Search Submissions ๐Ÿ”Ž

Results for "linac unity": 39 found

A No-Reference Medical Image Quality Assessment Method Based on Automated Distortion Recognition Technology: Application to Preprocessing in MRI-Guided Radiotherapy

Authors: Jiayun Chen, Shengqi Chen, Yuan Tang, Zilin Wang, Guohua Wu, Jianan Wu

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, School of Electronic Engineering, Beijing University of Posts and Telecommunications, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose:
To develop a novel no-reference image quality assessment (NRIQA) method for evaluating the effectiveness of image preprocessing in MRI-guided radiotherapy (MRIgRT), thereby enhancing clini...

An Assessment of the Potential Impact of the Elekta Unityโ€™s 1.5T Magnetic Field upon the Performance of a Conventional Linac Installed in an Adjacent Vault: A Case Study

Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang

Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health

Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unityโ€™s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Application of a Conditional Diffusion Model to Improve Real-Time MR Imaging in Online Adaptive MR-Guided Radiotherapy

Authors: Hideaki Hirashima, Haruo Inokuchi, Nobutaka Mukumoto, Naruki Murahashi, Mitsuhiro Nakamura, Megumi Nakao, Keiko Shibuya, Linna Zhang

Affiliation: Kyoto University, Osaka Metropolitan University

Abstract Preview: Purpose:
To transform the quality of 2D cine MR images acquired during online adaptive MR-guided radiotherapy (OA-MRgRT) by utilizing a conditional diffusion model to achieve image quality comparab...

Assessment of Deep Learning Models for 3D Dose Prediction in Prostate Cancer SIB-IMRT Using MR-Linac

Authors: Hao-Wen Cheng, Jonathan G. Li, Chihray Liu, Wen-Chih Tseng, Guanghua Yan

Affiliation: University of Florida

Abstract Preview: Purpose: This study develops and evaluates deep learning (DL) models for predicting 3D dose distributions in simultaneous integrated boost (SIB) prostate cancer treatment using the Elekta Unity MR-Lin...

Assessment of the Auto Registration Feature of the PET/CT Linac Used for Biology Guided Radiation Therapy (BGRT)

Authors: Emily Hansen, Tyler Kaulfers, Alois M. Ndlovu, Francia Romero, Niara Rowe, Roland Teboh

Affiliation: Montefiore Einstein University Hospital, Hackensack University Medical Center

Abstract Preview: Purpose: Daily use and reliance on the auto registration feature requires a performance check. Clinical application of auto registration is performed without a selected region of interest (ROI), requi...

Can AI Agent be a Good Judge for Online Adaptive Radiotherapy Plan Evaluation?

Authors: Steve B. Jiang, Mu-Han Lin, Dan Nguyen, Beiqian Qi, Daniel Yang, Ying Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Online adaptive radiotherapy (oART) is a resource-intensive workflow requiring significant time and effort required from clinicians, particularly for the online evaluation of plan quality....

Clinical Implementation of a Film Based Psqa System for SBRT on a 1.5T MR-Linac

Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal

Affiliation: Sunnybrook Health Sciences Centre

Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...

Determine the Isocenter and Its Size for MR Linac Unity Part1: (U V) of Cax

Authors: Ting Chen, Siming Lu, Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This study, the first in a two-part series, aims to determine the isocenter position and size for the MR Linac UNITY, focusing on the central axis (CAX) alignment of its Multi-Leaf Collimator...

Determine the Isocenter and Its Size for MR Linac Unity Part2: (u v) of BB and Isocenter Position and Size

Authors: Tanxia Qu, Hesheng Wang

Affiliation: NYU Langone Health

Abstract Preview: Purpose:
This study, the second in a two-part series, evaluates the isocenter position (the point in 3D space minimizing the sum of Euclidean distances to the MLC's central axis) and isocenter size...

Developing Metrics for Evaluating Machine Matching across Elekta Linear Accelerators in a Multicenter Clinic

Authors: Ashley Elizabeth Bonner, Michael G. Snyder

Affiliation: Corewell Health William Beaumont University Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: Develop and evaluate metrics for assessing beam matching of profiles across Elekta linacs in a multisite clinical setting.
Methods: Four Elekta linear accelerators (three VersaHD and one A...

Development and Evaluation of Aria Report-Based Initial Chart Check Tool

Authors: Ulrich Langner, Timothy Leech, Oleksii Semeniuk

Affiliation: Brown University Health

Abstract Preview: Purpose: To standardize and improve quality of the chart review process, while simultaneously increasing the efficiency of the physicist, by allowing them to allocate more time for other items.
Met...

