Search Submissions 🔎

Results for "level beams": 63 found

A Dual Energy CT-Guided Intelligent Radiation Therapy Platform

Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...

A New Way to Assess Dynamic Response of Centrally Located Lung Cancer (CLLC) to SBRT and Conventional Radiation Therapy (CRT)

Authors: Nina Burbure, Tawfik Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital, Dept. of Radiation Oncology, Fox Chase Cancer Center at Temple University Hospital

Abstract Preview: Purpose: Higher rates of local failures and toxicities challenged radiation therapy of centrally located lung cancer (CLLC). We assessed the treatment response by measuring the early changes of PET+ n...

A Novel Design of Photon-Counting Static Cone-Beam CT System for Dedicated Breast Imaging

Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...

A Pilot Survey on Medical Physics Residency Education in External Beam Special Procedures

Authors: Courtney R. Buckey, Jay W. Burmeister, Minsong Cao, Grace Chang, Yu Kuang, Yixiang Liao, Yi Rong, Dandan Zheng

Affiliation: Mayo Clinic, Mayo Clinic Arizona, Karmanos Cancer Center, Gershenson ROC, Wayne State University School of Medicine, Department of Radiation Oncology, University of California, Los Angeles, Medical Physics Program, University of Nevada, Rush University Medical Center, University of Rochester

Abstract Preview: Purpose: Investigate the adequacy of training for therapeutic medical physics residents in select special procedures.
Methods: After a review of existing literature, a multi-institutional group dev...

A Simplified, Rigorous Procedure for Ultrasound Quality Assurance

Authors: Paul L. Carson, Sander Dekker, Stephen Z Pinter, Megan K. Russ

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Michigan, Cablon Medical B.V., Univ of Michigan, Dept. of Radiology

Abstract Preview: Purpose:
To promote a simplified, inexpensive, but rigorous set of ultrasound QA tests and to evaluate their potential using a Randomly-placed very Hypoechoic Sphere Phantom (RHSP) in comparison to...

Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Automated Determination of Deteriorations in Proton Therapy Plan Quality Using Daily Cone Beam CT As a Predictor of Need for Adaptive Replans for Head and Neck Cases

Authors: Matthew J Ferris, Jason K Molitoris

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland

Abstract Preview: Purpose: Anatomy changes often happen in head-and-neck (HN) patients treated with proton radiation therapy. These changes can result in deteriorations of target dose coverage and increased dose to org...

Automated Treatment Planning for Stereotactic Recurrent Head and Neck Cancers Using Knowledge-Based Planning, Multicriteria Optimization, and Dosimetric Scorecards

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstration of automated stereotactic treatment planning for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecard...

BEST IN PHYSICS MULTI-DISCIPLINARY: Evaluation of Spot-Level N-12 PET Imaging for Online Range Verification in Multi-Field Intensity Modulated Proton Therapy

Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos

Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen

Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...

BEST IN PHYSICS THERAPY: Impact of Local Tissue Oxygenation Level on the Flash Effect in Murine Skin

Authors: David J. Gladstone, P. Jack Hoopes, David I Hunter, Brian W Pogue, Jacob Pierce Sunnerberg, Armin Tavakkoli

Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Geisel School of Medicine, Dartmouth College

Abstract Preview: Purpose: The FLASH effect, characterized by normal tissue sparing under ultra-high dose rate (UHDR) radiation delivery, remains mechanistically unclear. This study investigated the relationship betwee...

CBCT-Based Radiomics of Head and Neck Cancer for Predicting Patient Toxicity to Radiotherapy

Authors: Rodrigo Delgadillo, Nesrin Dogan, Benjamin J. Rich, Stuart E Samuels, Levent Sensoy

Affiliation: University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Daily Cone beam CT (CBCT) images may be useful in detecting early morphological changes during head and neck cancer radiotherapy. The aim of this study was to evaluate the performance of CBCT...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Cherenkov Image Denoising with Diffusion-Based Deep-Learning for High-Fidelity Video Display of EBRT

Authors: Petr Bruza, Jeremy Eric Hallett, Brian W Pogue, Yucheng Tang, Shiru Wang

Affiliation: NVIDIA Corp, Dartmouth College, Thayer School of Engineering, Dartmouth College, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: Cherenkov imaging allows for real-time visualization of megavoltage X-ray or electron beam delivery during radiation therapy. By using a time-gated intensified CMOS camera synchronized with a...

