12 Year Clinical Experience with Low-Tesla MRI for Tumor Progression

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Low-Tesla MRI (0.23T Panorama MR Scanner, Philips) has been used for tumor progression during proton therapy treatments, and for initial contouring in addition to diagnostic MRI. The pulse...

Design and Testing of an External Control System for Beam Control and Pre-Delivery Optimization for Conventional- and Ultra-High-Dose-per-Pulse Flash Irradiations

Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler

Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...

Development of an Ultrafast MR Technique to Detect Linac Radiation Pulses for Biological Imaging on a Clinical 0.35T MR-Linac

Authors: Pierre Gardair, Johnathan E Leeman, Claire Keun Sun Park, Atchar Sudhyadhom

Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School, Harvard Medical School

Abstract Preview: Purpose: Dose is a poor surrogate for radiobiological damage but no in vivo technology exists to directly measure damage such as DNA strand breaks and free radical generation (FRG). Recent advances in...

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...

Establishing a Conventional Linac-Based Electron Flash Beam

Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma

Affiliation: Blue Physics LLC, Virginia Commonwealth University

Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: Clínica Iram, Clinica Alemana, Hospital Clínico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

First Beam Characterization of the Radiabeam FLEX-9 Electron Flash Linac

Authors: Robert Berry, John Buatti, Nathan Burger, Ryan T. Flynn, Greg Johns, Maksim Kravchenko, Sergey Kutsaev, Yen-Po Lee, Marcos Ruelas, Joel J. St-Aubin, Timothy J. Waldron

Affiliation: RadiaBeam Technologies, University of Iowa

Abstract Preview: Purpose: To report the factory acceptance tests of a preclinical linear accelerator, the FLEX-9 electron FLASH linac from RadiaBeam Technologies.
Methods: The FLEX-9 FLASH electron linac is designe...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

Monitor Unit (MU) Substructure Analysis for Low MU Deliveries

Authors: Indra J. Das, Ahtesham U. Khan, Andrew J. White, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: During intensity modulated radiotherapy (IMRT) planning, low MU segments (< 3 MU) are commonly avoided due to documented dosimetric nonlinearity and poor reproducibility. This work aims to ex...

Reduction of the Charge Build-up Effect on the Beam Current Transformers for Real-Time Monitoring of Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Beam current transformers (BCTs) are a promising alternative to ion chambers for real-time monitoring of ultra-high dose per-pulse (UHDPP) beams. The signal of the BCT is insensitive to ion r...

Slit Scanning Delivery Simulation for Flash Radiotherapy

Authors: Muhammad Ramish Ashraf, Dixin Chen, Aaron Garza, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner, Murat Surucu

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: FLASH radiotherapy, supported by robust preclinical evidence showing an improved therapeutic index, is advancing toward clinical trials. Clinical FLASH treatments will likely require scanning...

The Feasibility of Ethos-Based Pulsed Reduced Dose-Rate (PRDR) Radiotherapy

Authors: Chia-Lung Chien, Renteng Hou, Wen C. Hsi, Faraz Kalantari, Ganesh Narayanasamy, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
PRDR is an effective re-irradiation treatment for patients who have already reached the tolerance dose to their organs at risk (OARs). While PRDR is implemented on TrueBeam by limiting the...

Towards Clinical Translation: Optical Methods Deliver in-Vivo per-Pulse Dosimetry in Electron Flash-RT

Authors: Petr Bruza, Rafael Carballeira, Megan Clark, David J. Gladstone, Austin Sloop, Roman Vasyltsiv, Kevin Jacob Willy

Affiliation: Dartmouth College, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Develop an optical dosimetry system to accomplish standard of care on-patient dosimetry and pretreatment quality assurance for ultra-high dose rate (UHDR) electron therapy ahead of human tria...

Treatment Dose Reconstruction of Digitized Deliveries on Reflexion X1 System Based on Megavoltage Imager and Dose Monitor Chamber

Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang

Affiliation: RefleXion Medical

Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...