Search Submissions 🔎

Results for "liver dome": 79 found

4D Monte Carlo Dose Evaluation for Mobile Targets in a Magnetic Field

Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun

Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...

A Conditional Point Cloud Diffusion Model for Deformable Liver Motion Tracking Via a Single Arbitrarily-Angled X-Ray Projection (PCD-Liver)

Authors: Yunxiang Li, Hua-Chieh Shao, Chenyang Shen, Jing Wang, Jiacheng Xie, Shunyu Yan, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Accurate liver deformable motion tracking is essential in image-guided radiotherapy to enable precise tumor targeting during treatment. We developed a conditional point cloud diffusion model ...

A Framework for Automated Selection of Dose-Volume Objectives to Improve Radiation-Induced Immune Suppression (RIIS)-Related Overall Survival (OS) Following Chemo-Radiotherapy

Authors: Gabriel Lucas Andrade de Sousa, Einsley-Marie Janowski, Cam Nguyen, Krishni Wijesooriya

Affiliation: Department of Radiation Oncology, University of Virginia, Department of Physics, University of Virginia

Abstract Preview: Purpose: Optimizing radiation therapy (RT) to spare the immune system may improve Overall Survival (OS) in cancer patients. This study develops a computational algorithm to identify optimal dose-volum...

A Real-Time 6 Degrees-of-Freedom Image Guided Radiation Therapy Technology Using Internal-External Motion Correlation Modelling

Authors: Jeremy T. Booth, Nicholas Hardcastle, Freeman Jin, Alicja Kaczynska, Paul J. Keall, Chandrima Sengupta

Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, Physical Sciences, Peter MacCallum Cancer Centre, Image X Institute, Faculty of Medicine and Health, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: An ESTRO survey reported that 71% of radiotherapy centers across 41 countries want to implement real-time image guided radiation therapy (IGRT) to improve patient outcomes. To address this gl...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Adaptive Proton Flash Therapy through Iterative Modular Pin Recycling

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
We propose a method to optimize adaptive proton FLASH therapy (ADP-FLASH) using modularized pin-ridge filters (pRFs) by recycling module pins from the initial plan, reducing pRF adjustment...

Addressing Radionuclide Decay Complexities in Targeted Alpha Therapy: A Computational Approach.

Authors: Denis Bergeron, Ryan P Fitzgerald, Ravneet Kaur, Rao Khan

Affiliation: John Hopkins University, NIST Radiation Physics Division, Howard University, National Institute of Standards and Technology

Abstract Preview: Purpose: There is growing interest in short-lived alpha-emitting radionuclides for cancer therapy due to their ability to selectively target and destroy cancer cells while sparing healthy tissue. Howe...

Advancing Ionizing Radiation Acoustic Imaging: A Deep Learning Approach for Denoising and Quantitative Reconstruction

Authors: Kyle Cuneo, Issam M. El Naqa, Dale W. Litzenberg, Yiming Liu, Xueding Wang, Lise Wei, Wei Zhang, Jiaren Zou

Affiliation: University of Michigan, H. Lee Moffitt Cancer Center

Abstract Preview: Purpose: To quantitatively map 3D dose deposition during radiotherapy, empowering real-time adaptive radiation treatment.

Methods: The research features reconstructing dose deposition from acou...

An Adaptive Radiotherapy Approach Sparing Preirradiated Critical Structures

Authors: Mohamed Bahaaeldin Mohamed Afifi, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Reirradiation of recurrent cancer or a newly developed lesion in a proximal location poses a challenge for radiation treatments. This is occasionally encountered in many modern clinics and ef...

An Efficient Workflow for X-Ray Imaging-Based IGRT/ART

Authors: Lili Chen, Ahmed A. Eldib, Chang Ming Charlie Ma

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Specialized adaptive radiotherapy (ART) systems have been developed and clinically implemented, which are either cost-ineffective such as MR-linacs or inflexible in workflow such as the Ethos...

An Energy Layer Optimization Approach for Spot Scanning Proton Arc Therapy

Authors: Wenhua Cao, Hadis Moazami Goudarzi, Madison Emily Grayson, Zongsheng Hu, Gino Lim, Steven Hsesheng Lin, Radhe Mohan

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Industrial Engineering, University of Houston, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) offers significant potential in treating complex cancer cases by delivering a continuous radiation dose as the gantry rotates. This study aims to investigate the pote...