Clonogenic Assays for Three Prostate Cancer Cell Lines with Varying Levels of DNA Repair Mutations Treated with LET-Optimized Pencil Beam Scanning Protons and Evaluation of Dose Rate Effect

Authors: Mark E Artz, Jiyeon Park, Lori Rice, Mohammad Saki, Sanjeev Shukla, Michael Vieceli

Affiliation: University of Florida Health Proton Therapy Institute, Department of Radiation Oncology, University of Florida College of Medicine, UF Health Proton Therapy Institute, Department of Urology, University of Florida College of Medicine

Abstract Preview: Purpose: To investigate how varying levels of DNA repair mutations affect the LET sensitivity of prostate cancer cells.
Methods: The prostate cancer cell lines Du145 (low DNA repair mutations), PC3...

Commissioning Radcalc v7.3 with a Collapsed Cone Calculation Algorithm for 6X FFF and 10X FFF Energies

Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...

Deep Learning-Based Prompt Gamma Imaging for Proton Range Verification Using Patient Data Simulation

Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma

Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC

Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...

Deployable Twin-Calorimeter System for Absolute Dose Measurements By Clinical Physicists

Authors: Jean Dessureault, Malcolm R. McEwen, Bryan R. Muir, James Renaud

Affiliation: National Research Council

Abstract Preview: Purpose: To develop and commission a mailable calorimeter that enables clinical medical physicists to quickly and efficiently address innovative dosimetry challenges directly at the point of use.
<...

Differential Gastrointestinal Responses to Synchrotron-Produced Proton and Electron Irradiation Under Flash and Conventional Conditions

Authors: Luke Connell, Nolan M. Esplen, Elise Konradsson, Albert C. Koong, Ziyi Li, Steven Hsesheng Lin, Kevin Liu, Billy W Loo, Devarati Mitra, Radhe Mohan, Emil Schueler, Takeshi Takaoka, Uwe Titt, Xiaochun Wang, Ming Yang

Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study aimed to assess radiation-induced gastrointestinal (GI) toxicity in mice subjected to abdominal irradiation using protons at ultra-high-dose-rate (UHDR) and conventional dose-rates...

Dose Reconstruction from Prompt-Gamma Imaging Towards Real-Time Adaptive Proton Therapy

Authors: Thomas R. Bortfeld, Prof. Elisabetta De Bernardi, Tianxue Du, Beatrice Foglia, Chiara Gianoli, Takamitsu Masuda, Katia Parodi, Marco Pinto, Boon-Keng Kevin Teo, Yunhe Xie

Affiliation: Department Of Radiation Oncology, Massachusetts General Hospital (MGH), School of Medicine and Surgery, University of Milano-Bicocca, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, National Institutes for Quantum Science and Technology (QST), University of Pennsylvania, Department of Experimental Physics - Medical Physics, Ludwig-Maximilians-Universität (LMU) München

Abstract Preview: Purpose: The full potential offered by protons in clinical practice is limited by range uncertainties. One possibility for monitoring is through secondary prompt gammas (PG). PG emission along the pen...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectors™ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Dual Energy Cone Beam Computed Tomography for Artifact Reduction and Enhanced Image Quality Using Existing Hardware in Radiation Therapy

Authors: Michael J. Choi, Vindu Wathsala Kathriarachchi, Christopher L. Nelson, Andrew P. Soderstrom, Yawei Zhang

Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, UF Health Proton Therapy Institute

Abstract Preview: Purpose: Cone Beam Computed Tomography (CBCT) is widely used in image-guided radiation therapy for patient positioning. While kV photons offer high image contrast, they are prone to artifacts caused b...

