A Method to Expedite Quality Assurance for Head and Neck Ctvs with Lymph Node Level Auto-Autocontouring and Identification

Authors: Beth M. Beadle, Adrian Celaya, Laurence Edward Court, David Fuentes, Anna Lee, Tze Yee Lim, Dragan Mirkovic, Amy Moreno, Raymond Mumme, Tucker J. Netherton, Callistus M. Nguyen, Jaganathan A Parameshwaran, Jack Phan, Carlos Sjogreen, Sara L. Thrower, Congjun Wang, He C. Wang, Xin Wang

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, Stanford University, The University of Texas MD Anderson Cancer Center, MD Anderson Cancer Center, MD Anderson, Rice University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Quality assurance of target volumes from radiotherapy clinical trials is a labor and resource intensive task. The purpose of this work is to quantify the accuracy of a tool that automatically...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Assessing the Potential of Remote Navigation Systems to Mitigate GI Toxicity in Abdominal SBRT

Authors: Justus Adamson, Wesley Andrew Cunningham, Caleb Logan Smith

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: Radiation induced bowel toxicity is a persistent issue for abdominal Stereotactic Body Radiation Therapy (SBRT). Remote magnetic navigation systems (RMNS) have been developed for use in magne...

Assessment of the Impact of CT Respiratory Motion on PET SUV Quantification through Virtual Imaging

Authors: Ehsan Abadi, Darrin Byrd, Paul E. Kinahan, Katie Marie Olivas, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Washington

Abstract Preview: Purpose: To evaluate the impact of respiratory motion during CT acquisitions on PET image quantification using an integrated PET-CT simulation pipeline.
Methods: A validated CT simulator (DukeSim) ...

Automated Treatment Planning for Stereotactic Recurrent Head and Neck Cancers Using Knowledge-Based Planning, Multicriteria Optimization, and Dosimetric Scorecards

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstration of automated stereotactic treatment planning for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecard...

Clinical Validation of AI-Driven Segmentation Model for Pediatric Craniospinal Irradiation: Marked Reduction in Contouring Time and Enhanced Workflow Efficiency

Authors: Alexander Choi, William Ross Green, Christine Hill-Kayser, Gary D. Kao, Michael LaRiviere, Rafe A. McBeth, Steven Philbrook

Affiliation: Department of Radiation Oncology, University of Pennsylvania

Abstract Preview: Purpose: To validate the potential of clinical deployment of an in-house AI-driven auto-segmentation tool for pediatric craniospinal irradiation (CSI) in proton therapy, with goals of reducing manual ...

Daily Adaptive Treatment Planning with Radixact for Head and Neck Cancer: A Dosimetric Evaluation

Authors: Yong Chen, Christina Henson, Yuchen Qiu, Marti Roper

Affiliation: University of Oklahoma HSC, University of Oklahoma Health Sciences Center, University of Oklahoma, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Traditionally, Head and Neck cancer patients have one or two treatment replans through their treatment course, which fails to account for anatomical changes in position, weight loss, or tumor...

Developing and Evaluating the First Pre-Treatment Physics Plan Checklist for Error Detection in Biology-Guided Radiotherapy (BgRT)

Authors: Michael Burke, David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Vanessa Hill, Ann-Teresa Jasman, John Kim, Svetlana Kuznetsova, MinYoung Lee, Daniel Longo, Henry S. Park, Adam Shulman, Lauren Tressel, Weili Zhong

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The complexity of biology-guided radiotherapy (BgRT), particularly with systems like RefleXion X1, necessitates robust pre-treatment quality assurance (QA) to ensure patient safety, treatm...

EPR Oximetry for Hypoxia Assessment in Deep Tissues Using Oxytrack

Authors: Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert

Affiliation: Dartmouth College

Abstract Preview: Purpose: The rigid needle-like EPR sensor, OxyTrack, was developed to provide minimally invasive, reliable, and quantitative measurements of oxygen distribution (pO2) in deep tissues. EPR oximetry's c...

Enhancing Medical Physics Education: From Student Needs to a Moodle-Based LMS

Authors: Paul B. Ravindran

Affiliation: Christian Institute of Health Sciences and Research

Abstract Preview: Purpose: In the past decades, Master's programs in Medical Physics in India have made significant strides, though many have faced challenges in accessing adequate resources for didactic lectures and p...