Assessing the Potential of Remote Navigation Systems to Mitigate GI Toxicity in Abdominal SBRT

Authors: Justus Adamson, Wesley Andrew Cunningham, Caleb Logan Smith

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: Radiation induced bowel toxicity is a persistent issue for abdominal Stereotactic Body Radiation Therapy (SBRT). Remote magnetic navigation systems (RMNS) have been developed for use in magne...

Assessment of Automated Planning Templates for Genitourinary and Gastrointestinal Disease Sites for Online MR-Guided Adaptive Radiotherapy

Authors: Shahed Badiyan, Tsuicheng D. Chiu, Viktor M. Iakovenko, Steve Jiang, Christopher Kabat, Mu-Han Lin, Roberto Pellegrini, Arnold Pompos, Edoardo Salmeri, David Sher, Sruthi Sivabhaskar, Justin D. Visak

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, Global Clinical Science, Elekta AB, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Adaptive treatment planning requires robust strategies to enable streamlined on-couch processes, creating a significant barrier for planners transitioning from conventional to adaptive planni...

Assessment of Viscoelastic Changes in Ex Vivo Liver Tissue Using Pulsed Magnetomotive Ultrasound during Magnetic Hyperthermia

Authors: David Alejandro Collazos Burbano, Antonio Adilton Oliveira Carneiro, Paul L. Carson, Jose Eduardo Freire, Theo Zeferino Pavan, Joao Henrique Uliana, Nicholas Zufelato

Affiliation: University of São Paulo, University of Michigan, University of Sao Paulo

Abstract Preview: Purpose: Develop a theranostic platform that integrates magnetic hyperthermia (MH), ultrasound, and magnetic nanoparticles (MNPs) to improve diagnosis, treatment, and monitoring of hyperthermia proced...

Assessment of the Impact of CT Respiratory Motion on PET SUV Quantification through Virtual Imaging

Authors: Ehsan Abadi, Darrin Byrd, Paul E. Kinahan, Katie Marie Olivas, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Washington

Abstract Preview: Purpose: To evaluate the impact of respiratory motion during CT acquisitions on PET image quantification using an integrated PET-CT simulation pipeline.
Methods: A validated CT simulator (DukeSim) ...

Benefits on Respiratory Gating Delivery of Lung SBRT

Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng

Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University

Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Clinical Validation of a Deep-Learning Segmentation Tool for Head and Neck Cancer Patients and Thoracic and Abdominal Cancer Patients

Authors: Haijian Chen, Katja M. Langen, William Andrew LePain, Claire Tran, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Georgia Institute of Technology

Abstract Preview: Purpose: To validate the performance of a commercial deep-learning segmentation (DLS) tool for head and neck cancer (HNC) and thoracic and abdominal cancer (TAC) by comparing it to manual segmentation...

Cloud-Based Clonogenics Guide Nanoparticle-Mediated Chemo-Radiotherapy Against Brain Cancers

Authors: ISAAC Amoah, Jackie Austin, Charlotte Block, Kaylee Brilz, Dylan Bui, Andrew E. Ekpenyong, Jayce Hughes, Natasha Ratnapradipa, Sara Strom, Jacob Woolf

Affiliation: Creighton University

Abstract Preview: Purpose: Cancers of the brain and nervous system account for 1 in 100 cancer diagnoses in the US every year. Surgery, radiotherapy, and chemotherapy constitute the standard of care. For Glioblastoma (...

Comparison of Respiratory Motion between 4D-MR and 4D-CT in Compression Belt Patients

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...

