4D Monte Carlo Dose Evaluation for Mobile Targets in a Magnetic Field

Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun

Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...

60RPM Rotational Winston Lutz Test to Characterize Operational MV-Kv Offset on Reflexion X1 System

Authors: Huixiao Chen, Ethan Hartowicz, Lichung Ku, Tim Perez, Ray Yang

Affiliation: Salem Health, RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To characterize MV-kV isocenter offset on a novel ring gantry radiotherapy system where the Linac, PET, kV-CT, and MV imaging subsystems rotate together at native operating speed of 60RPM.

6FFF Beam Output Trend Showing Target Degradation

Authors: Sean L. Berry, Hsiang-Chi Kuo, Seng Boh Gary Lim, Ingrid Valencia Lozano, Laszlo Voros

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
To quantify the impact of target degradation on 6FFF beam output by analyzing the output trends and adjustment frequencies at our clinic on a flattening filter-free (6FFF) and a flattened ...

A Method to Check the Consistency and Reproducibility of VMAT Delivery

Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...

A Preliminary Study of Light-Weighted and Flexible Bismuth Nanoparticle-Based Polymer Matrix for Efficient Radiation Shielding

Authors: Ming Su, Yuenan Nancy Wang

Affiliation: Northeastern University, Hartford Healthcare

Abstract Preview: Purpose: High Z elements such as lead are often used to protect critical structures in clinical radiotherapy. Nanoparticles have different properties than bulk materials. We proposed a polymer matrix ...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

An Assessment of the Potential Impact of the Elekta Unity’s 1.5T Magnetic Field upon the Performance of a Conventional Linac Installed in an Adjacent Vault: A Case Study

Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang

Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health

Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...

Assessment of the Quantum-CMOS Image Sensor for Use in Cherenkov Imaging during Radiation Therapy

Authors: Petr Bruza, Jeremy Eric Hallett, Brian W Pogue

Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Cherenkov imaging is a powerful tool for localizing entrance and exit dose during radiotherapy treatment. The current implementation uses an intensified-CMOS (iCMOS) camera allowing for high-...

Automated Treatment Planning for Linac-Based Stereotactic Radiosurgery of Intraocular Malignancies Via Hyperarc Knowledge-Based Planning

Authors: Chase Cochran, Shane McCarthy, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Manually generating intraocular stereotactic radiosurgery (SRS) plans involves significant challenges, including lengthy planning times and inter-planner variability. Knowledge-based SRS plan...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Commissioning, Validation and Pilot Study of New Rpld System for Dosimetry Audits in Bulgaria

Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov

Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital

Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Deep Learning-Based Segmentation Using Cine Epid Images for Real-Time Tumor Monitoring

Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita

Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital

Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...

Determine the Isocenter and Its Size for MR Linac Unity Part1: (U V) of Cax

Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...

Developing Metrics for Evaluating Machine Matching across Elekta Linear Accelerators in a Multicenter Clinic

Authors: Ashley Elizabeth Bonner, Michael G. Snyder

Affiliation: Corewell Health William Beaumont University Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: Develop and evaluate metrics for assessing beam matching of profiles across Elekta linacs in a multisite clinical setting.
Methods: Four Elekta linear accelerators (three VersaHD and one A...

Development and Clinical Validation of Hyperarc Stereotactic Radiosurgery Method for Intraocular Tumors

Authors: Chase Cochran, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Currently, intraocular disease is primarily treated via COMS-plaques brachytherapy. Various stereotactic approaches via photons/proton beam have also been implemented (CyberKnife/GammaKnife/p...

Development of a Beam Profile Variation Observation Model for Intensity Modulated Radiotherapy

Authors: Kaile Li

Affiliation: Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...

Developments of a Low-Cost Multi-Target Winston-Lutz Phantom and Software for SRS Linac Machines

Authors: Nellie Brovold, Wenbo Gu, Huan Amanda Liu, Lin Ma

Affiliation: University of Pennsylvania, Mayo Clinic

Abstract Preview: Purpose: To develop a low-cost comprehensive QA phantom and software for single-iso multi-target SRS Linac machines. This phantom can perform 1) Winston-Lutz QA test for on-axis and off-axis targets, ...

Diffusion-Based PET Image Enhancement in Bgrt

Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie

Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The RefleXionÂź X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...

Dosimetric Accuracy Evaluation of Brainlab Elements 4.0 Treatment Planning System

Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...

Dosimetric Assessment of Simultaneous Multi-Energy and Fluence Optimization for IMRT and VMAT

Authors: Aliasghar Rohani, Rui Zhang

Affiliation: Louisiana State University, Baton Rouge, Louisiana, Department of Radiation Oncology, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the impact of simultaneous optimization of multi-photon beam energy and fluence on IMRT and VMAT treatment planning.
Methods: An Elekta linear accelerator (lin...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko SalomĂłn Alva SĂĄnchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: ClĂ­nica Iram, Clinica Alemana, Hospital ClĂ­nico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Evaluating Target Isocenter Accuracy in Off-Isocenter Treatments Using an Extended Winston-Lutz Test

Authors: Maria de la Luz De Ornelas, Yunze Yang

Affiliation: University of Miami

Abstract Preview: Purpose:
An extended Winston-Lutz test (EWL), also known as off-axis Winston-Lutz, was performed to assess the linear accelerator’s (linac) deviations at isocenter and five off-iso targets. The imp...

Evaluating the Aktina Isopoint System for Quality Assurance in Linear Accelerators

Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...