Development and Validation of an MR-Compatible Anthropomorphic Motion Phantom for Liver Motion Assessment and MR-Linac Gating System Optimization

Authors: Tsuicheng D. Chiu, Weiguo Lu, Aaron Thomlinson, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: To develop and validate an MR-compatible anthropomorphic motion phantom to assess liver motion, real-time dosimetry, and gating system performance under controlled and reproducible respirator...

Development of a Beam Profile Variation Observation Model for Intensity Modulated Radiotherapy

Authors: Kaile Li

Affiliation: Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...

Direct-to-Unit Dose Calculations for Stereotactic Radiosurgery on a C-Arm Linac with Modern on-Board Imaging Solutions

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Evaluating the Aktina Isopoint System for Quality Assurance in Linear Accelerators

Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...

Evaluation of Thoracic Direct Dose Calculation Using Truebeam Linac with Hypersight Imaging CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...

Exploring the Compatibility of VMAT and Respiratory Beam Gating on MR-Linac: A Proof-of-Concept Study

Authors: Caiden Atienza, Pim T. S. Borman, Martin F. Fast, Daniel E. Hyer, Bas W. Raaymakers, Jeffrey E. Snyder, Prescilla Uijtewaal, Peter Woodhead

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Yale New Haven Health, University of Iowa

Abstract Preview: Purpose:
On conventional C-arm linacs, VMAT is the preferred delivery modality due to its superior efficiency and highly conformal dose distributions. MR-linacs offer superior soft-tissue imaging t...

Feasibility and Consistency of a Quad Wedge with a 2D Detector Array for Routine Quality Assurance on a MR-Linac

Authors: Grace Hutchinson, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin

Affiliation: Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To assess the feasibility and consistency of the Sun Nuclear Corporation (SNC) MR conditional Quad Wedge, as an accessory to the IC Profiler-MR, and to evaluate beam output and energy in the ...

Feasibility of Efficient Offline Adaptive Replanning with Hypersight High-Performance Cone-Beam CT on Truebeam for Pelvis RT

Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang

Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...

Financial Viability Analysis of on-Table Simulation Enabled Halcyon Using Time Driven Activity-Based Costing

Authors: Xinyuan Chen, Geoffrey D. Hugo, Alex T. Price, Pamela Samson, Tianyu Zhao

Affiliation: University Hospitals Seidman Cancer Center, University of South Florida, Washington University School of Medicine, WashU Medicine

Abstract Preview: Purpose: This study evaluates the financial viability of on-table simulation (CBCTp) enabled Halcyon system in radiation therapy. By leveraging Time-Driven Activity-Based Costing (TDABC), the analysis...

Impact of Patient Setup Errors on the MR Linac-Based SBRT Treatment for Prostate Cancer

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: In radiation therapy, patient setup errors have been a primary concern impacting dose delivery accuracy. A robust treatment plan is essential to mitigate these errors. This study aimed to eva...

In-Vivo Image Quality of Head/Neck and CNS with an Advanced C-Arm Linac CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Christian Erik Petersen, Alex T. Price, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: CBCT is subject to more artifacts due to increased photon scatter, especially in areas of increased tissue heterogeneities compared to fan-beam CTs (FBCTs). Improved imaging panels combined w...

Inter-System and Inter-Layer Dlg Variations in Halcyon/Ethos Mlcs: Implications for Dosimetric Matching and User-Adjustable TPS Models

Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC

Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...

Investigating the Dosimetric Benefits of Enhanced Solid Angle Accessibility in a Self-Shielded Radiosurgery System

Authors: Peter Jermain, Ying Niu, Abdul Rashid, Yuan Yuan, Mohammad Zarenia

Affiliation: Medstar Georgetown University Hospital, MedStar Georgetown University Hospital, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose: ZAP-X is a self-shielded radiosurgery system that utilizes a linac-based isocentric technique and a compact gyroscopic gantry design. While it provides a large solid angle for beam orientatio...

Investigating the Use of a DWI Phantom for Routine QA of an MR-Linac at Room Temperature

Authors: Nicholas Carlson, Joel J. St-Aubin

Affiliation: University of Iowa Hospitals and Clinics, University of Iowa

Abstract Preview: Purpose: To establish baselines metrics and determine longitudinal accuracy and reproducibility of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) values for a 1.5T Elekta Un...

Liver Tumor Auto-Contouring Using Recurrent Neural Networks on MRI-Linac for Adaptive Radiation Therapy

Authors: Yan Dai, Jie Deng, Christopher Kabat, Weiguo Lu, Ying Zhang, Hengrui Zhao

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
MRI-guided adaptive radiotherapy (MRgART) using MR-LINAC systems offers significant advantages for liver cancer, enabling superior tumor delineation and online plan adaptation. However, ma...