Comparitive Case Analysis of Maa Mapping and Angiographic Iodinated Contrast for Y-90 SIRT Treatment Planning

Authors: Shengwen Deng, Sven L. Gallo, Robert S. Jones, David W. Jordan, Arashdeep Kaur, Aishwarya M. Kulkarni, Quibai Li, William R.M. Pedersen

Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center; School of Medicine, Case Western Reserve University, Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center, Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center; School of Medicine, Case Western Reserve University; Department of Radiology, Louis Stokes Cleveland VA Medical Center

Abstract Preview: Purpose:
Y-90 (Yttrium) SIRT radioembolization takes advantage of delivering localized radiation to the liver. Pre-treatment dosimetry is highly dependent on accurate MAA mapping, which may have an...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Contrast-Dependent Loss of Edge Sharpness in Low-Contrast Targets with Increasing Iterative Reconstruction Strength

Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Data-Driven Gating in Ga-68 PET/CT: Impacts on Patient Selection and Dosimetry Predictions in Radiopharmaceutical Therapy

Authors: Zhuo Chen, Tinsu Pan, Allan Thomas

Affiliation: Mallinckrodt Institute of Radiology, Washington University School of Medicine, WashU Medicine, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Misregistration between data-driven gated (DDG)-PET and CT can limit the benefits of motion correction and improved localization and quantitation. DDG-CT offers a solution to these issues. He...

Deep Learning-Based Multileaf Collimator Sequence Prediction for Automated VMAT Treatment Planning in Pancreatic Cancer

Authors: Zixu Guan, Takahiro Iwai, Takashi Mizowaki, Mitsuhiro Nakamura, Michio Yoshimura

Affiliation: Kyoto University, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose:
The goal of this study is to develop a fully automated treatment planning approach for VMAT in pancreatic cancer that can convert patient anatomy into LINAC machine parameters. In this wor...

Determination of Optimal Surface Rois for Sgrt-Guided Dibh Treatment of Abdominal Cancer

Authors: Megan E. Daly, Ajay Fernandez, Ryan D. Hernandez, Soo Kyoung Kim, Arta Monjazeb, Minahal Naveed, Peter C. Park, Jotsna Singh, Payton H. Stone

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To identify optimal deep-inspiration breath-hold (DIBH) surface-guided radiotherapy (SGRT) regions of interest (ROIs) for abdominal stereotactic body radiation therapy (SBRT) treatments.
M...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Direct Dose Verification in Liver SBRT Utilizing an Accumulative Daily CBCT Algorithm

Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...

Dosimetric Comparison of Lattice and 3D Grid VMAT Planning for Spatially Fractionated Radiotherapy

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to conduct a dosimetric comparison between lattice radiotherapy (LRT) and 3D grid treatment planning techniques, focusing on their differences in delivering three-dimensional ...

Dosimetric Impact of Auto-Segmentation with Replanning: An Analysis of a Prospective Clinical Trial

Authors: Kathryn J. Dess, Martha M. Matuszak, Dan Polan

Affiliation: University of Michigan

Abstract Preview: Purpose: A recent survey demonstrated 18 of 20 top academic institutions have implemented auto-segmentation. Studies to date have focused on geometric contour changes and dosimetric differences using ...

Dual-Modality Protoacoustic and Ultrasound Imaging for Real-Time Monitoring of Proton Therapy In Vivo

Authors: Kristina Bjegovic, Yong Chen, Lucia Rodriguez Gonzalez, Marti Roper, Liangzhong Xiang

Affiliation: University of California, Irvine, University of California Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Proton therapy is an increasingly popular cancer treatment due to its precision, enabled by the Bragg Peak (BP), which minimizes side effects. This profile necessitates in-patient localizatio...

Efficient Monte Carlo Proton Dose Calculation Using Denoising Diffusion Probabilistic Models

Authors: Chieh-Ya Chiu, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose: Monte Carlo simulation enables precise calculation of dose distribution in proton therapy through tracing the radiation particles with patient tissues. However, achieving clinical-level preci...

Enhanced Predictive Model for Toxicity and 3-Year Survival in HCC Patients Using Learning Health System Infrastructure and AI-Driven Statistical Profiling

Authors: Ameer Elaimy, Theodore Lawrence, Charles S. Mayo, Seyyedeh Azar Oliaei Motlagh, Benjamin S. Rosen

Affiliation: University of Michigan

Abstract Preview: Purpose: To analyze the impact of clinical features on short-term survival, toxicity, and poor outcomes in HCC patients treated with SBRT,using automated data aggregation and enhanced algorithms with ...