Eclipse AFI Manual Planning Versus Brainlab Auto-Planning: A Comparison of SRS Plan Quality

Authors: Dharmin D. Desai, Ellis Lee Johnson, Philip J. Kallenberg, Kapil M. Mishra

Affiliation: Spectrum Medical Physics, University of Kentucky, Varian Advanced Oncology Solutions

Abstract Preview: Purpose: The “Ask For It” (AFI) manual optimization strategy has been shown to generate high quality SRS plans within Eclipse. The purpose of this work is to directly compare manually generated Eclips...

Efficient FAST-Forward Planning Strategy for X-Ray Based Online Adaptive Radiotherapy

Authors: Prasanna Alluri, Mona Arbab, Xingzhe Li, Chang-Shiun Lin, Mu-han Lin, David D.M. Parsons, Asal Rahimi, Justin D. Visak, Narine Wandrey

Affiliation: UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: Intelligence-Optimization-Engine (IOE) v1.0 relied heavily on planner expertise and patient-specific IMRT beam arrangements, requiring frequent revisions. While VMAT workflows offered potenti...

Evaluating Discrete Proton Arcs Converted to Pencil Beam Scanning Plans for Glioma and Chordoma in Raystation with a Mevion s250i Hyperscan Proton Therapy System

Authors: Mark A. Newpower, Jill Taylor

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: RayStation 2024A allows planners to optimize intensity modulated proton therapy (IMPT) plans using discrete arcs which can then be converted to traditional pencil beam scanning (PBS) beams fo...

Evaluating the Capabilities of Hypersight CBCT for Advanced Dual-Energy CBCT Imaging in Online Adaptive Radiotherapy

Authors: Yi-Fang Wang, Yading Yuan

Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center

Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...

Evaluating the Impact of Beam Spot Spacing on Dose Rates and Field Uniformity for Small Animal Proton Ultra-High Dose Rate Irradiation

Authors: Jack Biondo, Audrey Magness, Anthony E. Mascia, Zhiyan Xiao, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center

Abstract Preview: Purpose: Proton FLASH-RT has shown promise reducing normal tissue toxicity while maintaining tumor control. However, in vivo experiments critically depend on achieving ultra-high dose rate (UHDR) and ...

Evaluating the Interchangeability of Two Similar but Not Beam-Matched Varian Truebeam Linear Accelerators in the Delivery of Patient-Specific Quality Assurance

Authors: Elizabeth M. Alves, Alistair K. Templeton, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To test the performance of two similar, but not beam-matched, linacs in interchangeably delivering IMRT and VMAT patient-specific quality assurance (PSQA) tests.
Methods: Two TrueBeam lina...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Feasibility of Efficient Offline Adaptive Replanning with Hypersight High-Performance Cone-Beam CT on Truebeam for Pelvis RT

Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang

Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...

First Demonstration of Prostate Radiotherapy Plan Optimization on an IBM Quantum Computer

Authors: Keisuke Fujii, Masahiro Kitagawa, Arezoo Modiri, Yuichiro Nakano, Ken N. Okada, Robabeh Rahimi, Akira SaiToh, Amit Sawant, Satoyuki Tsukano, Baoshe Zhang

Affiliation: University of Maryland, University of Maryland in Baltimore, Department of Computer and Information Sciences, Sojo University, Center for Quantum Information and Quantum Biology, Osaka University, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: Fully personalized radiotherapy requires computational resources far exceeding those of conventional CPU/GPU systems. This study explores the use of quantum computing (QC) in radiotherapy pla...

Frameless and Maskless Stereotactic Radiosurgery: Evaluating a Novel Robotic Head Motion Compensation Device

Authors: Michelle Alonso-Basanta, Carl Denis, Wenbo Gu, Xinmin Liu, Ahmad Sakaamini, Rodney D. Wiersma

Affiliation: UCLA, University of Pennsylvania, CDR Systems

Abstract Preview: Purpose: Stereotactic radiosurgery (SRS) is a non-invasive technique used to treat functional abnormalities and small brain tumors. Traditional SRS relies on a rigidly fixed metal head ring, causing d...

