Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun
Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute
Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...
Authors: Huixiao Chen, Ethan Hartowicz, Lichung Ku, Tim Perez, Ray Yang
Affiliation: Salem Health, RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: To characterize MV-kV isocenter offset on a novel ring gantry radiotherapy system where the Linac, PET, kV-CT, and MV imaging subsystems rotate together at native operating speed of 60RPM.
Authors: Sean L. Berry, Hsiang-Chi Kuo, Seng Boh Gary Lim, Ingrid Valencia Lozano, Laszlo Voros
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
To quantify the impact of target degradation on 6FFF beam output by analyzing the output trends and adjustment frequencies at our clinic on a flattening filter-free (6FFF) and a flattened ...
Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens
Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre
Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...
Authors: Ming Su, Yuenan Nancy Wang
Affiliation: Northeastern University, Hartford Healthcare
Abstract Preview: Purpose: High Z elements such as lead are often used to protect critical structures in clinical radiotherapy. Nanoparticles have different properties than bulk materials. We proposed a polymer matrix ...
Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health
Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...
Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health
Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unityâs 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...
Authors: Petr Bruza, Jeremy Eric Hallett, Brian W Pogue
Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: Cherenkov imaging is a powerful tool for localizing entrance and exit dose during radiotherapy treatment. The current implementation uses an intensified-CMOS (iCMOS) camera allowing for high-...
Authors: Chase Cochran, Shane McCarthy, Damodar Pokhrel, William St Clair
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: Manually generating intraocular stereotactic radiosurgery (SRS) plans involves significant challenges, including lengthy planning times and inter-planner variability. Knowledge-based SRS plan...
Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...
Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov
Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital
Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...
Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago
Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...
Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita
Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital
Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...
Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...
Authors: Ashley Elizabeth Bonner, Michael G. Snyder
Affiliation: Corewell Health William Beaumont University Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose: Develop and evaluate metrics for assessing beam matching of profiles across Elekta linacs in a multisite clinical setting.
Methods: Four Elekta linear accelerators (three VersaHD and one A...
Authors: Chase Cochran, Damodar Pokhrel, William St Clair
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: Currently, intraocular disease is primarily treated via COMS-plaques brachytherapy. Various stereotactic approaches via photons/proton beam have also been implemented (CyberKnife/GammaKnife/p...
Authors: Kaile Li
Affiliation: Alexander T. Augusta Miliary Medical Center
Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...
Authors: Nellie Brovold, Wenbo Gu, Huan Amanda Liu, Lin Ma
Affiliation: University of Pennsylvania, Mayo Clinic
Abstract Preview: Purpose: To develop a low-cost comprehensive QA phantom and software for single-iso multi-target SRS Linac machines. This phantom can perform 1) Winston-Lutz QA test for on-axis and off-axis targets, ...
Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie
Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose:
The RefleXionÂź X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...
Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz
Affiliation: UT Health San Antonio, University of Texas HSC San Antonio
Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...
Authors: Aliasghar Rohani, Rui Zhang
Affiliation: Louisiana State University, Baton Rouge, Louisiana, Department of Radiation Oncology, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: This study aimed to evaluate the impact of simultaneous optimization of multi-photon beam energy and fluence on IMRT and VMAT treatment planning.
Methods: An Elekta linear accelerator (lin...
Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko SalomĂłn Alva SĂĄnchez
Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal
Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...
Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada
Affiliation: ClĂnica Iram, Clinica Alemana, Hospital ClĂnico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health
Abstract Preview: Purpose: To investigate and compare the new method âPulse Normalizationâ proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...
Authors: Maria de la Luz De Ornelas, Yunze Yang
Affiliation: University of Miami
Abstract Preview: Purpose:
An extended Winston-Lutz test (EWL), also known as off-axis Winston-Lutz, was performed to assess the linear acceleratorâs (linac) deviations at isocenter and five off-iso targets. The imp...
Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...
Authors: Christian Fiandra, Marco Fusella, Gianfranco Loi, Silvia Pesente, Lorenzo Placidi, Claudio Vecchi, Orlando Zaccaria, Stefania Zara
Affiliation: Abano Terme Hospital, University of Turin, Maggiore della CaritĂ , Tecnologie Avanzate Srl, Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Abstract Preview: Purpose: Deformable-image-registration (DIR) is essential in modern radiotherapy for adaptive RT, re-irradiation, and other clinical applications. Multimodal DIR is especially important in MRI-only wo...
Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx
Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique
Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...
Authors: Grace Hutchinson, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin
Affiliation: Iowa Health Care, University of Iowa
Abstract Preview: Purpose: To assess the feasibility and consistency of the Sun Nuclear Corporation (SNC) MR conditional Quad Wedge, as an accessory to the IC Profiler-MR, and to evaluate beam output and energy in the ...
Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin
Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...
Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao
Affiliation: University of Miami
Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...
Authors: Claire Keun Sun Park, Atchar Sudhyadhom, Veena Venkatachalam, Noah Warner
Affiliation: HarvardâMIT Program in Health Sciences and Technology, Massachusetts Institute of Technology, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: Modern radiotherapy achieves sub-millimeter spatial accuracy but fails to account for patient- and spatially-specific variations in biological response. Free radical generation (FRG), particu...
Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Womenâs Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute
Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...
Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...
Authors: Min-Sig Hwang, Danny K. Lee, Daniel C. Pavord, Kyung Lim Yun
Affiliation: Allegheny Health Network
Abstract Preview: Purpose: Ensuring the quality of treatment plans through patient-specific pre-treatment quality assurance (QA) is essential. However, the use of physical phantom-based QA devices is not feasible for o...
Authors: Blessing Chinelo Akah, Brad Barhorst, Daniel W. Neck, David J. Perrin, Chad Robertson, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: To evaluate the performance and radiation isocenter of Elekta and Varian linear accelerator using Aktina Isopoint.
Methods: The Aktina Isopoint was used to measure the physical and radiati...
Authors: Kaitlyn M Betz, David Dunkerley, Eric Johnson, Kalina V Jordanova, Kathryn E. Keenan, Samuel D Oberdick, Gregory P. Penoncello, Stephen E Russek
Affiliation: Dept of Radiology, Stanford, University of Colorado School of Medicine, NIST, College of Wooster
Abstract Preview: Purpose: Examine use of low-field MRI and multiparametric analysis for 3D MRI-readable biomimetic gel dosimetry. Low-field MRIs are compact, inexpensive, and portable. They could be located within rad...
Authors: Larry A. DeWerd, Ahtesham Ullah Khan
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison
Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...
Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-ChacĂłn, Alejandro Rodriguez-Laguna
Affiliation: UNAM, Medica Sur
Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...
Authors: Alexandru Badalan, Peter Petric, I. Antoniu Popescu, Andrew Kyle Henderson Robertson
Affiliation: Bc Cancer, BC Cancer - Vancouver, BC Cancer
Abstract Preview: Purpose: Ultra-high dose rate (>40 Gy/s) or âFLASHâ radiation therapy (RT) has the potential to improve cancer treatment through reduced radiation side effects. While electron FLASH beams can be produ...
Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...
Authors: David Byun, Ting Chen, Paulina E. Galavis, Allison McCarthy, Hesheng Wang, Michael J Zelefsky
Affiliation: NYU Langone Health
Abstract Preview: Purpose: To summarize a MR guided adaptive workflow developed for pelvic lymph nodes (PLN) stereotactic radiotherapy using large field size on Elekta Unity© MR Linac system, and to quantitatively anal...
Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...
Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang
Affiliation: University of Kentucky, Department of Radiation Medicine
Abstract Preview: Purpose: Demonstrating the feasibility of dose escalation for stereotactic recurrent head and neck (RHN) cancers through the deployment of a Hyper-Arc Based RapidPlan (HARP) model through an Eclipse S...
Authors: Zhaohui Han, Piotr Zygmanski
Affiliation: Brigham and Womenâs Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Radiation Oncology, Brigham and Womenâs Hospital, Dana-Farber Cancer Institute, Harvard Medical School
Abstract Preview: Purpose: Real-time motion tracking/gating are oftentimes limited to a single sagittal plane on many magnetic resonance linear accelerators (MR-Linac). Out-of-plane motion is therefore difficult to det...
Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)
Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...