Evaluating 177Lu-PSMA-I&t Reconstruction Parameter Influences on Image Quality and Quantification

Authors: Martin Auerbach, Jeremie Calais, Johannes Czernin, Magnus Dahlbom, Zachary Ells, Adrien Holzgreve, Koichiro Kimura, Karam Masri, Catherine (Caffi) Meyer, David Sennung

Affiliation: Department of Nuclear Medicine, UCLA, UCLA, University of California, Los Angeles

Abstract Preview: Purpose: Lutetium-177 PSMA SPECT/CT imaging offers the possibility of qualitative image analysis for tumor response assessment and quantitative image analysis for individualized dosimetry. However, th...

Feasibility of X-Ray Based Online Adaptive Dynamic Optimization with Integrated Knowledge-Based Planning for Head and Neck Cancer

Authors: Jacob S. Buatti, Mu-Han Lin, Dominic Moon, David D.M. Parsons, David Sher, Justin D. Visak, Hui Ju Wang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: Most current adaptive treatment planning systems (TPS) natively utilize static planning goals from the reference plan for online adaptive re-optimization. In complex head-and-neck cancer (HNC...

Impact of Lung Density on Plan Quality and Delivery Parameters in Lung Stereotactic Body Radiation Therapy (SBRT) Plans

Authors: David Chighvinadze, Indra J. Das, Jeremy D. Donaghue, Kevin Stephans, Gregory Videtic, Sugandima Weragoda, Ping Xia

Affiliation: Cleveland Clinic, Cleveland Clinic Sandusky, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Cleveland Clinic Fairview

Abstract Preview: Purpose:: Evaluate the impact of lung density variations on plan quality and delivery parameters in lung SBRT Plans.
Methods: For a hypothetical case with a real patient anatomy, three GTVs with vo...

Initial Three-Year Machine Performance Assessment of a Superficial Radiation Therapy Unit

Authors: Vibha Chaswal, Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, William Romaguera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: To report machine performance of our superficial radiation therapy unit (SRT-100 Vision, Sensus Healthcare, Boca Raton, FL) for the first three years after commissioning of the unit.
Metho...

Intelligent Black Box Recording for Radiation Therapy: Feasibility Study of Vision-Language Models for Treatment Monitoring.

Authors: Wookjin Choi, James M. Lamb, David Romanofski, David H. Thomas, Yevgeniy Vinogradskiy

Affiliation: Drexel, Department of Radiation Oncology, University of California, Los Angeles, Thomas Jefferson University

Abstract Preview: Purpose: To develop an intelligent Black Box Recorder for radiation therapy (RT) that monitors patient treatments using a vision language model.
Methods: The system captures synchronized screen rec...

Investigation of Low Iodine Concentration Detectability of Dual-Energy CT Imaging Using a Customized 3D Printed Phantom

Authors: Michalis Aristophanous, Laura I. Cervino, Maria F. Chan, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Y Lee, Xiang Li, Seng Boh Gary Lim, Usman Mahmood, Jean M. Moran, Jason Ocana

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To determine the limits of iodine concentration detection (LOD) and quantification (LOQ) in dual-energy computed tomography using a 3D printed phantom while considering different background, ...

NTCP Modeling of Skin Systemic Sclerosis 12 Months Post Radiotherapy for Head & Neck Cancer

Authors: Gregory A Azzam, Danielle Cerbon, Laura Huang, Panayiotis Mavroidis, Diana Molinares, Stuart E Samuels, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center, University of Miami Sylvester Comprehensive Cancer Center, Mount Vernan Rehabilitation Medicine Associates, Department of Radiation Oncology, University of Miami, University of North Carolina

Abstract Preview: Purpose: This study aims at performing a normal tissue complication probability (NTCP) modeling by fitting the doses to the skin, sternocleidomastoid (SCM) muscle and subcutaneous tissue (subcut) stru...

Off-Axis Dependency of the Sun Nuclear MapCheck3 Diode Array

Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: The Sun Nuclear MapCheck3 device is used for patient-specific QA. While it is typically employed in perpendicular field-by-field delivery using the Isocentric Mounting Fixture, fields not ful...

