Authors: Nebi Demez, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: Treatment plans on the ViewRay MRIdian are often planned with the target placed off isocenter due to the proximity of the bore to the patient, allowing for limited shifts. This is especially ...
Authors: Xiaoxue Qian, Hua-Chieh Shao, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) reduces imaging time and dose but suffers from under-sampling artifacts. 2Dβ3D deformable registration addresses this problem by estimating LA-CBCTs from defor...
Authors: Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu, Jie Zhang
Affiliation: University of Maryland School of Medicine, University of California, Irvine
Abstract Preview: Purpose: To achieve the full-view image from a single-view sinogram using a two-stage deep learning model for electroacoustic-tomography (EAT), which is an emerging imaging technique with significant ...
Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos
Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen
Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...
Authors: Jorge Naoki Dominguez Kondo, Qihui Lyu
Affiliation: University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Targeted alpha therapy (TAT) has emerged as a highly potent therapeutic method in oncology, but its development is limited by the lack of imaging methods to quantify its dosimetry. Convent...
Authors: Sam Beddar, Jason Michael Holmes, Daniel G. Robertson, James J. Sohn, Ethan D. Stolen
Affiliation: Department of Radiation Oncology, Mayo Clinic, MD Anderson Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago
Abstract Preview: Purpose: Camera-based scintillation dosimetry incorporating large volumes have shown promise for fast and comprehensive evaluation of external beam treatment fields. While some efforts have been made ...
Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma
Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC
Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...
Authors: Penghao Gao, Zejun Jiang, Huazhong Shu, Linlin Wang, Gongsen Zhang, Jian Zhu
Affiliation: Laboratory of Image Science and Technology, Key Laboratory of Computer Network and Information Integration, Southeast University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
Abstract Preview: Purpose: We propose a cascading framework for time-varying anatomical volumetric reconstruction and tumor-tracking, guided by onboard orthogonal-view X-ray projections.
Methods: We employe multiple...
Authors: Jadon Buller, Zhuoran Jiang, Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu
Affiliation: University of Maryland School of Medicine, University of California, Irvine, University of California, Stanford University
Abstract Preview: Purpose: Electroacoustic tomography (EAT) and Protoacoustic (PA) imaging are novel modalities for treatment verification of electroporation and proton therapy. However, the limited acquisition angle i...
Authors: Yu Gao, Lei Xing, Siqi Ye
Affiliation: Department of Radiation Oncology, Stanford University
Abstract Preview: Purpose:
Limited-angle CBCT (LA-CBCT) scans are often the only option for non-coplanar radiation therapy to prevent potential mechanical collisions. However, the consecutive angular occlusion of pr...
Authors: Renee Farrell, Jinkoo Kim, Xin Qian, Ziyu Shu, Zhaozheng Yin, Tiezhi Zhang
Affiliation: Stony Brook Medicine, Washington University in St. Louis, Stony Brook University, Stony Brook University Hospital
Abstract Preview: Purpose: Ultra-short CT scan allows fast imaging speed, dose reduction, and compact system design. We developed a deep image prior (DIP) based reconstruction method named Hybrid Prior-Enhanced Deep Im...
Authors: Peter Jermain, Ying Niu, Abdul Rashid, Yuan Yuan, Mohammad Zarenia
Affiliation: Medstar Georgetown University Hospital, MedStar Georgetown University Hospital, Department of Radiation Medicine, MedStar Georgetown University Hospital
Abstract Preview: Purpose: ZAP-X is a self-shielded radiosurgery system that utilizes a linac-based isocentric technique and a compact gyroscopic gantry design. While it provides a large solid angle for beam orientatio...
Authors: Michael B. Altman, Marlene Campos Guerrero, Stephanie Markovina, Aaron Silvus
Affiliation: Washington University School of Medicine
Abstract Preview: Purpose: Currently, fluid injections or needle biopsies in small animals are conducted with limited optical guidance introducing an inherent risk of infecting or injuring the animal and limits precisi...
Authors: Chih-Wei Chang, Junbo Peng, Richard L.J. Qiu, Justin Roper, Xiangyang Tang, Tonghe Wang, Huiqiao Xie, Xiaofeng Yang, David Yu
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Emory Univ, Emory University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered a promising solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, ...
Authors: Jadon O Buller, Yankun Lang, Liangzhong Xiang, Andrea Paulina Yanez
Affiliation: University of Maryland School of Medicine, University of California, Irvine
Abstract Preview: Purpose: With the widespread adoption of electroporation, there is growing interest in deep-tissue electric field monitoring. Electroporation therapy ablates target regions by generating electric fiel...
Authors: Geoffrey D. Hugo, Eric Laugeman, Thomas R. Mazur, Pamela Samson, Kim A. Selting, Zhehao Zhang
Affiliation: University of Illinois, Washington University in St. Louis School of Medicine, WashU Medicine
Abstract Preview: Purpose: To investigate the robustness of a deep learning (DL)-based 4D-CBCT motion-compensated (MoCo) reconstruction method to out-of-distribution data.
Methods: Our developed 4D-CBCT reconstructi...
Authors: Yijian Cao, Sean T Grace, Marissa Joyce Vaccarelli
Affiliation: Northwell
Abstract Preview: Purpose:
This study investigates the dosimetric efficacy of significantly limiting gantry angles in prostate radiation therapy to as a promising strategy to maintain plan quality while enhancing ma...
Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang
Affiliation: The University of Chicago
Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...
Authors: Daniel Ball, Alex Dresner, Geoffrey S. Ibbott, Leonard H. Kim, Christopher Tyerech, SebastiΓ‘n Vega
Affiliation: MD Anderson Cancer Center at Cooper, Cooper Medical School of Rowan University, The American Board of Radiology, Department of Radiation Oncology, University of Pennsylvania, Rowan University, Philips Healthcare MR Oncology
Abstract Preview: Purpose:
In vivo dosimetry is valuable to radiation therapy for its ability to report the actual dose received by patients but is currently limited to surface and intracavitary measurements, leavin...
Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...