Search Submissions 🔎

Results for "linearity rate": 12 found

A 2D Discrete Ionization Chamber Array for Proton Pencil Beam Scanning Flash Dosimetry

Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou

Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica

Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterization of a Novel Large-Sized Epid System from the Newly Released Ring Shape Radiation Therapy Halos Tx

Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang

Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment

Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Design and Testing of an External Control System for Beam Control and Pre-Delivery Optimization for Conventional- and Ultra-High-Dose-per-Pulse Flash Irradiations

Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler

Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...

Dosimeteric Parameter Evaluation of Digital Polycrystalline Semiconductor Dosimeters for Quality Assurance of High-Dose-Rate Brachytherapy

Authors: Woong Cho, Jin-Beom Chung, Moo-Jae Han, Sang Won Kang, Boram Lee

Affiliation: Department of Radiation Oncology, Seoul National University Boramae Medical Center, Department of Radiation Oncology, Seoul National University Bundang Hospital, Department of Radiation Oncology, Inha University Hospital

Abstract Preview: Purpose: This study aims to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy by evaluating self-developed polycrystalline semiconductor dosimeters (PSDs).
Me...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectors™ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko Salomón Alva Sánchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

Optimizing Calibration Radioisotope and Activity for Dose Calibrator Linearity Testing in Radiopharmaceutical Therapy and Theranostic Facilities

Authors: Kimyli Lemieux, Xingyu Nie

Affiliation: University of Kentucky/UK HealthCare

Abstract Preview: Purpose: To optimize the selection of calibration radioisotope and its activity for dose calibrator (DC) linearity testing, adhering to ALARA (As Low As Reasonably Achievable) principles while conside...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...