. Gutierrez, Daniel E. Hyer, Blake R. Smith

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To perform a feasibility study of optimizing and producing a compact range compensator to deliver single-energy pencil beam scanning (PBS) proton arc therapy treatments. Omitting energy chang...

A Hybrid 4π-Proton Arc Robust Optimization

Authors: Wenhua Cao, Xianjin Dai, PhD, Hadis Moazami Goudarzi, Gino Lim, Miaolan Xie, Lei Xing, Lewei Zhao

Affiliation: University of Chicago Booth School of Business, Department of Radiation Oncology, Stanford University, Department of Industrial Engineering, University of Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) delivers a continuous dose of radiation during gantry rotation. 4π is a non-coplanar technique used for advanced proton therapy delivery. This work proposes a hybrid ...

A Novel Lattice Technique Based Spot Scanning Proton Arc Therapy Via Spot Sparsity Optimization and LET Optimization

Authors: Zhitao Dai, Riao Dao, Xuanfeng Ding, Qingkun Fan, Yajun Jia, Gang Liu, Gang Peng, Yujia Qian, Hong Quan, Kunyu Yang, Sheng Zhang, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Corewellhealth William Beaumont University Hospital, School of Mathematics and Statistics, Wuhan University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Chinese Academy of Medical Sciences Cancer Hospital Shenzhen Hospital, School of Physics and Technology,Wuhan University, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: Lattice radiation therapy (LRT) is an innovative three-dimensional(3D) implementation type of spatially fractionated radiation therapy (SFRT). This study aims to develop a novel spot-scanning...

Adaptive Proton Flash Therapy through Iterative Modular Pin Recycling

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
We propose a method to optimize adaptive proton FLASH therapy (ADP-FLASH) using modularized pin-ridge filters (pRFs) by recycling module pins from the initial plan, reducing pRF adjustment...

Attention-Based Multiple Instance Learning of Head and Neck Cancer Grading on Digital Pathology Using Vision-Language Foundational Models

Authors: Kyle J. Lafata, Xiang Li, Megan K. Russ, Zion Sheng

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: To adapt Vision-Language Foundational Models (VLFM) to perform HNSCC tumor grading on H&E whole slide images (WSI) via attention-based multiple instance learning (ABMIL).
Methods: We utili...

Automated IMPT Treatment Planning for CSI: Enhancing Efficiency with Auto-Segmentation and Scripting

Authors: Katja M. Langen, William Andrew LePain, Robert Muiruri, Vivi Nguyen, Mosa Pasha, Roelf L. Slopsema, Alexander Stanforth, Yinan Wang, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) treatment planning for craniospinal irradiation (CSI) is complex and requires extensive effort from the planner. This study aims to enhance planning ...

Automated Quantitative Method for Source Position Calculation in Annual Quality Assurance of High Dose Rate Brachytherapy Gynecological Applicators

Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...

BEST IN PHYSICS MULTI-DISCIPLINARY: Evaluation of Spot-Level N-12 PET Imaging for Online Range Verification in Multi-Field Intensity Modulated Proton Therapy

Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos

Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen

Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...

BEST IN PHYSICS MULTI-DISCIPLINARY: Motion-Resolved Dynamic CBCT Reconstruction Using Prior-Model-Free Spatiotemporal Gaussian Representation (PMF-STGR)

Authors: Hua-Chieh Shao, Chenyang Shen, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Motion-resolved CBCT imaging, which reconstructs a dynamic sequence of CBCTs reflecting intra-scan motion (one CBCT per x-ray projection), is highly desired for regular/irregular motion chara...

Box-Prompt Zero-Shot Smart Segmentation in Radiation Oncology Using a SAM-Based Model: Smartsam

Authors: Kristen A. Duke, Samer Jabor, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia

Affiliation: St. Mary's University, The University of Texas San Antonio, UT Health San Antonio

Abstract Preview: Purpose:
The Segment Anything Model (SAM) is a foundational box-prompt-based model for natural image segmentation. However, its applicability to zero-shot 3D medical image segmentation, particularl...