Evaluating DNA Damage Efficacy for 90y and 225ac Based Radiotherapy

Authors: Ramin Abolfath, Alejandro Bertolet, Kofi M. Deh, Rao Khan, Vanessa Sanders, Daniel Suarez-Garcia

Affiliation: Massachusetts General Hospital and Harvard Medical School, University of Sevilla, Brookhaven National Laboratory, Howard University

Abstract Preview: Purpose: To compare the efficacy of 225Ac to 90Y for local cancer therapy by quantifying DNA damage using Monte Carlo simulations.
Methods: The TOPAS n-Bio toolkit was used to simulate the irradiat...

Evaluating LiF:Mg,Ti TLD Reliability at Body Temperature for Long-Term Dose Monitoring

Authors: Larry A. DeWerd, Keith A. Kunugi, Autumn Rasmussen

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Ensuring the validity of the thermoluminescent dosimeter (TLD) response requires verifying that signal fading—defined by a reduction in stored signal—is well-known and corrected for under the...

Evaluating Necessity of Patient-Specific Deep Learning-Based Auto-Segmentation for Improved Adaptation for Abdominal Tumors

Authors: Asma Amjad, Renae Conlin, Eric S. Paulson, Christina M. Sarosiek

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: In an effort to improve contouring accuracy for abdominal MR guided online adaptive radiotherapy (MRgOART), patient-specific deep learning-based auto-segmentation (PS-DLAS) has been proposed....

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Evaluation of Daily Respiratory Pattern from a Single Free-Breathing Cone Beam CT Scan

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...

Feasibility of Rapidarc Dynamic for Lattice Radiation Therapy of Bulky Liver Tumors

Authors: Christine V. Chung, Laurence Edward Court, Meena S. Khan, Ethan B. Ludmir, Rachael M. Martin Paulpeter, Saurabh Shashikumar Nair, Callistus M. Nguyen, Joshua S. Niedzielski, Luis Augusto Perles

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Spatially Fractionated Radiation Therapy (SFRT) has re-emerged as an efficacious treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) has unique beam delivery capabilities that m...

From Concept to Clinic: A Phase-Based Approach for Implementing Auto-Segmentation in Radiation Therapy

Authors: Elizabeth L. Covington, Robert T. Dess, Charles S. Mayo, Michelle L. Mierzwa, Dan Polan, Jennifer Shah, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan

Abstract Preview: Purpose: Auto-segmentation improves contour consistency and standardization in radiation therapy but may introduce variations from current practices, potentially impacting treatment outcomes and toxic...

Functional Liver Image Guided Radiation Planning Using MRI with a Contrast Agent

Authors: Kenneth L. Homann, Natalie A Lockney, Hong Zhang

Affiliation: Department of Radiation Oncology, Vanderbilt University Medical Center, Vanderbilt University Medical Center

Abstract Preview: Purpose: The aim of this study is to develop a treatment planning methodology utilizing liver functional imaging via contrast-enhanced Magnetic Resonance Imaging (MRI) in patients undergoing stereotac...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Impact of Arc Number Variation on VMAT Lattice Radiotherapy Plans

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to evaluate the effects of varying the number of arcs on treatment plans created using Volumetric Modulated Arc Therapy (VMAT) for Lattice radiotherapy (LRT).
Methods: Thre...

Impact of Time-of-Flight Reconstruction and Motion Correction on PET-Based Dosimetry in 90y Radioembolization for Hepatocellular Carcinoma

Authors: Spencer Behr, Joseph Grudzinski, Youngho Seo, Jaehoon Shin, Yiran Wang, Frederick J. Wilson

Affiliation: University of California San Francisco, University of California, San Francisco, Voximetry, Inc., Voximetry, Inc

Abstract Preview: Purpose: Voxel-level imaging-based dosimetry enables a significant improvement in accurate and personalized treatment planning in radiopharmaceutical therapy, potentially leading to optimized disease ...

Implementation of a Virtual Quality Assurance System Using Raystation for Online MR-Linac Adaptive Radiotherapy

Authors: Min-Sig Hwang, Danny K. Lee, Daniel C. Pavord, Kyung Lim Yun

Affiliation: Allegheny Health Network

Abstract Preview: Purpose: Ensuring the quality of treatment plans through patient-specific pre-treatment quality assurance (QA) is essential. However, the use of physical phantom-based QA devices is not feasible for o...