Immune Response on Ultra-High Dose Rate (FLASH) and Conventional Proton Radiation in a Mouse Xenograft Model

Authors: Ning Cao, Sunan Cui, Danielle P. Johnson Erickson, Juergen Meyer, Ramesh Rengan, Ben A Shaver, Jing Zeng

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington and Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: To investigate the immune response in primary irradiated tumors and non-irradiated tumors in a mouse melanoma xenograft model, comparing 18Gy of conventional (CONV) and ultra-high dose rate (...

Implementation of a Visual Feedback System for Respiratory Gated Intensity Modulated Proton Therapy

Authors: Shen Fu, Jun Hou, Zuofeng LI, Taize Yuan, Qingyuan Zhang, Yuanshui Zheng

Affiliation: GuangZhou Concord Cancer Center, Guangzhou Concord Cancer Center, 广州泰和肿瘤医院

Abstract Preview: Purpose: A visual feedback system is beneficial for patients to maintain consistent respiratory signal during gated radiotherapy, especially for intensity modulated proton therapy (IMPT) where motion ...

Initial Phantom Studies Towards Implementation of Sequential Dual Energy CBCT on an Adaptive Radiotherapy Linac Platform

Authors: James M. Balter, Alexander Moncion, Ikechi S Ozoemelam

Affiliation: University of Michigan

Abstract Preview: Purpose: Sequential dual-energy cone beam computed tomography (DE-CBCT) integrated with an online adaptive platform could potentially improve soft tissue visualization for more accurate anatomical del...

Inverse Geometry Photon Counting CBCT

Authors: Saree Alnaghy, Owen Thomas Dillon, Sean P Hood, Paul J. Keall, Ricky O'Brien, Tess Reynolds

Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney, University of Wollongong, Medical Radiations, School of Health and Biomedical Sciences, RMIT University

Abstract Preview: Purpose: Photon Counting Detectors (PCDs) have been demonstrated to improve resolution, contrast and lesion detectability in fan-beam CT. There is naturally a desire to bring these improvements to Con...

Investigation of Fluorescent Probes for Real-Time ROS Detection Under Flash Radiotherapy

Authors: Yuqi Yang, Fang-Fang Yin

Affiliation: Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Reactive oxygen species (ROS) are unstable molecules which play important roles in the cellular process after Flash radiotherapy. The rapid changes in ROS levels during treatment may provide ...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Memory-Efficient Deep Learning for Volumetric Cone-Beam CT Image Reconstruction

Authors: Ziqi Gao, Lei Xing, Siqi Ye, S. Kevin Zhou

Affiliation: Department of Radiation Oncology, Stanford University, University of Science and Technology of China (USTC)

Abstract Preview: Purpose: To address the challenge of high memory usage in volumetric cone-beam CT (CBCT) imaging, we propose a method that combines joint reconstruction and super-resolution for sparsely sampled CBCT ...

Multi-Center Evaluation of an AI Beam Angle Prediction Model for Liver Treatments Using Pencil Beam Scanning Proton Therapy

Authors: Christopher Ackerman, Chang Chang, Yan-Cheng Huang, Robert Kaderka, Che Lin, Hsin-Chih Lo, Iain MacEwan, Yi-Chin Tu, James Urbanic

Affiliation: University of California San DIego, Taiwan AI Labs, National Taiwan University, California Protons Cancer Therapy Center, University of Miami, Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: To investigate the performance of an existing AI beam angle prediction model on external patient datasets for liver proton treatments. The AI model was trained on datasets exclusively from on...

Non-Planar Narrow-Beam CT: Near Scatter-Free, High-Resolution Breast Imaging at Screening Mammography Doses.

Authors: Peymon Ghazi

Affiliation: MALCOVA Inc.

Abstract Preview: Purpose: To develop a near scatter‐free breast CT imaging system that expands coverage of the posterior breast anatomy and enhances contrast resolution for solid masses and microcalcifications, while ...