CNN-Based Reconstruction for 3D Scintillation Dosimetry of Proton Pencil Beams

Authors: Sam Beddar, Jason Michael Holmes, Daniel G. Robertson, James J. Sohn, Ethan D. Stolen

Affiliation: Department of Radiation Oncology, Mayo Clinic, MD Anderson Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago

Abstract Preview: Purpose: Camera-based scintillation dosimetry incorporating large volumes have shown promise for fast and comprehensive evaluation of external beam treatment fields. While some efforts have been made ...

Case-By-Case Analysis of Proton Spot Spacing and Dosimetric Variability in Proton Arc Lung Cancer Planning

Authors: Nebi Demez, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Umesh Rana, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: DynamicARC is an advanced proton therapy technique that leverages pencil beam scanning to deliver dose to the patient while the gantry rotates around the patient. This study investigates the ...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Clinically Ready Simulation Package for Monitoring Gamma Hotspot Emission, and Detection in Patient Anatomy

Authors: Ananta Raj Chalise, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: Prompt gamma (PG) imaging is a promising modality for proton dose verification. Currently, there is a lack of effective tool to investigate the PG emission during proton therapy and optimize ...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Comparison of Frame-Based and Frameless Gamma Knife Coordinate Spaces for Treatment of Trigeminal Neuralgia

Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...

Deep Learning-Based Prompt Gamma Imaging for Proton Range Verification Using Patient Data Simulation

Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma

Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC

Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Development of Treatment Planning System for Carbon Ion Radiotherapy in Yonsei Cancer Center

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojin Kim, Jin Sung Kim, HO Lee, Sac Lee, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) offers the advantage of a greater relative biological effectiveness (RBE) weighted dose, which must be integrated into the treatment planning system (TPS). This...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Dose Rate Measurements of Scanning Carbon Ion Beams Using a Plastic Scintillator Detector

Authors: Motohiro Kawashima, Adrian Kugara, Masao Nakao, Shuichi Ozawa, Mutsumi Tashiro, Maria Varnava

Affiliation: Gunma University Heavy Ion Medical Center, Hiroshima High-Precision Radiotherapy Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the time-dependent dose rate characteristics of a scanning carbon ion beam using a fast-response plastic scintillator detector (PSD), with a focus on its potentia...

Dosemorph: A Study on Few-Shot Learning and Dose-Anatomy Registration for Radiotherapy Optimal Dose Prediction in Cervical Cancer

Authors: Xiance Jin

Affiliation: 1st Affiliated Hospital of Wenzhou Medical University

Abstract Preview: Purpose:
Deep learning deformable registration models was proposed to predict optimal dose distributions a with a few of optimal planned doses using a few-shot learning for cervical cancer.
Meth...

Dosimetric Assessment of Spatially Fractionated Radiation Therapy on Prostate Cancer Cases: Our Experience in Nsia-Luth Cancer Center, Lagos

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Sylvester Entonu, Muhammad Habeebu, Adedayo O. Joseph, Oluwaseyi Oderinde, Oluwadara Ojediran, Margaret Dideolu Taiwo

Affiliation: University of Ibadan, University of Lagos, Missouri University of Science and Technology, Purdue University, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre

Abstract Preview: Purpose:
Spatially Fractionated Radiation Therapy (SFRT) is an advanced radiotherapy technique designed to deliver highly heterogeneous radiation doses, aiming to optimize tumor control while minim...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectors™ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Effects of Plan Optimization Techniques on Relative Biological Effective Dose in a Thin Intracranial Target Volume

Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center

Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...

Evaluating the Impact of Spot Spacing on Dosimetric Outcomes in Dynamic Arc Proton Therapy for Prostate SBRT

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Umesh Rana, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: DynamicARC is a novel pencil beam scanning (PBS) proton therapy technique with the potential to provide more conformal dose distributions and reduce treatment time. This study investigates th...

Evaluation of Fast Monte Carlo Secondary Dose Calculation for Intensity Modulated Proton Therapy in Heterogeneous Materials

Authors: Ergun E. Ahunbay, Abdul Kareem Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao

Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Secondary dose calculations (SDC) facilitate patient-specific quality assurance for online adaptive intensity-modulated proton therapy (IMPT). However, there is currently a lack of commercial...