Prostate Dosimetric Comparison between Cyberknife and Radixact Modalities Using Precision and Raystation Planning Systems

Authors: Mireille Conrad, CΓ©dric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: The Accuray Synchrony real-time motion fiducial tracking solution allows for prostate stereotactic treatment on both Cyberknife and Radixact machines. In our radiotherapy department, two solu...

Quantitative Analysis of Three Strategies for CTPA Scan Timing Optimization

Authors: Zahra Alyani Nezhad, Carrie Bartels, Rachel Bladorn, Sean D. Rose, Kelsey Schluter, Timothy P. Szczykutowicz

Affiliation: Departments of Radiology and Medical Physics, University Wisconsin-Madison, University of Wisconsin Madison, University of Wisconsin-Madison, University of Texas at Houston Medical School, University of Wisonsin-Madison

Abstract Preview: Purpose: Pulmonary embolism is a life-threatening condition, and computed tomography pulmonary angiography (CTPA) is the gold standard for diagnosis. Inadequate contrast enhancement often leads to a h...

Radiopathomic Characterization of Chemoradiation Resistance in Preclinical Models of Head and Neck Cancer

Authors: Rico Castillo, Katherine Gonzalez, Casey C. Heirman, Kyle J. Lafata, Xiang Li, Yvonne M Mowery, Yvonne M Mowery, Allison Pittman, Ashlyn G. Rickard, Breylon Riley

Affiliation: Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh

Abstract Preview: Purpose: To evaluate the relationships between quantitative imaging biomarkers and chemoradiation resistance in head and neck squamous cell carcinoma (HNSCC) using preclinical mouse models.

Met...

Reproducibility of Target Position during Surface-Guided Breath-Hold Adaptive SBRT of Liver Cancer

Authors: Lili Chen, Xiaoming Chen, Chang Ming Charlie Ma, Joshua Meyer

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Fast CBCT (HyperSight) acquisition technique together with a surface-guided breath-hold (SGBH) would allow a better image quality for accurate target/organ delineation. It facilitates breath-...

Retrospective Analysis of Treatment Pauses Due to Intrafraction Movement for Frameless Single Fraction Gamma Knife Icon Radiosurgery

Authors: Nina Burbure, Tawfik G. Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital

Abstract Preview: Purpose: Frameless gamma knife (GK) treatments use a thermoplastic mask coupled with high-definition motion management system that utilizes an infrared camera, and a reflective marker placed on the pa...

Retrospective Postimplant Dosimetry: Comparison of Line and Point Source for 131cs Low Dose Rate Intracranial Implant Brachytherapy

Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira

Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center

Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...

Targeted Multi-Criteria Optimization for Rapid Improvement of Organ-at-Risk Dose in the Setting of Prostate Stereotactic Body Radiation Therapy

Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: To utilize multi-criteria optimization (MCO) in a targeted fashion to quickly and easily improve dose to the rectum when treating the prostate with stereotactic body radiation therapy (SBRT)....

Ultra-Fast Commissioning and Quality Assurance with Plastic Scintillation Detector

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: Accurate, efficient, and reliable commissioning of linear accelerator (LINAC) is critical for ensuring high-quality radiation therapy treatments. The study uses advanced detector technology a...

Utilizing All Acquired Images from Fluoroscopically-Guided Interventions: Test Application with Event-By-Event Patient Dosimetry Calculations

Authors: Sagine Berry-Tony, Lasya Daggumati, James R Duncan, Melak Senay, Allan Thomas

Affiliation: University of Missouri-Kansas City School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: Most acquired images in FGIs are not permanently archived. In the context of modern computational prowess, novel improvements to FGI practice likely sit just under the surface of large-scale ...

What Do We Do with Our Old Pinnacle Data?

Authors: Caiden Atienza, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin

Affiliation: Iowa Health Care, University of Iowa

Abstract Preview: Purpose: Pinnacle3 TPS (Philips Radiation Oncology Systems, Fitchburg, WI, USA) support is set to end by December 31, 2026. This work presents a validated method to archive Pinnacle data, which may be...