Novel Approach to Improve Treatment Planning Process for Mixed Fractionation Schemes on ZAP-X

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: Using mixed fractionation schemes is a common technique in treating CNS lesions. This article describes an innovative plan-and-split approach for more efficient planning on the ZAP-X and thus...

Optimized Methodology for Accurate Half-Value Layer Measurement in Preclinical X-Ray Cabinet Systems

Authors: Paolo Pellicioli, Mohammad Rezaee, Ehsan Tajikmansoury, John W. Wong

Affiliation: Institute of Anatomy, University of Bern, Baltzerstrasse, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose: Half-value layer (HVL) is a critical parameter for commissioning and quality assurance of preclinical x-ray irradiators. However, measuring HVL in cabinet systems presents challenges due to s...

Optimizing Timing of Physics Consults for Proton Prostate Therapy: Improving Patient Experience and Operational Efficiency

Authors: Charles D. Bloch, Stephen R. Bowen, Bing-Hao Chiang, Alex Egan, Eric C. Ford, Sharareh Koufigar, Dominic A. Maes, Juergen Meyer, Sharon Pai, Frank Rafie, Rajesh Regmi, Jatinder Saini, George A. Sandison, Marco Schwarz, Bishwambhar Sengupta, Tony P. Wong

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington

Abstract Preview: Purpose: This study aimed to optimize the strategy and timing of physics consults for proton prostate patients to improve the patient experience and resource utilization in our radiation oncology depa...

PCA-Based Future Frame Prediction for Real-Time MRI-Guided Radiotherapy

Authors: B. Gino Fallone, Gawon Han, Keith D. Wachowicz, Mark G. Wright, Eugene Yip, Jihyun Yun

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com

Abstract Preview: Purpose: MRI-radiotherapy hybrid systems can guide the therapeutic beam, dynamically adjusting to a moving tumor in real-time. However, there is a time delay from imaging and beam control, requiring p...

Performance of Photon Counting Detector in a Clinical PCD-CT: A Novel Image-Based Evaluation

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...

Phase One Randomized Two-Arm Dose Escalation of Flash RT in Veterinary Canine Osteosarcoma: Trial Design & Initial Results

Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...

Population Level Robustness Evaluation for Establishment of Benchmarks for Optimized Plans for Prostate Proton Therapy

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey, Taylor Ransom

Affiliation: Thompson Proton Center, University of Tennessee

Abstract Preview: Purpose: Proton pencil beam scanning can reduce normal tissue dose but is highly sensitive to setup, anatomical changes, and range variations. These uncertainties may compromise target coverage and or...

Preplanning Physics Consultation with Voxelized EQD2: A Proactive Approach for Streamlined Dose Management in High-Risk Re-Irradiation Patients

Authors: Katja M. Langen, Mark McDonald, Bill Stokes, Yinan Wang, Suk Whan (Paul) Yoon

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Effective dose management in high-risk re-irradiation (ReRT) patients entails early, detailed special physics consultation (SPC) to mitigate risks from cumulative radiation dose. SPCs have tr...

Python-Based Patient Coaching System for Gated Treatment Delivery

Authors: Usha Robins Abraham, Monique Lockhart Chisem, Alonso N. Gutierrez, Janos Juhasz, Michael Leyva, Carlos M. Rivera, Ranjini P. Tolakanahalli, Vanessa Vega Fleites

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health

Abstract Preview: Purpose:
Accurate breath hold (BH) gated treatments rely heavily on patient cooperation. Maintaining consistent breath-hold levels can be challenging for patients. Surface image guidance (SGRT) is ...

Quantitative Accuracy in Iodine Measurements and CT Numbers Using Standard and Ultra-High Resolution Photon-Counting CT in Coronary CTA

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: To evaluate iodine quantification and CT number accuracy in coronary CT angiography (CTA) using standard and ultra-high resolution (UHR) modes of photon-counting CT (PCCT) across different do...