Feasibility Study of Group Sparse-Based Beam Angle Optimization for Multi-Field Carbon Ion Radiotherapy

Authors: Min Cheol Han, Hojin Kim, Jin Sung Kim, Hyejin Lee, Sac Lee, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) is characterized by high relative biological effectiveness (RBE), which must be integrated into the treatment planning process. This study aims to develop a nov...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Free-Breathing Spirometer-Gated Proton Pencil Beam Scanning Delivery Maintains Tumor Coverage with Improved Organ-at-Risk Sparing: A Motion Phantom Validation

Authors: Uriel Aura, Qing Chen, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Meng Wei Ho, Sheng Huang, Minglei Kang, Stanislav Lazarev, Nancy Y Lee, Yang Lei, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Anna Zhai, Ajay Zheng

Affiliation: DYN'R Medical System, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Tianjin Medical University Cancer Institute&Hospital, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Managing tumor motion during pencil beam scanning proton therapy remains challenging. This study investigated the feasibility and dosimetric benefits of Free-Breathing Respiratory-Gated Deliv...

Fully Automated Zero-Shot Organ Segmentation in Male Pelvic MR Images for MR-Guided Radiation Therapy

Authors: Jihun Kim, Jin Sung Kim, Jun Won Kim, Yong Tae Kim, Chanwoong Lee, Jihyn Pyo, Young Hun Yoon

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Although segmentation foundation models have recently demonstrated promising zero-shot performance on natural images, its clinical application to magnetic resonance (MR) images still requires...

Imaging Based Surveys to Identify Leaks and Gaps in Radioisotope and Fluoroscopic x-Ray Shielding Barriers for Improved Shielding of Hospital Workers.

Authors: Nicholas Borges, Steven Brown, Jerimy C. Polf

Affiliation: H3D, inc, Massachusetts General Hospital, M3D, Inc

Abstract Preview: Purpose: To evaluate the potential of using real-time imaging and dose measurement to find weak spots and leaks in bedside shielding systems during diagnostic or interventional fluoroscopic procedures...

Improving Output Stability with Angular Correction Factor on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate the effectiveness of angular correction factor for output stability on Mevion S250i Hyper scanning machine, which allows user to apply correction factors for output at selected ga...

Improving TG-263 Target Name Compliance Using Locally-Hosted Large Language Models

Authors: Rex A. Cardan, Carlos E. Cardenas, Udbhav S. Ram

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: The AAPM TG-263 report provides nomenclature guidelines for target and normal tissue structures used in radiation oncology. Adherence to these guidelines is challenging for targets, as there ...

Initial Three-Year Machine Performance Assessment of a Superficial Radiation Therapy Unit

Authors: Vibha Chaswal, Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, William Romaguera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: To report machine performance of our superficial radiation therapy unit (SRT-100 Vision, Sensus Healthcare, Boca Raton, FL) for the first three years after commissioning of the unit.
Metho...

Investigation of a Novel Snout-Mounted Compton Camera System for Monitoring Dose Depth

Authors: Ananta Raj Chalise, Matthias K Gobbert, Hajar Moradmand, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, University of Maryland, Baltimore County, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: We are developing a novel Compton Camera (CC) system mounted orthogonally on the treatment nozzle for prompt gamma (PG) imaging-based proton range verification during treatment. This study in...

Isocenter Stability after Commissioning of Biology-Guided Radiotherapy (BgRT)

Authors: Emily Hansen, Alois M. Ndlovu, Niara Rowe, Roland Teboh

Affiliation: Hackensack University Medical Center

Abstract Preview: Purpose: The accuracy of SCINTIX biology-guided radiotherapy (BgRT) on the RefleXion X1 is dependent on the correct alignment of the isocenter between all subsystems, including setup lasers, kV imagin...

Large Language Model-Driven Agentic System for Collaborative Decision-Making in Radiotherapy Treatment Planning

Authors: Yang Sheng, Qingrong Jackie Wu, Qiuwen Wu, Xin Wu, Dongrong Yang

Affiliation: Duke University Medical Center

Abstract Preview: Purpose:
This study aims to leverage large language model (LLMs) to develop a human-in-the-loop agentic framework, enhancing the efficiency of treatment planning in radiotherapy.
Methods:
A L...