Monitor Unit (MU) Substructure Analysis for Low MU Deliveries

Authors: Indra J. Das, Ahtesham U. Khan, Andrew J. White, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: During intensity modulated radiotherapy (IMRT) planning, low MU segments (< 3 MU) are commonly avoided due to documented dosimetric nonlinearity and poor reproducibility. This work aims to ex...

Multi-Vendor Validation of a Deep Learning-Based Synthetic CT Generation Model for MR-Only Radiotherapy Planning in the Pelvis

Authors: Gregory Bolard, Rabten Datsang, Sarah Ghandour, Timo Kiljunen, Pauliina Paavilainen, Sami Suilamo, Katlin Tiigi

Affiliation: Turku University Hospital, Virginia Commonwealth University, MVision AI, North Estonia Medical Centre, Docrates Cancer Center, Hopital Riviera-Chablais

Abstract Preview: Purpose: To verify the performance of a vendor-neutral deep learning model for synthetic CT generation from T2-weighted and balanced steady-state MR sequences to support both MR-only simulation and MR...

Multiparametric and Low-Field MRI for Biomimetic MRI-Readable Gel Dosimeters

Authors: Kaitlyn M Betz, David Dunkerley, Eric Johnson, Kalina V Jordanova, Kathryn E. Keenan, Samuel D Oberdick, Gregory P. Penoncello, Stephen E Russek

Affiliation: Dept of Radiology, Stanford, University of Colorado School of Medicine, NIST, College of Wooster

Abstract Preview: Purpose: Examine use of low-field MRI and multiparametric analysis for 3D MRI-readable biomimetic gel dosimetry. Low-field MRIs are compact, inexpensive, and portable. They could be located within rad...

Preliminary Clinical Experience with MRI-Guided Online Adaptive Radiotherapy for Esophageal Cancer Patients

Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu

Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health

Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...

Radiomics Changes in MR Images of Prostate and Dominant Intra-Prostate Lesions during SBRT on MR-Linac

Authors: David L. Barbee, David Byun, Ting Chen, Paulina E. Galavis, Siming Lu, Sarah Rosemary Morris, Hesheng Wang, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose: MR-Linac enables dose escalation in prostate SBRT on accurately defined dominant intra-prostate lesion (DIL) on daily MR images. This study aims to evaluate inter-fraction changes in the radi...

Real-Time 3D Dose Verification for MR-Guided Online Adaptive Radiotherapy (ART) Via Geometry-Encoded Deep Learning Framework

Authors: Steve B. Jiang, Dan Nguyen, Chenyang Shen, Fan-Chi F. Su, Jiacheng Xie, Shunyu Yan, Daniel Yang, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Fast dose verification is essential for the safety and efficiency of MR-guided adaptive radiotherapy (ART) as patients anxiously waiting on the treatment couch. Conventional tools often requi...

Small Fields Output Factor Measurements in 1.5 MR-Linac

Authors: Thomas I. Banks, Tsuicheng D. Chiu, Viktor M. Iakovenko, Christopher Kabat, Chang-Shiun Lin, Mu-Han Lin, Arnold Pompos

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: The superior soft-tissue contrast provided by MR imaging offers favorable conditions for the effective application of stereotactic body radiation therapy (SBRT). Accurate small field dosimetr...

The Development of Large Field MR Guided Radiotherapy for Pelvic Lymph Node SBRT and Its Dosimetry Improvement

Authors: David Byun, Ting Chen, Paulina E. Galavis, Allison McCarthy, Hesheng Wang, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose: To summarize a MR guided adaptive workflow developed for pelvic lymph nodes (PLN) stereotactic radiotherapy using large field size on Elekta Unityยฉ MR Linac system, and to quantitatively anal...

VMAT Machine Parameter Optimization Using Policy Gradient Reinforcement Learning

Authors: Avinash Mudireddy, Nathan Shaffer, Joel J. St-Aubin

Affiliation: University of Iowa

Abstract Preview: Purpose: This work demonstrates preliminary results in training a reinforcement learning (RL) network to perform VMAT machine parameter optimization.
Methods: We implemented a policy gradient RL al...

Validation of a Novel Dielectric Layer-Based Detector for Linear Accelerator Quality Assurance

Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)

Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...

Validation of an Ivim Tool for Liver Hypoxia Assessment for an Online Adaptive MR-Linac System

Authors: Jean-Pierre Bissonnette, Catherine Coolens, Laura Dawson, Ryan A Kuhn, Michael Maddalena, Teo Stanescu

Affiliation: Princess Margaret Hospital, The Princess Margaret Cancer Centre - UHN, University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To investigate the generation and reproducibility of 3D hypoxia maps in liver hepatocellular carcinoma (HCC) patients using data derived from an Intravoxel Incoherent Motion (IVIM) MR sequenc...