Radiochemical Monte Carlo Model to Investigate the Oxygen Impacts on Radical Yields Under Proton Flash Irradiation

Authors: Yao Hao, Yuting Peng, Francisco Javier Reynoso, Tianyu Zhao, Xiandong Zhao

Affiliation: Varian, University of South Florida, Washington University School of Medicine, Washington University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Ultra-high dose-rate (FLASH) dose rate (> 40 Gy/s) may result in a radio-protective effect in healthy tissue compared with conventional dose rate (CDR). This effect has been observed in vivo ...

Real-Time Observation of Radiation-Induced DNA Damage for Radiopharmaceuticals

Authors: Denis Bergeron, Brittany Broder, Sean Jollota, Ahtesham Ullah Khan, Michael Lamontagne, Joseph W. Robertson

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Biophysics and Biomedical Research Group, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, National Institute of Standards and Technology

Abstract Preview: Purpose: We present new methodology for real-time measurement of radiation-induced DNA damage caused by radiopharmaceuticals. Building on previous efforts to measure DNA fragmentation with nanopore se...

Real-Time Output Gating and Fault Handling for an Uhdr Mobetron

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...

Routine Quality Monitoring in Abdominal CT Using Global Noise Reference Levels in a 4-Parameter Protocol Summary Plot

Authors: Joke Binst, Hilde TC Bosmans, Niki Fitousi, Bram Miseur, Dimitar Petrov, Kwinten Torfs, Janne Vignero

Affiliation: Qaelum NV, Department of radiology, UZLeuven, Department of imaging and pathology, KULeuven

Abstract Preview: Purpose: Routine quality monitoring in CT abdomen is crucial for ensuring optimal image quality and patient safety, but the simultaneous evaluation of all aspects of importance is challenging. The pur...

The GYN Webapp: A Centralized Tool for Enhancing HDR Brachytherapy Treatment Quality and Clinical Outcomes

Authors: Kevin Albuquerque, Ti Bai, Yesenia Gonzalez, Brian A. Hrycushko, Zohaib Iqbal, Paul M. Medin, Shanshan Tang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cervical cancer remains one of the most common and significant gynecological (GYN) malignancies globally, often presenting at advanced stages where radiation therapy and high-dose-rate (HDR) ...

Time and Energy-Encoded CT Reconstruction

Authors: Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: Conventional computed tomography (CT) measures the collective attenuation of primary photon fluence and then reconstructs the 3D images without using the timing information of individual phot...

To Assess and Monitor the Characteristics of Scanning Proton Beam Utilizing the Xrv-124 Scintillator Device

Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag

Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University

Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...

Towards Achieving Quantitative Attenuation Values in CT with Energy-Integrated and Photon-Counting Detectors

Authors: Zijia Guo, Viktor Haase, Michael F. McNitt-Gray, Frederic Noo

Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: The attenuation values in CT hold strong potential for disease diagnosis. However, they lack reliability, which has limited their use to clinical trials where variability can be controlled. S...

Two Radiochemical Monte Carlo Models to Investigate the Radical Yields Under Proton Flash Irradiations

Authors: Yujie Chi, Yao Hao, Xun Jia, Youfang Lai, Yuting Peng, Francisco Javier Reynoso, Lingshu Yin, Tianyu Zhao, Xiandong Zhao

Affiliation: Johns Hopkins University, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Physics, University of Texas at Arlington, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, University of South Florida

Abstract Preview: Purpose: FLASH radiation therapy has shown remarkable tissue sparing effects compared to radiation therapy at conventional dose rates (CDR). Yet, its mechanism remains unclear. Radical production modu...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...

Validation of a Simulation Tool and in-Silico Assessment of Low Contrast Detectability for Super-Resolution Deep Learning Reconstruction

Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin

Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA

Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...

When Protons Are Unavailable: Study of High Quality Knowledge-Based Planning Models for the Treatment of Unilateral Head and Neck Patients

Authors: Kenny Guida, Daniel Johnson, Wesley Tucker

Affiliation: University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) has emerged as a standard of care for unilateral head and neck (HN) cancers due to superior OAR sparing. With the increase of proton centers national...