Implementing a Knowledge-Based Planning Model for Gastrointestinal (GI) Site-Specific Plans for Photon Radiation Therapy

Authors: Andreea Dimofte, Maksym Sharma, Weibing Yang, Timothy C. Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose:
To assess the effectiveness and dosimetric impact of utilizing a knowledge-based planning model for GI site-specific plans.
Methods:
Six knowledge-based planning models were develope...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Influence of Treatment Site on Lung Shunt Fraction Estimation in 90y-Radioembolization Planning: Comparison of Planar and SPECT Imaging-Based Quantification

Authors: Lukas M. Carter, Jazmin Schwartz

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Accurate lung shunt fraction (LSF) estimation is essential for the safety and efficacy of 90Y-radioembolization therapy. This study compares planar gamma camera imaging and tomographic SPECT-...

Interplay of Relative Biological Effectiveness and Dose Rate in Eye Plaque Brachytherapy with Low Energy Photons

Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart

Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington

Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...

Intra-Organ Blood Vessel Mapping in Mice for Improved Pre-Clinical Radiation Dosimetry

Authors: Daylin Barroso, Chris Beekman, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Robert Joseph Dawson, Walter Murfee, Harald Paganetti, Andrew Robert Sforza, Julia D. Withrow

Affiliation: Massachusetts General Hospital - Harvard Medical School, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: To develop methods for quantifying the interaction of radiation with blood in the mouse whole body (MOBY) phantom for dosimetric applications. The most important of these are modeling the dis...

Introduce a Novel Spot-Scanning Proton Arc(SPArc) Optimization Algorithm for Single Energy Extraction(SEE) Synchrotron-Accelerator-Based Proton Therapy System (PTS)

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Jiajian Shen

Affiliation: Department of Radiation Oncology, Mayo Clinic, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study aims to develop the first SPArc optimization algorithm based on the Dynamic Programming (SPArc-DP), to improve the treatment delivery efficiency for synchrotron-accelerator-based P...

Investigating the Radiation Chemistry of Flash Radiation Therapy through Electron Paramagnetic (EPR) Spectroscopy

Authors: Ramin Abolfath, Alexander Baikalov, Stefan Bartzsch, Nolan M. Esplen, Alan Eduardo Lopez Hernandez, Emil Schueler

Affiliation: MD Anderson Cancer Center, PI Experimental Medical Physics, Institute of Radiation Medicine (IRM), Helmholtz Munich, Germany, Howard University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiation therapy (FLASH-RT) leverages ultra-high dose rates (UHDR) to spare normal tissue as compared to conventional (CONV)-RT while preserving tumor control; this is termed the FLASH...

MR-Based Functional Liver Imaging and Dosimetry to Predict Albi Change Post-SBRT

Authors: Madhava Aryal, James M. Balter, Yue Cao, Daniel T Chang, Kyle Cuneo, Joseph R. Evans, Theodore Lawrence, John Rice, Randall K. Ten Haken, Lise Wei

Affiliation: University of Michigan, Department of Radiation Oncology University of Michigan

Abstract Preview: Purpose: This study aims to identify predictors of global liver function change measured by albumin-bilirubin (ALBI) score following stereotactic body radiation therapy (SBRT) in hepatocellular carcin...

Minimizing Abscopal Effects in Normal Tissues with Flash-RT: Mechanisms of Action and Potential Clinical Applications

Authors: Liang Cui, Xingyu Lu, Hang Shang, LingHong Zhou

Affiliation: Southern Medical University

Abstract Preview: Purpose: This study examines how varying dose rates of radiotherapy impact normal tissues outside the target area and analyzes the protective effects and regulatory mechanisms of ultra-high dose rate ...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

Monte Carlo‐Based Shielding and Safety Assessment of a 7 Mev Flash Electron Beam Facility

Authors: Rafael Carballeira, David J. Gladstone, Philippe Liger, Rongxiao Zhang

Affiliation: TheryQ, Dartmouth College, University of Missouri, Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: To model a FLASH electron beam system (FLASHLAB) via first principle Monte Carlo methods, navigating installation configurations, shielding and regulatory radiation safety considerations for ...