Evaluation of a Novel Multimodal Deformable Image Registration Algorithm for Pelvic MRI-CT Fusion in Radiotherapy

Authors: Christian Fiandra, Marco Fusella, Gianfranco Loi, Silvia Pesente, Lorenzo Placidi, Claudio Vecchi, Orlando Zaccaria, Stefania Zara

Affiliation: Abano Terme Hospital, University of Turin, Maggiore della CaritĂ , Tecnologie Avanzate Srl, Fondazione Policlinico Universitario Agostino Gemelli IRCCS

Abstract Preview: Purpose: Deformable-image-registration (DIR) is essential in modern radiotherapy for adaptive RT, re-irradiation, and other clinical applications. Multimodal DIR is especially important in MRI-only wo...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Feasibility and Consistency of a Quad Wedge with a 2D Detector Array for Routine Quality Assurance on a MR-Linac

Authors: Grace Hutchinson, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin

Affiliation: Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To assess the feasibility and consistency of the Sun Nuclear Corporation (SNC) MR conditional Quad Wedge, as an accessory to the IC Profiler-MR, and to evaluate beam output and energy in the ...

Feasibility of Producing GRID Therapy Dosimetry Using a Compact Linac Treatment Head with Pencil Beam Scanning

Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin

Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...

Feasibility of Zap-X Beam Quality Assurance Using Cherenkov Radiation

Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao

Affiliation: University of Miami

Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...

Free Radical Irradiation Emergent (FIRE) MRI: Real-Time MR-Based Quantification of Radiation-Produced Free Radical Generation on a Clinical MR-Linac

Authors: Claire Keun Sun Park, Atchar Sudhyadhom, Veena Venkatachalam, Noah Warner

Affiliation: Harvard–MIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: Modern radiotherapy achieves sub-millimeter spatial accuracy but fails to account for patient- and spatially-specific variations in biological response. Free radical generation (FRG), particu...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

Impact of Photon Beam Energy and Symmetry on the Radial Profile Correction Factor for FFF Beams

Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison

Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...

Implementation of a Virtual Quality Assurance System Using Raystation for Online MR-Linac Adaptive Radiotherapy

Authors: Min-Sig Hwang, Danny K. Lee, Daniel C. Pavord, Kyung Lim Yun

Affiliation: Allegheny Health Network

Abstract Preview: Purpose: Ensuring the quality of treatment plans through patient-specific pre-treatment quality assurance (QA) is essential. However, the use of physical phantom-based QA devices is not feasible for o...

Multi-Vendor Linac Isocenter Evaluation: Implications for SRS in Radiotherapy

Authors: Blessing Chinelo Akah, Brad Barhorst, Daniel W. Neck, David J. Perrin, Chad Robertson, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To evaluate the performance and radiation isocenter of Elekta and Varian linear accelerator using Aktina Isopoint.
Methods: The Aktina Isopoint was used to measure the physical and radiati...

Multiparametric and Low-Field MRI for Biomimetic MRI-Readable Gel Dosimeters

Authors: Kaitlyn M Betz, David Dunkerley, Eric Johnson, Kalina V Jordanova, Kathryn E. Keenan, Samuel D Oberdick, Gregory P. Penoncello, Stephen E Russek

Affiliation: Dept of Radiology, Stanford, University of Colorado School of Medicine, NIST, College of Wooster

Abstract Preview: Purpose: Examine use of low-field MRI and multiparametric analysis for 3D MRI-readable biomimetic gel dosimetry. Low-field MRIs are compact, inexpensive, and portable. They could be located within rad...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Patient-Specific Quality Assurance in SBRT Treatments Using 3D Polymer Gel Dosimetry

Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-ChacĂłn, Alejandro Rodriguez-Laguna

Affiliation: UNAM, Medica Sur

Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...

Radiation Shielding Considerations for Ultra-High Dose Rate Electron Flash Radiation Therapy

Authors: Alexandru Badalan, Peter Petric, I. Antoniu Popescu, Andrew Kyle Henderson Robertson

Affiliation: Bc Cancer, BC Cancer - Vancouver, BC Cancer

Abstract Preview: Purpose: Ultra-high dose rate (>40 Gy/s) or “FLASH” radiation therapy (RT) has the potential to improve cancer treatment through reduced radiation side effects. While electron FLASH beams can be produ...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

The Development of Large Field MR Guided Radiotherapy for Pelvic Lymph Node SBRT and Its Dosimetry Improvement

Authors: David Byun, Ting Chen, Paulina E. Galavis, Allison McCarthy, Hesheng Wang, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose: To summarize a MR guided adaptive workflow developed for pelvic lymph nodes (PLN) stereotactic radiotherapy using large field size on Elekta Unity© MR Linac system, and to quantitatively anal...

Treatment Plan Comparisons of Head and Neck Cancers on Varian Ethos/Halcyon and Truebeam Linac

Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...

Tumor Dose Escalation for Recurrent Head and Neck SRT Via a Hyperarc-Based Rapidplan Model

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstrating the feasibility of dose escalation for stereotactic recurrent head and neck (RHN) cancers through the deployment of a Hyper-Arc Based RapidPlan (HARP) model through an Eclipse S...

Two-Element Complementary Sensor for out-of-Plane Tracking in MR-Guided Radiotherapy

Authors: Zhaohui Han, Piotr Zygmanski

Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School

Abstract Preview: Purpose: Real-time motion tracking/gating are oftentimes limited to a single sagittal plane on many magnetic resonance linear accelerators (MR-Linac). Out-of-plane motion is therefore difficult to det...

Validation of a Novel Dielectric Layer-Based Detector for Linear Accelerator Quality Assurance

Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)

Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...