Leveraging Hybrid Quantum Solvers for Eye Plaque Brachytherapy Treatment Planning Optimization

Authors: Xianjin Dai, PhD, Wu Liu, Eric Nguyen, Lei Xing, Lewei Zhao

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: Recent developments in hybrid quantum solvers, which combine quantum and classical processing, enable greater flexibility to tackle problems outside the limited scope of pure quantum computin...

Linac Based Dose-Escalated Radiation Therapy for Pancreatic Cancer: Assessing Respiratory Motion

Authors: Neal Andruska, Lianna D. DiMaso-Myers

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: To provide details on how our clinic assesses respiratory motion during treatment of a pancreatic adenocarcinoma during dose escalated radiation therapy on a linear accelerator with the aid o...

Log-Based Predictive Modeling of the Dynamic Collimation System (DCS) Trimmer Dynamics for Efficient Proton Pbs Delivery

Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Ryan Gardner, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care

Abstract Preview: Purpose: To develop an accurate predictive temporal model for the movement of Dynamic Collimation System (DCS) trimmers during collimated proton pencil beam scanning (PBS) deliveries using log data. T...

Modeling of Novel Converging Beam Radiotherapy System in Geant4 Montel Carlo Simulation

Authors: Dirk A Bartkoski, Leonard Che Fru, Benjamin Abraham Insley, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour, Aviad Schori, Ramesh C. Tailor

Affiliation: Empyrean Medical Systems, The University of Texas MD Anderson Cancer Center, Convergent-RnR, The University of Texas, MD Anderson, Houston TX

Abstract Preview: Purpose: A Geant4-based model was created for a G4BraggReflection process to simulate radiation transport within a novel radiotherapy system developed by Convergent Radiotherapy and Radiosurgery (CRnR...

Optimal Lattice Design for Spatially Fractionated Radiotherapy (SFRT) of Brain Metastasis in Gamma Knife (GK)

Authors: Brankica Andelic, Young-Bin Cho, Tara M. Gray, Andrew Robert Hadfield, Hakan Nordstrom

Affiliation: Elekta, Cleveland Clinic

Abstract Preview: Purpose: Spatially Fractionated Radiotherapy (SFRT) requires highly modulated dose distribution inside a tumor volume optimized using sets of planning structure of spheres in a lattice arrangement. To...

Optimizing Motion Profiles of a Dynamic Collimator in Proton Therapy

Authors: Simona Cacciatore, Albert Du, Ryan T. Flynn, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Julien Smeets, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care

Abstract Preview: Purpose: To evaluate time reduction strategies for the Dynamic Collimation System (DCS) using an IBA (Louvain-la-Neuve, Belgium) proton therapy system. Delivery time for a multi-energy-layer patient s...

Personalized Radiotherapy: A Novel Approach to Multi-Criteria Optimization with Patient-Specific Risk Integration

Authors: Ali Ajdari, Thomas R. Bortfeld, Zhongxing Liao, Mara Schubert, Katrin Teichert

Affiliation: The University of Texas MD Anderson Cancer Center, Department Of Radiation Oncology, Massachusetts General Hospital (MGH), Massachusetts General Hospital & Harvard Medical School, Fraunhofer ITWM

Abstract Preview: Purpose: Radiotherapy (RT) treatment planning often involves solving a multi-criteria optimization (MCO) problem. Conventionally, MCO considers a set of generic (population-wide) dosimetric criteria, ...

Reducing Variable Rbe in Oars for HN, Breast, and Prostate Proton Therapy Using a Scripted Spot-Delete Technique

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey

Affiliation: Thompson Proton Center

Abstract Preview: Purpose: Linear energy transfer (LET) and variable relative biological effectiveness (RBE) evaluation are important steps in the future of proton therapy, moving beyond RBE=1.1 for all treatment plann...

Transformations of the Coordinate System for Monte Carlo Dose Calculations of Spot Scanning Proton Therapy

Authors: Hongyu Jiang

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: This study presents a method for transforming coordinates from RayStation’s treatment planning system into the Monte Carlo (MC) coordinate system used in GEANT4 for dose calculations in spot ...