Multi-Center Evaluation of an AI Beam Angle Prediction Model for Liver Treatments Using Pencil Beam Scanning Proton Therapy

Authors: Christopher Ackerman, Chang Chang, Yan-Cheng Huang, Robert Kaderka, Che Lin, Hsin-Chih Lo, Iain MacEwan, Yi-Chin Tu, James Urbanic

Affiliation: University of California San DIego, Taiwan AI Labs, National Taiwan University, California Protons Cancer Therapy Center, University of Miami, Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: To investigate the performance of an existing AI beam angle prediction model on external patient datasets for liver proton treatments. The AI model was trained on datasets exclusively from on...

Multi-Path Deep Learning Model for Predicting Post-Radiotherapy Functional Liver Imaging in Patients with Hepatocellular Carcinoma

Authors: Smith Apisarnthanarax, Stephen R. Bowen, Sunan Cui, Jie Fu, Clemens Grassberger, Yulun He, Yejin Kim, Matthew J. Nyflot, Sharon Pai

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Washington, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington, University of Washington and Fred Hutchinson Cancer Center

Abstract Preview: Purpose: 99mTc-sulfur colloid SPECT imaging enables quantitative assessment of voxel-wise liver function in patients with hepatocellular carcinoma (HCC). Accurately predicting post-radiotherapy (RT) l...

Optimal Choice of Companion Radiotracer for TAT 225Ac-Mti-201.

Authors: Vinay K Banka, Mikalai Budzevich, William R. Gibbons, Mark L. McLaughlin, Jacob Moriarty, Eduardo G. Moros, David L. Morse, Christopher J. Tichacek, Thad J. Wadas

Affiliation: Modulation Therapeutics Inc, Moffitt Cancer Center, University of Iowa

Abstract Preview: Purpose: A targeted alpha therapy drug, 225Ac-MTI-201, has been developed targeting the Melanocortin 1 Receptor for metastatic uveal melanoma and is currently in FIH clinical trials. Since alpha emiss...

Pipeline for Characterizing (Dosimetric) Impact of Respiratory Motion on Cardiac SBRT

Authors: Sarah Aubert, Leigh Conroy, Tony Tadic

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: Cardiac radioablation is an emerging non-invasive treatment option for patients with refractory or life-threatening ventricular tachycardia (VT), however it is difficult to deliver highly con...

Preclinical Assessment of 68ga-Dotatate As a Surrogate for 177lu-Dotatate Dose Distribution in Radionuclide Therapy

Authors: Payman Hejazi, Faraz Kalantari, Milad Peer-Firozjaei, Romina Pourhashem, Ehsan Tajikmansoury

Affiliation: Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Medical Physics, Semnan University of Medical Sciences, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine

Abstract Preview: Purpose:
Pretreatment biodistribution imaging play a crucial role in optimizing tumors and organ absorbed doses estimation in radionuclide therapy. Surrogating radionuclides for more efficient trea...

Predicting Proton Therapy Dose Delivery Accuracy: A Machine Learning Approach Using Iroc’s Proton Phantom Data

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop a machine learning model for predicting dose delivery accuracy and identifying its key factors in IROC’s proton phantom program.
Methods: IROC’s proton QA program has six proton...

Prospective Organ-Level Dose Estimation in CT Imaging Using Scout-Net: A Comparison with Established Methods

Authors: Maria Jose Medrano, Grant Stevens, Liyan Sun, Justin Ruey Tse, Adam S. Wang, Sen Wang

Affiliation: Department of Radiology, Stanford University, GE HealthCare, Stanford University

Abstract Preview: Purpose: Patient exposure to ionizing radiation is a major concern in CT imaging. Size-specific dose estimation methods can prospectively estimate organ-level radiation doses based on patient sizes an...

Proton Pencil Beam Scanning Ultra-High Dose Rate 3D Lattice Radiotherapy: A Proof-of-Concept Flash Sfrt Study

Authors: Richard Bakst, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Minglei Kang, Nancy Y Lee, Haibo Lin, Hang Qi, Charles B. Simone, Pingfang Tsai, Milo Vermeulen, Shouyi Wei, Xiaodong Wu, Lee Xu, Irini Yacoub, Xingyi Zhao, Ajay Zheng

Affiliation: University of Miami, Peking University, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, icahn school of medicine at mount sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose:
Three-dimensional lattice radiation therapy (3D-LRT) effectively achieves local tumor control with limited morbidity. Pencil beam scanning (PBS) proton therapy provides precise dose confor...

Quantitative Analysis of Dose Perturbation from Gantry Rotational Errors in Dynamic Spot-Scanning Proton Arc Therapy (SPArc)

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Lewei Zhao

Affiliation: Department of Radiation Oncology, Stanford University, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose:
This study investigates the dosimetric impact of systematic and random gantry position errors (GPE) during dynamic Spot-Scanning Proton Arc Therapy (SPArc) delivery.
Methods:
Four ca...

Radiation Sub-Segmentectomy in 90y Radioembolization: Post-Therapy Dosimetry, Treatment Response, and Pathological Necrosis

Authors: Guilherme Rosa Ferreira, Dan Giardina, John Karageorgiou, Chris Malone, Allan Thomas

Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Radiation segmentectomy has become a primary strategy in 90Y radioembolization, with localized treated volumes that can include up to two liver segments. The goal is complete pathological nec...

Rectangular Aperture-Based Beam Orientation Optimization for 4π Non-Coplanar Small Animal IMRT Delivery

Authors: Dante PI Capaldi, Lu Jiang, Qihui Lyu, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Preclinical small animal studies help understand radiation-induced biological responses, toxicities, and mechanisms, facilitating the translation of new therapies to patient treatment. Int...

The Iroc Houston Online User Portal - an Online Web Tool for Clinical Trial Sites

Authors: Paola E. Alvarez, Robert Dejournett, Mallory Glenn, Stephen F. Kry, Jessica R. Lowenstein, Andrea Molineu, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: Current IROC Houston practices are often reactive in nature, relying on several manual processing steps to receive and review institution data and distribute credentialing information. The IR...

Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...

Unidose: A Universal Framework for IMRT Dose Prediction

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Dose prediction (DP) is essential in guiding radiotherapy planning. However, current DP models for intensity-modulated radiation therapy (IMRT) primarily rely on fixed-beam orientations and a...

Using Multi-Peak Reconstructions for Dosimetry of Fast and Quantitative Lutetium-177 SPECT/CT

Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija

Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging

Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...

Using Single-Energy Bragg Peak (SEBP) Flash Combined with Intensity-Modulated Proton Therapy (IMPT) for Flash Treatment in a Clinical Synchrotron-Based Proton System

Authors: Chingyun Cheng, Ben Durkee, Carri K. Glide-Hurst, Minglei Kang, Haibo Lin, Bhudatt R. Paliwal, Charles B. Simone, Zhizhen Wei, Tengda Zhang, Xingyi Zhao

Affiliation: University of Wisconsin, Department of Mechanical Engineering, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Transmission Beam (TB), Single-Energy Bragg Peak (SEBP), and Single-Energy Spread-Out Bragg Peak (SESOBP) are primary proton conformal FLASH techniques. However, each comes with significant l...

Using the Liver Dome for Real-Time Respiratory Motion Adaptive Tracking in Cyberknife Stereotactic Body Radiotherapy (SBRT) for Lung Tumors

Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...

Utilizing All Acquired Images from Fluoroscopically-Guided Interventions: Test Application with Event-By-Event Patient Dosimetry Calculations

Authors: Sagine Berry-Tony, Lasya Daggumati, James R Duncan, Melak Senay, Allan Thomas

Affiliation: University of Missouri-Kansas City School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: Most acquired images in FGIs are not permanently archived. In the context of modern computational prowess, novel improvements to FGI practice likely sit just under the surface of large-scale ...

Validation of a Simulation Tool and in-Silico Assessment of Low Contrast Detectability for Super-Resolution Deep Learning Reconstruction

Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin

Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA

Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...

Voxel-Dose Implications of Single-Compartment Dosimetry for Ablative 90Y-Radioembolization Segmentectomy

Authors: Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: 90Y-radioembolization is utilized with curative intent. While single-compartment doses to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actu...